Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-06-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-06-2024 |
| Sl. No. | Item Description |
| 1 | DESCRIPTION OF ITEMS |
| 2 | Checking of fault in Electric wiring of New accn area by deputing adequate number of qualified electrician and helper with necessary T&P and safety tools etc and ensure that to restore electricity after rectifying the fault with using minor items of cost not more than Rs. 10/- shall be included in the unit rate complete all as specified (complaint shall be part of the bill),replacement of electrical accessories, if reqd are measured and paid separetely in relevant items:Note:- (a) The electrical items reqd to repair fault are measured and paid separetely in relevant items.(b)The fault shall be attended within one day, otherwise recovery will be charged Rs. 50/- per complaints per day. (c) Electrician will take the complaint slip from JE EM and the same will be depositing to JE EM duly signed by Users after completing the job for making payments. |
| 3 | Checking of fault in Solar water Heater of New accn area by deputing adequate number of qualified Solar technician/Plumber and helper with necessary T&P and safety tools etc and ensure that to restore water heater in working condition after rectifying the fault with using minor items of cost not more than Rs. 10/- shall be included in the unit rate complete all as specified (complaint shall be part of the bill),replacement of connected accessories if reqd are measured and paid separetely in relevant items:Note:- (a) The Solar water heater items reqd to repair fault are measured and paid separetely in relevant items. (b)The fault shall be attended within one day, otherwise recovery will be charged Rs. 50/- per complaints per day. (c) Solar technician/Plumberwill take the complaint slip from JE EM and the same will be depositing to JE EM duly signed by Users after completing the job for making payments. |
| 4 | Supply only Flat plate collector of rectangular type as per exixting at site |
| 5 | Supply only Hot water tank SS 304 ex model cap100 Ltr with heat exchanger |
| 6 | Supply only Hot water tank SS 304 ex model cap 200 Ltr with heat exchanger |
| 7 | Supply only Hose pipe including clamp as per existing at site 2 KW |
| 8 | Supply only Heating element 2 KW,ISI Marked |
| 9 | Supply onlyHeating element 3 KW,ISI Marked |
| 10 | Supply only Thermostat for solar water heater 100/200 Ltr ,ISI Marked |
| 11 | Supply only EIS-DA (descaling chemical for all type metal) as complete |
| 12 | Supply only Toughened Glass forsolar plate of solar water heater of capacity 100/200 Ltr |
| 13 | Supply only Makeup tank for solar water heater 100/200 Ltr |
| 14 | Supply only NRV of makeup tank for solar water heater 100/200 Ltr |
| 15 | Supply only Elbow 15mm GI, ISI Marked. |
| 16 | Supply only Elbow 20mm GI, ISI Marked. |
| 17 | Supply only Elbow 25mmGI, ISI Marked. |
| 18 | Supply only Tee 15mmGI, ISI Marked. |
| 19 | Supply only Tee 20mmGI, ISI Marked. |
| 20 | Supply only Tee 25mmGI, ISI Marked. |
| 21 | Supply only Socket 15 mmGI, ISI Marked. |
| 22 | Supply only Socket 20 mmGI, ISI Marked. |
| 23 | Supply only Socket 25 mmGI, ISI Marked. |
| 24 | Supply only Union 15mmGI, ISI Marked. |
| 25 | Supply only Union 20mmGI, ISI Marked. |
| 26 | Supply only Union 25mmGI, ISI Marked. |
| 27 | Supply only Reducer elbow 20mmGI, ISI Marked. |
| 28 | Supply only Reducer elbow 25mmGI, ISI Marked. |
| 29 | Supply only Reducer Tee 20mmGI, ISI Marked. |
| 30 | Supply only Reducer Tee 25mmGI, ISI Marked. |
| 31 | Supply only Reducer Socket 20 mmGI, ISI Marked. |
| 32 | Supply only Reducer Socket 25 mmGI,ISI Marked. |
| 33 | Supply only Hex nipple 15 mmGI, ISI Marked. |
| 34 | Supply only Hex nipple 20 mmGI, ISI Marked. |
| 35 | Supply only Hex nipple 25 mmGI, ISI Marked. |
| 36 | Supply only Tank nipple 15 mmGI, ISI Marked. |
| 37 | Supply only Tank nipple 20 mmGI, ISI Marked. |
| 38 | Supply only Tank nipple 25 mmGI, ISI Marked. |
| 39 | Supply only Plug 15mm GI, ISI Marked. |
| 40 | Supply only Plug 20mm GI, ISI Marked. |
| 41 | Supply only Plug 25mm GI, ISI Marked. |
| 42 | Supply only Nipple 15 mm GI, ISI Marked. |
| 43 | Supply only Nipple 20 mm GI, ISI Marked. |
| 44 | Supply only Nipple 25 mm GI,ISI Marked. |
| 45 | Supply only Ball valve 15mm GI, ISI Marked. |
| 46 | Supply only Ball valve 20mm GI, ISI Marked. |
| 47 | Supply only Ball valve 25mm GI, ISI Marked. |
| 48 | Supply only Gate valve 20 mm, ISI marked all as speficied and directed |
| 49 | Supply onlyGate valve grade 25 mm, ISI marked all as speficied and directed |
| 50 | Supply only GI pipe medium grade 25 mm, ISI marked wrapping of glass wool insulation incl aluminium cladding of 1 mm thickness complete all as speficied and directed. |
| 51 | Supply only GI pipe medium grade 15 mm, ISI marked wrapping of glass wool insulation incl aluminium cladding of 1 mm thickness complete all as speficied and directed. |
| 52 | Supply only GI pipe medium grade 20 mm, ISI marked wrapping of glass wool insulation incl aluminium cladding of 1 mm thicknessall as speficied and directed. |
| 53 | Supply only flexible hose pipe 20 mmas per sample |
| 54 | Supply only clamps as per sample |
| 55 | Supply only gasket as per sample |
| 56 | Supply only of M-Seal |
| 57 | Supply only float valve 20 mm |
| 58 | Supply only Tank lid 200 ltrs |
| 59 | Supply only Tank lid 500 ltrs |
| 60 | M&L for opening of solar plate & repairing of leakage copper pipe with complete gas welding/soldering as required on complete copper tubing in solar water heater and after completion of jobreassembling the same complete all as specified and directed. |
| 61 | Dismantling exisiting solar water heater 100/200Ltr and descaling the pipe by means of descaling agentthe same reassembling aftercomletion the work Note : Descaling agent shall be paid and measured separetely |
| 62 | M&L for painting of solar water heater of old MS stand with monkey cage of tank duly painted of one coat of Black enemaled paint complete all as specified and directed. |
| 63 | Cleaning of overhead tank 200 Ltr by cleaning brush complete draining of old water and checking no float valve broken or no leakage found after cleaning of OH tank |
| 64 | S&F in replacement ofRotational moulded polyethylene water storage three layers tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 200 Ltrs all as specified and directed by Engr-in-Charge |
| 65 | M&L for opening ofMS stand/cage of services tank weldingof stand with replacement of hinge at required position complete all as specified and directed. |
| 66 | Dismantling of existing solar water heater 100/200 Ltrandwelding /brazing of leakage tank at any position complete all as specified and directed. |
| 67 | Taking down carefully storage water heater of capacity25 to 50 ltr, dismantling inner tank & outer tank, pipe assembly, cleaning thoroughly with descaling liquid compound, overhauling complete to ensure free & consistent flow of water through pipe outlet, bronze welding of inner tank if required at site, rethreading of inlet/outlet pipe 15mm dia, reassembling the same at existing/new place, testing/commissioning after re-installation at sitecomplete all as specified & directed. Note:-The defective parts shell be measuredand paid in relevant items saperatively. |
| 68 | M&L forpainting on external surface with one coat of white synthetic enamel paint after filling cavities with filler, incl writing MES No in front side of outer surface of geyser in sign writing with black colour to storage water heater (Geyser) complete all as specified and directed. |
| 69 | Supply only the following parts for geysers 50/25/35 Ltrs capacity of make Bajaj / Racold / Power pack/ Venus or equivalent ISI marked (Make of parts shall be as per make of Geysers) :- |
| 70 | Supply only Heating element 2 KW suitable for operation on 230V AC 50Hz |
| 71 | Supply only Heating element 1.5KW suitable for operation on 230V AC 50Hz |
| 72 | Supply only Thermostatfitting fitment varying capactiy for 25/35/50 Ltrs capacity Geyser. |
| 73 | Welding / brazing of copper tank for arresting leakages etc for 25/35/50 Ltrs capacity geysers |
| 74 | Supply only release valve |
| 75 | Supply only PVC connection hot and cold type of 15 mm size with brass nut coppling in both end of length 300 mm for geyser |
| 76 | Supply only PVC connection hot and cold type of 15 mm size with brass nut coppling in both end of length 450 mm for geyser |
| 77 | Supply only new appratus plate complete with nuts, bolts, washers, rubber gasket so as to make it leak proof complete 25/35 ltrcapacity and all as specified and directed. |
| 78 | Supply only new appratus plate complete with nuts, bolts, washers, rubber gasket so as to make it leak proof complete 50 ltrcapacity and all as specified and directed. |
| 79 | Supply only insulating material of glass wool for storage type water heater (geyser)any make and size 25 to 50 ltr capacity complete all as specified and directed. |
| 80 | Supply only neon lamp indicator square/round type for storage type water heater of any capacity complete all as specified and directed. |
| 81 | Supply only rubber gasket of appratus plate assy of storage water heater and S&F new rubber gasket suitable for 25/35/50 ltrs capacity storage water heater, complete all as specified and directed. |
| 82 | S&F in repair stop cock 15mm dia chromium plated screwed down screwed for iron pipe or for brass ferrule all as specified. |
| 83 | S&F in replacement industrial plug top, 3 pin (2 pin & earth) suitable for sheet metal plug & socket 16/20 Amps, 240 volts complete all as specified and directed. |
| 84 | S&F in repairsocket 3 pin industrial type 3 pin (2 pin & earth) suitable for sheet metal plug & socket 16/20 Amps, 240 volts complete all as specified and directed. |
| 85 | Taking down existing unserviceable MCB single pole of any capacity from sheet metal enclosure and S&F new MCB single pole, 6-32 Amp, complete all as specified and directed. |
| 86 | M & LFlushing the complete condensing unit of AC refrigirator and dep freezer, evaportar jointing and the compressor suction and delivery and search out leakage and rectify by means of breazing. and delivery tubes and replacement the charging lines.Strainers capillary tube etc rectification of the leakage from the system vaccumising dehydrating oilincluding testing and commissioning of system complete all as specified and directed. |
| 87 | S&F in repairof condensing unit and housing the unit of any make of the window type AC. |
| 88 | Supply & charging refrigerant gas R-134(a) suitable for envirement friendly charging line on sealed unit of compressor ofwindow type room AC 1.5/2.0 ton including crimping and resoldring to charging line, complete all as specified and directed. |
| 89 | Removing the unserviceable compressor unit from the window/splittype room AC 1.5 ton and supply and fix new hermetically sealed compressor unit, Make : Kirloskar/Shriram suitable to operate in AC single phase 50 HZ 230 Volts suitable for window type AC 1.5 ton and all as specified and all as directed by Engineer-in-Charge. |
| 90 | Removing the unserviceable compressor unit from the window/splittype room AC 2.0 ton and supply and fix new hermetically sealed compressor unit, Make : Kirloskar/Shriram suitable to operate in AC single phase 50 HZ 230 Volts suitable for window type AC 2.0 tonand all as specified and all as directed by Engineer-in-Charge. |
| 91 | Supply and fix repair PCB for the 1.5to 2.0 ton capacity A/C of any make . |
| 92 | Supply and fix repair Evaporator coil for the 1.5to 2.0 ton capacity A/C of any make . |
| 93 | Supply and fix repair Front grill for the 1.5to 2.0 ton capacity A/C conditioners of any make of AC. |
| 94 | Supply and fix repair Starting relay for the 1.5to 2.0 ton capacity A/C conditioners of any make and any type of AC. |
| 95 | Supply and fixrepair Starting capacitor 80-100 mfd for the 1.5to 2.0 ton capacity A/C conditioners of any make of AC. |
| 96 | Supply and fix Running capacitor 36 mfd for the 1.5to 2.0 ton capacity A/C conditioners of any make of AC. |
| 97 | Supply only Compressor mounting rubber bush(set of 3 Nos counted as one unit) |
| 98 | S&F repair blower fan motor for split unit AC 1.5 ton to 2.0 ton (As per sample) incl taking down fan motor complete all as specified. |
| 99 | S&F repair condenser Fan blade rings 1.5 to 2.0 ton (As per sample) incl taking down old blower complete all as specified. |
| 100 | Taking down unserviceable copper tube from window type AC1.5 ton to 2.0 ton supply & joint new copper tubefor charging refrigerant gas in machine complete all as specified and directed. |
| 101 | S&F repair thermostat unit including electronic relay eqpt and electronic plate for air conditionerincl taking down old thermostat complete all as specified and directed. |
| 102 | Disconnecting of unserviceable three core flexible cord from window type AC/Refrigerator/storage water heater / voltage stabilizers of any size, supply and S & F connect three core flexible cored of size 2.5 sq complete all as specified and directed. |
| 103 | Cutting suction and discharge gas pipe line and taking out unsv compressor unit from refrigerator of165/180 ltrs capacity and S&F new sealed compressor unit of same model or approved model of same capacity complete incl commissioning and testing after installation at site complete all as specified and directed. |
| 104 | ditto all as item No. 102 abovebut refrigerator of capacity 210/310/320 ltrs |
| 105 | S&F in repair of cooling coil and housing of the refrigirater unit of any make.( 280 ltr to 310 ltr) |
| 106 | S&F relay for refrigerator including taking down old relay complete all as specified. |
| 107 | S&F thermostat unit for refrigerator including taking down old thermostat complete all as specified. |
| 108 | S&F pigmy lamp pin/thread type 15 watts 230 volts suitable for refrigerator incl removing old bulb/lamp, complete all as specified and directed. |
| 109 | S&F door gasket for refrigerator (as per sample) incl taking down old door gasket & aligning door after opening from body incl inserting packing, welding, threading etc which so ever required to leave no air gap between door & body and top edge of refrigerator flushing with top surface of refrigerator of capacity 165/175 ltrs. |
| 110 | ditto all as item No. 108 above but for refrigerator of capacity 280/286/310 or 320 ltrs capacity. |
| 111 | Taking out unserviceable lock from the refrigerator and S&F new lock with keys, complete all as specified and directed. |
| 112 | Dismantling unserviceble freezer defrosting fan from double door refrigerator and replaced with new freezer defrosting fan of same model/capacity 200 to 300ltr ,complete all as specified and directed. |
| 113 | M & L for replacement ofunserviceble/damagefreezer cooling coil assembly complete of existing model of refrigerator 165/175 ltrs capacity all as directed. |
| 114 | ditto all as item No 112 above but refrigerator of 280/310/320 ltrs |
| 115 | Taking down unserviceable copper tube from any capacity ofRefrigerator, supply & joint new copper tubefor charging refrigerant gas in machine complete all as specified and directed. |
| 116 | Supply & charging refrigerant gas R-134(a) charging line on sealed unit of compressor of refrigerator 165/175 LTRS16including crimping and resoldring to charging line, complete all as specified and directed. |
| 117 | ditto all as per item No. 115 above but280/310/320 ltrsR-134(a) non CFC refrigerant gas complete all as specified and directed |
| 118 | Taking down unserviceable capillary from anycapacity ofRefrigerator, supply & joint new capillary for charging refrigerant gas in machine complete all as specified and directed. |
| 119 | Taking down old unserviceable liquid filter/drier fromallcapacity ofRefrigerator, Supply & joint new liquid filter/drier for charging refrigerant gas in machine complete all as specified and directed. |
| 120 | Taking down burnt finned strip heater from winter heating plant of MH & S&F new finned strip heater of capacity 3.0 KW complete all as specified. |
| 121 | ditto All as per item No. 119 above but 2.0 KW. |
| 122 | Disconnecting, dismantling winter heating plant of capacity 38 KW (AHU capacity 4600 CFM) installed in OT/ICU of 161 MH for complete overhauling/servicing and refitting in same position after reassembling including replacement of minor repairsComplete all as specified and directed by Engineer-in- Charge |
| 123 | ditto all as per item No. 121 above but winter heating plant of 10KW (AHU capacity 1400 CFM) installed in labor room of family ward, complete all as specified and directed byEngineer-in-Charge |
| 124 | Taking out worn out ‘V’ shape fan belt from blower assembly of winter heating plant of OT & labour room and S&F new fan belt of same size, complete all as specified and directed. |
| 125 | Taking down unserviceable heating elementof any capacity from winter heating plant and replacing the same with new heating rod including commissioning and testing complete all as specified and directed. |
| 126 | S&F in repairs and connect 3 Phase contactor 32 Amp 415 V with 230 V coil complete all as specified and directed. |
| 127 | S&F in repairs and connect 3 Phase contactor 40 Amp 415 V with 230 V coil complete all as specified and directed. |
| 128 | S&F in repairs and connect 3 Phase contactor 63 Amp 415 V with 230 V coil complete all as specified and directed. |
| 129 | Taking out existing unserviceablevoltmeter from winter heating plant control board and S&F new volt meter0-500 voltsof size 96mm x96mmincluding connecting and testing complete all as specified and directed. |
| 130 | Taking down unserviceable ball bearing from blower fan assembly of winter heating plant of 10KW & S&F new ball bearing of existing size complete all as specified and directed. |
| 131 | S & F in repair ball bearing of blowr fan in existing winter heating plant of capacity 38 W all as specified and directed. |
| 132 | Repair of EPUofshadow less light fitting, checking & replacing defective parts in electronic printed circuit board, checking & repairing of auto control circuit complete including& testing & replacement of burnt damaged relay etc complete all as directed. |
| 133 | S&F in repair voltage stabilizer with input voltage 110 volts to 290 volts and output 230 voltage with 50 Hz,of capacity 4 KVA suitable for refrigerator / AC incl taking down old voltage stabilizer complete all as specified. |
| 134 | Repair of voltage stabilizer 0.5 /1.0 KVA automatic boost & buck type, checking & replacing burnt parts in electronic printed circuit board, checking & repairing of auto control circuit complete including calibration & testing & replacement of burnt damaged relay etc complete all as directed. |
| 135 | Repair of voltage stabilizer 3.0/4.0KVA automatic boost & buck type, checking & replacing burnt parts in electronic printed circuit board, checking & repairing of auto control circuit complete including calibration & testing & replacement of burnt damaged relay etc complete all as directed. |
| 136 | Repair tovoltage stabilizer5.0 KVAby replacing worn out / burnt parts in electronic printed circuit, board, checking and repairing of automatic control circuit, replacement of damaged / burnt relay/transformer etc & calibrating the same complete all as specified and directed. |
| 137 | S&F time delay relay for voltage stabilizer5 KVA (As per sample)including taking down old defective relay all as directed. |
| 138 | S&F time delay relay for voltage stabilizer 3 KVA/ 4 KVA (As per sample)including taking down old defective relay all as directed. |
| 139 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA complete all as specified and directed. Note: Old US Appliances will be deposited to AGE EM Store yard |
| 140 | Disconnecting / taking down carefully ceiling fan from existing position, dismantling, overhauling & cleaning thoroughly, oiling greasing and rehanging after replacing, split pins, check nuts, rubber reel etc and reassembling duly connected with new PVC 3 core flexible copper conductor cableof size 23/.0076 complete testing & specified all as directed. |
| 141 | Disconnecting / taking down carefully exhaust fan from existing position, dismantling, overhauling & cleaning thoroughly, oiling greasing and rehanging after replacing, split pins, check nuts, rubber reel etc and reassembling duly connected with new PVC 3 core flexible copper conductor cableof exhaust fan 450 mm sweep complete all as directed. |
| 142 | Ditto all as per item No. 140 above but exhaust fan 380/300 mm sweep |
| 143 | Ditto all as per item No. 140 above but exhaust fan 250/225 mm sweep |
| 144 | Rewinding of ceiling/exhaust/wall mounted/cabin/table fan with super enameled copper winding wire of suitable size and providing with suitable insulation to fan including replacement of wornout nut, bolt, washers, split pin etc., re assembling and testing on completion complete all as specified and directed for the following type of fans. |
| 145 | Ditto all as per item No143 Exhaust fan of any Make 300/250 mm sweep |
| 146 | Ditto all as per item No 143 Exhaust fan of any Make 450/380 mm sweep |
| 147 | Ditto all as per item No 143 Cabin fan/wall fan/table fan/pedestal fan 400 mm sweep. |
| 148 | Supply onlyfollowing components of fan in replacement of unserviceable item as per item no-140 & 143all as directed by Engineer-in-Charge |
| 149 | Supply only Ball bearing of suitable size for Exhaust fan of any size and sweep. |
| 150 | Supply only capacitor 2.5mfd , ± 5%, 440V, AC, 50 Hz after removing old/defective condenser complete all as specified an directed. |
| 151 | Supply only MS Clamps with nut bolts and washers for hanging of ceiling fan of any size. |
| 152 | Supply only bush for ceilingfan after taking out old dry/damaged bushcomplete all as specified & directed. |
| 153 | Supply only ball bearing for ceiling fan (As per sample) after removing old damaged ball bearing complete all as specified and directed. |
| 154 | S&F bladein repair assembly suitable for exhaust fan 300 mm sweep including taking down old unserviceable blade assembly from exhaust fan, complete all as specified and directed. |
| 155 | S&F blade in repairassembly suitable for exhaust fan 250/225 mm sweep including taking down old unserviceable blade assembly from exhaust fan, complete all as specified and directed. |
| 156 | S&F blade in repair assembly suitable for exhaust fan 450mm sweep including taking down old unserviceable blade assembly from exhaust fan, complete all as specified and directed. |
| 157 | M&L for painting with one coat ofpaint with grey enameled paint on external surface of exhaust fan of any size, including frame and louvers and writing MES NO. on outersurface of motor with black enamel synthetic paintcomplete all as specified and directed |
| 158 | Material & Labour in repair for sub main wiring with 1100 volts grade PVC insulated and unsheathed cable with stranded copper conductor 2x4 Sqmm, of code Red for Phase,Black For Neutral & Green For Earth concealed in wall and drawn including PVC conduit along with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed. |
| 159 | Material & Labour in repair for sub main wiring with 1100 volts grade PVC insulated and unsheathed cable with stranded copper conductor 2x6 Sqmm, of code Red for Phase,Black For Neutral & Green For Earth concealed in wall and drawn including PVC conduit along with 6 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed. |
| 160 | S&F in repair Electronic fan regulator flush type,switch size Step type, 230 volts ISI marked complete all as specified and directed. |
| 161 | S&F in replacement of LED Bulb 9 watt,6500K complete all as specified and directed. |
| 162 | Ditto as per item 160 but of capacity 12 watt, |
| 163 | Ditto as per item 160 but of capacity 15 watt, |
| 164 | S&F in replacement of LED Bulb 9 watt,4000K complete all as specified and directed. |
| 165 | Ditto as per item 163 but of capacity 12 watt, |
| 166 | Ditto as per item 163 but of capacity 15 watt, |
| 167 | S&Fin replacement of LED Florid Ultra 30 watt,B-22 865 Lamp,6500K complete all as specified and directed. |
| 168 | S&Fin replacement of inverterLED Bulb 9 watt, complete all as specified and directed. |
| 169 | Ditto as per item 167 but of capacity 12 watt, |
| 170 | Ditto as per item 167 but of capacity 15 watt, |
| 171 | Supply and Fix in repair of 1x20 watt LEDsecurity light fitting , pressure die-cast aluminium including fixing the same of GI pipe 25 mm dia bore light grade bracket, 1.5 mtr long including necessary cutting / bending /welding and fixed the same with two Nos FI clamps of 40x 4mm duly painted and suitable size of nut & bolts etc. and making electric connection with two core copper flexible wire of 0.50 Sqmmcomplete and including taking down old fitting all as specified and directed. |
| 172 | S&F in repair round surcacemounting LED panel with luminaire3W, 6500K with aluminum housing plastic diffusercomplete including taking down old fitting all as specified and directed. |
| 173 | S&F in repairround surcacemounting LED panel with luminaire6/8 W, 6500K with aluminum housing plastic diffusercomplete including taking down old fitting all as specified and directed. |
| 174 | Supply and Fixing in repair Decorative wall Light fixture made up of polycarbonate, suitable for retrofit LED 9 W (spiral B-22 Base) complete all as specified and directed. |
| 175 | S&Fin repair recess mounting LED 2x2 luminaire 36W, slim ceiling light with extruded aluminium housing and milky diffuser complete and including taking down old fitting all as specified and directed. |
| 176 | S&Fin repair recess mounting LED 2x2 luminaire 18/24W, slim ceiling light with extruded aluminium housing and milky diffuser complete and including taking down old fitting all as specified and directed. |
| 177 | S&F in repair LED bulk head 5 Watt with PDC aluminium housing and milky diffuser complete and including taking down old fitting all as specified and directed. |
| 178 | Supply and fix in repair of LEDIntegrated Batten T5box type surface mouted, 18/20 W prewired including electric electrical connection with PVC insulated twin twistedcopper wire of size 0.75 Sqmm from ceiling rose to tube light fitting and including taking down old fitting complete all as specified and directed. |
| 179 | Supply and fix in repair of LEDIntegrated Batten T5box type surface mouted, 9/10 W prewired including electric electrical connection with PVC insulated twin twisted copper wire of size 0.75 Sqmm from ceiling rose to tube light fitting and including taking down old fittingcomplete all as specified and directed. |
| 180 | S&F in replacement ofcone round post top lannterns LED fittings suitable for 45 watt LED fittings, prewired with fixing arrangement complete all as specified and directed. |
| 181 | M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 5 of MES schedule 1991 part – I connected to earthing test point including earth continuity conductor and loop earthing etc. as required 4 mm dia galvanized iron or steel wire including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thck in RCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and GI protection pipe light grade 15 mm dia beyond 7.5 mtr from electrode to earth terminal point /main switch board and 20mm bore GI watering pipe medium grade etc. complete all as specified and directed. |
| 182 | M&L in replacement of Vertical type TPN DB, 4 Way, as per IS-8623, IP-42 protection, universal mounting with 100A copper bus bar with neutral bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCCB 125 Amps TPN as incomer and MCB TP as outgoing, with and including providing following MCCB/MCBs & making necessary electrical connection for incoming & outgoing cables, with copper lugs, crimped with crimping tool :-a) Incoming:- MCCB, TPN, 415 Volts,125 Amp ultimate breaking capacity (lcu)-25 KA, confirm to IEC-60947-2-01 No(b) Out going MCBs:- MCB TP 415 volts 63 Amps having repturing capacity 10 kA, \"C\" curve type-4 Nos |
| 183 | Supply and fix in repairSingle pole and neutral enclosure with a two pin and earth plug and socket complete with onesingle pole MCB of 20 ampincluding taking down all as specified and directed. |
| 184 | Supply and Fix in repairMCCB, 4 pole, 415 volts, 100 amps, of 16 KA complete all as specified and directed. |
| 185 | Supply and Fix in repairMCCB, 4 pole, 415 volts, 125 amps, of 16 KA complete all as specified and directed. |
| 186 | Supply and Fix in repairMCCB, 4 pole, 415 volts, 200 amps,of 16 KA complete all as specified and directed. |
| 187 | Supply & fixingin repair of 1100 volts grade heavy duty cable with PVC insulated aluminiuum conductor served with an inner sheating of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspention wire one twin core 10sq mm solid conductor. |
| 188 | Note : Tenderers may note that amount of credit Rs 92,734.90 will be deducted from the total amount arrived, at the time of Acceptance of contract. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy