Tender For Repair And Maintenance Of Internal Wiring, Geyser, Fans, Exhaust Fans And Other Connected Items At Af Station Mullanpur Under Age (I) Highground Chandigarh, Chandigarh-Chandigarh

Military Engineer Services has published Tender For Repair And Maintenance Of Internal Wiring, Geyser, Fans, Exhaust Fans And Other Connected Items At Af Station Mullanpur Under Age (I) Highground Chandigarh. Submission Date for this Tender is 17-06-2024. Electrical Maintenance Tenders in Chandigarh Chandigarh. Bidders can get complete Tender details and download the document.




Tender Notice

43467844
Tender For Repair And Maintenance Of Internal Wiring, Geyser, Fans, Exhaust Fans And Other Connected Items At Af Station Mullanpur Under Age (I) Highground Chandigarh
Tender
Indian
Chandigarh
Chandigarh
17-06-2024

Tender Details

Repair And Maintenance Of Internal Wiring, Geyser, Fans, Exhaust Fans And Other Connected Items At Af Station Mullanpur Under Age (I) Highground Chandigarh-Taking down carefully with battens/ PVC surface/ concealed conduit unserviceable copper/ aluminium point wiring (light, fan, socket) complete including fittings such as switches, ceiling roses, pendants, socket etc. and removing unserviceable material from site and making good disturbed surfaces of walls, floors etc. complete all as specified and directed. 2 Point wiring PVC insulated sheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mountingswitches, sockets,fan regulators etc including all necessary wall cutting chasis and making good disturbed surfaces in cement mortar 1:3 and as per existing colour of white wash / paint / OBD / cement base paint complete all as specified and as directed. 3 All as per item No. 2.00 here-in-before butpoint wiring for one 5Amps socket outlet point on independent boardcontrolled by one single pole, one way switch complete all as specified and as directed. 4 All as per item No. 2.00 here-in-before butpoint wiring for one 5Amps socket outlet point on d same boardcontrolled by one single pole, one way switch complete all as specified and as directed. 5 All as per item No. 2.00 here-in-before butpoint wiring for one bell point controlled by one single pole, one way bell push complete all as specified and as directed. 6 All as per item No. 2.00 here-in-before but point wiring using 2.5 sqmm as main wire & 1.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent boardcontrolled by one single pole, one way switch complete all as specified and as directed. 7 All as per item No. 2here-in-before but point wiring using 4sqmm as main wire & 4Sqmm as continous earth wire, for one 15Amps socket outlet point on independent boardcontrolled by one single pole, one way switch complete all as specified and as directed. 8 Material and Labour for Point wiring PVC insulated unsheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm (nominal area) in the existing conduit medium grade including fittings and accessories, one run of continuoussingle core copper cable of1.5 Sq. mm connecting to common earth dolly, using the existing pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting of switches sockets fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified and as directed.Note :- The quoted rates includes the cutting chasis for conduit and sunken boxes. 9 All as per item No. 8.00 here-in-before butpoint wiring for one 5Amps socket outlet point on independent boardcontrolled by one single pole, one way switch complete all as specified and as directed. 10 All as per item No. 8.00 here-in-before butpoint wiring for one 5Amps socket outlet point on d same boardcontrolled by one single pole, one way switch complete all as specified and as directed. 11 All as per item No. 8.00 here-in-before butpoint wiring for one bell point controlled by one single pole, one way bell pushcomplete all as specified and as directed. 12 All as per item No. 8.00 here-in-before but point wiring using 2.5 sqmm as main wire & 2.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent boardcontrolled by one single pole, one way switch complete all as specified and as directed. 13 All as per item No. 8.00 here-in-before but point wiring using 4sqmm as main wire & 4 Sqmm as continous earth wire, for one 15 Amps socket outlet point on independent boardcontrolled by one single pole, one way switch complete all as specified and as directed. 14 Supply and fix in repair switch piano, flush type, single pole, one way, 5 Amp, 230volts complete all as specified and as directed. 15 Supply and fix in repair switch Bell push, flush type, single pole, one way,, 230volts complete all as specified and as directed. 16 Supply and fix in repair switch piano, flush type, single pole, one way, 15 Amp 230volts complete all as specified and as directed. 17 Supply and fix in repair socket outlet multipurpose 3 pin, 5 Amp and 2 pin 5 Amp, flush type, complete all as specified and as directed. 18 Supply and fix in repaiSocket outlet multipurpose 3 pin 5 Amp & 15 Amp, flush type, complete all as specified and as directed. 19 Supply and fix in repair ceiling rose, three terminals, PVC/ isolated body, complete all as specified and as directed. 20 Supply and fix in repair Call bell, electric Ding - Dong type (Domestic pattern), 230 volt, single pole, complete all as specified and as directed. 21 Supply and fix in repair Fan regulator electronic, socket type, suitable for 1200mm /1400mm sweep ceiling fan, fixed in repairs, with and including provision of PVC flexible cable of size 1.00 sqmm copper conductor as required, complete all as specified and as directed. 22 Supply and fixing in repair LED Decorative box type batten 1x20Wprewired upto connection block and connecting with three core PVC copper flexible cable of size 1. Sq. mm complete all as specified and directed by Engineer-in-Charge. Make-AS PER APPENDIX B 23 Supply and fixing in repair LED Decorative box type batten 1x9Wprewired upto connection block and connecting with three core PVC copper flexible cable of size 1.00 Sq. mm complete all as specified and as directed. 24 Supply and fixing in repair LED tube rod 20 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x18W to 22W, complete all as specified and directed. 25 Supply and fixing in repairLEDluminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type which provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid ceiling complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.Make-Havells or its equilant in Crompton/Wipro 26 S&F in repair LED 10 watts IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution garden light fitting with robust design and efficient light distribution including light fitting fixing and making PCC block foundationand connecting the fittinngs on PCC foundation blockincluding taking out old complete all as specified and directed. Make -Crompton LBLSN-10-CDL or its equivalent in Havells /Wipro. 27 Supply and fix in repair LED 30 W,IP65,Aluminium body,3000lm,input voltage 140-270v,cri>80 suitable as building security light complete all as specified and as directed. 28 Supply and fixing in repair decorative indirect post top for garden & landscape lighting of 40 watts with IP 65 protection. Resistant to impact and corrosion. Anti Glare and uniform distribution complete all as specified and as directed. 29 Supply and fix in repair sheet metal enclosure single pole and neutral with a two pin socket and earth plug complete with one MCB single pole and 240V, 20 Amp ‘B’ curve, 10 kA,old unserviceable complete all as specified and directed . 30 Supply and fix in repair Sheet metal enclosure (DB) single phase & neutral, double door 4 way, 240 volt with 200 Amps rated bus bar & IP 54 protection, including taking out old unserviceable complete all as specified and directed. 31 All as per item No.30.00 here-in-before butDB 8 way complete all as specified and as directed. 32 Supply and fix in repair Sheet metal distribution board TPN, with double door,4 way, 415 volt with 200 Amps rated bus bar & IP 54 protection, complete all as specified and as directed. 33 All as per item No.32 here-in-before butDB 8 way complete all as specified and as directed. 34 Supply and fixing Load line TPN vertical distribution board 8 Way double door dust protected powder coated inclusive of busbar, neutral link, blanking plates and having provision of MCCB 4 Pole 100 to 120 Amps as incomer and MCBs SP/TP as outgoing as per IS - 01 No,having IP-43 protection, complete all as specified and as directed. 35 Supply and fixing Load line TPN vertical distribution board 4 Way double door dust protected powder coated inclusive of busbar, neutral link, blanking plates and having provision of MCCB 4 Pole 100 to 120 Amps as incomer and MCBs SP/TP as outgoing as per IS - 01 No,having IP-43 protection, complete all as specified and directed. 36 Supply & Fixing in repairs MCCB, 4-pole, breaking capacity 16 KA, 415 volts, 125 Amps including taking down unservicable onecomplete all as specified and as directed. 37 Supply & Fixing in repairs TPN 100A Breaking capacity 10 KA, 415 volts,including taking down unservicable one complete all as specified and as directed. 38 Supply & Fixing in repair MCCB, 4-pole, breaking capacity 16 KA, 415 volts, 63 Amps complete all as specified and as directed. 39 Supply and fix in repairTPN 63A , breaking capacity 10 KA, B curve, fixed in repairs, complete all as specified and as directed. 40 Supply and fix in repair MCB 40 Amp, 415 Volt, TP, breaking capacity 10 KA, B curve, fixed in repairs, complete all as specified and as directed. 41 Supply and fix in repair MCB 32/ 40 Amp, 230 Volt, SPN, breaking capacity 10 KA, B curve, fixed in repairs, complete all as specified and as directed. 42 Supply and fix in repair MCB 6 to 40 Amp, 230 Volt, SP, breaking capacity 10 KA, B curve, fixed in repairs, complete all as specified and as directed. 43 Material and labour for Sub Main Wiring (in replacement) with two single core 2.5 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including one run of continuous multi stranded copper conductor 2.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 2.5 Sqmm main cable + one run of 2.5 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre. 44 Material and labour for Sub Main Wiring (in replacement) with two single core 4 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including one run of continuous multi stranded copper conductor 4 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 4 Sqmm main cable + one run of 4 Sqmm cable for earth continuity and PVCconduit shall be measured as one unit/one Running Metre. 45 Material and labour for Sub Main Wiring (in replacement) with two single core 6 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including one run of continuous multi stranded copper conductor 6 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 6 Sqmm main cable + one run of 6 Sqmm cable for earth continuity and PVCconduit shall be measured as one unit/one Running Metre. Notes:Taking down will be from different location and wiring will be done on location to bring electric meter outside the houses and as specified by engineer in charge. 46 Taking up / downwater heater (Geyser) of capacity 50/35/25 ltrs operating on 230 volts AC electric supply, in any position and of any make, after disconnecting all electric connection and hot and cold water connection,and including transportation to the contractor sworkshop for repair and vice - versa, , and painting / numbering ( if necessary) and vice - versa after repairing, general cleaning/ overhauling, cleaning and discaling the tank and assembly with suitable detergent and making fully serviceable and fixing back in same location / position or new location complete all as specified and as directed.Note :- (a) Repairing of any parts except the work mentioned in item will be measured and paid seperately under supply only items.(b) Replacement of any un serviceable parts required for making thegeyser serviceable will be measured and paid seperatelly undersupply onlyNo extra payment will be allowed for replacing these items, as the same isdeemed to be included in relevant item 47 Supply only Stainless steel inner tank suitable for 25 ltrs Geyser of any make / shape /holes for fixing geyser assembly complete all as specified and as directed. 48 All as per item No 47 herein before but for 35 ltrs complete all as specified and as directed. 49 All as per item No 47herein before but for 50 ltrs complete all as specified and as directed. 50 Supply only bottom base assembly of copper 9/8/7/6 holes type suitable for 35/25 ltrs capacity geyser complete all as specified and as directed. 51 All as per item No 50.00 here-in- before but for 50 ltrs capacity geyser complete all as specified and as directed. 52 Supply heating element 2000 watts capacity of any shape /type with rubber gasket complete all as specified and as directed. 53 Supply Thermostat suitable to adjust the temperature from0º C to 80º C complete all as specified and as directed. 54 Supply only glass wool ofgood quality as approved by Engr-in-Charge complete all as specified and as directed. 55 Supply only neon indicator lamp of any shape / size / colour complete all as specified and as directed. 56 Supply only PVC insulated, sheathed 3 core flexible cable of size2.5Sqmm complete all as specified and as directed. 57 Supply only Safety plug any type complete all as specified and as directed. 58 Supply & fixing non return valve 15mm bore cast copper alloy suitable for geyser complete all as specified and as directed 59 Supply only Rubber gasket of thickness 5 mm for geyser assembly of08 holes / 09 holes complete all as specified and as directed. 60 Supply onlybottom inspection cover plate in two pieces with suitable openings for indicator lamps, power cable entry with rubber washer etc, gauge of plate not less than 18 SWG for 25/35/50 Ltrs capacity geysers of any make/ shape complete all as specified and as directed. 61 Supply and fixing 16A ,30mA,PRCDpower plug,220 V to provide safety against electric shocks with built in test and reset button complete all as specified and as directed.. Make-Havells or equivalent. 62 Supply only GI nut bolts and washers (not exceeding the size 150 mm x 12mm) of existing size of geyser spare parts complete all as specified and as directed. 63 Supply only outer MS shell complete including top and bottom suitable for 25 Ltrs capacity geyser of any make, shape & size as per existing but gauge of sheet not less than 22 SWG complete all as specified and as directed. 64 Supply and fixing PVC connection 15mm bore 450mm longin any position with both end brass nut with inner thereading and washer suitable for cold water connection complete all as specified and as directed. 65 Supply and fixing CP connection 15mm bore 450mm longin any position with both end brass nut with inner thereading and washer suitable for cold water connection complete all as specified and as directed. 66 M/L for spray painting of geyser outer body of any make / size by applying one coat of synthetic enamel white paint over the existing paintincluding cleaning and preparation of surface, complete all as specified and as directed. 67 Disconnecting & taking down complete ceiling fan with blade of any make 1200 mm / 1400 mm sweep from fan hook/ fan box, transporting to local workshop , opening, cutting and taking out complete copper winding , cleaning with kerosene oil /diesel/ terpin oil and dried out, rewindingwith new super enamelled copper wire of suitable size and gauge and number of turns as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff/strip type) replacing u/s providing paper insulation (cuff / strip type) replacing u/s / missing spare (bush, bearing, capacity shackle insulator, canopy, nuts , bolts, earthing, screw, upper, socket, CI block , quarter /split pin (top & bottom) , lock nut etc) fixing the stator in rotor properly aligned and resembling ensuring right DOR, speedy and noiseless running and connecting cable and depositing in E/M yard complete all as specified and as directed.Note:Bush, bearing, capacitor, with nuts, bolts and sockets shall be measured and paid for separately as supply only. 68 Supply only capacitor 2.50 MFD, 440 Volt AC, 50 Hz plastic body powder filled type complete all as specified and as directed. 69 Supply only capacitor 3.15 MFD, 440 Volt AC, 50 Hz plastic body powder filled type complete all as specified and as directed. 70 Supply only MS fan clamps with rubber real including nuts and bolts, split pin suitable for ceiling fan 1200 / 1400 mm sweep complete all as specified and as directed. 71 Supply only bearing suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and as directed. 72 Supply only bush suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed. 73 Supply only PVC insulated flexible 3 core, 1sqmm size copper conductor cable of size ncluding taking out the old unserviceable PVC flexible wire complete all as specified and as directed. 74 Supply & fixing for Mild Steel Down Rod of suitable dia , 45 Cms longwhite orcoloured, compatible to existing ceiling fans of 1200mm or 1400 mm sweepincluding taking out old unserviceable down rod from the fan complete all as specified and as directed. 75 Disconnecting and taking down ceiling fan of anysweepfor carrying out overhauling such as cleaning ,oiling, lubricating, greasing etc and replacement of minor parts such aswasher, split pins/ blade screw etc and defective parts, if any, and refixing the ceiling fan fan on same location and connecting it properly and testing for noiseless running to the entire satisfaction ofEngineer-in-charge complete all as specified and as directed.Note : (i). Defective parts required to be replaced shall be measured and paid for separately as supply only.(ii).Cost of the minor parts i.e.washer, split pins/ blade screw etc deemed to be included in unit rate & nothing shall be paid on this account. 76 Spray painting of ceiling fan 1200/1400 mm sweep and testing at site full load with super enamelled heat resistant synthetic white paint duly filling the cavities with filler complete all as specified and as directed. 77 Disconnecting & taking down (burnt) exhaust fan of any make 300mm sweep transporting to local workshop, opening, cutting and taking out complete copper winding , cleaning with kerosene oil / diesel/ terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff /strip type) replacing u/s / missing spare (bush, bearing , capacity etc) fixing the stator in rotor properly aligned and reassembling ensuring right DOR , speedy and noiseless running and depositing in E/M yard complete all as specified and as directed.Note: Bush bearing capacitor shall be measured and paid for separately. 78 All as per serial item No. 77 here-in-before but exhaust fan 450 mm sweep complete all as specified and as directed. 79 Taking down oldand Supply and fix in repaircapacitor 4 MFD, 440 Volt AC, 50 Hz plastic body powder filled type for exhaust fan of 300/400mm sweep complete all as specified and as directed. 80 Supply only bearing suitable for 300 / 400/ 450 mm sweep Exhaust fan complete all as specified and as directed. 81 Spray painting ofExhaust fan and testing at site full load with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape complete all as specified and as directed. (Bush, bearing, capacitor, canopy, shackle insulator with nuts, bolts and sockets will be measured and paid separately). 82 Collecting unserviceable (burnt) table / cabin fan of any make and sweep up to 450 mm from Internal Elect Section, transporting to local workshop, opening, cutting and taking out complete copper winding, cleaning with kerosene oil / diesel / terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufacturers, varnishing and heating the winding including providing paper insulation (cuff / strip type), replacing unserviceable / missing spares (bush, bearing, capacitor etc), fixing the stator in rotor properly aligned and reassembling ensuring right DOR, speedy and noiseless running complete all as specified and as directed. 83 Supply and fixing in repair LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. 84 Supply only self adhesive PVC electrical insulation tape electrical insulated tap role of size 1.8 cm x 6.5 m x 0.125 mm complete all as specified and directed. 85 Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, earth lead GI wire 4 mm dia by means of bolts, nuts, check-nuts and washers of galvanized iron and of earth wire protected by galvanizediron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregatein lieu of CI cover and frame etc allas specified and shown in electrical plate No. 3 of SSR-2009 (Part-I), testing on completion, complete including dismantling of existing earthing complete all as specified and as directed.Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:3:6) type C-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.(iv)Earth resistance should be less than 1 Ohm. In case the test results are not found below 1 Ohm, complete earthing will be redone without any extra cost to Govt. 86 Supply only self adhesive PVC electrical insulation tape electrical insulated tap role of size 1.8 cm x 6.5 m x 0.125 mm complete all as specified and directed. 87 Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, earth lead GI wire 4 mm dia by means of bolts, nuts, check-nuts and washers of galvanized iron and of earth wire protected by galvanizediron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregatein lieu of CI cover and frame etc allas specified and shown in electrical plate No. 3 of SSR-2009 (Part-I), testing on completion, complete including dismantling of existing earthing all as specified and directed.Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:3:6) type C-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. 88 Note: The total amount shall subject to adjustment of credit of Rs 33842.00 for old Materials as per Schedule of Credit

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 10 Lakhs /-
Disclaimer :