| 1 | Excavating in post holes (or similar holes) each not exc 0.50 Cum and getting out in hard / dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layer not exc 25cm, watering, and removing surplus soil to a distance nexc 50m and making good surface all as directed. |
| 2 | M & Lfor PCC(1:3:6) type D-2 using 40mm graded stone aggregate in foundation/filling and mass concrete as in post holes complete all as specified and as directed. |
| 3 | Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and as directed. |
| 4 | S & F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall / as window chajja fixed with shelf tapping screws inlcuding plain galvalume sheet bent to required shape as required on ground as specified and directed. |
| 5 | S & F prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall / as window chajja, fixed with shelf tapping screws inlcuding plain galvalume sheet bent to required shape as required on ground as specified and directed . |
| 6 | M & Lsteel work in tubular trusses, purlin, rafters and vertical poles including special shape washer etc using ERW or induction butt welded tube conforming to IS-1161-1929 grade St.-240 including one coat shop primer complete all as specified and as directed.. |
| 7 | S & Fplates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmentincluding welding etc conforming to Fe-410-W (grade-E-250) quality \"B\" complete all as specified and as directed.. . |
| 8 | M & L preparation of new or previously untreated surfaces of steel of any description over 10cm widthor girth, not otherwise described and applying two coats of synthetic enamel paint over a coatof a red oxide zinc primer complete all as specified and as directed.. |
| 9 | M & L for hard core of broken stoneof gauge not exc 63mm deposited spread and leveled in layers not exe 15cm thick watered and rammed to a true surface complete all as specified and as directed.. |
| 10 | M & Lfor PCC 100mm thick ,1:4:8 type D-2 using 40mm graded stone aggregate asin sub base for flooringcomplete all as specified and as directed.. |
| 11 | M & L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 12 | Excavating in trenches, not exc 1.50 Mtr wide and not exc 1.50 Mtr in depth for foundation etc or for shafts, wells, cesspits, manholes, pierholes etc and not exc 10 Sqm on plan and not exc 1.50 Mtr in depth and getting out in hard / dense soil complete all as specified and as directed.. |
| 13 | Excavating in trenches, not exc 1.50 Mtr wide and not exc 1.50 Mtr in depth for laying of cables and getting out in soft / loose soil complete all as specified and as directed.. |
| 14 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as directed.. |
| 15 | Removal excavated surplus material (soil) not exc 50 Mtr and depositing where as directed at a level Not exc 1.50 Mtr above the starting point complete allas directed. |
| 16 | M & L for cement concrete type D-2, 1:4:8 using 40mm graded stone aggregates as in foundation, filling and mass concrete complete all as specified and as directed.. |
| 17 | M & L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:5:8) grade D-5 and setting in CM 1:6 complete all as specified and as directed.. |
| 18 | M & L for 15mm thick rendering in CM 1:4 over brick / concrete wall surfaces finished the surface even & smoth with sponge finished complete all as specified and as directed.. |
| 19 | M & L for preparation newly plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed. |
| 20 | M & L for point wiring of any length using approved colour coding as per IS with stranded copper conductor 1.50 Sqmm (Nominal area), two single core, PVC insulated and unsheathed stranded FRLS H cable 1100 Volts grade, ISI - 694 marked in Non metalic PVC conduits medium grade heavy duty ISI Marked 20mm dia including all accessories etc with PVC modular boxes / PVC sunken boxes as required at site and as directed including modular frame / cover plate suitable for mounting switches / sockets etc and PVC insulated stranded copper conductor 1.50 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified and directed for the following :- Note : (i) Making good of disturbed surfaces will be done by contractor without any extra claims |
| 21 | Two light point controlled by one, one way switch complete all as specified and directed. |
| 22 | One 3 pin 5 Amps socket outlet point controlled by one, one way swith on same board complete all as specified . |
| 23 | One 3 pin Amps socket outlet point controlled by one , one way switchindependent board complete all as specified . |
| 24 | All as per item No 20 above but with 2.50 Sqmm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS H cable 1100 Volts grade ISI-694 marked including PVC insulated stranded copper conductor 2.50 Sqmm single core cable as earth and connecting to commom earth dolly complete all as specified for one 15 Amps sockets outlet point on independent boardall as specified and as directed. |
| 25 | S & F modular switch 6 Amps, Single Pole one way 230 Volts, white / ivory finish complete all as specified. |
| 26 | S & F modular socket outlet 3 pin 6 Amps 2 module 230 Volts , Single pole one way suitable for plug tops complete all as specified |
| 27 | S & F modular switch 16 Amps,Single Pole, one way, 230 Volts white / ivory finish complete all as specified |
| 28 | S & F modular socket outlet 2/3 pin 16 Amps, multipurpose 2 module, 230 Volts, single pole one way suitable for plug tops complete all as specified |
| 29 | S & F ceiling rose surface bakelite type, three terminals PVC / polycorbanate body , ISI marked complete all as specified |
| 30 | Supply and fix LED light fittings surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat disspation with polycarbonate diffuser & integrated electronic diver with industrial grade heavy duty driver 20 Watt LED complete including all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector complete all as specified and as directed. |
| 31 | M & L for sub main wiring complete with two single core 6 Sqmm 1100 Volts grade, PVC insulated stranded copper conductor FRLS H cable with continuous copper earth conductor of 6 Sqmm drawn in and including Non metalic PVC conduit medium grade 25mm dia including accessories complete all as specified and directed.Note : (i) Making good of disturbed surfaces will be done by contractor without any extra cost to the Govt. (ii) Two runs of 6 Sqmm conductor, One run of earth conductor and one run of PVC conduit 25mm dia shall be measured as one unit RM length. |
| 32 | S & F MCB SPN DB 8 way, double door with 200 Amp rated busbar 240 Volt complete all as specified. |
| 33 | S & F MCB TPN DB 4 way, double door complete all as specified . |
| 34 | S & F MCB single pole rated capacity 6 to 32 Amps 240 Volt, breaking capacity 10 KA \"C\" curve complete all as specified . |
| 35 | S & F MCB four pole rated cpacity 40 Amps 240 Volts, breaking capacity 10 KA \"C\" curve complete al as specified . |
| 36 | S & F MCB TPN 40 Amps, 10 KA \"C\" curve complete all as specified and directed. |
| 37 | S & F MCB double pole of rated capacity 40 Amps, 240 Volts,breaking capacity 10 KA \"C\" curve complete all as specified |
| 38 | M & L for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6 mm buried directly in ground earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate vertically to depth of not less than 1.5 Mtr below ground level connected to and including GI wire 4mm dia and GI pipe 15mm dia light grade for protection to the extent of 7.5 Mtr as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part-I including RCC cover and MS angle iron frame, watering arrangement with GI pipe 20mm dia and MS funnel concrete pit including excavation and earth work in any type of soil and testing on completion etc complete all as specified andas directed. Note : GI earth wire and 15mm GI protection pipe light grade upto 7.5 Mtr length shall deemed to be included in quoted rates. |
| 39 | Supply, Fixing on wall , laying & testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts graded with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and as directed. |
| 40 | M & L for cutting of road / hard standing and making good with PCC 1:2:4, type B-1 using 20mm graded stone aggregate complete all as specifieand as directed. |
| 41 | Supply and fix MCCB 63 Amps, breaking capacity 16 KA,4 pole complete all as specified and as directed. |
| 42 | M & L for rainforced concrete pipe NP-2 with one collar per length of size 100mm bore dia in 1 RM each half round (for bottom and top) and before laying excavated area shall be leavelling all as specified. Note :- Two half round pipe(Bottom and top) will be measured as one RM. |