| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 1 0 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. Ordinary rock |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1 . 5 m in width as well as 1 0 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. Hard rock (blasting prohibited) |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 4 | Extra for every additional lift of 1 . 5 m or part thereof in excavation I banking excavated or stacked materials. All kinds of soil |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1 :2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D ormore. |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D ormore. |
| 11 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 12 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V levelConcrete of M25 grade with minimum cementcontent of 330 kg /cum |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1 :4 (1 cement: 4 coarse sand) |
| 14 | Stone masonry work in cement mortar in foundation complete as per drawing and technicalspecifications Clauses 702, 704, 1202 & 1203. In 1:3 cement mortar |
| 15 | Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204.In 1:3 cement mortar |
| 16 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 17 | Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 18 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 19 | Providing and fixing cramps of required size & shape in RCC/ CC I Brick masonry backing with cement mortar 1 :2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately).Stainless steel cramps |
| 20 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 6 mm |
| 21 | Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 25 mm thick |
| 22 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat withapproved steel primer all complete. |
| 23 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes |
| 24 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade ofthe slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand): 25 mm thick |
| 25 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 26 | French spirit polishing :(Two or more coats on new works including a coat of wood filler) |
| 27 | Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. |
| 28 | Stone work (machine cut edges) for wall lining etc. upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Himalayan stone - exposed face fine dressed with rough backing 70 mm thick ( 450mm x 300mm) |
| 29 | Stone work (machine cut edges) for wall lining etc. upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Himalayan stone - exposed face fine dressed with rough backing 50 mm thick ( 450mm x 200mm) (Wall Cladding Stone) |
| 30 | Providing and fixing second class deodar wood hand rail having size of 75 mm x 65 mm with approved decorative shape etc. |
| 31 | Providing and fixing Deodar Woodceiling in 25 mm thick 150 mm wide deodar wood plank. |
| 32 | Providing and fixing Deodar WoodJhalar (Manually Hand Carved) in 25 mm thick 300 mm wide deodar wood plank. |
| 33 | Two or more coats on new works including a coat of wood filler Hydro Oil For Exterior Coating |
| 34 | Supply, transportation, installation, fitting & fixing and supervision of Laminated Asphalt Shingles havingmultilayer Panel produce three dimensional profile and shadow lines with fiber glass mat, Waterproof, durable coating, temper proof, 110mph wind resistance, UL Class-A, fire resistance rating, exposure 5.5/8 inch, weight up to 450 Pound/ 100 Sqft. Or more, high end products last 30 years & more as per instructions laid on ASTM D3462, ASTM D3018, ASTM D7158-Class-H.The Laminated Asphalt Shingles as per specifications must be laid in proper way over 20mm Cement Fiber Board Make - Everest or Equivalent. and moisture barrier membrane and Algae resistant Ridge with all required fixtures & fastenings as a complete job as per instructions and satisfaction of Engineer-in-charge with contractors’ own material, labour, tools, lead, lift, T&P, etc. The design and methodology to be approved by Eingeer-in-charge prior commencement of the work. The rate included cost of materials, transportation to site, installation, fixing, pegging, pre-installation preparation works, supervision, petty works involved, taxes, GST, etc. as a compete job. |
| 35 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawingsand technical specifications Clause 802, 803, 1202 & 1203 (P.C.C. grade M 20)Nominal mix (1:2:4) |
| 36 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 37 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes |
| 38 | Providing and laying of stone set pavement over 2.5 cm thick bedding layer of PCC 1:2:4 which shall further be placed over 10 cm thick dry stone kharanja or crushed stones base over a prepared subgrade as per drawings and technical specifications. The size of stones shall not be less than 20 cm x 20 cm and thickness of stones shall vary from 10 cm to 15 cm. The work includes filling of joints with PCC 1:2:4 as per the standard drawings and instructions of the Engineer-in-Charge. |
| 39 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 40 | Providing and fixing second class deodar wood hand rail having size of 75 mm x 65 mm with approved decorative shape etc. |
| 41 | Two or more coats on new works including a coat of wood filler Hydro Oil For Exterior Coating |
| 42 | Supply, Installation,testingandcommissioning of IP 43 rated EXT. LTG. PANEL FOR TREKROUTE (PART-1)Having, Incomer: 25 Amp FP 10KA MCB (01 No).1 NO SPD1 NO MFM WITH RS485 PORT1 NO. DIGITAL VOLTMETER WITH VOLTAGE SELECTOR SWITCH1 NO. DIGITAL AMP METER WITH AMETER SELECTOR SWITCHINDICATION LAMP- 6 NOS (R,Y,B,ON,OFF,TRIP)CT, 25/5A, CL-1,10VA AUTO MANUAL SWITCH WITH SINGLE CHANNEL DIGITAL TIMER WITH 48HR BATTERY BACK-UP AUTO-MANUAL BY-PASS SWITCH25 Amp FP 10KA MCB WITH 25A, TP HEAVYDUTY CONTACTOROut Going: F1 TO F12 -16 Amp FP 10KA MCB (12NOS.)F13 TO F15 -16 Amp DP 10KA MCB (03NOS.) ALSO REFER SLD & DETAIL TECHNICAL SPECIFICATION ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. |
| 43 | Supply, Installation,testingandcommissioning of IP 43 rated EXT. LTG. PANEL FOR TREKROUTE (PART-2)Having, Incomer: 25 Amp FP 10KA MCB (01 No). 1 NO SPD1 NO MFM WITH RS485 PORT1 NO. DIGITAL VOLTMETER WITH VOLTAGE SELECTOR SWITCH1 NO. DIGITAL AMP METER WITH AMETER SELECTOR SWITCHINDICATION LAMP- 6 NOS (R,Y,B,ON,OFF,TRIP)CT, 25/5A, CL-1,10VA AUTO MANUAL SWITCH WITH SINGLE CHANNEL DIGITAL TIMER WITH 48HR BATTERY BACK-UP AUTO-MANUAL BY-PASS SWITCH25 Amp FP 10KA MCB WITH 25A, TP HEAVYDUTY CONTACTOROut Going: F1 TO F8 -16 Amp FP 10KA MCB (06NOS.)F9 & F10 -16 Amp DP 10KA MCB (02NOS.) ALSO REFER SLD & DETAIL TECHNICAL SPECIFICATION ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. |
| 44 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 45 | Supplying and fixing of weatherproof enclosure for double pole, 240 volts, MCB (6A-32A) complete with connections, testing and commissioning etc. as required.Approved Makes-LEGRAND / SCHNIEDER/ SIEMENS / L&T / ABB / equivalent make |
| 46 | Laying of PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existingRCC/ HUME/ METAL/DWC pipe as required. Upto 35 sq. mm |
| 47 | Laying and fixing of PVC insulated and PVC sheathed / XLPE powercable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 48 | Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductorArmoured / Flexible cables as per specification & IS.The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid insidethe building as instructed by PMC/Site Incharge. The scope shall include:Approved Makes- FINOLEX / POLYCAB / RR KABEL /KEI / HAVELLS / equivalent make 4C x 6 Sq.mm. CU XLPE armored cable |
| 49 | Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductorArmoured / Flexible cables as per specification & IS.The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid insidethe building as instructed by PMC/Site Incharge. The scope shall include:Approved Makes- FINOLEX / POLYCAB / RR KABEL /KEI / HAVELLS / equivalent make 4C x 6 Sq.mm. CU XLPE armored cable |
| 50 | Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductorArmoured / Flexible cables as per specification & IS.The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid insidethe building as instructed by PMC/Site Incharge. The scope shall include:Approved Makes- FINOLEX / POLYCAB / RR KABEL /KEI / HAVELLS / equivalent make 3C x 4 Sq.mm. CU XLPE armored cable |
| 51 | Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductorArmoured / Flexible cables as per specification & IS.The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid insidethe building as instructed by PMC/Site Incharge. The scope shall include:Approved Makes- FINOLEX / POLYCAB / RR KABEL /KEI / HAVELLS / equivalent make 3C x 2.5 Sq.mm. CU XLPE armored cable |
| 52 | Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination andEarthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI / equivalent make -4C x 6 Sq.mm. CU XLPE armored cable |
| 53 | Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination andEarthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI / equivalent make -4C x 4 Sq.mm. CU XLPE armored cable |
| 54 | Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination andEarthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI / equivalent make -3C x 4 Sq.mm. CU XLPE armored cable |
| 55 | Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination andEarthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI / equivalent make -3C x 2.5 Sq.mm. CU XLPE armored cable |
| 56 | Point wiring in PVC conduit, with modular type switch: Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required- Group C |
| 57 | Brass holder Supplying and flxing brass batten/angle holder including connection etc. as required. |
| 58 | Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the samein case of recessed conduit as required. -32 mm |
| 59 | Supply, installation, testing and commissioning of following sizes of Heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32mm |
| 60 | S/L SWG GI wire in ground:Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required |
| 61 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. |
| 62 | Supply, Installation, Testing and Commissioning of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 25.0 mm with copper coating thickness of 250micron tested as per IEC 62561-2 + Universal clamp (SS), 25mm + Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested OEC 2 25 + The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Under floor earth inspection pit. Cost include to have earth pit cover, testing of all things, etc. in all complete manner. Approved Makes-OBO/ JEFF/ JMV |
| 63 | Weather Proof Downlighter : Supplyof CEILING LED Fixture -LED 12W,LED Electronic Driver which offers Protection against Short Circuit, Over- Voltage& Over- Current, IP 66 protection,CRI > 70,voltage input AC100-240V.Body-Die-casting and Extruded aluminium Body with Surface Anti-ageing electrostatic spray processing & screen. Body colour-RAL 9005 Matt ,Dimension-126mm(Dia.)x138mm(H),Weight-0.75kgs. Estimated Lifetime-L70 @ 50,000hours minimum.* Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Make - NERI/Philips/Lighting Technologies |
| 64 | Landscape BollardSupply, laying, connection and testing of Landscape Bollards 15Watts Bollard LED, IP66, 800/100mm. * Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Make - NERI/Philips/Lighting Technologies |
| 65 | 35W LED Solar Streetlight:Supply of all in one integrated LED solar streetlight consists of solar photovoltaic module,battery,batterymanagement system, control electronics, LED driver, InbuiltSensor,inter-connectingcables and pole mounting piece integrated into the luminaire as a single unit. Solar street light with IP65 ingress protection havingasystemwattageof35Wwith 6000 lumen output, 60Wp high efficiencymonocrystallinesolarpanel, highly efficient MPPT based charge controller and 12.8 V, 30 Ah IP68 LithiumFerroPhosphate(LiFePO4) batterywithproperbattery management system. LED lumen efficacy shall be at least 175lm/W and LED driver should have >90% efficiency. Typicalcorrelatedcolourtemperature should be 3000/5700K with CRI>70. It should ensurebatteryoptimisationwithhelp of a suitable dimming profile. The luminaire shall have inbuilthybrid powersupplyoptionthatcancharge the battery during non sunny days automaticallyfromthegrid.The luminaireshouldbehousedinIK08 impactresistancecertifiedaluminum pressure diecast housing with anti- corrosivecoatingandmusthaveaUV stabilized polycarbonate cover. The luminaire shall have a specially designed pole mounting piece that enables lateral as well as post top mounting and installation at varying tiltsfrom0to15degreesforoptimal light distribution.* Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Makes-Philips/Wipro/Havells |
| 66 | Supply, erection testing and commissioning of6M HEIGHT SINGLE ARM OCTAGONAL POLE 6M height Single arm Conical Pole made in combination of Octagonal Conical section which is fabricated from High tensile MS Sheet(3mm thick) with top 48 to 60mm A/F and bottom 130mm A/F. Arm made of steel pipe section 60mm dia.( horizontal)to get 1000mm arm length & pleasing aesthetics. The pole to be provided with a steel base plate of 200mmx200mmx12mm thick minimum. This mounting steel base plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. Entire pole & bracket shall be made to provide pleasing aesthetics as approved by Concerned Engineer in-charge. After Fabrication, Entire Pole is hot dip galvanized(60 microns Minimum ) for the effective corrosion resistance . The hot dip Galvanised pole should be provided with an inbuilt junction box to fix 32A connectors and 6A MCB, at the bottom- the inbuilt box should have a flush door of suitable size. wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole strength. Pole & it\"s partsare painted in 3 layer coating(coating thickness-100 microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy primer & 3rd final layer with PU paint.* Colour of Pole shall be as per Architectural requirements.Approved Make - NERI/Transrail / Bajaj / Volmont |
| 67 | Supply, Transportation, Installation, testing and commissioning of IP 67 weather proof Outdoor type junction boxes with terminal block/connector. Equivalent to Hensel catalogue no KF 1006 G/OBO/CAPE |
| 68 | Supply, Transportation, Installation, testing and commissioning of IP 67 weather proof Outdoor type junction boxes with terminal block/connector. Equivalent to Hensel catalogue no KF 1610 G/OBO/CAPE |
| 69 | Supply, Transportation, Installation, testing and commissioning ofIP 67 weather proof Outdoor type junction boxes with terminal block/connector. Equivalent to Hensel catalogue no KF 1616 G/OBO/CAPE |
| 70 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. -120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 71 | Providing & Laying of HDPE Pipe 32mm PE-80,PN6 direct in ground; to be laid 75-100cm below the ground level for drawing of cables including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering,or G.I. conduit 32 mm dia( Heavy Duty) with concrete block 15cm X 15cm 1:2:4 with complete curing with splicing complete in all respect complete in all respect. Make: Jain/Dutron/Supreme/reliance |
| 72 | Liaison with Local Electricity board for Permanent Electrical Power Getting Approval from Licensee, Electrical Inspector - IM & E Dept. The scope includes to get the required power complete with providing necessary drg/document/arrangingvisit etc from requirement of statutory authority. The payment towards official payment shall be reimbursedagainst receipt of such payment. |
| 73 | EM-C-450x450x500mm ELECTRICAL& ELV MANHOLE -Construction of RCC manhole With FRP surface heavy duty chamber cover with Frame &RCC top slab FOR SEWER |
| 74 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soils / ordinary rock |
| 75 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 Kgs/CuM. Excess/ less cement used as per design mix is payable/recoverable separately). |
| 76 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 77 | Form Work : Centring and Shuttering for Foundations, footings, bases of columns, etc. for mass concrete |
| 78 | Centring and Shuttering for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 79 | Centring and Shuttering for Suspended floors, roofs, landings, balconies and access platform |
| 80 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |