Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-06-2024 | BOQ Corrigendum | BOQ | 18-06-2024 |
| Sl. No. | Item Description |
| 1 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm longfasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing withselected quality glass.(Note: The unit rate quoted by contractor includes cost of glass and panel and includes all other connected accessories) |
| 2 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories.) (Area not exceeding 2.00 sqm) |
| 3 | Providing and fixing factory made uPVC white colour fixed or lovoured window/ ventilator made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profileOnevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick,galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories) (Area not exceeding 1 sqm each) |
| 4 | S&F in repairs 7mm thick aluminium grills of make \"Decogrill\" model DG 104 surrounded by aluminium \"C\" channel with mesh size 75 X 75mm all as specified and directed. |
| 5 | S & FPowder coated three track Aluminium sliding window with frame not less than 1.8 mm thick excluding aluminium grill and including 4 mm thick tinted glass, beading & necessary rubber packing, locking & opening arrangement, all fitting and fixture complete all as specified and directed. |
| 6 | S&F Powder coated (Minimum thickness of Powder Coating 50 micron) Aluminium doors with frame (sliding or otherwise) with or without 12 mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations, thickness of powder coated aluminium member not less than 1.8 mm thick & 5 mm thick tinted selected glass including bedding and necessary rubber packing, 150 mm aluminium handle,150 mm tower bolt in its all fitting and fixture, mortice lock 4 lever etc complete all as specified and directed. |
| 7 | S&F door closer hydraulically regulated designation No 2, universal type, suitable for door shutter of weight between 36 to 60 Kg of aluminium (Die cast) body complete all as specified and directed. |
| 8 | S&F in repairs door closer hydraulically regulated designation No 2, universal type, suitable for door shutter of weight between 36 to 60 Kg of aluminium (Die cast) body complete all as specified and directed. |
| 9 | S&F in repairs Aluminium Mortice lock 2 lever, vertical type, size 100 mm with escutcheon plates and two keys complete all as specified and directed. |
| 10 | S&F in repairs Aluminium Mortice lock 4 lever, vertical type, size 100 mm with escutcheon plates and two keys complete all as specified and directed. |
| 11 | S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed. |
| 12 | S&F Powder coated Aluminium fixed type/ louvered Ventilator with frame not less than 1.8 mm thick & including 4 mm thick tinted glass including beading & necessary rubber packing, locking & opening arrangement if required, all fitting and fixture complete all as specified and directed. |
| 13 | M&L for cutting and removing wild bushes/ vegetation, etc at bldgs above the 2m height from GL and depositing surplus spoil/rubbish exc 100M but n.exc 500 M complete all as specified and directed. |
| 14 | Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 15 | Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 16 | Taking down shutter of any description area exceeding 1 sqm but n exc 2 sqm each and removing to store complete all as specified and directed. |
| 17 | Taking down shutter of any description area not exceeding 1 sqm each and removing to store complete all as specified and directed. |
| 18 | M&L Second class hard woodplain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 19 | M&L Second class hard wood 35 mm thick Plain, framed, panelled shutters(any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed. |
| 20 | M&L Second class hard wood 35 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed. |
| 21 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet re-inforced with MS square tube in opening as per specification and shown on drg SSR Part-II 2010. |
| 22 | S&F, factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain cover PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rails lock rail and bottom rail on either side & as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement , as per specification and shown on drawing in SSR Part-II (2010). |
| 23 | S&F Flush shutters 35 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sidescomplete all as specified and directed. |
| 24 | M&L Second class hard wood 30 mm thick factory made glazed and skeleton shutters, open rebated and prepared to receive glass , gauze etc with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) complete all as specified and directed. |
| 25 | M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 26 | Taking down shutter of any description not exceeding 1 sqm each leaf and refixing, in same opening after easing and adjusting building hard ware etc complete all as specified and directed |
| 27 | Taking down shutter of any description exceeding 1 sqmbut not exiding 2 Sqmeach leaf and refixing, in same opening after easing and adjusting building hard ware etc complete all as specified and directed |
| 28 | S&F mild steel flat iron as in bands straps, supports or stays for rainwater, ventilating pipes including bolt if required, hooks (stay) heavy for large gates,hook and pintle hinges,large hasps and staples, brackets for WHB, hold fasts, wall ties, hooks for hanging fans ,cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 29 | M&L for Cutting holes in brick walls exc half brick but not exc one brick built in cement mortor or cement lime mortor and stone walls built in lime mortor for inserting hold fasts and makinggood dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as requiredcomplete all as specified and directed. |
| 30 | S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed. |
| 31 | S&F 150 mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed |
| 32 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed |
| 33 | S&F 75 mmButt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed |
| 34 | S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed |
| 35 | S&F in repair 150 mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed |
| 36 | S&F in repair 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed. |
| 37 | S&F in repair 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed |
| 38 | S&F in repair 75 mmButt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed. |
| 39 | S&Fin repair 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
| 40 | S&F in repairfloor door stopper of aluminium alloy body and tongue, anodised, over all length of cover plate 140 mm with hard drawn steel spring fixed in door etc complete all as specified and directed. |
| 41 | S&F 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 42 | S&F in repairs 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 43 | M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 250 ltr n.exc 500 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and usingbleaching powder @ 0.25 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning,etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 44 | M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 500 ltr n.exc 1000 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using with bleaching powder @ 0.50 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning,etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 45 | S&F in repairs ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. |
| 46 | S&F in repairs ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed. |
| 47 | S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed |
| 48 | S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed |
| 49 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs /blankets, any thickness, including cover fillets complete all as specified and directed. |
| 50 | S&F 12 mm thick plain Gypsum Board False Ceiling with GI frame including all necessary drilling cutting to fix electric items complete all as specified and directed with following:- (a) GI Grid channel 30x25x20 mm of 24 gauge fixed with rawl plug and screw 450 mm centre to centre alongwith perimeter walls.(b) GI channel made to shape 50x40x40 mm of 24 gauge placed @ 600 mm centre to centre from perimeter at wall except long wall (in one span). (c) GI intermediate runners of size 45x10x10 mm of 24 gauge fixed @ 1200 mm centre to centre leaving frame of one side walls (in other span).(d) GI sheet 25 mm wide and 20 mm gauge suspended fixed with steel fastner to roof ceiling and 1200 mm centre to centre including pluging of RCC Slab. (e) 12 mm thick gypsum board filling joints with POP and finishing complete with two coat of plastic emulsion paint over one coat of primer on ceiling. |
| 51 | Hacking out old broken glass (any thickness, size quality or description) form wooden frames or stone, concrete or brick surrounds glazed with oil putty or fixed with beads complete all as specified and directed. |
| 52 | S&F 3 mm thick sheet glass ordinary quality and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 53 | S&F 3 mm thick figured glass pin headed type and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 54 | S&F in repairs aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed. |
| 55 | S&F in repairs door seal with aluminium beading and 50 mm wide rubber sealcomplete fixed to aluminium/ Wooden doors complete all as specified and directed. |
| 56 | S&F in repairs 18/19 mm thick high density PVC/ WPC solid fibre board with prelaminated PVC sheet as Kitchen cupboard and frame including taking down the old cupboard shutters and removing to store complete all as specified and directed. |
| 57 | S&F continuous (piano) hinges of width of flaps (when open) 30 mm, mild steel, bright finish or electrogalvanised complete all as specified and directed. |
| 58 | S & F magnetic catcher catcher with nut and screw of mild steel bright finish all as specified and directed. |
| 59 | S & F40 mm dia cupboard knobs fixed with nuts screw and washer of mild steel bright finish complete all as specified and directed. |
| 60 | S & Fin repair40 mm dia cupboard knobs fixed with nuts screw and washer of mild steel bright finish complete all as specified and directed. |
| 61 | S & F in repair hasp and stapple safety type aluminium anodised 75 mm long with mild steel hinge pin including bolt to hinge plate fixed with screw complete all as specified and directed. |
| 62 | S & F in repair Toilet Paper Holder with Flapcomplete all as specified and directed. |
| 63 | S & F in repair 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6 mmthickAC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 64 | S&F in repairsingle door PVC cabinet mirror of size 350 mm x 450 mm with internal shelves all as specified and directed. |
| 65 | S&F in repairsliding door PVC cabinet mirror of size 600 mm x 450 mm with internal shelves all as specified and directed. |
| 66 | S & F in repair sheetGlass Shelf assembly consisting of 5.5 mm glass sheet shelf 12 cm wide with cromium plated bracket guard and railing 60 cm long complete all as specified and directed.. |
| 67 | Taking up or down steel tubing and connections including cleaning if refixingrequired for 15 mm bore of pipe complete all as specified and directed. |
| 68 | Taking up or down steel tubing and connections including cleaning if refixingrequired for 20 mm bore of pipe complete all as specified and directed. |
| 69 | S&F GI tubes medium grade (ISI marked)with all fittingsfixed complete to walls, ceilings or laid in floors of 15 mm bore of pipe complete all as specified and directed. |
| 70 | S&F GI tubes medium grade (ISI marked)with all fittings fixed complete to walls, ceilings or laid in floors of 20 mm bore of pipe complete all as specified and directed. |
| 71 | S & F 15 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified |
| 72 | S & F 20 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified |
| 73 | Making connection of PPR distrubtion bracnch with PPR main of following outer dia of pipe 16 to 40mm size by providing and fixing tee including cutting and making fusion joint etc |
| 74 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed. |
| 75 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed. |
| 76 | S&F in repair Bib taps fancy type chromium plated 15 mm dia, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 77 | Taking down bib tap /wash basin tap/pillar tap/stop cock/mixture tap and refixing the same after repair and replacement of washer only for 15 mm bore size without replacing spindles complete all as specified and directed. |
| 78 | Taking down bib tap /wash basin tap/pillar tap/stop cock/mixture tap and refixing the same after repair and replacement ofspindles for 15 mm bore size complete all as specified and directed. |
| 79 | S & F in repair Brass chromium plated wall mixer non-telephonic shower arrangement with connecting legs & wall flanges for 15 mm bore of pipe all as specified and directed. |
| 80 | S & F in repair Brass chromium platedhole bidet mixer (Basin mixer) with pop-up waste system with 300 mm long braided hoses complete all as specified and directed. |
| 81 | S & F in repair Brass chromium plated Sink mixer with raised J shaped swinging spout (Wall mounted model) with connecting legs & Wall flangescomplete all as specified and directed. |
| 82 | S&F in repair Chromium plated fancy type Stop valves 15 mm, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 83 | S&F in repair, 15 mm bore stop cock, cast copper alloy with long shank and cup (concealed type) fancy type chromium plated screwed down high pressure with crutch & butterfly handle screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 84 | S&F in repair pillar tap cast copper alloy with capstan head chromium plated crewed down high pressure with or without lettered hot or cold with long screwed sharks and ply nuts 15 mm dia complete all as specified and directed. |
| 85 | S & F in repair bottle trap chromium plated for WHB as per approved quality all as per specified and directed. |
| 86 | S&F in repairPVC waste pipe for WHB etc all as specified and directed. |
| 87 | S&F in repairs 32 mm bore dia waste coupling of(min weight 32 mm-45 gm of PTMT) (half or full threaded) etc complete all as specified and directed |
| 88 | S&F in repair CP grating 100 mm dia with waste hole (minimum weight 40 gm) complete all as specified and directed |
| 89 | S & F in repair CP Jet spray for 15 mm bore all as specified and directed. |
| 90 | S & F in repairs Hand shower (Health faucet) with 1 mtr long Easy flex tube in crome finish & wall hook Complete all as specified and directed. |
| 91 | M&L in repairs for vitreous china wash basin, white,flat back, size 550 x 400 mmincluding supply & fixing of brass chromium plated coupling 32 mm etc complete all as specified and directed. |
| 92 | M&L in repairs vitreous china squatting pan , ‘Orissa’ Pattern, size 580 X 440 mm white, with integral foot rests etc. complete all as specified and directed. |
| 93 | M&L in repair Wash down water closet vitreous china white pedestal pattern with \"P\" or \"S\" trap including connecting to outgoing drain pipe & to flushing pipe excluding flushing cistern and flush pipe complete all as specified and directed. |
| 94 | S&F in repairs plastic water closet seat cover, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 95 | S & F in repair Kitchen sink made of stainless steel 1 mm thick with plug washer and waste pipe incl bedding fixing cantilever brackets and connetction union to pipe overall size 915 X 460mm bowl size 405X 355 mm complete all as specified and directed |
| 96 | S&F in repairs, PVC valveless syphonic action type low levelflushing cistern, 10 ltrs capacity with inlet, ball valve, float and handle including bracket complete all as specified and directed |
| 97 | S & F in repair internal fitting for low level flushing cistern (Syphon) complete all as specified and directed. |
| 98 | S&F in repairs flush pipe 32 mm dia of polyethylene of low or high density or PVC, for low level cisterncomplete all as specified and directed. |
| 99 | S & F in repair 125 mm dia chromium plated shower rose ofwith or without swivel joint incl fixing to steel pipe complete all as specified and directed. |
| 100 | S&F in repair PVC connection 15 mm bore, 450 mm long complete with both ends unions complete all as specified and directed. |
| 101 | S&F in repairs CP anodised tubular tower rail, 20 mm dia, D type, 60 cm long between flanges etc. |
| 102 | S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe of 20 mmbore dia of pipe complete all as specified and directed. |
| 103 | S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends (ISI marked) for iron pipe of 25 mmbore dia of pipe complete all as specified and directed. |
| 104 | S&F in repair 20 mm PP-R Gate valves (brass insert) as per requirement of the site complete to walls, ceilings or in floors complete all as specified |
| 105 | S&F in repair 25 mm PP-R Gate valves (brass insert) as per requirement of the site complete to walls, ceilings or in floors complete all as specified |
| 106 | S & F in repair Soap dish any type fixed to plug with chromoium plated brass screw complete all as specified and directed. |
| 107 | S & F in repair Corner glass shelfwith brackets complete all as specified and directed. |
| 108 | S & F in repairs Magic Eyes for door eye viewers brass body complete all as specified and directed. |
| 109 | S & Frepair Over head Shower 150 mm round/Square shape single flow (ABS body chrome plated with gray face plate ) with rubit cleaning system complete all as specified and directed. |
| 110 | S & F in repair chromium plated towel ring with bracket complete all as specified and directed. |
| 111 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified |
| 112 | Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified. |
| 113 | Removing excavated material to a distance not exc 50M anddepositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified |
| 114 | Supply and laying double wall corrugated (DWC) HDPE pipe 63 mm outer dia for protection of UG cable as per IS: 16205 (part 24) of 2017 complete all as specified. |
| 115 | Supply and laying double wall corrugated (DWC) HDPE pipe 90 mm outer dia for protection of UG cable as per IS: 16205 (part 24) of 2017 complete all as specified |
| 116 | M&L PCC 1:4:8 type D 2 using 40 mm graded stone aggregate for fillingof pole & stay complete all as directed |
| 117 | M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for fillingof pole & stay complete all as directed |
| 118 | M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for copining of pole complete all as directed |
| 119 | M & Lfortubelightgrade galvanisedwithallfittingslaidalong the pole/intrenches / underroadorfloorof50mmbore including removing the rusted old one completeallasspecifiedanddirected. |
| 120 | M & Lfortubelightgrade galvanisedwithallfittingslaidalong the pole/intrenches / underroadorfloorof80mmbore including removing the rusted old one completeallasspecifiedanddirected. |
| 121 | M & Lfortubelightgrade galvanisedwithallfittingslaidalong the pole/intrenches / underroadorfloorof100mmbore including removing the rusted old one completeallasspecifiedanddirected. |
| 122 | Taking out old unserviceable PCC/steel tubularpole 9 mtrs long and supply and fixing steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
| 123 | Taing out old usserviceable PCC pole of any size and supply and fixing in repairs Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l02mm x 279mm at bottom, class 10 and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of weather proof paint complete, all as specified and directed. |
| 124 | S & F in replacement of Cross arm, bracings, supports , clamps and back plate fabricated from structural steel section, including nut , bolts , washers, welding , bendings cold or hot, drilling hole for both in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat of paint incl taking down the old unserviceable cross arms complete all as directed. |
| 125 | M & L stay assembly complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete only measured separately) using diameter of stay rod 16 mm and MS stay plate 230mm x 230mm including taking down complete all as directed. |
| 126 | Supply and fix in replacement of loop type insulator vitreous white,brown or green insulator small size,with over all dimensions 65 x 90 mm,clearance of hole 16 mm complete all as directed. |
| 127 | Taking out old UNSV and Supply, laying, jointing and testing ofXLPE insulated, armoured, heavy duty LT under ground cable of size10 Sqmm 2 Core 1100 Volts gradewith aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed :- |
| 128 | All as per item no. 127 but of size 16 Sqmm 2 Core. |
| 129 | All as per item no. 127 but of size16 Sqmm 4 Core. |
| 130 | All as per item no. 127 but of size 25 Sqmm 3.5 Core. |
| 131 | All as per item no. 127 but of size35 Sqmm 3.5 Core |
| 132 | All as per item no. 127 but of size50 Sqmm 3.5 Core |
| 133 | All as per item no. 127 but of size70 Sqmm 3.5 Core |
| 134 | All as per item no. 127 but of size 95 Sqmm 3.5 Core |
| 135 | All as per item no. 127 but of size 120 Sqmm 3.5 Core |
| 136 | All as per item no. 127 but of size 150 Sqmm 3.5 Core |
| 137 | All as per item no. 127 but of size185 Sqmm 3.5 Core |
| 138 | M/L for replacement of Earthing complete with GI earthplate 60x60cmx6mm thick electrode and using galvanised iron strip 32 x 6 mm as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified and as directed by Engr-in-charge. |
| 139 | Supply and fixing of moulded case circuit breaker Four pole 63/100 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 140 | Supply and fixing of moulded case circuit breaker Four pole 125 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 141 | Supply and fixing of moulded case circuit breaker Four pole 160 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 142 | Supply and fixing of moulded case circuit breaker Four pole 200 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 143 | Supply and fixing of moulded case circuit breaker Four pole 250 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 144 | Supply and fixing of moulded case circuit breaker Four pole 320 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 145 | Supply and fixing of moulded case circuit breaker Four pole 400 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 146 | Supply and fixing of digital voltmeter 0 to 500 volts 96 x96mm flush type in LT Panels incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 147 | Supply and fixing of digital ammeter range as per existing 96 x96mm flush type in LT panels incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 148 | Supply and fixing of LT current transformer ratio from 200/5 Ampsor 100/5 or 400/5 in LT panels incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 149 | Supply and fixingselector switch of voltmeter/ammeter in LT panel boards incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 150 | Supply and fixing indicator assembly (RYB) LED type in LT panel boards incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 151 | M&L for painting steel tubular/RS joist pole 9 mtrs long alongwith bends with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
| 152 | M&L for painting PCCpole 9 mtrs long alongwith bends with two coats of weather proof paint and two coats of black bituminous paint over a coat and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
| 153 | M&L for painting to LT panels of any size with two coats of sky blue paint over a coat of red oxide primer outerside and two coats of off white paint over a coat of red oxide primer internally complete all as specified and directed by Engr- in-Charge. Note: 1. Before painting the contractor will ask for a shut down of the recpective feeder from the JE.2. While painting of the panels protection of MCCB\"s and MCB\"s to be taken care of by the contractor.Any damage occured during the painting will be bear by the contractor. |
| 154 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 2 core XLPE armoured aluminium conductor cable of size 10-16 sqmm complete |
| 155 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16-50 sqmm complete |
| 156 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm complete |
| 157 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 150 to 185 sqmm complete |
| 158 | Boring of holes horizontally for laying of 80mmdia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed. |
| 159 | Supply and fixing Aluminium tube terminal/ lugs of undermentioned of size 10 to 25 Sqmm complete all as specified and directed. |
| 160 | All as per item no. 159 of size35 to 50 Sqmm |
| 161 | All as per item no. 159 of size 70 to 120 Sqmm |
| 162 | All as per item no. 159 of size150 to 185 Sqmm |
| 163 | All as per item no. 159 of size240 to 300 Sqmm |
| 164 | supply only PVC Electricalinsulation self adhesive tape 1.8cmx7mx0.125mmfor Red, Yellow, Blue & Green all as specified and directed |
| 165 | Supply, fabricate, erect, test and commission in replacement outdoor LT MS Feeder pillar box totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC Supply, factory made standard design as per electrical requirements to suit power distr sys , enclosure fabricated out of 3.00 mm thick MS sheet, excavation and earth work, PCC foundation etc,with hinged doors and lcoking arrangemetn , air vents, tappered roof, incoming and outgoing cable connections from bottom with compressed cable gland etcas required with and including the following, supplied fitted and connected internally complete04 Nos aluminiumbus bar of size 50 x 10 mm with PVC coloured heat srinkable type sleeves continous phase rating 400 Amps rating mounted on non cracting resin type insulators complete all as specified |
| 166 | S & F in replacement of old UNSV. Cable loop box with SMC Junction box shock and rust proof , rot/termite resistance, tamper proof, with necessary pole mounting arrangements FR type ( (270mm x 225mm x 135mm) with in-built /housed terminal for 04 pole wire termination and 6AMCB din-rail mounted , hinged door with locking arrangements incl necessary Galvanised iron clamps, bolts/nuts suitable to hold/accommodate to the exisitng pole(any type)/ bldg etc by removing the exisiting electrical connections and reconnecting back the same cable complete all as specified & directed Make: Sintex/Hensel (Note : any glands/lugs/lock-pads reqd for the same is within the the rates quoted) |
| 167 | S&F in repair/ repalcement of on load change over switches 4 pole 160A in open execution, 415 volts, 50 Hz complete all as specified and directed. |
| 168 | S&F in repair/ repalcement of on load change over switches 4 pole 200A in open execution, 415 volts, 50 Hz complete all as specified and directed. |
| 169 | S&F in repair/ repalcement of on load change over switches 4 pole 250Aamp in open execution, 415 volts, 50 Hz complete all as specified and directed. |
| 170 | S&F in repair/ repalcement of on load change over switches 4 pole 400Amp in open execution, 415 volts, 50 Hz complete all as specified and directed. |
| 171 | S&F in repairs Aluminium strip 32x6 mmwith saddles and fixing screws etc. for roofconductors and down conductors above ground. |
| 172 | S&F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specifed and directed. |
| 173 | M&L for in repairs Aluminium conductor, steel reinforced, to stringe against the old unsv overhead conductor of suitable size with keep proper sag as applicable complete all as specified and directed. |
| 174 | M & L for earth continuity conductor using GI strip 32 x 6 mm galvanised iron strip complete all as directed incl taking down the old unserviceable complete. |
| 175 | Taking up or down XLPE cable with connections for detecting the fault and after repair relaying the same complete, all as specified and directed. Note :- Measurement for excavation, returning, removing, sand and brick will be measured and paid at appropriate items of this sechdule. |
| 176 | S&F in repairs HRFR PVC insulated industrial cabled single core copper conductor, 1100 volts conforming to IS 694 of size 16 Sqmm complete all as specified and directed |
| 177 | S&F in repairs HRFR PVC insulated industrial cabled single core copper conductor, 1100 volts conforming to IS 694 of size 16 Sqmm complete all as specified and directed |
| 178 | S&F in repairs aluminium busbar of suitable size as per exisiting on ground and removing the old burnt one from LT panel with complete connection of existing cables all as specified and directed. |
| 179 | M&L for attending day to day breakdown complaints of any nature in low tension line after receiving the complaint from complaint cell/ JE concerned and rectifying the same as soon as possible complete all as specified and directed. |
| 180 | Supply and fixing in repairs SP 5-32 amp rating 240V, 10KA \"C\" curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 181 | Supply and fixing in repairs SPN 32-40 amp rating 240V, 10KA \"C\" curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 182 | Supply and fixing in repairs TPN 40-100 rating 415, 10KA \"C\" curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 183 | Supply, laying, jointing and testing ofXLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith copper conductor conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for 35 Sqmm 3.5 core complete, all as specified and directed |
| 184 | Supply and fixing FRP fencing made up with using FRP rod 12 mm dia, channel size 50x24x4 mm box section 50x25 mm I Section 38x15x3 mm and square box section 50x50mm in post embedded in plain cement concrete (1:4:8) type D2 using 20 mm graded stone aggrerate (45x45x45cm) including necessary excavation and earthwork at 1.25 m C/C with height of fencing 2 m from GL including entracne gate of size 1mx2m of same material MS aldrop bolt 300mm long , 150 mm size pressed steel handles and 2 Nos tower bolts MS hinges as required etc complete all as specified and directed Note :- Verticle posts and rail section shall be manufactured of fibre glass reinforcement min 45% and formulation of polystrbased thermoset resigns. |
| 185 | Supply and fixing in repairs modular switch 1 way,16Amps,1module,240V, ISI Marked and suitable for existing type as per site requirement andincluding removing old usnv items complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail