Tender For Repair/Replacement Of Switchgear, Looping Box, Changeover Switch And All Other Connected Misc Accessories At Tech Area And Vsv Area At Af Station Under Ge (Af) Tughlakabad
Tender Overview
Project Description
Tender For Repair/Replacement Of Switchgear, Looping Box, Changeover Switch And All Other Connected Misc Accessories At Tech Area And Vsv Area At Af Station Under Ge (Af) Tughlakabad
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-Jun-2024 | Corrigendum No 1 | BOQ | 22-Jun-2024 |
| 2 | 22-Jun-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-Jun-2024 |
BOQ
| Sl. No. | Item Description |
| 1 | S&Fin replacement of PVC cable loop box, size not less than 145mm x 145mm x 95mm, out door type, duly fitted to poles with suitable clamp, nuts, bolts & washers including one No of 6to 32 Amps single pole MCB, porcelain insulated connectors for incoming and outgoing cables complete all as specified and directed by Engr-in-charge |
| 2 | S&F in replacement MCCB 4 Pole 160 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge |
| 3 | S&F in replacement MCCB 4 Pole 250 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge |
| 4 | S&F in replacement MCCB 4 Pole 400 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KAcomplete all as specified and directed by Engr-in-charge |
| 5 | S&F in replacement MCCB 4 Pole 630 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge |
| 6 | S&F in replacement MCCB 4 Pole 125 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge |
| 7 | S&F in replacement MCCB 4 Pole 63 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge |
| 8 | S&F in replacemen of ACB 4 Pole, 415 V, 630 amps commissioning and testingwith Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps complete all as specified and directed by Engr-in-charge |
| 9 | S&F in replacemen of ACB 4 Pole, 415 V, 800 amps commissioning and testing with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Ampscomplete all as specified and directed by Engr-in-charge |
| 10 | S&F in replacemen of ACB 4 Pole, 415 V, 1600 amps commissioning and testing with Thermal Magnetic Release (Manual Fixed type) of capacity 1600 Ampscomplete all as specified and directed by Engr-in-charge |
| 11 | S&F in replacement ofLED highbay light 150 watts surround type suitable for 240 volts , 50 HZs single phase power supply , fabricated with die cast aluminium with high power LEDs as light source, IP 66 complete with all standered accessories complete all as specified and directed by Engr-in-charge |
| 12 | S&Fin replacement of LED highbay light 100 watts surround type suitable for 240 volts , 50 HZs single phase power supply , fabricated with die cast aluminium with high power LEDs as light source ,IP 66 complete with all standered accessories complete all as specified and directed by Engr-in-charge |
| 13 | S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge |
| 14 | S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge |
| 15 | S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge |
| 16 | S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 350 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge |
| 17 | S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 400 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge |
| 18 | S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 630 Amps with breaking capacity 50 KAcomplete all as specified and directed by Engr-in-charge |
| 19 | S&F in replacementof MCB TPN4 pole 16 to 32 amp 415 volt, ;C; curve 10 KA breaking capacity complete all as specified and directed by Engr-in-charge |
| 20 | S&F in replacementof MCB TPN 4 pole40to 63 amp 415 volt;C; Curve 10 KA breaking capacity complete all as specified and directed by Engr-in-charge |
| 21 | S&F in replacementof MCB SPN 4 pole32 to 63 amps 240\"C\" curve volt 10 KA breaking capacity complete all as specified and directed by Engr-in-charge |
| 22 | S&F in replacement of ON-Load changeover switch320 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge |
| 23 | S&F in replacement of ON-Load changeover switch 200 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge |
| 24 | S&F in replacement of ON-Load changeover switch400amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge |
| 25 | S&F in replacement of OFF-Load changeover switch320 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge |
| 26 | S&F in replacement of OFF-Load changeover switch 200 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge |
| 27 | S&F in replacement of OFF-Load changeover switch400amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge |
| 28 | Supply and fixing LED light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable complete all as specified and directed by Engr-in-charge |
| 29 | Supply and fixingin replacement of LED light fitting2x8 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable complete all as specified and directed by Engr-in-charge |
| 30 | S&F in replacement of switch flame proof rotary type with termination box in LM6, 16A, single pole 250Vcomplete all as specified and directed by Engr-in-charge |
| 31 | M & L in replacement of APFC 150 KVAR panel in replacement cubical consist of sheet metal steel enclosure of 2 mm thick tottaly enclosed dust proof duly painted with powder coated fully wired up and ready to connect lead & control linescommissioning and testing complete all as specified and directed by Engr-in-charge comprising the following:(i) MCCB 250 A 25 KA 3 pole thermal -1 nos (ii) Capacitor duty contactor for 20 KVAR - 04 nos (iii) Capacitor duty contactor for 10 KVAR - 04 nos (iv) Capacitor duty contactor for 5 KVAR - 06 nos (v) Capacitor 20 KVAR - 4 nos (vi) Capacitor 10 KVAR - 04 nos (vii) Capacitor 5 KVAR -06 nos (viii) MCB 63 A 10 KA TP for 20 KVAR - 4 nos (ix) MCB 25 A 10 KA TP for 10 KVAR - 4 nos (x) MCB 16 A 10 KA TP for 5 KVAR - 06 nos (xi) APFC Relay 12 stage - 1(xii) Indicating light red - 01 no(xiii) Auto manual selector switch - 11 nos(xiv) Digital volt meter (0-500 V) - 1(xv) Digital amp meter (0-160 A) - 1 no(xvi) Volt meter selector switch - no(xvii) Amp meter selector switch - 1 no(xviii) Indicator light R Y B - 3 nos(xix) CT 160/5 A - 3 nos (xx) Bus bar 200 A 3 strip & N/L 200 A ALU-01 set |
| 32 | S&F in replacement of 3 pole power contactorMNX 325,current rating 600 amp amp 415 volt AC coil voltage 110/220/415 volt AC 50 HZ complete all as specified and directed by Engr-in-charge |
| 33 | M & L in replacement of APFC 100 KVAR panel in replacement cubical consist of sheet metal steel enclosure of 2 mm thick tottaly enclosed dust proof duly painted with powder coated fully wired up and ready to connect lead & control lines commissioning and testing complete all as specified and directed by Engr-in-charge comprising the following:(i) MCCB 160 A 25 KA 3 pole thermal -1 nos(ii) Capacitor duty contactor for 20 KVAR - 02 nos(iii) Capacitor duty contactor for 10 KVAR - 03 nos(iv) Capacitor duty contactor for 5 KVAR - 06 nos(v) Capacitor 20 KVAR - 2 nos(vi) Capacitor 10 KVAR - 03 nos(vii) Capacitor 5 KVAR -06 nos(viii) MCB 63 A 10 KA TP for 20 KVAR - 2 nos(ix) MCB 25 A 10 KA TP for 10 KVAR - 3 nos(x) MCB 16 A 10 KA TP for 5 KVAR - 06 nos(xi) APFC Relay 12 stage - 1(xii) Indicating light red - 01 no(xiii) Auto manual selector switch - 11 nos(xiv) Digital volt meter (0-500 V) - 1(xv) Digital amp meter (0-160 A) - 1 no(xvi) Volt meter selector switch - no(xvii) Amp meter selector switch - 1 no(xviii) Indicator light R Y B - 3 nos(xix) CT 160/5 A - 3 nos (xx) Bus bar 200 A 3 strip & N/L 200 A ALU-01 set |
| 34 | S&F in replacement of A one 4 Kg ABC powder type fire Exitinguisher with wall mounted complete all as specified and directed by Engr-in-charge |
| 35 | Supply and fixing inreplacement ofdigital Voltmeter of range 0-500 Volts single phase, Class 01 of size 96 x 96mm suitable for existing LT panel complete all as specified and directed by Engr-in-charge. |
| 36 | Supply and fixing in replacement of digital Amp meterof range 0-300 Amps alongwith suitable ratio of CTs,single phase, class 01 of size 96 X 96mm suitable for existing LT panel complete all as specified and directed by Engr-in-charge |
| 37 | Supply and fixingin replacement of flame proof exhaust fan & 300mm sweep, 230V, 1440 rpm, CMRI certified recommended recommended for gas/vapor group of Iia & IIIB, Zone 1 & 2 and IP 65 protection with flame & heat resistant body material complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size incl cutting of holes, complete all as specified and directed by Engr-in-charge |
| 38 | Supply and fixing in replacement of Automatic transfer switch of capacity 400 Amp 4 pole,AC-31 A,50 HZ,415 V automatic/ manual with inbuilt time delay complete all as specified and as directed by Engr-in-charge. |
| 39 | Supply and fixing in replacement of Automatic transfer switch of capacity 200 Amp 4 pole,AC-31 A,50 HZ,415 V automatic/ manual with inbuilt time delay complete all as specified and as directed by Engr-in-charge. |
| 40 | S&F in replacement of MCCB 4 Pole 1000 amps alongwith spreader/link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge |
| 41 | S&F in replacementof MCCB 4 Pole 800 amps alongwith spreader/link, 415 V,with Microprocessor release with breaking capacity 36 KAcomplete all as specified and directed by Engr-in-charge |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender