| 1 | Inspection and rectify the problem of under ground sewageof all nature i.e.blockage of WHB, bottle trap, urinal, sink, floor trap Nahani traps, WC gully trap, vertical CI pipe/PVC pipes of any dia including junction holes of any description ,sewer/rain water line, manholes in any situation of building for cleaningmanually using bamboo or other eqpt / mechanically as per requirement at siteand removing blockage from entire system and making it fully functional in the area of Piru Vihar in the AOR of AGE B/RIII complete all as specified and as directed. It also includes the removal of sludge / night soil produced by daily cleaning beyond MOD land immediately after drying.Note:-(i) Contractor shall arrange suitable mechanical equipmentsincl necessary form work/scaffolding and safety measure complete all as specified and directed. (ii) In addition to above, Contractor shall arrange mechanical rodding with vibrating/ drilling concept i.e trolley mounted sewer cleaning machine once in every month for cleaning entire sewage system and free of any sludge/ blockage.(iii)The above aspect shall be deemed to be included in the quoted rate of this item. |
| 2 | Inspection and rectify the problems of water leakage from taps, WCs, flushing cistern, urinals, wash basins, bottle traps CI trap from ceiling etc and any obstruction to water supplyrequiring plumbing work and carry out minor repairs such like replacement of washers, check nuts, tightening of fittings, adjustment of float valves and syphon fittings of flushing cistern, cleaning of bottle traps etc in the area of Piru Vihar in the AOR of AGE B/RIII all as specified and directed.Note:- In addition of above Contractor shall arrange suitable T&P such as die set (1/2\" to 1\") washers of all size, safeda, thread (soot), M-seal, screws, nails and the like incl necessary form work and scaffolding and safety measures to make it functional and leak proof complete all as specified and directed.The above aspect shall be deemed to be included in the quoted rate of this item. |
| 3 | Inspection and rectifying to water leakage from kitchen, toilet & bath CI/PVC pipes in shaft and balcony ,CI trap from ceiling, connecting U/S pipesetc and any obstruction to water supplyrequiring plumbing work and carry out minor repairsin the area of Piru Vihar in the AOR of AGE B/RIII all as specified and directed.In case of no water problem ,to rectify it, work shall be executed at any floor in shaft of building upto 9th storey,therefore the provision for safety belt has to be made by the contractor himself.The above aspect shall be deemed to be included in the quoted rate of this item. |
| 4 | Inspection and rectifying of carpentary work(wooden/steel/aluminium) iron/aluminium mongery, palmet box, door springs, rolling shutters, venetion blinds etc requiring carpentry work and carrying out minor repairs such like tighting of screws/nails easening of joinery door spring etc in the area of Piru Vihar in the AOR of AGE B/RIII . complete all as specified and directed. Note:-In addition above Contractor shall arrange suitable T&P such as (screws/nails, plugs, grease,putty welding rods & portable welding machine drill machine & bid)etc including necessary form work/scaffolding and safety measureto make it functiona lnclall as specified and directed.The above aspect shall be deemed to be included in the quoted rate of this item. |
| 5 | Inspection and rectifying ofblack smith work to welding work in repairs to steel windows/doors, handles, door springs, iron frame of doors, rolling shutter and other iron misc works ,repair by welding run or spot welding complete as per site requirement in the area of Piru Vihar in the AOR of AGE B/RIIIcomplete all as specified and directed. Note:-(i) Contractor will arrange suitable T&P such asRIKSHAW, welding machine, gloves, welding glass,welding rod etc and any other tools required incl necessaryscaffolding and safety measures complete all as specified and directed.(ii)The above aspect shall be deemed to be included in the quoted rate of this item. |
| 6 | M&L for cleaning of existing sewage line of dia 150mm to 300mm from first manhole to final drop outlet into the septic tank or main trunk line by machenical process (by super saucer machine) or jetting machineby injecting water pressure with cutting tools compressure etc. all as specified and directed including removal of sludge/mud/ silt(liquid or dry) in foul position out side of MOD land including takingout manhole covers, sludge cleaning from manholes and refixing the same in position and making good to disturbed portion if any, complete all as spd & directed. |
| 7 | M&L for cleaning of exsting of sewage manholes of any size any depth bailing out of sludge/mud or silt solid or semi solid materials deposited in manholes with mechanical means / appliances and removal of the same out of MoD land and burrying the entire solid/semi solid material under ground including excavation of suitable pit for it all asspd & directed. |
| 8 | M&L for cleaning of sewage line with super sucker machine with 3000 ltr sludge slurry capacity, with and including sucking in, pumping out of MoD land and carrying staff and appliances which are essential for entire removal process, all as specified and directed by Engr-in-Charge. |
| 9 | Hacking out old broken glass any thickness, size quality or description from wooden/steel frame fixed with wooden beads/metal pinning completeall as specified and directed |
| 10 | S&F 4 mm thick plain sheet glass in square not exc. 0.50 sqm in each pane, fixed with pin headed beads or putty (in metal frames etc) completeall as specified and directed. |
| 11 | S&F 4 mm thick figured sheet glass in square not exc. 0.50 sqm in each pane, fixed with pin headed beads or putty (in metal frames etc) completeall as specified and directed. |
| 12 | S&F in repair stainless steel wire cloth with stainless steel 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with wire staples (for windows and gauzed doors) all as specified and directed |
| 13 | S & F in repairstainless steel pipe of 25 mm dia for curtain rod including fixing with bracket & funnel complete all as specified & directed.Note: Only SS pipe will measured for payment purpose. |
| 14 | S & F in repairbrass spindle forbib tap, pillar tap, stop cock,angle valve of any description etc complete all as specified & directed. |
| 15 | S & F in repair concealedbrass spindle/phase for cocealed stop cock for shower of any description etc complete all as specified & directed. |
| 16 | S & F in repair15 mm dia bib tap cast copper alloychromium plated with capstan head handle, screwed down high pressure screwed for iron pipe or for brass ferrule complete all as specified & directed. |
| 17 | S & Fin repair CP shower rose 150x150mm with 190mm long shower arm rod all as specified and directed. |
| 18 | S&F in repairs 15mm Brass CP mixer for mixing hot & cold water 15mm dia chromium plated , complete all as specified and directed. |
| 19 | S&F in repairs 15 mm dia stop valve cast copper alloychromium plated with capstan head handle, screwed down high pressure screwed for iron pipe or for brass ferrule complete all as specified & directed. |
| 20 | S&F in repairs15mm diaangle valve, chromium plated, screwed down high pressure, with crutch or butterfly handlescrewed both ends for iron pipe on for unions, complete all as specified and directed. |
| 21 | S&F in repairs Two way Bib cock, fancy type chromium platedcast copper alloy with capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed complete in all respect as specified. |
| 22 | S&F in repairs Health Faucet mild steel chromium plated suitable for 15 mm dai pipe with 1.25 mtr long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 23 | S&F in repairs 600 x 450 x 4 mm thick looking mirror bevelled edge of selected quality glass with PVC frame made of channel alround, mounted on 4mm thick commercial ply or AC building board fitted to wooden plug with CP brass screws complete all as specified & directed. |
| 24 | S&F in repairs factory made SFRC manhole covers 80mm thick, M-30, medium duty of size n.exc 1.00 Sqmeach, complete all as specified and directed. |
| 25 | S&F in repairs 110 mm bore PVC Pipes single socket, including all necessary tee, socket & bend as required in position complete all as specified and directed. |
| 26 | do- but 75mm bore. |
| 27 | S&F in repairs PVC bend/tee suitable for 110mm bore pipe complete all as directed |
| 28 | do- but 75mm bore. |
| 29 | S&F in repairs 12mm thick Medium density fibre board, exterior grade, fixed to timber framework with screws other side balancing white lamination, fixed with screw to timber frame work omplete all as specified and directed. |
| 30 | S&F white cement in bags of 25 Kgs packing complete all as specified and directed. |
| 31 | M&L for Glazed ceramic colour tiles in vertical surface of size 300x450x7 mmthick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick cement plaster in CM 1:4, including dismantling of wall tiling including cement mortor bedding (but not backing removing serviceable to store and rubbish off the premisesall as specified and directed. |
| 32 | M&L for Non Skid ceramic tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm ,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed or bedding layer inCM 1:6,including dismantling of floor or hearth tiling including cement mortor bedding (but not backing removing serviceable to store and rubbish off the premises all as specified and directed. |
| 33 | Uprooting and removing of wild growth trees from wall/roof/chajjas/CI pipes etc any location on buildings including removal of roots, sub roots upto 15cm girth etc, making good with PCC 1:2:4 or concrete in CM 1:3 as directed and finishes the surface matching with adjoining areas of wall/roof etc upto full height of bldgs (i.e. upto 9th storeybldg), including spaying Herbicide/ Weed killer as per manufacturer\"s instruction complete all as specified and directed |
| 34 | M&L brick workwith old size sub class B brick staight or curved on plan to any radious built in cement mortar (1:6) using sub class \"B\" bricks straight or curved on plan exc 6 mtr mean radious including demolition of brick work complete all as specified and directed by the Engr-in-Charge. |
| 35 | M&L rendering 15mm thick ready mix mortaron fair faces of brick work or concrete surfaces of walls/ceiling on external/internal surfaces and finished even and smooth without using extra cement including taking down old plaster of any description on walls complete all as specified. |
| 36 | M&L for rendering 10 mm thickwith ready mix plaster patches on fair face of ceiling and finished even and smooth without using extra cement, including taking down cement plaster of any description on brick wall or concrete surfaces including raking out joints in brick work, hacking for key, scrubbing down with water complete all as specified and directed. |
| 37 | M&L for preparation of new surface of wall and apply two coat of Oil Bound Distemper over and including Priming plastered and other surfaces with chalk whitening complete all as specified and directed. |
| 38 | M&L for preparation of new surface of ceiling and apply two coat of Oil Bound Distemper over and including Priming plastered and other surfaces with chalk whitening complete all as specified and directed. |
| 39 | Complete removal of existing treatment of wall usingwire brush/mechanical/ electrical driven sanders, washing, rubbing down and stoping of painted surface including preparation of surface etcand applying two coats of cement base paint all as specified and directed by Engineer-in-charge |
| 40 | S&F Solid PVC door frame of size 50mm x 47mm made out of5mm plain colour PVC sheet reinforced with M S square tube supplying and fixing in opening as per specification & drawing. it shall be wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet complete all as specified and directed |
| 41 | S&F Factory Made Solid panel PVC door shutter 30mm thick(style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beadingand jointed together with solvent cement fixing in the frame at site as per specifications and drawing.it shall be laminated with wood grain printed PVC sheet used instead of Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet beading.complete all as specified and directed.. |
| 42 | 75 mm thick, PCC (1:4:8), type D-2 (using 40 mm graded stone aggregate), as in sub base under floor including demolition of cement concrete (unreinforced) in ground floors and paving not exc. 15cm thickness (below or above ground level), complete all as specified. |
| 43 | 50mm thick fine sand layer spread uniformly over sub base complete all as specified. |
| 44 | Machine pressed precast glossy finish reflective type concrete interlocking tiles/paver block any colour, shape and size (as approved by GE) conforming to IS 15658 of 60mm thickness M-35 grade including filling the joints upto full depth with fine sand,including dismantling of pavers blocks/tiles of any description or thickness in floors, aprons etc. laid dry or laid dry or pointed, complete all as specified and directed by Engr-in-Charge. |
| 45 | Taking down wooden/steel chowkhats/door frame including shutter (without taking off shutter) not exc.1.5 Sqm eachcomplete all as spd & directed. |
| 46 | S&F for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, angle iron chowkhats; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165 including fixing of hold fast with bed block of size 200x200x15mm in CM 1:2:4 (using 20mm graded agg complete all as specified and directed. . |
| 47 | M&L 75 mm thick in PCC 1:3:6 type C-2 (using 20 mm graded crushed stone aggregate)finished even and fair at top using extra cement and providing joints throughout the thickness of plinth protection, including demolition of cement concrete n.exc 15CM thickness (below or above ground level) all as directed at site. |
| 48 | S&F CP tubular towel rail 600mm long 20 mm diacomplete all as specified and directed. |
| 49 | S&F25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 50 | S&F in repair grating doom 75mm dia of CP complete all as specified and directed. |
| 51 | S&F in repair grating doom 100mm dia of CP complete all as specified and directed. |
| 52 | S&F CPVC pipe 15mm internal dia with all fittings and fixed complete to walls ceilings or laid in floors of medium grade including taking downsteel tubing and connections incl cleaning for refixing or removal to store complete all as specified and directed. |
| 53 | S&F in repair European vitretious china wash down water closet pan (excluding flushing cistern but including flush pipe and pvc seat cover white. |
| 54 | Cleaning and removing all scales and dirt etc from tanks and from mouths of circulating pipe etc for more than 15000 ltrs capacity of tanks over 9 storey bldg, complete all as specified and directed.NOTE:- After cleaning the tank date of cleaning also has to be mentioned with synthetic enamel paint on the outer peripheral surface of tank in proper manner. |
| 55 | S&F in repairs aluminium anodized extruded bow handle fabricated type 125mm long complete all as specified and directed. |
| 56 | S&F in repairs 100 mm long mild steel butt hinges, medium weight, cold rolled and fixed complete all as specified and directed. |
| 57 | S&F in repairs 200mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 58 | S&F in repairs 10 Ltrs capacity PVC low level flushing cistern complete with syphone handle lever PVC bend including connecting to WC and fixing on walls with bracket complete all as specified and directed. |
| 59 | S&F in repairs white Plastic water closet seat cover, closed pattern with flat bottom,and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 60 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mmcomplete all as specified and directed. |
| 61 | S&F in repairs 32 mm PVC waste pipe 900 mm long with complete all as specified. |
| 62 | S&F sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes;including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm all as specified and directed. |
| 63 | S&F in repair Vitreous China wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets |