Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #43521612

Tender For Repair/Replacement Of Switchgear, Looping Box, Changeover Switch And All Other Connected Misc Accessories At Tech Area And Vsv Area At Af Station Under Ge (Af) Tughlakabad

Issued by Statutory Bodies & Commissions/Committees · tughlakabad, Delhi
Tender Value
28 Lakhs
Estimated cost
Bid Submission
29 Jun 2024
0 days left
EMD
56000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tughlakabad → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Repair/Replacement Of Switchgear, Looping Box, Changeover Switch And All Other Connected Misc Accessories At Tech Area And Vsv Area At Af Station Under Ge (Af) Tughlakabad

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Jun-2024 Corrigendum No 1 BOQ 22-Jun-2024
2 22-Jun-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-Jun-2024

BOQ

Name of Work: REPAIR/REPLACEMENT OF SWITCHGEAR, LOOPING BOX, CHANGEOVER SWITCH AND ALL OTHER CONNECTED MISC ACCESSORIES AT TECH AREA AND VSV AREA AT AF STN UNDER GE (AF) TUGHLAKABAD
Sl. No. Item Description
1S&Fin replacement of PVC cable loop box, size not less than 145mm x 145mm x 95mm, out door type, duly fitted to poles with suitable clamp, nuts, bolts & washers including one No of 6to 32 Amps single pole MCB, porcelain insulated connectors for incoming and outgoing cables complete all as specified and directed by Engr-in-charge
2S&F in replacement MCCB 4 Pole 160 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
3S&F in replacement MCCB 4 Pole 250 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
4S&F in replacement MCCB 4 Pole 400 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KAcomplete all as specified and directed by Engr-in-charge
5S&F in replacement MCCB 4 Pole 630 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
6S&F in replacement MCCB 4 Pole 125 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
7S&F in replacement MCCB 4 Pole 63 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
8S&F in replacemen of ACB 4 Pole, 415 V, 630 amps commissioning and testingwith Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps complete all as specified and directed by Engr-in-charge
9S&F in replacemen of ACB 4 Pole, 415 V, 800 amps commissioning and testing with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Ampscomplete all as specified and directed by Engr-in-charge
10S&F in replacemen of ACB 4 Pole, 415 V, 1600 amps commissioning and testing with Thermal Magnetic Release (Manual Fixed type) of capacity 1600 Ampscomplete all as specified and directed by Engr-in-charge
11S&F in replacement ofLED highbay light 150 watts surround type suitable for 240 volts , 50 HZs single phase power supply , fabricated with die cast aluminium with high power LEDs as light source, IP 66 complete with all standered accessories complete all as specified and directed by Engr-in-charge
12S&Fin replacement of LED highbay light 100 watts surround type suitable for 240 volts , 50 HZs single phase power supply , fabricated with die cast aluminium with high power LEDs as light source ,IP 66 complete with all standered accessories complete all as specified and directed by Engr-in-charge
13S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
14S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
15S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
16S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 350 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
17S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 400 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
18S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 630 Amps with breaking capacity 50 KAcomplete all as specified and directed by Engr-in-charge
19S&F in replacementof MCB TPN4 pole 16 to 32 amp 415 volt, ;C; curve 10 KA breaking capacity complete all as specified and directed by Engr-in-charge
20S&F in replacementof MCB TPN 4 pole40to 63 amp 415 volt;C; Curve 10 KA breaking capacity complete all as specified and directed by Engr-in-charge
21S&F in replacementof MCB SPN 4 pole32 to 63 amps 240\"C\" curve volt 10 KA breaking capacity complete all as specified and directed by Engr-in-charge
22S&F in replacement of ON-Load changeover switch320 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge
23S&F in replacement of ON-Load changeover switch 200 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge
24S&F in replacement of ON-Load changeover switch400amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge
25S&F in replacement of OFF-Load changeover switch320 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge
26S&F in replacement of OFF-Load changeover switch 200 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge
27S&F in replacement of OFF-Load changeover switch400amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge
28Supply and fixing LED light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable complete all as specified and directed by Engr-in-charge
29Supply and fixingin replacement of LED light fitting2x8 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable complete all as specified and directed by Engr-in-charge
30S&F in replacement of switch flame proof rotary type with termination box in LM6, 16A, single pole 250Vcomplete all as specified and directed by Engr-in-charge
31M & L in replacement of APFC 150 KVAR panel in replacement cubical consist of sheet metal steel enclosure of 2 mm thick tottaly enclosed dust proof duly painted with powder coated fully wired up and ready to connect lead & control linescommissioning and testing complete all as specified and directed by Engr-in-charge comprising the following:(i) MCCB 250 A 25 KA 3 pole thermal -1 nos (ii) Capacitor duty contactor for 20 KVAR - 04 nos (iii) Capacitor duty contactor for 10 KVAR - 04 nos (iv) Capacitor duty contactor for 5 KVAR - 06 nos (v) Capacitor 20 KVAR - 4 nos (vi) Capacitor 10 KVAR - 04 nos (vii) Capacitor 5 KVAR -06 nos (viii) MCB 63 A 10 KA TP for 20 KVAR - 4 nos (ix) MCB 25 A 10 KA TP for 10 KVAR - 4 nos (x) MCB 16 A 10 KA TP for 5 KVAR - 06 nos (xi) APFC Relay 12 stage - 1(xii) Indicating light red - 01 no(xiii) Auto manual selector switch - 11 nos(xiv) Digital volt meter (0-500 V) - 1(xv) Digital amp meter (0-160 A) - 1 no(xvi) Volt meter selector switch - no(xvii) Amp meter selector switch - 1 no(xviii) Indicator light R Y B - 3 nos(xix) CT 160/5 A - 3 nos (xx) Bus bar 200 A 3 strip & N/L 200 A ALU-01 set
32S&F in replacement of 3 pole power contactorMNX 325,current rating 600 amp amp 415 volt AC coil voltage 110/220/415 volt AC 50 HZ complete all as specified and directed by Engr-in-charge
33M & L in replacement of APFC 100 KVAR panel in replacement cubical consist of sheet metal steel enclosure of 2 mm thick tottaly enclosed dust proof duly painted with powder coated fully wired up and ready to connect lead & control lines commissioning and testing complete all as specified and directed by Engr-in-charge comprising the following:(i) MCCB 160 A 25 KA 3 pole thermal -1 nos(ii) Capacitor duty contactor for 20 KVAR - 02 nos(iii) Capacitor duty contactor for 10 KVAR - 03 nos(iv) Capacitor duty contactor for 5 KVAR - 06 nos(v) Capacitor 20 KVAR - 2 nos(vi) Capacitor 10 KVAR - 03 nos(vii) Capacitor 5 KVAR -06 nos(viii) MCB 63 A 10 KA TP for 20 KVAR - 2 nos(ix) MCB 25 A 10 KA TP for 10 KVAR - 3 nos(x) MCB 16 A 10 KA TP for 5 KVAR - 06 nos(xi) APFC Relay 12 stage - 1(xii) Indicating light red - 01 no(xiii) Auto manual selector switch - 11 nos(xiv) Digital volt meter (0-500 V) - 1(xv) Digital amp meter (0-160 A) - 1 no(xvi) Volt meter selector switch - no(xvii) Amp meter selector switch - 1 no(xviii) Indicator light R Y B - 3 nos(xix) CT 160/5 A - 3 nos (xx) Bus bar 200 A 3 strip & N/L 200 A ALU-01 set
34S&F in replacement of A one 4 Kg ABC powder type fire Exitinguisher with wall mounted complete all as specified and directed by Engr-in-charge
35Supply and fixing inreplacement ofdigital Voltmeter of range 0-500 Volts single phase, Class 01 of size 96 x 96mm suitable for existing LT panel complete all as specified and directed by Engr-in-charge.
36Supply and fixing in replacement of digital Amp meterof range 0-300 Amps alongwith suitable ratio of CTs,single phase, class 01 of size 96 X 96mm suitable for existing LT panel complete all as specified and directed by Engr-in-charge
37Supply and fixingin replacement of flame proof exhaust fan & 300mm sweep, 230V, 1440 rpm, CMRI certified recommended recommended for gas/vapor group of Iia & IIIB, Zone 1 & 2 and IP 65 protection with flame & heat resistant body material complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size incl cutting of holes, complete all as specified and directed by Engr-in-charge
38Supply and fixing in replacement of Automatic transfer switch of capacity 400 Amp 4 pole,AC-31 A,50 HZ,415 V automatic/ manual with inbuilt time delay complete all as specified and as directed by Engr-in-charge.
39Supply and fixing in replacement of Automatic transfer switch of capacity 200 Amp 4 pole,AC-31 A,50 HZ,415 V automatic/ manual with inbuilt time delay complete all as specified and as directed by Engr-in-charge.
40S&F in replacement of MCCB 4 Pole 1000 amps alongwith spreader/link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
41S&F in replacementof MCCB 4 Pole 800 amps alongwith spreader/link, 415 V,with Microprocessor release with breaking capacity 36 KAcomplete all as specified and directed by Engr-in-charge

AI Tender Summary

OUR REF NO 43521612
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 28 Lakhs
LAST DATE 29-06-2024
Authority
Authority Name Military Engineer Services
Work Description Tender For Repair/Replacement Of Switchgear, Looping Box, Changeover Switch And All Other Connected Misc Accessories At Tech Area And Vsv Area At Af Station Under Ge (Af) Tughlakabad
Basic Detail
Tender No GE/TKD-15/2024-25
Bidding Type Tender
Location
City tughlakabad
State Delhi
Key Dates
Publish Date 22 Jun 2024
Submission Date 29 Jun 2024
Open Date 01 Jul 2024
Finance
Tender Value 28 Lakhs
Tender Fee 500
EMD 56000
Exemption Available
Document List
3522b801-d2e1-45a3-ac80-6d8ffe234f12.html
BOQ_735221.xls
Tender15.pdf
Tender15Phase1Materials.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 22, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 22, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 29, 2024
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 29, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 01, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

3522b801-d2e1-45a3-ac80-6d8ffe234f12.html

xls

BOQ_735221.xls

pdf

Tender15.pdf

pdf

Tender15Phase1Materials.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders