| 1 | 7 Meter GI Pole:Supply, installation, testing & commissioning of Round top 7 m octagonal galvanised tapered pole(above ground level),fabricated out of 3 mm thick sheet complete within built junction box, base plate size 300 x 300 x20 mm ,two arm of ERW galvanised pipe of 60mm dia and 1min length on two side of pole shaftas per detailed specifications.Pole should be made of BSEN 10025 grade mild steel, polygonal and continously tapered in three sections, hot dipped galvanised (as per BS EN ISO 1461 and suitable for wind velocity of 200 Km/Hr design life 25 years,terrain category -2.Juncion box shouldbe provided 500 mm above base plate with 4 Nos terminals on epoxy insulators, 2 No.6A SP MCB &1 no.neutral link.Base plate should have 4 Nos holes on each side suitable for mounting onRCC foundation 250 mm above FGL. General specifation and drawing attached in Annexure- 1 ( Final Drawing and specification should be approvedfrom EIC before manufacturing) |
| 2 | 10 Meter GI Pole:Supply, installation, testing & commissioning of Round top 10 m octagonal galvanised tapered pole(above ground level),fabricated out of 3 mm thick sheet complete within built junction box, base plate size 300 x 300 x20 mm ,two arm of ERW galvanised pipe of 60mm dia and 1min length on two side of pole shaftas per detailed specifications.Pole should be made of BSEN 10025 grade mild steel, polygonal and continously tapered in three sections, hot dipped galvanised (as per BS EN ISO 1461 and suitable for wind velocity of 200 Km/Hr design life 25 years,terrain category -2.Juncion box shouldbe provided 500 mm above base plate with 4 Nos terminals on epoxy insulators, 2 No.6A SP MCB &1 no.neutral link.Base plate should have 4 Nos holes on each side suitable for mounting onRCC foundation 250 mm above FGL. General specifation and drawing attached in Annexure- 6 ( Final Drawing and specification should be approvedfrom EIC before manufacturing) |
| 3 | 16 Meter Motorised HIGH MAST Pole: Supply, installation, testing & commissioning ofminimum 3 mm thick ,16 m high mast suitable for mounting 8 nos of 300W led flood light , made of BSEN 10025 grade mild steel, polygonal and continously tapered in three sections, hot dipped galvanised (as per BS EN ISO 1461 and suitable for wind velocity of 200 Km/Hr design life 25 years,terrain category -2.The high mast shall be complete with following accessories:1) Head frame2) Galvanised moveable lantern carriage suitable for luminaries and its control gear boxes as per design3) Double drum winch4) Compensating disc 5) SS hoisting rope 6) Trailing cable 7) Lightning finial 8) Foundation bolts and nuts 9) Anchor plate and template 10) Integral power tool at the base compartment. 11) An electrical junction box of FRP at base of mast at door level with 32A four poleMCB, single dial time switch,25A TP contactor for autometic switching of luminaries, power tool control with 2 nos of 9A contactor ,raise,lowre push button control wire required for operation , suitable socket for terminating trailing cable, 5pin 4 15V 16/20A socket for three phase power tool operation complete with internal wiring etc.Any other items required formotorised operation of the high mast pole. General specifation and drawing attached in Annexure- 2 ( Final Drawing and specification should be approvedfrom EIC before manufacturing) |
| 4 | FOUNDATION OF for 7 meter octagonalPOLEFoundation with RCC(Gr.M20,PCC(1:3:6),12mm ,10mm dia rod ,2 nos of 6 SWG loop earthing wire,M-24 J type bolt as per drawing . Detail drawing and specification attached in Annexure-3Note:- All the RCC,PCC,Centering and shuttering, Steel reinforcement Work, loop earthing work and other work necessary for complete foundation is included in this scope. |
| 5 | FOUNDATION OF 16 meter high mast POLE Foundation with RCC(Gr.M20,PCC(1:3:6),12mm dia rod ,2 nos of 6 SWG loop earthing wire,M-24 J type bolt as per drawing Detail drawing and specification attached in Annexure-4Note:- All the RCC,PCC,Centering and shuttering, Steel reinforcement Work, loop earthing work and other work necessary for complete foundation is included in this scope. |
| 6 | RCC Work for foundation of 10 Meter PoleProviding and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 7 | Centering and shuttering for foundation of 10 Meter PoleCentering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns |
| 8 | PCC Work for foundation of 10 Meter PoleProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 9 | Steel reinforcement Work for foundation of 10 Meter PoleSteel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Hot rolled deformed bars |
| 10 | GI Wire Earthing for foundation of 10 Meter PoleProviding and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 11 | Supply of 4Cx16 Sqmm FRLS XLPE Armoured Alluminium Cable, 650/1100V. grade confirming to IS : 7098 (Part-1) 1988 |
| 12 | Supply of 4Cx35 Sqmm FRLSXLPE Armoured Alluminium Cable, 650/1100V. grade confirming to IS : 7098 (Part-1) 1988. |
| 13 | Cable Laying and cable route marker with foundationLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering with brick on 3 side and refilling the trench etc as required along with cable route marker of1 feet height above ground with PCC foundation. |
| 14 | Supply, installation, testing & commissioning of 100W LED flood light fixture as per specification mentioned in Annexure-5 of NIT |
| 15 | Supply, installation, testing & commissioning of 70W led street light fixture as per specification mentioned in Annexure-5 of NIT |
| 16 | Supply, installation, testing & commissioning of 350 W led Flood light fixture as per specification mentioned in Annexure-5 of NIT |
| 17 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.(2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire) |
| 18 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4CX 16 sq. mm Cable |
| 19 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4CX 35 sq. mm Cable |
| 20 | Supply of outdoor stand mounted feeder pillar with 63A TPN MCCB incomer, electronic digital type timer, 63A TP contactor for the automatic switching of luminaries,4 nos of 32A 3 pole MCB for distribution,2 nos of 32A contactor,ON oFF switch ,voltmeter,ammeter and other equipment required for switching the street light pole. The panel should be floor mounted type, made of 2 mm CRCA steel with powder coating paint and have the below mentioned item1. 63A MCCB with extended rotary handel as incomer - 1 No2.ON,OFF push button - 2 Sets3. 32A MCb- 4 Nos4. ON,OFF pIndication - 2 Sets5. 32 A contactor -2 Nos6.63A contactor -1 no7. Electronic digital type timer -1 Nos8. Voltmeter and ammeter - 1 Nos each |