| 1 | Attending of day to day complaints 24 x 7 Hours for summer and cooling appliances system all type nature of complaints for AC\"s, Refrigerator / Water cooler / Desert cooler and Geyser etc and any type / nature of complaints at OTM, KLP and MD Accn and all as directed by MES representative of Miran Sahib.Notes: - (i) Contractor / his representative shall attend MES service centre daily routine complaints at 0900 hours to note down the complaints from concerned JE and shall submit complaince report at 1700 hours for the complaints given in the morning.(ii) Labour rates deemed to be included in the quoted rate in respect of relevant schedule of items.(iii) All type of T&P as required at site for the work shall be arranged by the contractor under his own arrangements, cost deemed to be included in quoted rates.(iv) A recovery @ Rs. 650/- per day per complaint shall be recovered from the contractor if complaint given to the contractor remains unattended / not rectified at the end of the day.(v) Contractor shall employee minimum of one Refrigerator Mechanic and one helper or relevant technician (for complaints) having adequate experience in the said field.(vI) Any type of complaints to be attended and record in complaint slip. |
| 2 | Material and labour for repair / maint to desert coolers complete with and including cleaning, scrapping / rubbing old rusted surface, filling cavities and painting with two coats of high quality aluminium paint over a coat of red oxide primer externaly and black paint internally with synthetic enamel paints complete with replacement of necessary nut, bolts, rubber pads for fan motors and writing MES No / unit name all as specified and directed by the Engineer-in-Charge. |
| 3 | Supply and fixing in replacement of desert cooler fan motor 90 watt, 1400 RPM, 230 volt, 50 Hz single phase conforming to ISI complete with fan blade and capacitor of suitable size complete all as specified and as directed. |
| 4 | Supply and fixing in replacement of desert cooler submersible pumping set single phase 230 volt, 50 Hz of 0.25 to 1.0 HP conforming to ISI complete with lead all as specified and as directed. |
| 5 | Supply and fixing in replacement of PVC accessories of desert cooler i.e. PVC pipe 20 mm dia heavy duty 2 metre approximate, PVC distributor 4 way with nut, bolts, PVC elbow - 03 No\"s, mild steel clamps etc complete all as specified and directed. |
| 6 | Supply and fixing in replacement of desert cooler fan motor blade of existing size made out from mild steel having duty complete with key bolt complete all as specified and as directed. |
| 7 | Supply and fixing in replacement of desert cooler front ventilator cover of mild steel of suitable size complete with selector switch, switch point 5 Amp, indicator lamp and electric wiring, fixing nut, bolts of suitable size all as specified and directed. |
| 8 | Supply and fixing in replacement of desert cooler side opening cover made out from heavy duty mild steel sheet and matching with the existing desert cooler body size complete with Khas Khas pads set of three pieces all as specified and directed. |
| 9 | Supply and fixing in replacement of desert cooler unserviceable / leakage body made out from heavy duty mild steel sheet bend to shape company manufacturer, complete with internal PVC accessories i.e. PVC elbow - 03 No\"s, PVC distributor 4 way - 01 No, PVC distrbution pipe - 2 metre approximate, Black painted internally, Aluminium painted externally complete with provision of necessary arrangement for fixing front cover and fan motor all as specified and directed. |
| 10 | Supply and fixing in replacement cable PVC insulated and sheathed of size 1.5 Sqmm 3 core FRLS 230 volt, 50 Hz conforming to ISI all as specified and directed. |
| 11 | Supply and fixing in replacement cable PVC insulated and sheathed of size 2.5 Sqmm 3 core FRLS 230 volt, 50 Hz conforming to ISI all as specified and directed. |
| 12 | Supply and fixing in replacement cable PVC insulated and sheathed of size 4.0 Sqmm 3 core FRLS 230 volt, 50 Hz conforming to ISI all as specified and directed. |
| 13 | Supply and fixing in replacement of plug top 3 pin, 5 Amp, 230 volt, 50 Hz all as specified and directed. |
| 14 | Supply and fixing in replacement of desert cooler ON / OFF rotary selector switch of suitable size for speed controller all as specified and as directed. |
| 15 | Supply and fixing in replacement of PVC accessories of capacitor 2.5 MFD for desert cooler fan motor, 230 volt, 50 Hz complete all as specified and as directed. |
| 16 | Supply and fixing in replacement of unserviceable Khas Khas / Glass wool for desert cooler set of three pieces complete all as specified and as directed. |
| 17 | Repair / Maint / Servicing to refrigerator / deep freezer / water coolers / AC\"s of any capacity and model by replacing capillary tubing, gas chargings, rectification of leakage in capillary tubing / Chiller plant / water tanks, condensing coils, repair to wiring, flushing / cleaning condensing / cooling coils / internal / external unit of split AC, greasing to blower motors, replacement of spare parts, fan belts and make refrigerator / deep freezer / water coolers / AC\"s in serviceable condition all as specified and directed by Engineer-in-Charge.Note: - Spare / Gas charging shall be paid separately. |
| 18 | Charges for fixing in replacement of unserviceable sealed seamless welding compressor unit company manufacturer of any capacity for AC\"s complete with initial filling / charging of refrigerant gas to meet the requirement complete with vibration rubber pads four no\"s each nut, bolts etc and testing on full load all as specified and directed by Engineer-in-Charge.Notes: - (i) Spare parts shall be measured and pad separately under respective items.(ii) Contractor shall be responsible for all replacement of failed compressor and shall be accompanied by certificate from the original compressor to the effect that said compressor has been repaired at their authorised service center. Further, a warrenty of 12 months shall be provided on such replacement in writing. |
| 19 | Supply only sealed compressor unit seamless welding company manufacturer with filling of refrigerant gas conforming to ISI as under: - |
| 20 | For refrigerator 165/286 litre capacity. |
| 21 | For refrigerator 290/320 litre capacity. |
| 22 | For Deep Freezer 100/200 litre capacity. |
| 23 | For Deep Freezer 300/400 litre capacity. |
| 24 | For Water Cooler 40/80 litre capacity. |
| 25 | For Water Cooler 60/120 litre capacity. |
| 26 | Split / Window AC 1.5 Ton capacity. |
| 27 | Split / Window AC 2.0 Ton capacity. |
| 28 | Supply and fixing in replacement of unserviceable / burnt condensing fan motor 1/35 HP single phase 230 volt 50 Hz complete with blade, fan belts for water cooler of capacity 40/80 litre and 60/120 litre complete all as specified and as directed. |
| 29 | Supply only condensing fan motor 1/5 HP 1440 RPM single phase 230 Volt 50 Hz with double blade and shaft end with fan belts for window AC / Split AC conforming to ISI of capacity 1.5 / 2.0 ton complete with vibration parts etc. all as specified and as directed. |
| 30 | Supply and charging refrigerant 134a/R-22 in sealed compressor unit of refrigerator / deep freezer / water coolers / AC\"s of any type and capacity after flushing the complete system with carbon tetrachloride (CTC) and vacuumise the complete system with vacuum pump and testing on full load including replacement of filter, strainer all as specified and directed. |
| 31 | Supply and fixing in replacement of following spare parts for refrigerator / deep freezer / water coolers / AC\"s of any capacity: - |
| 32 | Starting relay |
| 33 | Overload protector |
| 34 | Thermostat switch |
| 35 | Defroz switch |
| 36 | Supply and fixing in replacement of following unserviceable spare parts of water cooler of any capacity: - |
| 37 | Starting capacitor 45 mfd |
| 38 | Running capacitor 60/120 mfd |
| 39 | Float valve PVC 15 mm dia with ball |
| 40 | Push cock chromium plated 15 mm with nipple 6\"\" long |
| 41 | Drain/Wash out flexible down pipe 40 mm dia |
| 42 | Water tank door gasket |
| 43 | Water drain tray of suitable size |
| 44 | Supply and fixing in replacement of unserviceable following spare parts of window / split AC unit of capacity 1.5 to 2.0 ton: - |
| 45 | Starting capacitor 36/40 mfd |
| 46 | Running capacitor 100/120 mfd |
| 47 | PCB of Split AC |
| 48 | Front Grill cover for window AC 1.5 Ton |
| 49 | On/Off selector switch for window AC |
| 50 | Condensing fan motor double shaft |
| 51 | Material and labour for repair to Automatic voltage stabilizer with rewinding of coils and replacement of unserviceable / burnt spare parts relay, volt / amp meter On / Off selector switch, Auto cut timer switch indicators, repair to PCB, socket outlet 6 pin 3 in 1, 15 Amp, plug top 5/15 Amp of capacity 0.5 to 5 KVA complete including testing complete all as specified and as directed.Note: - Winding will be paid separately. |
| 52 | Supply and fixing in replacement of PVC flexible braided pipe of 20 mm dia for split AC water drain out all as specified and directed. |
| 53 | Supply and fixing in replacement of outer split AC condensing unit complete for split AC 1.5 ton all as specified and directed. |
| 54 | Supply and fixing in replacement of inner unit of split AC complete with filters, blower motor etc for split AC 1.5 ton complete with all accessories all as specified and directed. |
| 55 | Supply and fixing in replacement of copper capillary tubing 5/8\"\" for AC connection / repair complete all as specified and directed. |
| 56 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular 10 Sqmm complete all as specified and as directed. |
| 57 | Supply and fixing in replacement of condensing unit of Refrigerator / Deep Freezer / Water Cooler of any capacity complete with cutting and brazing work all as specified and directed. |
| 58 | Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 5 KVA complete all as specified and as directed. |
| 59 | Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 3 KVA complete all as specified and as directed. |
| 60 | Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 2 KVA complete all as specified and as directed. |
| 61 | Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 1 KVA complete all as specified and as directed. |
| 62 | Labour for repair / servicing of ceiling fan of any capacity complete with strip opening the ceiling fan for repair / washing / varnishing and removing of old lubricating substance from bearing / bush using Kerosine oil, carrying out fresh lubrication using grease and to make the ceiling fan noise free for smooth functioning, including replacement of worn out / unserviceable minor spare parts split pin, fan body bolts, spring washer, fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 m long, assembling the repaired ceiling fan and testing to the entire satisfaction of Engineer-in-Charge and depositing in MES store yard complete all as specified and as directed. Note: - Replacement of spares flexible wire etc / rewinding of ceiling fan shall be measured and paid separately under respective item for material and labour cost. |
| 63 | Description all as per Ser item No. 37.00 here-in-before but for exhaust fan of any type mm sweep complete all as specified and as directed. |
| 64 | Description all as per Ser item No. 37.00 here-in-before but for wall mounting fan of any size / type complete all as specified and as directed. |
| 65 | Rewinding of ceiling fan, of any make / type and size (1200 / 1400 mm sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufacturer\"s specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stator / rotor, connection and testing complete all as specified and as directed. |
| 66 | Description all as per Ser item No. 40.00 here-in-before but for exhaust fan of any make / type and size complete all as specified and as directed. |
| 67 | Description all as per Ser item No. 40.00 here-in-before but for wall mounting fan of any make / type and size complete all as specified and as directed. |
| 68 | Labour for remetalling of worn out shaft of fan, cutting, brazing, machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the entire satisfaction of Engineer-in-Charge to ensure smooth and noise free operation complete all as specified and as directed. Note: - Bearing shall be measured and paid separately. |
| 69 | Supply and fixing ball bearing of any size and type, suitable for any type / make / size of ceiling fan complete all as specified and as directed. |
| 70 | Description all as per Ser item No. 44.00 here-in-before but for exhaust fan of any type / make and size complete all as specified and as directed. |
| 71 | Description all as per Ser item No. 44.00 here-in-before but for wall mounted fan of any type / make and size complete all as specified and as directed. |
| 72 | Supply, fixing in replacement of capacitor 230 Volt AC, 50 Hz, conforming to IS-1709 and rated capacity 2.5 MFD for ceiling fan, exhaust fan and wall mounted fan complete all as specified and as directed. |
| 73 | Description all as per Ser item No. 47.00 here-in-before but of rated capacity 4.0 MFD for exhaust fan complete all as specified and as directed. |
| 74 | Supply and connection of PVC insulated, unsheathed multistranded, three core twisted copper flexible cable of size 1.5 Sqmm as required complete all as specified and as directed. |
| 75 | Supply and fixing only bush of suitable size for exhaust fan of any type / size as per existing type complete all as specified and as directed. |
| 76 | Description all as per Ser item No. 50.00 here-in-before but suitable for wall mounted fan of any type / size as per existing type complete all as specified and as directed. |
| 77 | Supply and fixing of PVC connector 4 way 6 Amps with connection screws, nuts complete all as specified and as directed. |
| 78 | Supply and fixing of PVC clamps with fixing screws for holding capacitor of any type and size complete all as specified and as directed. |
| 79 | Supply and fixing of galvanised iron / mild steel anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole complete all as specified and as directed. |
| 80 | Supply and fixing in replacement mild steel clamp for down rod of suitable size including gromet / reel type rubber pad with bolts, nuts, split pin and washers suitable for housing ceiling fan complete all as specified and as directed. |
| 81 | Supply and fixing in replacement of ceiling fan down rod 12 mm dia and 30/45 cm long complete with mild steel clamp rubber reel, split pin, nut, bolts etc. complete all as specified and as directed. |
| 82 | Supply and fixing in replacement of louver shutter made of mild steel sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs frames made of mild steel flat strips of size 25mm x 3mm includidng heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall at ground / first / second floor etc complete with using fastener bolt, drilling, (spray painting) over a coat of primer for exhaust fan up to 400 mm sweep including taking down old one complete all as specified and as directed.Notes: - (i) Rates are deemed to be including charges for hiring any type of T&P, Ladder, cutter etc.(ii) Contractor shall be responsible for life cover of staff deployed for fixing lover shutter. |
| 83 | Cleaning of ceiling fan assembly of any type / size and carrying out two coats of spray painting with first quality synthetic enamelled paint of approved colour, including writing of MES number in black paint complete all as specified and as directed. |
| 84 | Description all as per Ser item No. 58.00 here-in-before but for exhaust fan upto 450 mm complete all as specified and as directed. |
| 85 | Supply and fixing in replacement of PVC canopy set of two pieces for ceiling fans of any size complete all as specified and as directed. |
| 86 | Repair to oscillation moving part of wall mounted fan including replacement of all wornout components, bearing, lubrication and assembling complete all as specified and as directed. |
| 87 | Supply and fixing ceiling fan blades set of 3 pieces suitable for 1200 / 1400 mm sweep of white / brown / ivory colors all as specified and directed. |
| 88 | Taking down and strip opening to geyser of any make and capacity 25 / 35 / 50 litres including disconnection of all water pipe connection and taking out water inlet / outlet assembly, removing glass wool, the inner tank, descaling the assembly and tank, detecting the leakage, welding / brazing the defected part, repacking the glass wool and refixing the same after making it functional including replacement of worn out nuts, bolts, washer etc complete all as specified and directed.Note: - Cost of material and labour for providing new items shall be measured under relevant items of schedule \"A\". |
| 89 | Material and labour for replacement of water inlet and outlet geyser assembly of existing make as required at site with rubber gasket suitable for geyser of 25 / 35 litres capacity electric driven water storage heater with provision of housing for thermostat assembly, heating element fixing arrangement nuts, bolts and washers etc. complete all as specified and directed. |
| 90 | Material and labour for replacement of water inlet and outlet assembly of existing make as required at site with rubber gasket suitable for geyser of 50 litres capacity electric driven water storage heater with provision of housing for thermostat assembly, heating element fixing arrangement nuts, bolts and washers etc. complete all as specified and directed. |
| 91 | Material and labour for replacement of geyser internal assembly (flanged) comprising complete with heating element and thermostat housing complete all as specified as per site requirement and suitable with the existing assembly suitable to 25 / 50 litres capacity all as directed. |
| 92 | Material and labour for replacement of thermostat capillary type switch for electric water heater storage type of capacity 25 / 50 litre, 230 volts of existing make of geyser complete all as specified and directed. |
| 93 | Material and labour for replacement of thermostat, switch electric water heater storage type of capacity 25 / 50 litre, 230 volts of existing make of geyser complete all as specified and directed. |
| 94 | Material and labour for replacement of heating element with triangular base / round base, single phase, 230 volt, capacity 2 KW of existing make complete all as specified and directed. |
| 95 | Material and labour for replacement of heating element with triangular / round base, single phase, 230 volt, capacity 1.5 KW of existing make complete all as specified and directed. |
| 96 | Material and labour for replacement of pressure release valve conforming to relevant IS 15mm bore suitable for fixing with galvanised iron pipe / tubing 15mm bore complete all as specified and directed. |
| 97 | Material and labour for replacement of heavy duty PVC connection (For Hot Water) nylon threaded 450mm large (18”) 15mm bore including brass nuts, rubber washers complete on both ends all as specified and directed. |
| 98 | Material and labour for replacement of heavy duty PVC connection (For Cold Water) nylon threaded 450mm large (18”) 15mm bore including brass nuts, rubber washers complete on both ends all as specified and directed. |
| 99 | Material and labour for replacement of indicator lamps round / rectangular type 230 volt AC suitable for geyser of any capacity including providing electric connections complete all as specified and as directed. |
| 100 | Supply and fixing in replacement unserviceable geyser with metal body water heater storage type (geyser) 25 litre capacity, conforming to ISI, single phase with working voltage 240Volts, 50 Hz complete all as specified and directed. |
| 101 | Material and labour for replacement of water storage inner tank of stainless steel heavy duty conforming to ISI 25 / 35 litres capacity geyser, with provision for fixing 15mm dia galvanized air release valve all as specified and directed. |
| 102 | Material and labour for replacement of water storage inner tank of stainless steel heavy duty conforming to ISI 50 litres capacity geyser, with provision for fixing 15mm dia galvanized air release valve all as specified and directed. |
| 103 | Supply and fixing in replacement MCB SPN 32 Amps 240 volts, rupturing capacity 10 KA, \"C\" series complete all as specified and directed. |
| 104 | Supply and fixing in replacement plug top 15 Amps 3 pins complete all as specified and directed. |
| 105 | Material and labour for painting of geyser of capacity 25 / 35 / 50 litre complete with superior quality synthetic enamel white paint by spray painting after scrapping old paint and making surface clean all as specified and directed. |
| 106 | Material and labour for replacement of non return valve 15 mm dia complete all as specified and directed. |
| 107 | Material and labour for replacement of split bottom cover (two pieces) suitable for 25 to 50 litres geysers complete with fixing arrangement etc as required at site complete all as specified and as directed. |
| 108 | Material and labour for replacement of rubber gasket heavy duty of water inlet outlet assembly suitable for 25 litres capacity geyser complete all as specified and as directed. |
| 109 | Material and labour for replacement of outer shell suitable for 25 / 35 litre geyser made out of galvanised iron sheet heavy duly conforming to ISI suitable for existing make of geyser complete factory manufactured painted all as specified and as directed. |
| 110 | Material and labour for replacement of outer shell suitable for 50 litre geyser made out of galvanised iron sheet heavy duly conforming to ISI suitable for existing make of geyser complete factory manufactured painted all as specified and as directed. |
| 111 | Supply and fixing in replacement of glass wool suitable for geysers complete all as specified and as directed. |
| 112 | Repair / maintenance / servicing to solar water heater system having capacity 100 to 500 LPD complete with descaling / cleaning to flat plate collector plate, solar heater water tanks, toughened solar glass panels, welding / breazing to solar tanks, Repair / rectification of leakage in inlet / outlet water tubing galvanised iron, checking and repair to electric system, repair of water make up tank and make the system functionable after repair / servicing and rectification of the fault complete with and including replacement of minor spare parts complete all as specified and as directed.Note: - Spare shall be measured and paid separately. |
| 113 | Supply only union medium grade 25 mm dia complete all as specified and as directed. |
| 114 | Supply only union medium grade 20 mm dia complete all as specified and as directed. |
| 115 | Supply only rubber hose pipe with mild steel clamp of suitable size complete all as specified and as directed. |
| 116 | Supply only gun metal gate / glove valve 20 mm dia complete all as specified and as directed. |
| 117 | Supply only rubber gasket of toughened glass complete all as specified and as directed. |
| 118 | Supply only painting to steel structure base frame complete all as specified and as directed. |
| 119 | Supply only float valve PVC 20 mm dia complete all as specified and as directed. |
| 120 | Material and labour for replacement of electrical heating element long threaded type, as per existing 3 KW, ISI marked, single phase suitable for solar water heater complete all as specified and directed. |
| 121 | Material and labour for replacement of thermostat, long body, ISI marked of solar water heater of capacity 100 to 500 LPD complete all as specified and directed. |
| 122 | Material and labour for replacement of solar hot water tank with thermal insulation suitable for solar water heater of capacity 100 LPD complete all as specified and directed. |
| 123 | Material and labour for replacement of solar hot water tank with thermal insulation suitable for solar water heater of capacity 500 LPD complete all as specified and directed. |
| 124 | Material and labour for replacement of toughened collector glass of size 1.5M x 1.0 metre complete all as specified and directed confirming to ISI. |
| 125 | Material and labour for fasteners 80-100 mm long for fixing of geyser of capacity upto 50 litres including grouting completed works in wall as per site requirement with the floor complete all as specified and directed. |
| 126 | Supply and fixing in replacement chromium plated CP bib cock 15 mm dia conforming to ISI complete all as specified and directed. |
| 127 | Supply and fixing in replacement gun metal glove / gate valve 15 mm dia internal threaded with iron wheel head conforming to ISI complete all as specified and directed. |
| 128 | Material and labour for replacement of hot water pipe insulation with glass wool and aluminium cladding 20mm bore including all materials as required all as specified and directed by Engineer-in-Charge. |
| 129 | Supply and fixing sheet metal enclosure for MCB distribution board SPN 240 Volts, 2 way single door without bus bar, enclosure made up of CRCA sheet IP-30 including wooden rectangular board of first quality of suitable size for mounting of distribution board box complete all as specified and directed by Engineer-in-Charge. |
| 130 | Supply and fixing in replacement for MCB SPN 32 Amps 240 Volts, \"B\" series complete all as specified and as directed. |
| 131 | Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn in but including non metallic rigid PVC concealed conduit of 25 mm dia fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed.Note: - Wiring shall be done in proper colour coding. |
| 132 | Material and labour for replacement of tubing galvanised iron \"medium grade\" with all fittings laid in floor or trenches including taking out old unserviceable pipe of size 15 mm dia complete all as specified and directed. |