| Sl. No. | Item Description |
| 1 | Taking up U/S CI water main (incl all fitting) with spigot & socket /MS pipe or any other type of pipe or lead joint incl burning out joint & recovering lead from pipe upto 150mm bore for laying/re-routing of serviceable pipe after cleaning complete all as specified and directed. |
| 2 | All as per Item No 01 Above but 200 mm dia, complete all as specified and directed. |
| 3 | S&F in replacement ofDI pipes of size 100mm bore with spigot and socket end centrifugally cast class \"K- 7\" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position, complete all as specified and directed.Note: DI fitting /lead joint / Tyton joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be reused or removed from site. |
| 4 | All as per Item No 03 Above but 150 mm dia, complete all as specified and directed. |
| 5 | S&F in replacement ofCast iron pipesof size 80mm bore with spigot and socket ends centrifugally cast. Class LA, in any length, laid in trenches/floor, complete all as specified and directed.Note: DI fitting /lead joint / Tyton joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be reused or removed from site. |
| 6 | All as per Item No 05 Above but 100 mm dia, complete all as specified and directed. |
| 7 | All as per Item No 05 Above but 150 mm dia, complete all as specified and directed. |
| 8 | All as per Item No 05 Above but 200 mm dia, complete all as specified and directed. |
| 9 | S&Fin replacement of DI/CI bend any type radius and angle tapers any type straght bend increacing decreacing or double socket etc) tee pipe single branch by juction double branch cross (all socket and spiogat collars caps and plug for the pipe socket & spiogat of the following size upto 150 mm dia complete all as specified and directed.Note: Lead /gasket for fitting shall be measured and paid separately. |
| 10 | M&L for cutting of existing CI/DI pipe line in position for rectifying leakage and reducing to required length, in position, for insertion of collars or other fittings including necessory exvation and earthwork, dewatering etc,if any involed, complete all as specified anddirected for 80mm bore of pipesNote for item no: 10, 11, 12 & 13:Insertion of fittings/ pipes pieces etc shall be measured & paid for separately. |
| 11 | All as per item No: 10 above but of 100m bore pipe, complete all as specified and directed. |
| 12 | All as per item No: 10 above but of 150m bore pipe, complete all as specified and directed. |
| 13 | All as per item No: 10 above but of 200m bore pipe, complete all as specified and directed. |
| 14 | M&L in replacement of ruber gas ket joint/ tyton jointfor CI/DI pipe of size 100 mm bore, complete all as specified and directed by Engr-in-charge. |
| 15 | M&L in replacement of ruber gas ket joint/ tyton jointfor CI/DI pipe upto size 150 mm bore, complete all as specified and directed by Engr-in-charge. |
| 16 | S&F in replacement of pig lead joint metal type for CI/ MS pipe line complete all as specified and directed by Engr-in-charge. |
| 17 | S&F in replacement of Spun yarn for CI/ MS pipe line all as specified and directed by Engr-in-charge. |
| 18 | S&F of DI/CI MJ collar suitable for 80mm Dia, ISI marked including nut, bolt, washer and gasket of suitable & size of any quantity as per site requirment, for leakage repair in CI/DI pipe, complete all as specified & directed.Note: Excavation& other CI/DI fittings will be measured & paid Saperately in respective item. |
| 19 | All as above item No: 18, but of size 100mm dia complete all as specified and directed by Engr-in-charge. |
| 20 | All as above item No: 18, but of size 150mm dia complete all as specified and directed by Engr-in-charge. |
| 21 | All as above item No: 18, but of size 200mm dia complete all as specified and directed by Engr-in-charge. |
| 22 | S&F of CI/DI leakage clampssuitable for 80/100mm Dia, ISI marked including nut, bolt, washer and gasket of suitable & size of any quantity as per site requirment, for leakage repair in CI/DI pipe, complete all as specified and directed by Engr-in-charge.Note: Excavation & other CI/DI fittings will be measured & paid Saperately in respective item. |
| 23 | All as above item No:22, but of size 150mm dia complete all as specified and directed by Engr-in-charge. |
| 24 | All as above item No:22, but of size 200mm dia complete all as specified and directed by Engr-in-charge. |
| 25 | M&L for welding of MS flange on MS pipe upto 200mm dia including making grooves/bore for nut bolts in flange complete all as specified and directed by Engr-in-charge. |
| 26 | Taking out existing U/S NRV of size 50-200 mm bore complete all as specified and directed by Engr-in-charge. |
| 27 | Suply and fixing in replacement of cast iron NRV flanged end of size 200 mm dia with all fitting and accessories,complete all as specified and directed by Engr-in-charge. |
| 28 | All as per item no: 27 above but 150 mm dia, complete all as specified and directed by Engr-in-charge. |
| 29 | All as per item no: 27 above but 100 mm dia, complete all as specified and directed by Engr-in-charge. |
| 30 | All as per item no: 27 above but 80 mm dia, complete all as specified and directed by Engr-in-charge. |
| 31 | All as per item no: 27 above but 50 mm dia, complete all as specified and directed by Engr-in-charge. |
| 32 | Taking down carefully cast iron sluice valve of size 200 mm bore from CI water mains, dismantling parts and reassembling, replacement of ss spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refacing, regrinding and refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and directed by Engr-in-charge. |
| 33 | All as above item No: 32, but for 150mm dia sluice valve, complete all as specified and directed by Engr-in-charge. |
| 34 | All as above item No: 32, but for 100mm dia sluice valve, complete all as specified and directed by Engr-in-charge. |
| 35 | All as above item No: 32, but for 80mm dia sluice valve, complete all as specified and directed by Engr-in-charge. |
| 36 | Taking out existing U/S CI sluice valve of any size any pattern up to 200 mm bore complete all as directed. |
| 37 | S&F in repalcement of Cast iron sluice valve of size 80 mm dia Stainless steel stemPN- 1.6 ( Flanged) conforming to IS 14846 hand wheel operated,complete all as specified and directed. |
| 38 | All as per Item No 37 Above but 100 mm dia, complete all as specified and directed by Engr-in-charge. |
| 39 | All as per Item No 37 Above but 150 mm dia, complete all as specified and directed by Engr-in-charge. |
| 40 | All as per Item No 37 Above but 200 mm dia, complete all as specified and directed by Engr-in-charge. |
| 41 | Supply and laying in replacement of galvanised steel water tubing medium grade in trenches / wall /floor with all fittings , connections as required at site of size 15 mm bore, complete all as specified and directed by Engr-in-charge. |
| 42 | All as per Item No 41 Above butBore of pipe 20 mm, complete all as specified and directed by Engr-in-charge. |
| 43 | All as per Item No 41 Above butBore of pipe 25 mm, complete all as specified and directed by Engr-in-charge. |
| 44 | All as per Item No 41 Above but Bore of pipe 50mm, complete all as specified and directed by Engr-in-charge. |
| 45 | All as per Item No 41 Above but Bore of pipe 80mm, complete all as specified and directed by Engr-in-charge. |
| 46 | All as per Item No 41 Above but Bore of pipe 100mm, complete all as specified and directed by Engr-in-charge. |
| 47 | S&F in replacement of Stop valve gun metal valve with iron handle screwed both ends for iron pipe and fixed of size 15 mm bore, complete all as specified and directed by Engr-in-charge. |
| 48 | All as per Item No 47 Above butBore of pipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 49 | All as per Item No 47 Above butBore of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 50 | All as per Item No 47 Above but Bore of pipe 50mm, complete all as specified and directed by Engr-in-charge. |
| 51 | S&F in replacement of GI socket of 15 mm ISI marked complete all as specified and directed by Engr-in-charge. |
| 52 | All as per Item No 51 Above butBore of pipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 53 | All as per Item No 51 Above butBore of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 54 | All as per Item No 51 Above but Bore of pipe 50mm, complete all as specified and directed by Engr-in-charge. |
| 55 | S&F in replacement of GI union of 15 mm ISI marked complete all as specified and directed by Engr-in-charge. |
| 56 | All as per Item No 55 Above butBore of pipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 57 | All as per Item No 55 Above butBore of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 58 | All as per Item No 55 Above but Bore of pipe 40 mm, complete all as specified and directed by Engr-in-charge. |
| 59 | All as per Item No 55 Above but Bore of pipe 50 mm, complete all as specified and directed by Engr-in-charge. |
| 60 | S&F in replacement of GI nipple of 15 mm, 6 \" longISI marked complete all as specified and directed by Engr-in-charge. |
| 61 | All as per Item No 60 Above butBore of pipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 62 | All as per Item No 60 Above butBore of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 63 | All as per Item No 60 Above but Bore of pipe 40 mm, complete all as specified and directed by Engr-in-charge. |
| 64 | All as per Item No 60 Above but Bore of pipe 50 mm, complete all as specified and directed by Engr-in-charge. |
| 65 | S&F in replacement of GI elbow of 15 mm medium grade ISI marked complete all as specified and directed by Engr-in-charge. |
| 66 | All as per Item No 65 Above butBore of pipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 67 | All as per Item No 65 Above butBore of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 68 | All as per Item No 65 Above but Bore of pipe 40 mm, complete all as specified and directed by Engr-in-charge. |
| 69 | All as per Item No 65 Above but Bore of pipe 50 mm, complete all as specified and directed by Engr-in-charge. |
| 70 | S&F in replacement of GI Reducer of 20x15 mm medium grade ISI marked complete all as specified and directed by Engr-in-charge. |
| 71 | All as per Item No 70 Above but Bore of pipe 25x20 mm complete all as specified and directed by Engr-in-charge. |
| 72 | All as per Item No 70 Above but Bore of pipe 40x25 mm complete all as specified and directed by Engr-in-charge. |
| 73 | All as per Item No 70 Above but Bore of pipe 50x40 mm complete all as specified and directed by Engr-in-charge. |
| 74 | All as per Item No 70 Above but Bore of pipe 50x25 mm complete all as specified and directed by Engr-in-charge. |
| 75 | S&F in replacement of GI Tee of 15mm medium grade ISI marked complete all as specified and directed by Engr-in-charge. |
| 76 | All as per Item No 75 Above butBore of pipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 77 | All as per Item No 75 Above butBore of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 78 | All as per Item No 75 Above but Bore of pipe 40 mm, complete all as specified and directed by Engr-in-charge. |
| 79 | All as per Item No 75 Above but Bore of pipe 50 mm, complete all as specified and directed by Engr-in-charge. |
| 80 | S&F Dead plug of size 15mm to 50mm dia complete all as specified and directed by Engr-in-charge. |
| 81 | Supply & laying/fixing in replacement of 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded PP-R (polypropylene Random Co-Polymer) pipes, ISI marked including plain PP-R fittings and brass threaded PP-R fittings such as flanges, elbow, bend, sockets, tee etc. as required at site and testing of joints of size (a) PN-16, 32mm OD (SDR– 7.4) including taking out old rusted GI pipe of 50mm dia complete all as specified and directed by Engr-in-charge. |
| 82 | All as above item No: 81,but for 63mm outer dia, complete all as specified and directed by Engr-in-charge. |
| 83 | All as above item No: 81,but for 90mm outer dia, complete all as specified and directed by Engr-in-charge. |
| 84 | S&F in replacement of PPR union of size 32mm dia including connection and testing complete all as specified and directed. |
| 85 | All as above item No: 84, but for 63mm dia, complete all as specified and directed by Engr-in-charge. |
| 86 | All as above item No: 84, but for 90mm dia, complete all as specified and directed by Engr-in-charge. |
| 87 | S&F in replacement of PPR socket of size 32 mm dia including connection and testing complete all as specified and directed. |
| 88 | All as above item No: 87, but for 63mm dia, complete all as specified and directed by Engr-in-charge. |
| 89 | All as above item No: 87, but for 90mm dia, complete all as specified and directed by Engr-in-charge. |
| 90 | S&F in replacement of PPR MTA of size 32 mm dia including connection and testing complete all as specified and directed. |
| 91 | All as above item No: 90, but for 63mm dia, complete all as specified and directed by Engr-in-charge. |
| 92 | All as above item No: 90, but for 90mm dia, complete all as specified and directed by Engr-in-charge. |
| 93 | S&F in replacement of PPR elbow of size 32 mm dia including connection and testing complete all as specified and directed. |
| 94 | All as above item No: 93, but for 63mm dia, complete all as specified and directed by Engr-in-charge. |
| 95 | All as above item No: 93, but for 90mm dia, complete all as specified and directed by Engr-in-charge. |
| 96 | S&F in replacement of PPR Teeof size 32 mm dia including connection and testing complete all as specified and directed. |
| 97 | All as above item No: 96, but for 63mm dia, complete all as specified and directed by Engr-in-charge. |
| 98 | All as above item No: 96, but for 90mm dia, complete all as specified and directed by Engr-in-charge. |
| 99 | S&F in replacement of PPR gate valve (brass insert) of size 63 mm dia including connection and testing complete all as specified and directed including taking out old unserviceable gun metal gate valve 50mm dia Complete all as specified and directed |
| 100 | All as above item no: 99, but of size 32mm, complete all as specified and directed by Engr-in-charge. |
| 101 | Dismounting of monoblock 02 HP pumpand motor from foundation including disconnecting all electric connection suction / delivery line connection andtransporation to pumping set civil work shop and return to store after repair including Re- assembing of motor and testing and commissioning all as specified and directed. |
| 102 | Taking out the pump from the motor and rewinding of02 HP motor with super enamelled copper wiresame gauge & size includinng all insulating material ie. sleeves stick and insulation sheet. and replacement of the following parts. (a) Replacement of driving and non driving end ball bearing-02 Nos.(b) Balanceing of rotor including straightening of strip -02 Job.(c) Replacement of bearing bush upper and lower-02 Nos.(d) Repair to pump & its seals etc-1 Nos |
| 103 | S&F in replacement Pressure booster pump 0.5HP, 230 Volt, 50 Hz of 25mm dia inlet & oulet pipe dia complete all as specified and directed by Engr-in-Charge. |
| 104 | Taking out existing U/S valve chamber incl brick work & PCC work complete all as directed. |
| 105 | M&Lin replacement for construction of valve chambers with MS cover 3 mm thick of valve pit of size 900x900x900 MM( internal dimensions) including necessary excavation, earth work 150 mm thickPCC 1:4:8 Type D2 as in foundation, PCC 1:2:4 Type B1 in coping plastering 15 mm thick in cm 1:4,and angle iron frame50x50x06 mm and locking arrangement including painting with coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as specified and directed by Engineer-in-charge. |
| 106 | Removing of u\s leakage tank from roof /Surface and disconnecting all fitting and fixture. Up to 1000 ltr from 5000 ltr. All as directed by Engineer-in-charge. |
| 107 | Supply and fixing in replacement of rotational moulded polyethy lene water storage tank (cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part I. of size 1000 Ltrs. Make- Sintex |
| 108 | All as per item No 107 but 2000 ltr,complete all as specified and directed. |
| 109 | All as per item No 107 but 5000 ltr,complete all as specified and directed. |
| 110 | Removing of the existing u/s float valve from the tank of any capacity, complete all as specified and directed. |
| 111 | Supply and fixing in replacement of PVC float valves ( Ball valve) high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed, of size 15 mm dia.including all fittings, complete all as specified and directed. Make- prayag or equivalent make |
| 112 | All as per item No 111 but 20 mm dia, complete all as specified and directed. |
| 113 | All as per item No 111 but 25 mm dia, complete all as specified and directed. |
| 114 | All as per item No 111 but 50 mm dia, complete all as specified and directed. |
| 115 | Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed by Engr-in- charge. |
| 116 | M&L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft soil, complete all as specified & directed. |
| 117 | Retuning filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed by Engr-in- charge. |
| 118 | Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting pointall as specified. |
| 119 | M&L for manual Boring of holes under road, pavement, Hard standing by trenchless technique, for passing GI/CI/DI pipe upto 100mm dia, complete all as specified and directed by Engr-in-charge. |
| 120 | M& Lfor minor reparing / rectified and attending the complaint of pipe line leakage and reparing of any size by highly skilled trades man and making functional including all GI fittings like elbow, socket, Tee, Nipple, bend, union etc and making new threads as required at site including excavation,return refilling and removing soil & earth work etc. complete all as specified and directed. |
| 121 | S&F in replacement Submersible cable PVC insulatedcopper conductor flat 3 core 4 sqmm 1100 volt, complete all as specified and directed. |
| 122 | S&F in replacement Submersible cable PVC insulatedcopper conductor flat 3 core 6 sqmm 1100 volt, complete all as specified and directed. |
| 123 | S&F copper lugs size varying from 6 sq mm to 35 sqmm for jointing cable, all as specified and directed by Engr-in-Charge. |
| 124 | S&F Aluminium lugs size varying from 25 sq mm to 95 sqmm for jointing cable, all as specified and directed by Engr-in-Charge. |
| 125 | Supply only Chlorine Testing kit with coloured ample complete with all testing fitments and OT solution in Rexene finish box complete all as specified & directed. |
| 126 | M&L for Removal of the existing paint from the pumping set & LT panel of any sizeby the hand scrapping and painting gray colour for the motor, Blue colour for pumps and black colour for the pump base& grey for LT panel with two coat of synthetic enamel paint and rewriting the SM NO. All as specified and directed by Engr-in- charge. |
| 127 | M&L for Removal of the existing paint from the suction and discharge pipe line upto 200mm dia by the hand scrapping and painting black colour for the suction line and discharge line with two coat of synthetic enamel paint, all as specified and directed by Engr-in- charge. |
| 128 | S&F in replacement Nut, bolt, washer of different size ISI marked, complete all as specified and directed. |
| 129 | S&F in replacement lather gasket ISI marked, complete all as specified and directed. |
| 130 | Supply in repair of grease for pump servicing and filling of gland dori in pumpISI marked,complete all as specified and directed. |
| 131 | Testing of Raw Water/Treated water for bacteriological analysis, Chemical analysis & dissolved salts i.e. manganese, arsenic, nitrates, Fluoride etc, parameters confirming as per IS:10500-2012from any Govt. Approved/recognized Lab as approved by the GE.Note:- 1) Contractor has to collect samples from various pump houses & borewells in Vayusenabad on alternately basis from different sources as directed by Engr-in-charge.2) Contractor will be responsible to carry out the sample & submitreport timely. |
| 132 | Taking out floor nozzle from the pool M&L for fixing including testing of single hole/eye ball floor inlet nozzle as per sample existing at site of 40/50 mm bore as per site requirement complete all as specified and directed by Engr-in-Charge. |
| 133 | M&L in replacement for MCCB 3 pole 160 amps, thermal adjustable magnetic type, 36 KA complete all as specified and directed by Engr-in-Charge. |
| 134 | M&L in replacement for MCCB 4 pole 160 amps, thermal adjustable magnetic type, 25 KA complete all as specified and directed by Engr-in-Charge. |
| 135 | M&L in replacement for MCCB 3 pole 250 amps,thermal adjustable magnetic type, 35 KA complete all as specified and directed by Engr-in-Charge. |
| 136 | M&L in replacement for MCCB 4 pole 250 amps,thermal adjustable magnetic type, 50 KA complete all as specified and directed by Engr-in-Charge. |
| 137 | M&Lin replacement of ampere meter digital type, 415V suitable for existing panel CT operated of range 0-100 as required complete all as specified and directed by Engr-in-Charge. |
| 138 | M&Lin replacement of ampere meter digital type, 230V suitable for existing panel CT operated of range 0-100, complete all as specified and directed by Engr-in-Charge. |
| 139 | M&Lin replacement of voltmeter digital type, 415V suitable for existing panel CT operated of range 0-500, complete all as specified and directed by Engr-in-Charge. |
| 140 | M&Lin replacement of LED indicator lamp, complete all as specified and directed by Engr-in-Charge. |
| 141 | M&Lin replacement of panel mounted ON/OFF push button with contact block, ccomplete all as specified and directed by Engr-in-Charge. |
| 142 | M&L in replacement of CT50/5 complete all as specified and directed by Engr-in-Charge. |
| 143 | Supply & fixin replacement of Electronic timer 415 Volt, 50 Hz range 3-10 Secs complete all as specified and directed by Engr-in-Charge. |
| 144 | S&F in replacement of Single phase preventer 6 wire, 415Vsuitable for pumps starter as per ground reqirement, complete all as specified and directed by Engr-in-Charge. |
| 145 | M&Lin replacement of Single phase preventor VSP 2 auto/manual reset of any size , 415V complete all as specified and directed by Engr-in-Charge. |
| 146 | Supply & fixin replacement of contactor MNX18 suitable for direct mounting, complete all as specified and directed by Engr-in-Charge. |
| 147 | Supply & fixin replacement of contactor MNX32 suitable for direct mounting,complete all as specified and directed by Engr-in-Charge. |
| 148 | S&F in replacement of Add-on block with 2NO+2NC, 215V, complete all as specified and directed by Engr-in-Charge. |
| 149 | M&L in replacement of Electronic overload relay (Manual reset) relayrange 9-16 amp suitable for direct mounting,complete all as specified and directed by Engr-in-Charge. |
| 150 | M&L in replacement of Electronic overload relay (Manual reset) relayrange 15-23 amp suitable for direct mounting,complete all as specified and directed by Engr-in-Charge. |
| 151 | Supply only Calcium based granule Chlorine (calcium hypochlorite) having chlorine content upto 68% disinfect for water treatment complete all as specified and directed by Engr-in-Charge. |
| 152 | S&F in replacement single phase Direct on line starter of capacity 2 HP overload relay range 9-14 Amp complete all as specified and directed by Engr-in-Charge. |
| 153 | S&F of centrifugal Monoblock pump set with motor, Single Phase, 230V, 5.3-2.25 LPS at 8-26 Mtr head system having capacity 2 HP, suction/delivery size 50x 40mm dia with all connected accessories complete all as specified and directed by Engr-in-Charge.Note: 1) Contractor has to deposite old pump set to MES store in custody of concerned JE.2) Necessary fittings required for connection/header, foundation & shed for pumps is deemed to be included in quoted rates. |
| 154 | Supply and fixing in replacement of suction sweeper trolly wheel with rings complete as per sample complete all as specified and directed by Engr-in-Charge |
| 155 | Supply and fixing in replacement of deep bag net made from Polypropylene and white Polyster netting with 1.5\" butterfly nut/clip connection and suitable to trap deep pool larger sedimennts, complete all as specified and directed by Engr-in-Charge. |
| 156 | M&L for cleaning of complete Swimming pool by dewatering of water and cleaning to be done from the bottom and side walls scrubbing with brush for removing fungus and washing with hydrochloric acid mixing with water after removing all the sediments collected at the bottom of the pool and balancing tank all as specified and directed by Engr-in-charge |
| 157 | All as per item No 156 but cleaning of Balancing tank, complete all as specified and directed. |
| 158 | Supplying, injecting and mixing of alum crysal of approved quality with ISI mark in swimming pool through dozing system installed complete all as specified and directed by Engr-in-Charge. |
| 159 | Supplying, injecting and mixing of soda ash of approved quality with ISI mark in swimming pool through dozing system installed complete all as specified and directed by Engr-in-Charge. |
| 160 | Supplying, injecting and mixing of TCC-90 of approved quality with ISI mark in swimming pool through dozing system installed complete all as specified and directed by Engr-in-Charge. |
| 161 | Supplying, injecting and mixing of pool water, hydrochloric acid has proven to be profoundly effective at removing algae from the floors and walls of a pool while also lowering pH levels & dozing system installed complete all as specified and directed by Engr-in-Charge. |
| 162 | Supplying, injecting and mixing of Copper Sulphate of approved quality with ISI mark in swimming pool through dozing system installed complete all as specified and directed by Engr-in-Charge. |
| 163 | Supply and fixingin replacement of FPBC nylon flexible hose pipe premium grade 40 mm outer dia size heavy duty capacity suitable for suction sweeper complete all as specified and directed by Engr-in-Charge. |
| 164 | Supply and fixingin replacement of nylon rope, 25 mm outer dia size complete all as specified and directed by Engr-in-Charge. |
| 165 | M&L for fixing in replacement of Cast Iron butterfly valve (wafer Type) of following size without lugs, lever operated, SS 304 Disc, Nitrile /EPDM rubber lining test pressure PN-1.2 for the following size, complete all as specified and directed by Engr-in-Charge. |
| 166 | All as per item No: 165 above, but of 50 mm dia, complete all as specified and directed. |
| 167 | All as per item No: 165 above but of 100 mm dia, complete all as specified and directed. |
| 168 | All as per item No: 165 above but of 150 mm dia, complete all as specified and directed. |
| 169 | All as per item No: 165 above but of 200 mm dia, complete all as specified and directed. |
| 170 | S&F in replacement of CI Foot Valve of 200mm dia complete all as specified and directed by Engr-in-Charge.Note: contractor has to make neccessary arrange by chain pulley for lifting & lowering CI footvalve & 200mm dia MS pipe of length at a depth of 8mtr in UG sump, including nut bolt washer, gasket of any size & quantity. Any damage to CI pipe will be repaired by contractor without any extra charge. |
| 171 | M&L for Servicing of centrifugal coupled monoblock pumpset including gland dori fixing, greasing, oiling, replacement ofnut bolt, oil seal, rubber coupling, gland doori cooling pipe assembly, opening top cover of pump & removing debris accumulated in pump suitable for pumpset of capacity 20HP-60HP, complete all as specified & directed by Engineer-in-charge.Note:Gasket of any size, nut bolt washer of any size & qty, T&P & labour required for lifting of pump & its top cover is deemed to be included in quoted rates |
| 172 | Taking down old unserviceable and Supply and fixing following swimming pool item,complete all as specified and directed. |
| 173 | Standard wall Brush 18\" of SS material |
| 174 | 18” Brush- Alu Back of SS material |
| 175 | Leaf Skimmer |
| 176 | Deep Leaf Rake |
| 177 | Telescopic Pole 8 Meters of Aluminium material |
| 178 | Deluxe large Vac head,4 wheels,SS body,SS hande (3 ft.) |
| 179 | M&L for replacing uncharged and non cogulant sand media and marble stone aggregate of suitable grade and size for pressure filter (650LPM) of size 1000mm dia made of FRP floor mounted in alternate layers- 4 Nos , complete all as specified and directed. |
| 180 | Labour/service charged for removing old charged & cogulated sand media layer by layer including filter membranes and making new layers of sand, marble stone aggregate and filter membrane both vertical in center of vessel and between each layers sand and stone of suitable thickness and compressing it properly and the testing, commissiong filters as specified and directed by EIC.Note:(1) Rate of filter membrane of any size, type, grading and quantity as per existing is deemed to be included in quoted rate.(2) Rate are deemed to be inclusive of lifting arrangement of vessel like hydra, T&P and labour required at site.(3) Repair of minor defect encounter during overhauling of sand filter media filter is deemed to be included in quoted rate. (4) Acid and other cleaning agent required for cleaning of inner surface of vessel is deemed to included in quoted rate.(5) Rate are deemed to be inclusive of uPVC fittings (any type, size and quantity) required at site for disconnecting and refixing vessels after overhauling.(6) Rate are deemed to inclusive of repair to vessel if any damage caused to vessel and fitting due to mishandling by labour during execution of work. |
| 181 | S&F in replacement of multiport valve suitable, 650LPM, 900mm dia vessel having 63mm outlet/inlet bore with 6 way water flow, vertically side mounted on vessel with 360 degree rotating handle (made of high strength plastic), including valve to be properly consealed, tighten and leakage proof, complete all as specified and directed. |
| 182 | All as above item No: 171, but 63mm outlet/inlet bore with 6 way flow, top mounted on vessel, complete all as specified and directed. |
| 183 | S&F in replacement of PVC pipe of 63mm dia suitable for 10kg/cm2 pressure bearing capacity including all fittings like socket, elbow, tee etc., complete all as specified & directed. |
| 184 | S&F in repalcement of PVC union of 63mm dia along with necessary reducers as required on site, complete all as specified & directed. |
| 185 | S&F in replacement of underwater LED light of 20 watt with IP66 protection, 35000K temp, 100mm dia dial size, SS body, complete all as specified & directed. |
| 186 | S&F in replacement of SS body housing suitable for underwater LED light of 3mm thic round in shape, four nos holes for cable, complete all as specified & directed. |
| 187 | S&F in replacement of SMPS suitable for underwater LED light of 20 watt, complete all as specified & directed. |
| 188 | M&L in replacement of pressure gauge to read in IS/BSunit type KG/cm2 and LB/inc2 reading marked 0-2, 0-30 respectively including taking old one complete all as specified and as directed. |
| 189 | Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc all as specified as directed. |
| 190 | Material & Labour for concealed point wiring with single core PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including non metallic rigid PVC conduit (circular/flat pvc conduit), medium duty not less than 20 mm dia concealed in wall/fixed on wall/ceiling with GI saddles , GI screws , rawl plugs with all fittings including tees , junction boxes including fixing GI gang box of any module not less than 3.15mm thickness flushed in wall with hylem cover sheet of suitable size for mounting switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmmcomplete all as specified & directed by Engineer -In-Charge.Note: Cost for cutting chases in any type of wall/ceiling and supply & flushing conduit pipe, junction box, tee, PVC flexible pipe and GI gang box ( any qty, Nos & module) and making good to match the existing surface shall be deemed to be included in the quoted rate. |
| 191 | For one light point controlled by one single pole switch & socket. |
| 192 | For one fan point controlled by one single pole switch. |
| 193 | For one 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm |
| 194 | For 3 pin socket outlet 5Amps independent with cable 1.5 Sqmm size |
| 195 | For one 3 pin sockets outlet 15 Amps idependent with cables 2.5sqmm size |
| 196 | Supply and Fixing in replacement ofmodular switches 1 way, 6 Amp 1 module complete all as specified & directed by Engineer - In-Charge. |
| 197 | Supply and Fixing in replacement of modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified & directed by Engineer - In-Charge. |
| 198 | Supply and Fixing in replacement ofmodular switches 1 way, 16 Amp 1 module complete all as specified & directed by Engineer - In-Charge. |
| 199 | Supply and Fixing in replacement ofmodular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified & directed by Engineer - In-Charge. |
| 200 | S&Fin replacement ofstepped type electronic fan regulator flush type 1 module, complete all as specified & directed by Engineer - In-Charge. |
| 201 | Supply & Fixing in replacement ofCeiling Rose, 3 phase polycarbonate isolated body including hylem/plastic round shape junction box cover & brass screw nuts, complete all as specified & directed by Engineer - In-Charge. |
| 202 | Supply and fix in replacement of factory made epoxy polyster powder coated distribution board SP&N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incomingand 6 outgoings confirming to IS: 8623 and complete all as specified and directed by Engr-in-Charge. Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. |
| 203 | S&F in replacement of Wiring for circuit/submain wiring alongwith earth wire in PVC conduit pipe with wire of2x4.0 sq. mm + 1x2.5 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required, complete all as specified & directed. |
| 204 | S&F in replacement of RCCB 32Amps of 30mA cat. single pole \"C\" curve, complete all as specified & directed. |
| 205 | S&F in replacement of RCCB 100Amps of 30mA cat. double pole \"C\" curve, complete all as specified & directed. |
| 206 | S&F in replacement of Pressure cutoff switch suitable for 0.5HP inline pressure pump, complete all as specified and directed by Engr-in-Charge. |
| 207 | S&F of Capacitor 50Mfd for pumpset of 2HP as per site requirement, complete all as specified & directed. |
| 208 | M&L for cutting of grass, trimming of trees, removing stone, glass, metals etc by deploying sufficient no of labour as or when required and removing & disposing dry leafs, shurbs, branches etc. away from pumphouse, complete all as specified and directed by Engr-in-Charge.Note: contrctor has to provide cutting tools, shovel, trowel, axe, gloves etc |
| 209 | S&F in replacement of fountain water submerged fountain light of 18/20watt, of IP66 protection, in SS casing, remote controlled, RGB colour changing/RGB controller, complete all as specified and directed by Engr-in-Charge. |
| 210 | S&F in replacement of SMPS enclosed in sheet metal box with fuse of suitable capacity and of suitable rating as per site forfountainlight of 18/20watt,complete all as specified & directed. |
| 211 | S&F in replacement of Fountain nozzels (SS/heavy duty plastic)as per site requirement, including repairing/replacement of PVC pipe upto 63mm dia, solvent, insulation tape etc. per fountain, complete all as specified and directed by Engr-in-Charge. |
| 212 | S&F in replacement of Submersible cable 2 core 1.5sqmm for fountains, complete all as specified & directed. |
| 213 | Supply and fix in repair of rubber coupling suitable for 20/40 HP pump set as per existing pattern complete all as specified and directed by Engr-in-Charge. |
| 214 | S&F in repair of MS/GI Flange of size 50 to 200 mm and fixing of new one MS/GI Flange at same location where MS/GI Flange is taken out including nuts bolts etc all as specified and directed. |
| 215 | Supply and fixing in repair of pre-fabricated MSstructural steel (IS marked) work consisting of channels / angles /flats/ round bars/MS pipe &other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting for hanging strcture for repair bay all as directed by Engr in Charge. |
| 216 | M&L in Repair of RustedCI Tail Piece of size 80mm to 200 mm at same location where CI Tail Pieceis taken outcomplete all as specified & directed by Engineer - In-Charge. |
| 217 | M&L for demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) for HDPE tank foundations, complete all as specified & directed by Engineer - In-Charge. |
| 218 | M&L for hard core of broken stone or boulders of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surface complete all as specified & directed by Engineer - In-Charge. |
| 219 | M&L for Cement concrete in foundations, filling and mass concrete of Type C2 (1:3:6), (40 mm graded aggregate) for 5000Ltrs HDPE tank foundation, motor foundation etc. complete all as specified & directed by Engineer - In-Charge. |