| 1 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 2 | a)1:5:10 (1 cement : 5 coarse sand(zone-III) including manufactured sand derived from Recycled concrete aggregate (RCA) up to 25% : 10 graded stone aggregate 40 mm nominal size including Recycled aggregate (RA)). |
| 3 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 4 | Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means. |
| 5 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.ird course of half brick masonry. |
| 6 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 7 | Granite of any colour and shade. Area of slab upto 0.50 sqm. Area of slab upto 0.50 sqm |
| 8 | Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II interior grade IS : 12823 marked, in shelves with screws and fittings wherever required, incl use of edge banding tape matching with PPB (fittings to be paid separately). 18mm thick |
| 9 | Providing slow motion box type hinges ISI marked IS : 3818 finished with nickel plating and fixing with necessary screws etc., complete. . |
| 10 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 11 | Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. |
| 12 | Providing and fixing aluminium/Brass sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete |
| 13 | a) 250x16 mm |
| 14 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete.a)300x10mm |
| 15 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete |
| 16 | a)100mm |
| 17 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 18 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer-in-charge. |
| 19 | Providing and fixing chromium plated brass curtain rods having wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : 20 mm dia. |
| 20 | Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Triple strip vertical type |
| 21 | Providing and fixing to existing door frames. :a) 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. |
| 22 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08%and conforming to IS: 15622, of approved brand & manufacturer in all colours and shade in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints. |
| 23 | Double Charged Vitrified tile polished finish of size.Size of Tile 600x600 mm |
| 24 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. |
| 25 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 26 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) |
| 27 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two or more coats. |
| 28 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 29 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Old work (one or more coats) |
| 30 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 32 | (a)One or more coats on old work. |
| 33 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 34 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. a) With cement mortar 1:4 (1 cement : 4 fine sand). |
| 35 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. |
| 36 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in-charge |
| 37 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres |
| 38 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge |
| 39 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 40 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 75 to 80 mm dia pipe. |
| 41 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 42 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : a) W.C. pan with ISI marked white solid plastic seat and lid |
| 43 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x460 mm bowl depth 200 mm. |
| 44 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 45 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : Flat back wash basin of size 550x400 mm. |
| 46 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall .a) 20 mm nominal outer dia. Pipes. |
| 48 | b) 25 mm nominal outer dia .Pipes |
| 49 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :a) 25 to 40 mm nominal bore |
| 50 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : a) 20 mm nominal bore |
| 51 | b) 25 mm nominal bore |
| 52 | Providing and fixing cPVC Union/cPVC nepple in G.I/cPVC pipe including cutting and threading the pipe and making long screws etc. complete (New work) a) 20 mm nominal bore |
| 53 | b) 25 mm nominal bore |
| 54 | Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms. |
| 55 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 56 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides |
| 57 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) (a)With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) |
| 58 | (b) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 59 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 60 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have minimum Humidity Resistance (RH) of 95%, minimum Light Reflectance = 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of minimum 0.30 mm thick (minimum galvanized @120 gsm) having rotary stitched double webbed white with 6mm reveal Silhouette profile (white/black) comprising of main T runners of minimum 15x32 mm of length 3000 mm, cross T of size minimum 15x32mm of length 1200 mm and secondary intermediate cross T of size minimum 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (minimum galvanised @ 80 gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size minimum 24x24X3000 mm made of minimum 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in charge. With 15 mm thick beveled tegular mineral fibre false ceiling tile (NRC minimum0.50) |
| 61 | Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge. |
| 62 | Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in- Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work |
| 63 | Providing and fixing 32 mm dia PVC rigid pipe forwash basin as waste pipe. The pipe shall be of length upto 600mm including P.V.C. waste fittings, P.V.C bend, union etc and fixing the pipewith clamps on wall surface, all as per site requirement, . All complete as directed by the Engineer in charge. |
| 64 | Providing and fixing C.P.Brass bib/ stop cock of Parryware Claret (T4604A1) makeor approved equivalent in toilets . The bibcocks are to be fixed by removing old bibcocks including making necessary adjustments. All complete as per directions of Engg-in-Charge. The rate is all inclusive nothing exra shall be paid on any account. a) 15mm dia nominal bore |
| 65 | Providing and fixing Swan neck C.P.Brass long body Pillar cock of Parryware Claretmake (T4668A1) or approved equivalent in toilets. The pillar cocks are to be fixed by removing old pillar cocks including making necessary adjustments wherever required all complete as per directions of Engg-in-Charge. a) 15mm dia nominal bore |
| 66 | Providing and fixing PVC SWR soil waste and vent pipes (by cutting, removing andreplacing existing damaged CI Sanitary Pipes wherever required)conforming to IS : 13592 Type B including jointing with \"T\" shaped seal/rubber ring conforming to IS : 5382 usingsolvent cement or rubber lubricant as the case may be with pipes of outer dia (concealed pipe joints to be jointed with rubber ring and solvent cement and exposed joints to be jointed with rubber ring and rubber lubricant). (i)Single socketed pipe(couplings,other accesories/Fittingswill be paid seperately)(a) 110mm diameter |
| 67 | (b) 75mm diameter |
| 68 | Providing and fixing PVC SWR pipefittings/Accessories conforming to IS : 14735 Type Bincluding cutting&replacing existing damaged CI fittings/accesories and jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion.a)Plain Bend(i)110mm diameter |
| 69 | (ii) 75mm diameter |
| 70 | (b) Tee with door (i) 110X110X110 |
| 71 | (ii) 75X75X75 |
| 72 | (c) Y- with door (i)110mm diameter |
| 73 | (ii) 75mm diameter |
| 74 | Providing and fixing of approved quality and colour etc. all operations complete as directed by the engineer in charge. a) Health faucet with wall support lever of 15mm nominal bore stainless steel/ CP brass nozzle jet and handle of approved quality and make for EWC |
| 75 | b) C.P. brasstwo in one bib cock 15 mm nominal boreof approved quality conforming to IS:8931: |
| 76 | Dismantlingpowder coated / anodized aluminium partitons, doors and other frames including proper numbering, loading and unloading and stacking by placing at the required place in the building premises etc. all operations complete as directed by the Engineer-in-charge . (Area of partition dismantled is measured for payment) |
| 77 | Making and fixing of aluminum partitions and doorsin position includingsorting outas per the drawingusingavailable material of aluminum sections, particle boards, glass panels, gasketsand snap on beadingincluding fixingwithrawl plugs, screws, expansion hold fasteners, filling up of gaps at junctions at top, bottom and sides with required PVC/Neoprene felt etc whereve required . Aluminum sectionsshall be mitered and jointedwherever required all complete as per the architectural drawings and as per the directions of the Engineer-in-charge. Necessary screws,clamps,Rawl plugs shall be arrangedfor fixing partitions . The available aluminium material, glass, boards,gaskets and snap on beadingwill be supplied by the department at no cost. Area of erected partition havingboard/glass panels/grill only shall be measured for payment) |
| 78 | Extra for powder coating (minimum thickness of polyester powder coating 50 micron) to all existing available dismantled/ removed aluminium partions consisting tubular/ box sections etc. including transportation from stores (within 10km from site of work)by mechanical transportation including loading and un-loading from stores to powder coating unit and back to work site as well asstacking at site including all incidental costs etc. as perthe directions of the Engineer-in-charge. ( Actual weight of thealuminium members ofthe erected partition will be measured mesured for payment.) |