Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #43548940

Tender For Repairs Maintenances Of Dg Sets Amf Panels Servo Stabilizers And Connected Works At South North Side Runway At Hansa Vihar Under Age Em I Of Ge Nw Vasco

Issued by Statutory Bodies & Commissions/Committees · vasco, Goa
Tender Value
39.90 Lakhs
Estimated cost
Bid Submission
24 Jun 2024
0 days left
EMD
79800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
vasco → Goa
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Repairs Maintenances Of Dg Sets Amf Panels Servo Stabilizers And Connected Works At South North Side Runway At Hansa Vihar Under Age Em I Of Ge Nw Vasco

BOQ

NAME OF WORK : REPAIRS / MAINTENANCES OF DG SETS, AMF PANELS SERVO STABILIZERS AND CONNECTED WORKS AT SOUTH& NORTH SIDERUNWAY AT HANSA VIHAR UNDER AGE E/M - I OF GE (NW) VASCO (Tender ID : 2024_MES_657246_1)
Sl. No. Item Description
1Service Charges for Carrying out \"C\" Check maintenance for DG sets from authorised rep or trained service engineer from the OEM of DG set of upto 500 KVA capacityinjector & valve tappet setting, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unserviceable engine oil, clean the oil sump and refilling with required quantity of new oil & coolant top up, charging of battery, filling of distilled water, cleaning of radiator fins by using blower /inside tank with solution (caustic soda with water) to the entire satisfaction of Engineer-in-Charge including trial & testing etc.(Note :- (a) New spares required for \"C\" check will be measured and paid separately as supply only.
2Supply only Kit fuel filter
3Supply only Element for Lubrication oil filter.
4Supply only Kit Element of super bypass filter.
5Supply only Kit Conversion
6supply only fuel Feed pump
7Supply only Kit Fuel & coolent hoses
8Supply only Belt set
9Supply only Air Cleaner element outer and inner complete.
10S&F in repairs Low lub oil pressure switch with adaptor
11All as per item No 1.00 above butDG set of 200/250 KVA capacity Engine. Supply only spares will be as per Ser No 2.01 to 2.08.
12Supply only Lubrication oil filter
13Supply only Air Cleaner element outer and inner complete.
14Supply only Kit Conversion
15Supply only Fuel Filter
16Supply only Kit Fuel & coolent hoses
17Supply only Belt set
18Supply only bypass filter
19supply only fuel Feed pump
20All as per item No 1.00above but DG set of 160/180KVA capacity Engine.
21Supply only Lubrication oil filter element
22Supply only Fuel Filter element
23Supply only Air Cleaner element outer and inner complete.
24Supply only Kit Conversion
25Supply only Kit Fuel & coolent hoses
26Supply only Belt set
27supply only fuel Feed pump
28All as per item No 1.00above but DG set of 100/125 KVA capacity Engine.
29Supply only Filter Fuel element
30Supply only Cartridge, Lub oil filter
31Supply only Air Cleaner element outer and inner complete.
32Supply only Kit Conversion
33Supply only Kit Fuel & coolent hoses
34Supply only Belt set
35Supply only fuel Feed pump
36All as per item No 1.00above but DG set of 30/35KVA capacity Engine.
37Supply only Lubrication oil filter element
38Supply only Fuel Filter element
39Supply only Kit Conversion
40Supply only Kit Fuel & coolent hoses
41Supply only Belt set
42Supply only Air Cleaner element outer and inner complete.
43supply only fuel Feed pump
44All as per item No 1.00 above butDG set of 20 KVA capacity Engine.
45Supply only Lubrication oil filter element
46Supply only Fuel Filter element
47Supply only Kit Conversion
48Supply only Air Cleaner element outer and inner complete.
49Supply only Kit Fuel & coolent hoses
50Supply only Belt set
51supply only fuel Feed pump
52All as per item No 1.00 above but DG set of 15 KVA capacity Engine.
53Supply only Lubrication oil filter element
54Supply only Fuel Filter element
55Supply only Air Cleaner element outer and inner complete.
56Supply only Kit Conversion
57Supply only Kit Fuel & coolent hoses
58Supply only Belt set
59supply only fuel Feed pump
60All as per item No 1.00 above but DG set of 62.5/63/65 KVA capacity Engine.
61Supply only Lubrication oil filter element
62Supply only Fuel Filter element
63Supply only Air Cleaner element outer and inner complete.
64Supply only Kit Conversion
65Supply only Kit Fuel & coolent hoses
66Supply only Belt set
67supply only fuel Feed pump
68All as per item No 1.00 above but DG set of 625 KVA capacity Engine.
69S & F in repairs Kit, fuel filter
70S & F in repairs Element for Lubrication oil filter.
71S & F in repairs Kit, Element of super bypass filter.
72S & F in repairs Air filter Outer element.
73S & F in repairs Air Filter inner element.
74Supply only Kit Fuel & coolent hoses
75Supply only Belt set
76Supply only Kit Conversion
77Supply only fuel feed pump assly
78All as per item No 1.00 above but DG set of 500 KVA capacity Engine.
79Supply only Kit, fuel filter
80Supply only Element for Lubrication oil filter.
81Supply only Kit, Element of super bypass filter.
82Supply only Air filter Outer element.
83Supply only Air Filter inner element.
84Supply only Kit Conversion
85Supply only Kit Fuel & coolent hoses
86Supply only Belt set
87Supply only fuel feed pump
88All as per item No 1.00 above but DG set of 400 KVA capacity Engine.
89Supply only Lubrication oil filter, Cartridge.
90Supply only Fuel Filter element
91Supply only Kit Conversion
92Supply only Kit, Element of super bypass filter.
93Supply only Air filter Outer and inner element complete.
94Supply only Kit Fuel & coolent hoses
95Supply only Belt set
96S&F in repairs fuel feed pumpNote :- (1) The \"C\" Check Maint spares, engine oil, Coolant, caustic soda solution (restore plus) will be measured and paid separately under relevent item of this schedule. (2) Any other check as per menufacturer\"s instructions / Engr In charge directeion shall be carried out by the contractor and the same may be included in the quoted rate.and directed by Engineer-in-charge.
97S & F in repairs Radiator assy with tank of complete set made up of copper/aluminium fins and tube suitable for 15KVA to 320 KVA DG set of any make all as directed.
98Service Charges for Carrying out the \"B\" Check maint from authorised rep or service engineer from the manufacturer of DG set of upto 500 KVA capacity Enginechecking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters, checking inlet & Exhaust manifold caps crews, checking of fan hub & water pump, toping up level the existing engine oil, coolant top up and in replacement, supplying & fixingof following spares :-(a) Kit, fuel filter and ring - 2 Kit(b) Element for Lubrication oil filter - 2 Nos.Note :- \"B\" check shall be carried out on running of 500 hrs or three months whichever is earlier.(c) Kit, Element of super bypass filter - 01 Kit
99All as per item No 98 above here above but DG Set Capacity 200/250 KVA.
100All as per item No 13 above but DG Set Capacity 160/180 KVA.
101All as per item No 13 above here above but DG Set Capacity 100/125 KVA.
102All as per item No 13 above here above but DG Set Capacity 62.5 KVA.
103All as per item No 13 above here above but DG Set Capacity 30/35 KVA.
104All as per item No 13 above here above but DG Set Capacity 20 KVA.
105All as per item No 13 above here above but DG Set Capacity 15 KVA.
106Supply & filling Coolant concentrate Superkool xtra as required in the DG oil sump all as directed.Make : VALVOLINE/SERVO/ HINDUSTAN / Bosch
107Supply & filling Engine Oil Premium15 W 40 grade API CI 4 PLUS as required in the DG oil sump all as directed.Make : VALVOLINE/SERVO/HP/ POWER OIL
108Supply & chelating cleaner Restore Plus solution Part No. AX1001098Make : Cummins for engines cooling system all as directed.
109Dismantling the defective alternator of any capacity from the existing foundation and from Engine after removing all electrical connections, transporting to approved / authorised / directed workshop, opening and taking out burnt winding, cleaning the stator assy rewinding with super enameled copper wire as per existing gauge as per original manufacturer and applying insulating varnishing of ‘F’ class, baking in oven re-assembling the alternator, transporting back tosite re-installing the same position, carrying out alignment of complete DG set connecting up all electrical connections testing and commissioning complete.Note: - (a) Rate quoted shall be deemed to be inclusive of making good the disturbed surfaces.(b) The DG set shall be tested on load as per rated capacity for the satisfaction of Engineer- in- Charge to achieve designed parameters.
110Dismantling the defective alternator of any capacity from the existing foundation and from Engine after removing all electrical connections, transporting to approved / authorised / directed workshop, opening and taking out burnt winding, cleaning the main Rotor assy rewinding with super enameled copper wire as per existing gauge as per original manufacturer and applying insulating varnishing of ‘F’ class, baking in oven re-assembling the alternator, transporting back tosite re-installing the same position, carrying out alignment of complete DG set connecting up all electrical connections testing and commissioning complete.Note: - (a) Rate quoted shall be deemed to be inclusive of making good the disturbed surfaces.(b) The DG set shall be tested on load as per rated capacity for the satisfaction of Engineer- in- Charge to achieve designed parameters.
111S & F in repair door hinges for canopy of any capacityofDGset doorincluding nut, bolt, drilling of hole, welding as per directed.
112Supply and fixing in repair battery terminals brasssuitable for 95 AH to 180 AH battery .
113Dismantling & chemical cleaning of radiator assy from the DG set of 125 to 320 KVAcapacitycarefully for necessary repair, soldering the cooling tube if found weak /leakage,cleaning properly, replacement of nuts, bolts, rubber mounting bushes etcand refixing at the same site including testing on completion.
114All as per Item No 28 above, but for 15 KVA to 100 KVA DG set
115S & F battery charging unit panel mounted automatic operated electronically24 Volts DC out put and 230 volts incoming AC, as per the existing make and size to accommodate in the space provided in the AMF panel board. Make : NHP/STC or equivalent
116S & F battery charging unit panel mounted automatic operated electronically12 Volts DC out put and 230 volts incoming AC, as per the existing make and size to accommodate in the space provided in the AMF panel board. Make : NHP/STC or equivalent
117S & F in repairs connecting and commissioninglead acid battery 12 volts 180 AH.Make : Exide/ Amara Raja or equivalent
118S & F in repiarsconnecting and commissioning lead acid battery 12 volts 130 AH.Make : Exide/Amara raja or equivalent
119Dismantling the unserviceable Dynamo / Alternators 12/24 volts and rewindingwith ‘F’ class copper wire of 22 /existing gauge incl dismantling the old coil, cleaning thoroughly and winding with super enamelled copper cord of existing size and gauge, varnishing, drying etc and re fixing with dynamo/ alternator properly including testing on completion.
120Dismantling the defective Dynamo /Alternators 12/24 volts and necessary repair with replacement of defective spares such as, carbon brushes, carbon spring, bearing, bushes, defective wiring, and soldering after re-fixing at site.
121Dismantling the defective self starter assy of 12/24 volts and necessary repair with replacement of defective spares such as, carbon brushes, carbon spring, bearing, bushes, defective wiring and soldering after repair, re-assembling and refixing at site complete as directed including testing on completion.
122M&L for providing new AVR unit suitable for 62.5 KVA to 200 KVA DG Set size in repairs ie taking down of old AVR unit, complete all as specified and as directed by Engineer -in-charge. Make: Kirloskar/cummins/stanford
123All as per Item No 37 above, but for 320 KVADG set Make: Kirloskar/cummins/stanford
124All as per Item No 37 above, but for 15to 35 KVA DG setMake: Kirloskar/cummins/stanford
125Dismantling the old and unserviceable DG Set oil pressure pipe of existing sizeand replacing the same with ofexisting size and equal length of15 KVA to 320 KVADG Set includingboth side hose clamp, etc as directed by the Engineer in Charge .
126Dismantling the defective exciter of DG set of any capacity from the existing foundation and engine after removing all electrical connections, transporting to workshop rewinding the burn out coil complete with super enamelled copper wire rewinding, applyinginsulating varnish of \"F\" class baking in oven reassembling the alternator, transporting back to site, re-installing the same carrying out alignment of complete DG Set connecting up all electrical connections, testing & commissioning complete.
127Supply and fixing in repair type digital volt meter square type 96x96 mm up to 3 Phase AC 50 HZ, 500 volts of and connecting complete. Make : Meco/AEor equivalent all as directed.
128Supply and fixing copper cable multi stranded suitable for 12/24 volts battery replacing the same with ofexisting size and equal length complete fixing with brass clamp at both ends including taking down of old one from the existing battery.
129supply and fixing of lamp indicator assy LED lamp type 230 volts AC .
130S &F in repair asbestos rope 12 mm dia of superior quality for wrapping with the exhaust pipe of the DG set complete as directed.
131Scraping the old paint from the DG set of 320 KVA capacity and engine, applying one coat of synthetic enamel paint of approved make, writing of SM/MES No at easily visible manner complete as directed. Notes for item No 46 to 48 :-colours of paint for engine/ canopy/ and base plate are approved by engineer - in- charge.
132All as per item No 46 above but DG Set 100 KVA to 250KVA DG Set.
133All as per item No 46 above but DG Set 15 KVA to 63KVA DG Set.
134S & F in repairs Turbo kit for 320KVA DG Set for Cummins / Kirloskar / Greaves DG Set
135S & F in repairs Turbo kit for 62.5 to 250 KVA DG Set for Cummins / Kirloskar / Greaves DG Set
136S & F in repairs self starter 12V/24V with sononoid switch assy complete set as per existingmake of DG Set 320KVA all as directed.
137S & F in repairs self starter 12V/24V with solenoid switch assy complete set as per existing make of DG Set for 100 to 250 KVA all as directed.
138S & F in repairs Engine solenoid switch 12 Volt complete set as per existing size and make of DG Set.
139S & F in repairs Engine solenoid switch 24 Volt complete set as per existing size and make of DG Set.
140S & F in repairs magnetic speed censor assy suitable for Kirloskar make DG sets all as directed. Make : Kirloskar
141S & F in repairs Electronic DG controller control unit suitable for 100 to 250 KVA Capacity DG sets incl neccessary connections and testing complete all as directed.
142S & F in repairs ElectronicDG controller control unit suitable for 320KVA Capacity DG sets incl neccessary connections and testing complete all as directed.
143S & F in repairs ElectronicDG controller control unit suitable for 15 to 63 KVA Capacity Kirloskar make DG sets all as directed.
144Dismantling and taking out the defected Electromagnetic speed Governor unit with fuel injector pump assy from the DG set, transport to authorised work shop, cleaning the Fuel injector, Nozzle, calibration in test bench re-assembling into the DG set with necessary new gaskets/ nut, bolt and washer and testing complete all as directed. Note : The cost of spares like new injector/nozzle/gasket/seal/nut, bolt and washers are deemed to be included in the quoted rates.
145S & F in repairs Complete Wring harness system incl necessary elect connections for 15 to 125 KVA Capacity Kirloskar Make DG set complete all as directed.
146All as per item No 60here in before but of 160 to 320 KVA capacity
147S & F in repairs self starter push button / or with Key arrangement for DG starting suitable for Kirloskar / Cummins DG sets all as directed.
148S & F in repairs governer controller unit suitable for 320 KVA Capacity Kirloskar make DG sets incl neccessary connections and testing complete all as directed.
149S & F of distilled water in the DG battery all as directed.
150Supply and fix in repair changeover swithcs on load changeover switches 4 pole 400 Amps in sheet steel enclosure with inclosure as per the directions of Engineer-in-charge
151M & L for openingthe cylinder head of the engine and oil sump carefully for replacement of head gasketincluding sump gasketcomplete refixing the headand sump to arrest oil leakage with engine complete with proper alignment and testing the enginefor 1 hrson load to achiveve designed parameters all as directed by Engineer-in-Charge of capacity 15 KVA to 125 KVA.
152M & L for openingthe cylinder head of the engine and oil sump carefully for replacement of head gasketincluding sump gasketcomplete refixing the headand sump to arrest oil leakage with engine complete with proper alignment and testing the enginefor 1 hrson load to achiveve designed parameters all as directed by Engineer-in-Charge of capacity160 KVA to 320 KVA.
153Charges for attending break down of DG set of upto 500KVA capacity by only auth OEM rep /OEM trained engineer/ team for fault finding incl attending repairsas and when required such as No start condition of DG and repairing, starting the DG set till smooth running and setting up the alighnment / required paramenters of all major parts such as fan belt, AVR, RPM, sencors, actuators, Engine safety units, bty chargers, fuel / oli levels, speed governer,Micro processor based control panel, Injector pumps etc as required in ground / as ordered by EIC all as directed.
154All as per item No 68.00 here in before but of DG set capacity 15 to 250 KVA
155S&F VM Relay
156Preventive maintenance of AMF Panel for its smooth functioning and working performance , checking all electrical connection replacing the worn out electrical parts complete all as directed by engr-in-charge. (Note:- Spare parts will be measured and paid seprately under the relevant items.
157S&F of Relay card for DG set controller of any capacity
158S&F of Conatctor for 500A DG set
159S&F of Conatctor for 400A DG set
160S&F of Conatctor for 300A DG set
161S&F Of Contactor for 250A DG set
162S&F of Lockable trip push buttonof any capacity
163S&F of Locking of ACB in isolated position
164S&F of Locking of ACB in anyposition
165S&F of Shunt release (SR)FOR 24 V DC to 220 V DC for ACB
166S&F of Shunt release (SR)FOR 110V AC to 4150 V AC for ACB
167S&F of Under voltage releaseType MV : 24V DC / 240 V AC / 415 V AC for ACB
168Excavation in post holes in soft and loose soil n. exc 0.5 cum each and removing surplus soil to a diastance n exc 50m and making good surfaces etc complete all as specified and directed.
169Cement concrete in foundation filling and mass concrete Type D-2 (1:4:8) 40mm graded agrregates etc complete all as specified and directed.
170S& F Pre painted galvatume aluminium Zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding fixed with self taping screws as specified.
171M&L in replacement of steel work in tubularsection, rolled section as columns, posts including welding to plates, angles forming bases for columns and brackets for sheds etc complete all as specified.
172M&L for two coats of synthetic enamel paint over a coat of red oxide primer including preparation of newly or previously untreated surfaces on steel surfaces.
173Dismentalling of 320 kVAalternator from DG set, removing of Flywheel & replacement of flywheel ring gear with new one & refixing of all concern accessories properly as directed by engr-in-charge. (Ring gear will be measured extra as only supply item)
174Supply of flywheel ring gear complete.
175Dismantling and removing the carroded DG Set outer enclouser complete and then supply and fix new enclouser for 160 KVA DG Set conforming to CPCB Norms II , noise should not more than 75 dba @ 1 mtr , 1.6 mm thick and 16 SWG including diesel tank at bottom and aligning of alternator and diesel engine and all other connected works . ( Note :- The outer enclouser /canopy shall be fabricated as per CPCB norms -II from manufacturers / their authorised OEM)
176All as per item No 90 above here above but DG Set Capacity 15 KVA.
177Supply and fix in repair Thermostat for any make and any capacity complete all as specified and directed by Engr -in-Charge
178Supply and fix in repair watrer pump assy of capacity 63 KVA to 250 KVA of any make complete all as specified and directed by Engr -in-Charge
179Supply and fix in repair watrer pump assy of capacity 320 KVAof any make complete all as specified and directed by Engr -in-Charge

AI Tender Summary

OUR REF NO 43548940
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 39.90 Lakhs
LAST DATE 24-06-2024
Authority
Authority Name Military Engineer Services
Work Description Tender For Repairs Maintenances Of Dg Sets Amf Panels Servo Stabilizers And Connected Works At South North Side Runway At Hansa Vihar Under Age Em I Of Ge Nw Vasco
Basic Detail
Tender No 8615/E8
Bidding Type Tender
Location
City vasco
State Goa
Key Dates
Publish Date 04 Jun 2024
Submission Date 24 Jun 2024
Open Date 26 Jun 2024
Finance
Tender Value 39.90 Lakhs
Tender Fee 500
EMD 79800
Exemption Available
Document List
402dce41-e09d-4ea9-9d7d-87b0eb041ef5.html
8615TenderDocuments.pdf
BOQ_735393.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 04, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 24, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 26, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

402dce41-e09d-4ea9-9d7d-87b0eb041ef5.html

pdf

8615TenderDocuments.pdf

xls

BOQ_735393.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender