| 1 | Periodical Maintenance of Electrical and Mechanical installations involving repairs and maintenance, attending to complaints/faults/breakdown and taking rectification action for ensuring serviceability/satisfactory working condition of the system, performing preventive maintenance checks, maintenance of records/documentations etc.as per the detailed specifications, terms and conditions cover under this contract on all working days including Sunday and Holidays. |
| 2 | 1. DVOR, GP, LLZ, TXR (ANS) etc.2. GLF( R/Way, T/Way, CAT-I, SAPL, Wind Cone, Landing-T,AFL, AOL,ATS Building (GSS) etc.3. Operation of Water Pump & Water Treatment Plant |
| 3 | Carrying out any of the internal and external schedule items available in DSR (E&M) 2022 as when required and as directed by E-I-C complete as required for a fixed amount of Rs.02 Lakhs. (Note: The contractor has to quote an amount above or below the fixed amount of Rs.02 Lakhs. The difference of the amount so quoted and Rs.02 Lakhs shall be calculated for % age w.r.t the Rs. 02 Lakhs. The said work out +/- % age will be applied to the DSR\" 2022 rate and shall consider as payable rate of the bidder for each items.)Example for quoting the rate: -(i)Agency Quoting ?1,80,000.00 in the Rate stands for 10% below the Estimate amounting of ?2,00,000.00.Payment will be made 10% below on DSR 2022 rate against items.(ii)Agency Quoting ?2,20,000.00 in the Rate stands for 10% above the Estimate amounting of ?2,00,000.00. Payment will be made 10% above on DSR 2022 rate against items.(iii) Agency Quoting ?2,00,000.00 in the Rate stands same as Estimate amounting of ?2,00,000.00. Payment will be made same as DSR 2022 rate against items. |
| 4 | Re-winding of ceiling fans of 1200/1400 mm sweep with super enamelled copper wire of suitable guage & insulation grade i/c replacement of ball bearing, shaft etc. as required. Dismantling, transportation to workshop & back and re-installation i/c connection , testing & commissioning. |
| 5 | Re-winding and repairing of 3 HP capacity three phase sumbersible pump motor etc i/c replacement of ball bearing, shaft etc. as required. Dismantling, transportation to workshop & back and re-installation i/c connection , testing & commissioning. |
| 6 | Re-winding and repairing of 5 HP capacity three phase sumbersible pump motor etc i/c replacement of ball bearing, shaft etc. as required. Dismantling, transportation to workshop & back and re-installation i/c connection , testing & commissioning. |
| 7 | SITC of 900 VA/12V sine wave inverter with output voltage of 230 V single phase complete set with 1 No. 12V, 180 AH tubular battery complete in all respect as required. (Inverter make: Microtek or equivalent & Battery make: Exide or equivalent.) |