| 1 | Taking down existing waterproofing tratment complete of any description from brick or RCC wall and RCC slab by scrapping including removal of rubbish where directed to a distance not exceeding 100m all as specified and as directed by Engr-in-Charge and applying water proofing treatment to roof as per per manufacturer\"s instructionswith the following specification:-.(a) 15 mm thick plastering in cement mortar 1:4 mixed with and including water proofing compound @3% by weight of cement including preperation ofroof surfaces.(b) Applying evenly a coat of bitumineous primer @ 0.5 litre per Sqm(c) Applyingevenly a coat of hot blow bitumen 85/25 grade @ 1.2 Kg per Sqm (d)Applying APP based polymeric membrane minimum 3 mm thick and minimum weighing 3kg/sqmlaid on primed surface by LPG forced torch application with a side & end overlaps of minimum 100 mm.(e) Applyingevenly a coat of hot blown bitumen 85/ 25 grade @ 1.2 Kg per Sqm over water proofing membrane (f)Applying a coat of bituminous basedaluminium primer @ 100 gm/Sqm on top including sealing all joints by thermo fusion complete all as per manufacturer\"s instructions |
| 2 | Supply only water proofing compound. |
| 3 | Taking down cement plaster of any description on brick or stone walls, ceilings, fins, fascias, chajjas, parapets etc. (including tiles) raking outjoint, hacking for key, scrubbing down with water etc incl patches of any size complete all as specified and directed by Engr-in-Charge. |
| 4 | M & Lfor 15 mm thick cement plasterin CM 1:4brick work or concrete surfaces mixed with water proofing compound 3% by weight of cement shall befinished even andsmooth without using extra cementcomplete all as specified and directed by Engr-in-Charge. |
| 5 | M & L for 10mm thick cement plaster on fair faces of brick or concrete surface in cementmortar ( 1:6) finished even andsmooth without using extra cementcomplete all as specified and directed by Engr-in-Charge. |
| 6 | M&L for 5 mm thick rendering in CM 1:3 on ceiling including finishing the surfaces even and smooth, without using extra cement etc complete all as specified and directed by Engr-in -charge. |
| 7 | M&L for preparation of new plastered external wall surfaces of any description over 10 cm width/girth and including applying two coat of weather coat anti dust emulsion paint, exterior grade of approved shade over a coat of alkali guard anti efflorescence primer as per manufacturer\"s instruction complete all as specified and directed by Engineer -in - Charge. |
| 8 | M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coat oil bound distemper over a coat ofalkali resistant primer complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for preparation of newly plastered or unplastered surfaces of wall and applying three coat white wash complete all as specified and directed by Engr-in-Charge. |
| 10 | M&L for preparation of newly plastered or unplastered surfaces of ceilings and applying three coat white wash complete all as specified and directed by Engr-in-Charge. |
| 11 | Demolition of brick work/stone masonry built in cement mortar and removal of rubbish from site complete all as specified and directed. |
| 12 | M&L for brick work with fly ash bricks, straight or curved on plain exc 6m mean radius built in cement mortar 1:6. |
| 13 | M&L for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) |
| 14 | Taking down and Refixing old 25mm dia bore of steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)complete all as specified and directed by Engr-in-Charge. |
| 15 | -ditto- all as per above item but 20mm bore |
| 16 | -ditto- all as perabove item but 15mm bore |
| 17 | S&F in repairs 25 mm bore galvanized medium grade tubing fixed / laid in trenchesalong walls / celing etc complete all as specified and directed by Engr-in -charge. |
| 18 | S&F in repairs 20 mm bore galvanized medium grade tubing fixed / laid in trenchesalong walls / celing etc complete all as specified and directed by Engr-in -charge. |
| 19 | S&F in repairs 15 mm bore medium grade GI tubing including all fittings and fixed in position to walls, ceiling or under floors etc complete all as specified and directed by Engr-in -charge. |
| 20 | S&F in repairs 4 mm thick PVC coated GI wire rope for hanging cloths including fixing arrangement with steel member (as per sample) complete all as specified and as directed |
| 21 | Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level) as in repairs. |
| 22 | M & L for75mm thick PCC type C2 1:3:6 (40mm garade aggregate) as in plinth protection complete all as specified and directed |
| 23 | S&F in repairs 75 mm dia PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed |
| 24 | S&F in repairs PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed by Engr-in -charge. |
| 25 | S&F in repairs 75mm bore PVC (SWR) junction single (Single T) equal or unequal complete all as specified & directed. |
| 26 | Ditto all as perabove item but 110 mm dia. |
| 27 | S&F in repairsLDPEpipe 50mm dia pressure rating 6kgf/cm2 as in waste pipe to wash hand Basin/Kitchen sink /urinal all as specified as in repairs. |
| 28 | S&F in repairs PVC (SWR) bends 110mm bore any radius etc complete all as specified and directed by Engr-in -charge. |
| 29 | S&F Stack clamps 110 mm pipe out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed by Engr-in-Charge. |
| 30 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L for RCC nominal mix Type B1 1:2:4(20 mm graded aggregate) as in chajjas complete all as specified and directed by Engr-in-Charge. |
| 32 | Formwork to chullah hoods, cha jjas, troughs and similar items in cluding edges for rough finish of concrete surface. |
| 33 | S&F TMT bars 10 mm dia and over cut to length bent to shape required incl cranking bending for hoping for columns hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed by Engr-in -charge.. |
| 34 | Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed by Engr-in -charge. |
| 35 | M&L Non - skid Ceramic tiles 7 to8 mm thick (square/rectangular) area of each tileexceeding 0.11 sqm but notexceeding 0.18 sqm, infloors etc. set and jointed inneat cement slurry andpointed in white or coloured cement to match fixed over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 36 | Ditto all as per above item, but as skirting or vertical surfaces with cut to size tiles fixed over and including 10mm thick backing coat in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 37 | M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tilesnot exceeding 0.36 sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white orcoloured cement to match fixed over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 38 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each coloured tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 39 | M&L glazed coloured ceramic tiles in vertical surface 350x250x6 to7mm / 450 x 350 x 6to7 mm thick set and jointed in neat cement slurry and pointed in colour cement to match and fixed over and including 10 mm thick rendering in cement mortar 1:4 etc complete all as specified |
| 40 | S & F in repairs providing & Fixing false ceilingwith semi perforated 12mm thick micro tegular edged GRG false ceiling tiles.at all height with GRG ( Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x595 mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99 % NRCO. 50 to 0.75 as per IS 8225-1987, nonombustible as per BS 476 (part-4)-1970 and light reflectance of 85 % (miinimum) to be laid in true horizontal level suspended on interlocking metal T-grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15x32 mm of length 3000mm cross-T of size 15x32mm of length 1200mm and secondary intermediate cross -T of size 15 x32 mm of length 600mm to form gris dodule of size 500 x 600 mm suspended from ceiling using galvanised mild steel items (galvanized @ 80 grams per sqm) i.e 50 mm long 8mm outer diameter M S dash fasteners 6mm dia fully threaded hanger rod upto 1000 mm length and L shape level adjuster of size 85x25x2mm galvanised iron perimeter wall angle of size 24x24x0.40 mm of length3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm centre to centre and 40mm long dry wall wood screws.The work shall be carried out as per specifications drawing and as per directions of the Engineer-in- Charge. |
| 41 | Dismantling plain or corrugated steel sheetinggauge , thickness , including Nainitalor similar pattern roof coverings complete all as specified and directed. |
| 42 | S&Fpre-painted galvalume aluminium zink coating GI based corrugated steel sheets 0.50 mm thick of an colour having tensile strength of 550 MPs as in roof covering/cladding to walls , fixed with self tapping screws complete all as specified and directed. |
| 43 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 44 | S & F 0.80mm thick Galvanised, corrugated mild steel sheeting with two corrugationsside lap, fixed with coach screws and washers, in roofs, walls etc.ith grade of zinc coating 275. complete all as specified and as directed |
| 45 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 46 | S & Froof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410- W(Gde-E-250) quality- A complete all as specified and directed |
| 47 | M & L for preparing new steel surfaces of any description over 10 cm girth and width and applying two coat of synthetic enamel paint over and including a coat of red oxide primer, complete all as specified. |
| 48 | Disconnecting existing exc 250 ltr and not exc 500 ltr tankssetting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately). |
| 49 | S & F in repair vitreous china squatting pan of Orissa pattern long pan size 580x440 mm white with integral foot rests including PVC valveless, syphonic action type, flushing cistern,low level, white, with inlet,ball valve, float and handle including brackets including lime concrete bedding all as specified . |
| 50 | S&F in repair water closet pedestal vitreous china white pattern (EWC) including white colour seat cover and connection to drain and to flush pipe & fmild steel chromium plated or aluminised hinging device etc including PVC valveless, syphonic action type, flushing cistern,low level, white, with inlet,ball valve, float and handle including brackets complete all as specified and directed by Engr-in-Charge. |
| 51 | S & F in repairs 15 mm wall mixer 3 in 1 with bend pipe including removing the existing fitting complete all as per manufacturer\"s instructions and as required at site Make : Prayag (Cat No 6480\" or equalent ). |
| 52 | S&Fin repairs wash hand basinvitreous china white flat back of size 580 X 450mm with brackets, complete all as specified and as directed by engr-in charge. |
| 53 | Demolition of Concrete of any description and in any position not otherwise specifically provided for sunken portion all as specified and as directed by Engr-in-Charge. |
| 54 | Preparation of sunken portion slab surfaces by applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces |
| 55 | M&L 15mm thick water proof plaster in CM 1:3 on roof slabs finished even & smooth using extra cement (water proofing compound will be measured & paid for separately under appropriate item here-in-after as supply only) |
| 56 | M&L for Preparation of sunken portion slab surfaces by APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified |
| 57 | M&L for applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces over water proofing membrene. |
| 58 | M&L for PCC 1:5:10 type E2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete |
| 59 | M & L 50mm thick PCC type B1 1:2:4 (20mm grade aggregate) as in Sunken floorfinishing cement concrete surface even and fair without using extra cement including WPC @ 2% by weight of cement complete all as specified and as directed.Note : WPC shall be measured and paid separately under respactive item. |
| 60 | S&F in repairs CP fancy typeABS body hand faucet with hose & hook for EWC including all necessary fitting complete all as specified. |
| 61 | S&F in repairs PVC connections 15mm size with PTMT nuts and washersfor 600mm long pipe complete all as specified and directed. |
| 62 | S&F in repairs 20 mmdia of pipegun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe etc complete all as specified & directed. |
| 63 | S&F in repairs Bib taps of 15mm dia chromium plated cast copper alloy of fancy typescrewed down for iron pipecomplete all as specified and directed.. |
| 64 | S&F in repairs bevelled edge looking mirror of size 600X450mm of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixedto wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 65 | S&F in repairPVC lowlevelflushing cisternof 10 ltr capacityfixed including syphonic action type,ball valve,floatand handle including brackets etc complete all as specified and directed. |
| 66 | S&Fin repairsPVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cementcomplete all as specified and directed. |
| 67 | Dismantling expanded metal not exc 4 kg, any thickness or mess , fixed with steel or woode fillets, if any |
| 68 | S&F Welded steel wire fabric complete to steel members n exc 4kg/sqm all as specified and as directed. |