| 1 | Taking up or down GI/ PVC/ PP-R water tubing and connections including cleaning the pipes free from scaling for reusing the same in repairs / alteration etc to water pipes and connections complete all as specified and directed for the following sizes:- |
| 2 | 15 mm bore. |
| 3 | 20 mm bore. |
| 4 | 25 mm bore |
| 5 | 40 mm bore. |
| 6 | 50 mm bore. |
| 7 | 75/80 mm bore. |
| 8 | 100/110 mm bore |
| 9 | 150 mm bore |
| 10 | Re-laying /refixing or reroutingof GI/ PVC/ PP-R old water tubing and connection in new or old position including fittings with old/new bends, elbows, socket nipples, tapers, and reducers etc as per site requirement (on floors, walls and ceilings) complete all as specified and directed. |
| 11 | 15 mm bore. |
| 12 | 20 mm bore. |
| 13 | 25 mm bore |
| 14 | 40 mm bore. |
| 15 | 50 mm bore. |
| 16 | 75/80 mm bore. |
| 17 | Supply, lay and fixing steel water tubes,medium grade, ISI marked, galvanized with all fitting laid in trenches complete all as specified and directed forfollowing bore of pipes :-Note :- Excavation and Earth work shall be measured and paid separately. |
| 18 | 15 mm bore. |
| 19 | 20 mm bore. |
| 20 | 25 mm bore |
| 21 | 40 mm bore. |
| 22 | 50 mm bore. |
| 23 | 80 mm bore. |
| 24 | 100 mm bore. |
| 25 | 150mm bore. |
| 26 | Supply, laying and testing of Polypropylene random copolymer (PP-R) (PN-16/SDR 7.4) 3 layeredpipes, UV stabilized and antimicrobial welded having thermal stability with and including all PP-R plain & brass threaded polypropylene random fittings fixedsuch as bends, Elbow, Tee, Short Length, Socket, Union, Check Nuts, Nipples etc. (Females / Males as required), suitable for hot cold water supply line including making good disturbed surfaces/ cutting chassis in CM 1:3, laid in trenches and including testing complete all as per manufacture’s instruction and all as specified and directed for the following outer dia of pipes:-Make:- SUPREME/ PRINCE/ KPT |
| 27 | 20 mm bore (OD) |
| 28 | 25 mm bore(OD) |
| 29 | 40 mm bore(OD) |
| 30 | 50 mm bore(OD) |
| 31 | S&F in repair GI fittings 15 mm bore, heavy grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings :-Make - UNIK/ HB/ NIKE |
| 32 | Union |
| 33 | All equal Tee |
| 34 | Socket |
| 35 | Nipple 50mm Long |
| 36 | Nipple 100mm Long |
| 37 | Nipple 150mm Long |
| 38 | Plug |
| 39 | Elbow |
| 40 | All as per BOQ serial item No 5.00 described here-in-before but for 20 mm bore. |
| 41 | Union |
| 42 | All equal Tee |
| 43 | Socket |
| 44 | Nipple 50mm Long |
| 45 | Nipple 100mm Long |
| 46 | Nipple 150mm Long |
| 47 | Plug |
| 48 | Elbow/reducer elbow 20x15mm |
| 49 | Elbow |
| 50 | All as per BOQ serial item No 5.00 described here-in-before but for 25 mm bore. |
| 51 | Union |
| 52 | All equal Tee |
| 53 | Socket |
| 54 | Nipple 50mm Long |
| 55 | Nipple 100mm Long |
| 56 | Nipple 150mm Long |
| 57 | Elbow |
| 58 | Plug |
| 59 | Reducer elbow 25mm x 20mm |
| 60 | Reducer elbow 25mm x 15mm |
| 61 | All as per BOQ serial item No 5.00 described here-in-before but for 40 mm bore. |
| 62 | Union |
| 63 | All equal Tee |
| 64 | Socket |
| 65 | Nipple 50mm Long |
| 66 | Nipple 100mm Long |
| 67 | Nipple 150mm Long |
| 68 | Elbow |
| 69 | Reducer elbow 40mm x 25mm |
| 70 | Reducer elbow 40mm x 20mm |
| 71 | Reducer elbow 40mm x 15mm |
| 72 | All as per BOQ serial item No 5.00 described here-in-before but for 50 mm bore. |
| 73 | Union |
| 74 | All equal Tee |
| 75 | Socket |
| 76 | Elbow |
| 77 | Nipple 50mm Long |
| 78 | Nipple 100mm Long |
| 79 | Nipple 150mm Long |
| 80 | Reducer elbow 50mm x 25mm |
| 81 | Reducer elbow 50mm x 20mm |
| 82 | Plug |
| 83 | All as per BOQ serial item No 5.00 described here-in-before but for 80 mm bore. |
| 84 | Union |
| 85 | All equal Tee |
| 86 | Socket |
| 87 | Elbow |
| 88 | S&F in repair gun metal gate valve, ISI embossed, conforming to IS 781-1984, connected with iron wheel head, screwedat both ends for iron pipes and fixed including taking down of unserviceable gate valve complete all as specified and directed for the following sizes:- |
| 89 | 15 mm bore. |
| 90 | 20 mm bore. |
| 91 | 25 mm bore. |
| 92 | 40 mm bore. |
| 93 | 50 mm bore. |
| 94 | S&F in repair PP-R Gate valves (brass insert) with iron wheel head, screwed both ends for PP-R Pipes forfollowing bore of pipes :- Make:- SUPREME/ PRINCE/ KPT |
| 95 | 15 mm bore. |
| 96 | 20 mm bore. |
| 97 | 25 mm bore. |
| 98 | 40 mm bore. |
| 99 | 50 mm bore. |
| 100 | Excavation in trenches not exc 1.5m wide and not exc 1.5m depth for laying of pipe lines, valve chambers, manholes etc including forming bottom surface to required level and gradient and getting out in hard /dense soil complete all as specified and directed. |
| 101 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and directed. |
| 102 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 103 | M&L for cutting of road up to a sizenot exc 1.5m wide and not exc 1.5m depth for laying of water pipe lines making good the disturbed surfaces so as to match with existing finishing with PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) complete all as specified and directed. |
| 104 | S&F in repair brass stop cock complete all as specified and directed for the following sizes :- |
| 105 | 25 mm bore |
| 106 | 40 mm bore. |
| 107 | 50 mm bore |
| 108 | S&F in repair iron ball valve complete all as specified and directed for the following sizes :- |
| 109 | 25 mm bore |
| 110 | 40 mm bore. |
| 111 | 50 mm bore |
| 112 | 80 mm bore |
| 113 | Taking down the existing unserviceable point wiring of any description, type, size of light or fan or power or two way or bell etc on TW batten or conduit including removal of batten or conduit or gutters or wooden boards or switches or sockets or regulators or light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall or ceiling to match with the existing surfaces complete all as specified and as directed. |
| 114 | M&L for point wiring complete with stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded drawn through and including rigid 20mm dia PVC medium grade conduit and conduit accessories duly ISI marked on surface etc., with new sunk type pressed steel terminal boxes suitable forswitches duly painted with two coats of red oxide zinc chrome primer with suitable hylam sheet cover of suitable size for mounting of switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLSconforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly and making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and as directed. for the following :- |
| 115 | One light / fan point controlled by one, one way switch 5 amps, single pole. |
| 116 | One 3 pin 5 amps switch socket outlet point controlled by one switch on independent board |
| 117 | One 3 pin 5 amps switch socket outlet point controlled by one switch on same board |
| 118 | Ditto all as per item No. 20.00 described here-in-before but using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated unsheathed 1100 volts grade FRLS confirming to IS-694 for 3 pin 15 amps switch socket combination point on independent board and running of 2.5 Sqmmcopper conductor PVC insulated cable FRLSas earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed |
| 119 | S&F switch piano, single pole one way, flush type, 5 Amps 230 volts for light, fan and tube light ISI marked complete all as specified and as directed. |
| 120 | S&F switch socket combination 2 in 1, multipurpose 3/5 pin of 5 amps, flush type ISI marked complete all as specified and as directed. |
| 121 | S&F switch socket combination 2 in 1, multipurpose 6 pin of 15 amps, flush type ISI marked complete all as specified and as directed. |
| 122 | S&F fan regulator, 5 stepped, electronic type, single phase, socket size ISI marked complete all as specified and as directed. |
| 123 | S&F lamp holder insulated body surface bakelite with back plate ISI marked suitable for angle / batten fittings fixed with wooden round blocks complete all as specified and as directed. |
| 124 | S&F ceiling rose of surface bakelite 65 X 50 mm, three terminals ISI marked complete all as specified and as directed. |
| 125 | S&F wall mounted indus plus LED batten with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 2 x 22w, 230 volts, bipin holders, DIFFUSED TYPE connector block internally prewired etc with necessary mounting arrangements including all accessories with new 3 core multi stranded copper conductor of size 23/0.193 from ceiling rose to fitting and including LED Tube 20Wincluding taking down existing unserviceable tube light fitting complete all as specified and as directed. Make : Havells cat No-STREAKNEOT8UPTO2X22WSSBSWH incl Tube Rod cat No-PHOTONULTRAE2.01213T8SSTL20WLED865SPC or equivalent make in Wipro/ Philips. |
| 126 | S&F in replacement LED security light luminaire fitting of 1x45 watts with deep drawn housing including all accessoriescomplete all as sepcified and as directed. Make - Havells Cat No - ENDURASUNDOWNSL45WLED765PASYBOPC or equivalent make in Wipro/ Philips. |
| 127 | S&F in replacement recess mountingwith perforated sheet with electronic driver luminaire 36 watts LED slim panel with central opal diffuser series mounted in ceiling surfaces including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting,with 36 watts LED lamp complete all as specified and as directed. Make - Havells Cat No - VENUSNEOHE2X2PLR18-42WLED865MOD or equivalent make in Wipro/ Philips. |
| 128 | S&F sheet metal enclosure MCB DB SPN 8 Way with 200 Amps rated bus bar of 240 Volts, double door with magnetic locking system for fixing MCB’s / isolators including taking down existing old unserviceable MCB DB complete all as specified and as directed. |
| 129 | S&F sheet metal enclosure MCB DB SPN 4 Way with 200 Amps rated bus bar of, 240 Volts, double door with magnetic locking system for fixing MCB’s / isolatorsincluding taking down existing old unserviceable MCB DBcomplete all as specified and as directed. |
| 130 | S&F MCB SPN 40 amps 240 volts \"C\" curve suitable for fixing in MCB DBincluding taking down existing old unserviceable MCB complete all as specified and as directed. |
| 131 | S&F MCB SP 6 to 32 amps 240 volts\"C\" curve suitable for fixing in MCB DBincluding taking down existing old unserviceable MCB complete all as specified and as directed. |
| 132 | M&L for sub main wiring with two runs of single core FRLS PVC multistranded stranded unsheathed copper conductor cable of size 6 square mm and drawing through PVC conduit of 25mm dia with accessories on surface in wall/roof along with one run of 6 square mm FRLS PVC insulated unsheathed multi stranded 1100 volts grade with copper conductor cable as earth continuity conductor connected to earth and earth dolly, connecting to main board including removing the existing wiring and making good the disturbed wall surfaces to match with the surroundingscomplete all as specified and directed.Note: 3 runs of 6 Square mm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. |
| 133 | M&L for sub main wiring with tworuns of single core FRLS PVC insulated, multistranded unsheathed copper conductor cable of size 2.5 square mm and drawing through PVC conduit of 20mm dia with accessories on surface in wall/roof along with one run of 2.5 square mm FRLS PVC insulated unsheathed multi stranded 1100 volts grade with copper conductor cable as earth continuity conductor connected to earth and earth dolly, connecting to main board duly making good the disturbed wall surfaces to match with the surroundings complete all as specified and directed.Note: 3 runs of 2.5 Square mm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. |
| 134 | S&F in replacement environmental fridendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs all as specified and directed.Make - Havells Cat No RUGBYGENXFTS10WLED865SSYMBOPC or equivalent make in Wipro/ Philips. |
| 135 | S&F in replacementGI bracket 40 mm dia0.60 Mtr length fixed on wall with 50x6 mm flat iron, clamps, nuts and bolts including taking down existing unserviceable bracket complete all specified and direded. |
| 136 | S&F in replacement environmental friendly, energy saving long life corrosion resistant, vertical surface mounting pressure die-cast aluminium housing (light engine) well glass luminaires with high power LED as light source of 40 watts complete all as specified and as directed.Make - Havells cat No STUPEWGP40WLED757SSYMTOPCGRY or equivalent make in Wipro/ Philips. |
| 137 | S&F MS ERW steel tubing of nominal dia 500mm as per IS 3589 (Gr.330) of 6 mtr length, 12 mm thickness. 2 xDammi plate of 800mm dia of 14mm thicknessfor fixing both end. 1x200 MM and 8x150mm Flangh for connection ofSluice Valves ( 2 Incoming, 7 Outgoing).8Nos 150 mm Flangh for connecting existing pipe and 1 No 200 mm Flangh for inlet connectionincluding providing jointing material such as rubber fiber board gasket, suitable size bolts and nuts and washers, necessary supports, including welding and framed work such as MS connecting pieces for water pressure header with all fittings such 150x100 Reducer as one end flanged and other end reducers/bell mouth pieces, bends, blanking plate, tapers, any type and radius and angle, tee pieces single branch, \"Y\" junction double branch, both end flanged including gas welding machine wk etc for provision of water pressure header includinglath work finishing and painting with two coat of approved paint, all ends socket, all ends flanged etc of dia up to 500mm made out of MS plate suitable thick conforming to Fe-410-W(Gde-E-250) quality B including taking down old one complete all as specified anddirected. |
| 138 | Supply and laying pipes ERW steel including specials, as per IS 3589 (1981) 8.00mm thick and including cutting work, welding work and preparation of new steel surface and applying two coat of synthetic enamel paint over a coat of primer including taking down old unservicevable pipes complete all as specified and directed for the following sizes :- |
| 139 | 150 mm bore. |
| 140 | 200 mm bore. |
| 141 | S&F CI non return valve 150MM dia without by pass arrangement confirming to IS-5312 part-I, PN 1.6 including nuts, bolts, washers and gaskets including taking out old UNSV NRV complete all as specified. Make : Kartar/Kirloskar/Leader |
| 142 | S&F \"MS flange as per ASA 150# \"of thickness not less than 12mm inculding welding work as required at site complete all as required and as directed for the following sizes :- |
| 143 | 150 mm dia |
| 144 | 200 mm dia |
| 145 | S&F flange rubber gasket complete all as required and as directed for the following sizes :- |
| 146 | 150 mm dia |
| 147 | 200 mm dia |
| 148 | S&F CI flanged \"\"T\"\" type strainers with SS mesh of size 150MM dia, PN 1.6 including nuts, bolts, washers and gaskets including taking out old UNSV complete all as specified. Make : Kartar/Kirloskar/Leader |
| 149 | S&F in replacement of CI raising spindle type sluice valveboth ends flanged with CI body, ISI marked, IS 14846, pressure PN 1.6 with SS spindle with clamps and check nuts, operating hand wheel complete all as specified and directed for the following sizes:-Make : Kartar/Kirloskar/Leader |
| 150 | 200 mm bore. |
| 151 | 150 mm bore. |
| 152 | M&L for pre-cast cement concrete (1:3:6) type C1, (using 20mm graded crushed stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar (1:4) including demolition of old masonry complete all as specified and directed |
| 153 | M&L for rendring 15mm thick on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement in CM (1:4) complete all as specified and directed. |
| 154 | M&Lfor PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete for pole / stay / postincluding necessary form work and demolition of old concrete complete all as specified and directed. |
| 155 | M&L for PCC (1:2:4) type B2 (using 40mm graded crushed stone aggregate) as in coping of poles / foundation for poles, struts, posts etc including necessary form work, finished the exposed surfaces fair and even without usingextra cement including demolition of old concretecomplete all as specified and directed. |
| 156 | Supply only Stequa 411 AE, refill. Declibac specification :-Chlorine tablets contained in plastic cylinderical sealed disposable sanitiser refill for disinfection of drinking water with arrangements of controlled release of disinfectant in water, suitable for operatiion through recommended dosing system replacement indication, visual and weight varition operation type non contact, non inhalatory, heavymetal contaminants (like Hg and Pb) in product media must be below detectio limit (BDL) and product must pass through acute toxicity test, based on which the product must be considered safe to use from human health safety point of view when use in recommneded dosage all as specified and as directed.Make - Declibac Technologies Pvt Ltd or equivalent make as approved by GE. |
| 157 | Supply, installation, commissioning and testing of LT panel board of size 1000x1150x300, indoor cubical type, floor mounted, vermin proof factory made of CRCA Sheet 2.00 mm thick and MS angle of size 40x40x5mm having suitable legs, both side openable with locking and key arrangement,powder coated with three phase, 415 volts, 50 Hz, AC supply all as directed by Engr-in-Charge and comprising of the following:-(a) MCCB 400 Amp 50 KA 4 pole -1 No Make-Havells Cat No-IHLLSEB40400 or equavlant to L&T/Schnider(b) FASD starter for 100 HP Heavy duty with relay 66-120 Amp - 1No.Make-Havells Cat No-IHHASD4E*or equavlant to L&T/Schnider(c) Pump ON and Supply ON indicator- 1 Set(d)Phase indicating lamp RYB neon type (Set of three ) -01 Set (e)Voltmeter Digital type 0-500 Volts capacity with selector switch. (f)Ammeter Digital type 0-600 Amp capacity with selector switch and CT coils (g) Fully automatic phase sequence corrector to correct input reverse phase and also protect against single phasing voltage unbalancing, low high voltage with time delay 4 to 7 second, over load protection and automatic digital timer switch with automatically on/off the motor starter upto 100HP as per time setting-01 No.(h) Complete internal wiring with suitable size copper conductor and cable lugs & glands complete. (j) Masonry and concrete work for grouting of legs in foundation for mounting of panel -01 Job(k) Cable glands of suitable sizes for cable entry and exit.Note: Contractor shall submit the drawing of LT panel for approval of GE before procurement |