| 1 | Providing wood work in frames ofwalls,false ceiling, partitions etc. sawn and fixed in position :Budloo / Fir wood |
| 2 | Providing and fixing 12 mm thick tongued and grooved Pine wood(Soft Wood ) 4-5 inch in width panelling or wall panels in walls and celingincludining all necessary fixtures including cornice with necessary screws, priming coat on exposed surface etc., complete. Brand - Rait Wood |
| 3 | Providing and fixing 32mm -50mm thick wooden planks (frame work for base to be paid for separately) with M.S. screws complete. 2nd class kail wood |
| 4 | Providing and fixing 19mm plywood of approved brand including all necessary fixtures complete. |
| 5 | Providing and fixing sumica plywood 6mm thick of approved brand including all necessary fixtures complete |
| 6 | Preparing newly prepared panneled surface for polishing by way of filling of putty , sealer andsand papering rubbing and applying hard polish,glossy polish in sequance over the prepared surface complete job |
| 7 | Providing and fixing thermal insulation with specified wool and density conforming to IS: 8183, 50 mm thick, wrapped in 200G Virgin Polythene bags fixed to walls with screws, rawl plugs and washers and held in position by criss-crossing GI wire etc. complete as per directions of Engineer-in-charge. |
| 8 | With resin bonded rock wool with density 48 kg/cum |
| 9 | Providing and fixing glazing in window, ventilator shutters and partitions etc. with wooden bidding etc. complete as per the drawings and the directions of engineer-in-charge. With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)Qty vide openings @80% |
| 10 | Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing completeAgaria White 16mm |
| 11 | Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete i.e Size of tile 600x600 mm |
| 12 | Providing and fixing wash basin with C.I./M.S. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 13 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps JAGUAR / CERA/HINDWARE Make |
| 14 | P/F of mirrors of superior glass with plastic moulded frame(of approved quality) and of required size and shape. With 6mm thick hard board backing. Rectangular Shape 1500 x 450 mm |
| 15 | Providing and fixing soil waste & vent pipe |
| 16 | PVC Pipe. 110mm dia (10 feet unit Length) |
| 17 | PVC Pipe. 75mm dia (10 feet unit Length) |
| 18 | PVC Bend 110mm dia |
| 19 | PVC Bend 75mm dia |
| 20 | PVC Flow trap 75mm dia |
| 21 | PVC Tee 110mm dia |
| 22 | PVC Tee 75mm dia |
| 23 | PVC Door Tee 110mm dia |
| 24 | PVC Door Tee 75mm dia |
| 25 | PVC Collar 110mm dia |
| 26 | PVC Collar 75mm dia |
| 27 | Providing and fixing 3 layer Thermex Pipe PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 28 | PN-16 pipe , 25mm OD(SDR-7.4) |
| 29 | PN-16 pipe , 32mm OD(SDR-7.4) |
| 30 | P/F CP brass toilet paper holder including cost of wodden,PVC,play etc. |
| 31 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 32 | 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 33 | Providing and fixing accessories of standard and quality make of approved manufacturer including all necessary fixtures required. |
| 34 | L-Drops for room door |
| 35 | Handles for door |
| 36 | Handels for window |
| 37 | 15 mm C.P. brass bib cock short body |
| 38 | 15 mm C.P. brass two way bib cock |
| 39 | 15 mm C.P. brass mixer wall mounted |
| 40 | 15 mm C.P. brass angle valve |
| 41 | PVC connection for gaysers /washbasins/cistern |
| 42 | P/F Gayser of 35litres Capacity of approved brand including all necessary fixtures complete. |
| 43 | P/F Handles with lock system of main doors ( Godrej Make) |
| 44 | P/F cera ormond soap dish |
| 45 | P/F over head shower |
| 46 | Providing and installation ofPUF (Puf Insulated Tanks) water tank capacity 1000 ltrs of approved brand (SYNTEX OR ANY OTHER APPROVED BRAND) as per direction engineer incharge |
| 47 | Providing and installation ofKitchen Sink of any approved brandas per direction engineer incharge |
| 48 | Supply and installation of High Quality self regulating heat tracerfor Specialized Heating Solutions for Winterisation of water pipeline including all accessoriescompleteincluding Supply and installation ofCircuit Control Panel with RCBO MCB ,THERMOSTAT (0-120) DEG C, power connector-two way-6 sq.mm, w.p. splice connector,w.p. tee connector,end seal,mounting kit-w.p. jb,g.i. pipe strap 4\",al. adhesive tape roll( 50 mm w x 20 m l),f.g. adhesive tape roll (DANFOSS Make OR CHROMALOXany other approved brand as per the direction of Engineer-In-Charge) |
| 49 | Supplying and fixing High Quality32mm ThickNitrile Insulation Tube for water pipelineof approved brand2 InchSize (Armaflex Class-o Armacell) including alumunium duct clading of approved quality and finish as per the direction of engineer in charge |
| 50 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. |
| 51 | SOAKAGE PIT FOR KITCHEN |
| 52 | Excavation work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains(not exceeding 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.(SIZE 6\" X 6\" ) |
| 53 | ORDINARY ROCK=80% |
| 54 | ALL KIND OF SOIL=20% |
| 55 | Disposal of Mulba/Excavated Earth Beyond 50m (Lead upto 6Km) Outside Town Area (CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking) |
| 56 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 57 | Dry random rubble masonary with hard stone in foundation & plinth using Nallah stone without bond stone |
| 58 | Reinforced cement concrete work in suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 59 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 60 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 61 | Suspended floors, roofs, landings, balconies and access platforms. |
| 62 | Supplying and fixing C.I. cover without frame for manholes: 560 mm diameter C.I. cover ( heavy duty) |
| 63 | Electrict. |
| 64 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit,with modular switch.modular plate.suitable GI Box and earthing point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. |
| 65 | Wiring for Circuit/Submain wiring along with earth wire of the following size of FR PVC insulated copper conductor single core cable in surface/recessed conduit as required. |
| 66 | 2x2.5 sq.mm + 1x2.5 sq.mm earth wire (circuit wire) |
| 67 | 2x4 sq.mm + 1x4 sq.mm earth wi.re |
| 68 | 2x6 sq.mm + 1x4 sq.mm earth wire (Main panel to DB) |
| 69 | 2x10 sq.mm + 1x6 sq.mm earth wire (Main panel to DB) |
| 70 | S/F of following Specification of Surface/recessed LED lighting fixture. |
| 71 | LED 12W Surface Panel of lumen more than 1100 Round Shape. |
| 72 | P/F of exhaust fan shutter type 250 mm including making hole to suit the above fan making good the as required |
| 73 | Supply installation/testing & Commissioning of LED flood light 50W With complete accessories |
| 74 | S/F of following size/modular GI Box along with modular base & cover plate for switch /socket in recess etc as required |
| 75 | 1or 2 modular (75mm x 75mm) |
| 76 | 3 modular (100mm x 75mm) |
| 77 | 4 modular (125mm x 75 mm) |
| 78 | 6 modular (200mm x 75 mm) |
| 79 | 8 modular (150mm x 150mm) |
| 80 | S/F following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required. |
| 81 | 6 amp Switch |
| 82 | 16 amp Switch |
| 83 | 3 pin, 6 amp Socket outlet |
| 84 | 6 pin, 16 amp Socket outlet |
| 85 | Indicator lamp |
| 86 | MCB Distribution Board: |
| 87 | S/F Double door MCB distribution boards, 240V, Sheet steel, Powder coated DB’s suitable for MCB’s fitted with Bus Bar, Neutral link, Earth Bar and Din bar of following no. of ways: |
| 88 | 16 way double door SP&N |
| 89 | S/F of 5 Amps to 63 Amps, 240V, “B series, ISI Mark” miniature circuit breakers suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required: |
| 90 | Single pole 6A/10 A, SP MCB |
| 91 | Single pole 16A/32 A,SP MCB |
| 92 | Double pole 40A, DP MCB |
| 93 | Double pole 63,=A, DP MCB |
| 94 | 100A, 4PChangeover Switch |
| 95 | Earthing with Cu.earth plate 600mm x 3.5 mm thick along with connection from the earth plate by a copper strip of size 2R x 25mm x 5mm up to the earthing terminal in panel room including accessories and providing masory enclosure with cover plate having locking arrangement and watering pipe of 3.2 mtr.long etc.with charcoal or coke and salt of 1.8 Cum as required.Depth of earthing must be to feet from the ground level |
| 96 | Supply and laying of following size and specification of XLPE insulated PVC Sheathed armoured cable with aluminum conductor for working voltage 1100 V grade as per IS:7908,including thimble/lugs,double compression gland etc,of respective size |
| 97 | 35 sq.mm 2 C X Armoured Cable |
| 98 | Supplying and laying of following size DWC HDPE Pipe ISI marked along with all accessories like socket,bends,couplers etc conforming IS 14930,Part II Complete with fitting and cutting,joining etc.direct in ground (45 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc,complete as required. |
| 99 | 65 mm dia (OD-90 mm & ID -54 mm nominal) |