}

Tender For Repair/Maintenance Of Dg Sets, Amf Panels, Lt Servo Stabilisers And Connected Works At Haft Chinar Under Ge 970 Ews, srinagar-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Dg Sets, Amf Panels, Lt Servo Stabilisers And Connected Works At Haft Chinar Under Ge 970 Ews. Submission Date for this Tender is 17-06-2024. Diesel Generators Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43439407
Corrigendum : Tender For Repair/Maintenance Of Dg Sets, Amf Panels, Lt Servo Stabilisers And Connected Works At Haft Chinar Under Ge 970 Ews
Open Tender
Indian
Jammu And Kashmir
srinagar
17-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair/Maintenance Of Dg Sets, Amf Panels, Lt Servo Stabilisers And Connected Works At Haft Chinar Under Ge 970 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Jun-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-06-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 51000.0 /-
Tender Value
INR 25.50 Lakhs /-

Attachment

FileName File Description File Size
2deca587-4fb0-4b96-9336-3cb1d17cde6a.html Tender Notice 0 KB
18TENDER.pdf Tender Document 0 KB
BOQ_733270.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: REPAR/MAINT OF DG SETS, AMF PANELS, T SERVO STABILISERS AND CONNECTED WORKS AT HAFT CHINAR UNDER GE 970 EWS.
Sl. No. Item Description
1Disconnecting the engine from base & alternater, labour for dismantling of the top section, top overhauling including replacement of worn out parts,reassembling, connecting with alternator includingtesting for satisfactory running to entire satisfaction of Engr-in-charge, complete all as specified and directed for 62.5 KVA capacity of any make. Note :- Spare parts will be measured seperately under respective item of schedule of work.
2Description all as per item No. 1 above but for 10KVA to 32.5KVA capacity complete all as specified and directed Note:- (Item 1.00 & 2.00) (i) Worn out parts required to be replaced will be measured and paid for separately. (ii) Dismantling as per site requirement for repair and any minor parts required for making the DG Set fully operational not mentioned in subsequent items is deemed to be included in rates quoted. SM/MES No : 02H/6054/DG/03, 02H/6030/-DG/03, 02H/6026-DG/01, 02H/6052/DG/03, 02H/6001-DG/03, 02H/6050/DG/03, 02H/6048/DG/03, 02H/6028-DG/03, 02H/6029-DG/03 , 02H/6045-DG/06 (Haft Chinar)
3Supply only in replacement cylinder liner with liner ring for DG set of 62.5 KVA, complete all as specified and directed.
4Description all as per item No. 3.00 above but for 10 KVA to 32.5 KVAcapacity, complete all as specified and directed.
5Supply only in replacement piston ring set for DG set of 62.5KVA capacity,complete all as specified and directed.
6Description all as per item No. 5.00 above but for 10 KVA to 32.5 KVAcapacity complete, all as specified and directed.
7Supply only in replacement gasket set with ‘O’ ring set for62.5KVA capacity of DG Set, complete all as specified and directed.
8Description allas per item No. 7.00 above but for10 KVA to 32.5 KVA capacity, complete all as specified and directed.
9Supply only in replacement inlet/exhaust valve pair for 62.5KVA capacity of DG Set, complete all as specified and directed.
10Description all as per item No. 9.00 above but for 10 KVA to 32.5 KVAcapacity, complete all as specified and directed.
11Supply only in replacement main bearing set for DG Set of 62.5 KVA capacity, complete all as specified and directed.
12Description allas per item No. 11.00 above but for 10 KVA to 32.5 KVAcapacity, complete all as specified and directed.
13Supply only in replacement main oil seal (Rear & Front) for DG Set of 62.5 KVA capacity, complete all as specified and directed.
14Description allas per item No. 13.00 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
15Supply and fixing in replacement flexible coupling for DG set of62.5 KVAcapacity, complete all as specified and directed.
16Description allas per item No. 15.00 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
17Supply and fixing in replacement lub oil filter for DG Set of62.5 KVA capacity, complete all as specified and directed.
18Description allas per item No. 17.00 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
19Supply and fixing in replacement fuel filter for DG Set of62.5KVA capacity, complete all as specified and directed.
20Description allas per item No. 19 above but 32.5 KVA/ 25 KVA/20 KVA/10 KVAcapacity, complete all as specified and directed.
21Supply and fixing in replacement fan belt for DG Set of62.5 KVA capacity, complete all as specified and directed.
22All as per item No. 21 above but for 10KVA to 32.5 KVA capacity, complete all as specified and directed.
23Supply only crank shaft as required 62.5 KVADG set of any make and model including testing complete all as specified and directed.
24All as per item No. 23 above but10 KVA to 32.5 KVA capacity, complete all as specified and directed.
25Supplyonly cam shaft as required 62.5 KVA DG set of any make and model including testing complete all as specified and directed.
26Supply only connector rod as required 62.5KVA DG set of any make and model complete all as specified and directed.
27Description allas per item No.26above but for10 KVA to 32.5 KVA capacity, complete all as specified and directed.
28Supply only in replacement head gasket with ‘O’ ring for 62.5 KVA capacity of DG Set, complete all as specified and directed.
29Description allas per item No. 28 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
30Supply only in replacement began for 62.5 KVA capacity of DG Set, complete all as specified and directed.
31Description allas per item No. 30 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
32Supply only in replacement main began for 62.5KVA capacity of DG Set, complete all as specified and directed.
33Description allas per item No. 31 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
34Extracting burnt /unserviceable valveseats 62.5 KVA DG set and re-fixings after cutting grinding and polishing as per new valves including head facing and transporting to and from work shop complete all as specified and directed.
35Description allas per srl item No 34 above but capacity 10 KVAto 32.5 KVA DG Set.
36Dismantling and taking down unserviceable fuel injector pump transporting to work shop for the following repairs DG sets transporting back to site re-fixing and testing after completion, complete, all as specified and directed.
37Calibration and complete repair of fuel injector pump of DG set 62.5 KVA (Pressure type) on work bench pressure supply of fuel as per standard procedure and testing, complete all as specified and directed.
38Description allas per srl item No 37 here-in-before,but capacity 10KVA to 32.5 KVA DG Set.
39Dismantling and taking down unserviceable fuel injector nozzle transporting to work shop forrepairs transporting back to site re-fixing and testing after completion, complete, all as specified and directed.
40Overhauling and testing of injector nozzle on test bench for fine mist spray including replacement unserviceable parts for DG set of capacity 62.5 KVA complete all as specified and directed.
41Description allas item no. 40 here-in here-in-beforebut for 10 KVA to 32.5 KVA DG set.
42Taking down turbo charger carefully dismantling and replacement of complete turbo chargeand re-fixing to its original position complete all as specified and directed for upto 62.5 KVA DG set.
43Taking down radiator complete from its mounting, dislodging top and bottom tank, cleaning complete tube by descaling solution and finally re-installing in original position, complete, all as specified and directed for 10 KVA to 62.5KVA.
44Preparation and Painting of complete DG set including frameby two coats of enamelled paint as per colour code by spray painting and marking etc complete, all as specified and directed for 62.5 KVA.
45Preparation and Painting of completeDG set including frameby two coats of enamelled paint as per colour code by spray painting and marking etc complete, all as specified and directed for 10 KVA to 32.5 KVA.
46Dismantling alternator from the engine base for repairing including transporting to workshop, reinstalling, reconnecting with engine including testing on load for 10 KVA to 32.5 KVA DG set, complete, all as specified and directed.
47All as item no. 46 here-in here-in-beforebut for 62.5 KVA DG set.
48Rewinding of armature with super enamelled copper of required size wire including varnishing, sleeves, cotton tape and heating etc. for DG Set of capacity 62.5KVA , complete, all as specified and directed.
49All as per srl item No 48 here-in-beforebut for10 KVA to 32.5 KVA DG set.
50Dismantling, rewinding of field coils of alternator with super enamelled wireincluding varnishingand heating including reassembling and testing for capacity of DG Set 62.5 KVA, complete, all as specified and directed.
51All as item No 50 here-in-before, but for 10 KVA to 32.5 KVA DG set
52Dismantling and taking down unserviceable self starter transporting to work shop for the repair and transporting back to site after completerepairs re-installation at site and testing after completion, complete, all as specified and directed.
53Repair to self starter including rewinding the coil winding, bearing pinion bush solenoid switch carbon brush and holder including transporting back to site, re-installing and testing complete all as specified and directed of 62.5 KVAcapacity DG Set.
54All as item No 53 here-in-before, but for 10 KVA to 32.5 KVA DG set.
55Dismantling and taking out olddynamo and transporting to workshop forrepairand transporting back to site after complete repair, reinstalling at site and testingcomplete all as specified and directed.
56Repair to Dynamo of DG Set of capacity 62.5 KVA DG set including rewinding of coil, replacement of GM Bush, housing plate, cutout plate and transporting back to site, re-installation connecting and testing complete all as specified and directed. Note:-Any minor item required for complete repair is deemed to be inclusive in quoted rates.
57All as item No 56 here-in-before, but for 10 KVA to 32 KVA DG set.
58Supply and fixing in replacement 12 V self starter for 62.5 KVA DG set.
59Supply and fixing in replacement 12 V self starter for 10KVA to 32.5 KVA DG set.
60Supply and fixing in replacement dynamo for 62.5 KVA DG set.
61Supply and fixing in replacement dynamo for 10 KVA to 32.5 KVA DG set.
62Supply and filling in replacement of engine oil including cleaning of engine oil chamber and replacement of gasket etc, complete, all as specified and directed.
63Isolating, disconnecting and transporting the LT Servo voltage stabilizer ofcapacity350 KVA workshop for repair, strip opening of stabilizer for inspection and accertaining the defects for repair & cleaning, servicing all serviceable acessories including reassembling after repair, preparation for and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load complete all as specified and directed. (Note:- Parts required for replacement will measured and paid seperately under respective items.)
64Replacement of digital voltmeter 0 to 500 volts 96x96mm flush typeincl taking out the old unserviceable, complete all as specified and directed.
65Replacement of LT current transformer ratio as per existing rating in LT panels incl taking out the old unserviceable, complete all as specified and directed.Make:- L&T/AE.
66Replacement of Auto/Manual selector switch of voltmeter/ammeter in LT panel boards incl taking out the old unserviceable , complete all as specified and directed. Make: AE/L&T
67Digital PCB Card/Plate for automatic voltage correction suitable for servo stabilizer of capacity upto 25KVAas per site requirement for type and make complete all as specified and directed.
68Description all as per srl item No. 67 here-in-before, but of capacity350 KVA DG Set.
69Taking down old burnt winding and replacement of Booster coil 350 KVA -03 Nos Dimmer coil 350Ams -03 Nos, carbone brush 350 Ams-03 Nos, Digitalmicro processorcentral card, 10 Kg Togrg RC plate including leathriede paper cotton tape, winding varnishes etc for stabilizeroil immersed type of capacity of 350 KVA by using suitable gauge super enamelled copper conductor as per existing winding , complete all as specified and directed.
70Supply of insulation transformer oil toping up into voltage stabilizer of different capacity complete with superior quality insulating oil BDV not less than 50 KV , complete all as specified and directed.
71Dehydration of transformer oil uoto BDV not less than 50 KV , complete all as specified and directed.
72Cast Iron dimmer gear set for automatic voltage correction capacity of 350 KVA with as per site requirement for type and make complete all as specified and directed.
73Micro limit switch with cam lever complete for servo stabilizer of capacity 350 KVA as per site requirement for type and make complete all as specified and directed.
74Replacement of indicator assembly LED type (RYB) in LT panel boards incl taking out the old unserviceable, complete all as specified and directed.
75Replacement of servo motor synchronous type of torgue capacity30 Kg for automatic voltage correction suitable for servo stabilizer of capacity of 350 KVA as per site requirement for type and make complete all as specified and directed.
76Servo Dimmer 200 Amps/Booster83 KAA coil for automatic voltage correction suitable for servo stabilizer of capacity of 350 KVA as per site requirement for type and make complete all as specified and directed.
77Carbon brush with holder assembly for servo stabilizer of capacity of 350 KVA as per site requirement for type and make complete all as specified and directed.
78Replacement of digital Amp meter ofexisting range and size96x96mm flush type in servo stabilizers incl taking out the old unserviceable, complete all as specified and directed.
79Bush rod brass for servo stabilizer of capacityof 350 KVA as per site requirement for type and make complete all as specified and directed.
80Taking down old unserviceable control wiring and replacement of control wiring using suitable gauge super enamelled copper conductor as per existing winding for stabilizer transformer oil immersed type of capacity 350 kVA complete all as specified and directed.
81Replacement of over load relay for 350 KVAvoltage stabilizer, complete all as specified and directed.
82Replacement of graphite carbon bursh suitable for Servo voltage stabilizer of any capacity upto 350 KVA, complete all as specified and directed.
83Replacement of Capacitor of capacity 1.42 to 4.0 MF + 5%, 440V, AC 50Hz, complete all as specified and directed.
84Replacement of Pinion with gear (Medium) suitable for servo stablizer of any capacity, complete all as specified and directed.
85Replacement of Pulsing Transformer heavy duty suiable for servo stablizer of any capacity, complete all as specified and directed.
86Replacement of Control Transformer heavy duty suiable for servo stablizer of any capacity, complete all as specified and directed.
87Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level, connecting to the Galvanised iron earth lead 32x6mm size , by means of bolts, nuts, check nuts and washers of galvanised iron and 32x6mm earth lead protected by provision of GI medium grade pipe 40mm bore including porovision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less thanb 4 Kg/Sqm) and frame of angle iron 25x25x3mm with lugs-02 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.50m long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangements, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplys soil to a distance not exceeding 50m, all as per electrical plate No 3 of SSR-2009 Part-I and connection to earth test point all as specified and testing on completion, complete all as specified and directed. Note:- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 32x6mm size and protection pipe of 40mm bore GI light grade.
88Off Load change over switch 63 Amps, 4 Pole madeout of Sheet steel enclosure including replacement of incoming and outgoinglugs and fixing arrangement on panel/wall complete after taking down old one , complete all as specified and directed.
89Description all as per srl item No. 88 here-in-before, but of 32 Amps capacity.
90Copper cable insulated unsheathed, multistranded of size 10 Sqmm three core, complete all as specified and directed.
91Supply and fixing of moulded case circuit breaker four pole 63 Amps 16 KA capacity 415V 50Hzincl taking out the old unserviceable, complete all as specified and directed.
92Supply and fixing of AVR suitable for DG set of capacity 10KVA to 62.5 KVA, complete all as specified and directed.
93Supply and fixing of Air filter suitable for DG set of capacity 10KVA to 62.5 KVA, complete all as specified and directed.
94Isolating, disconnecting and transporting the LT Servo voltage stabilizer ofcapacity3 KVA to 5 KVA workshop for repair, strip opening of stabilizer for inspection and accertaining the defects for repair & cleaning, servicing all serviceable acessories including reassembling after repair, preparation for and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load complete all as specified and directed. (Note:- Parts required for replacement will measured and paid seperately under respective items.)
95Isolating, disconnecting and transporting the LT Servo voltage stabilizer ofcapacity10 KVA to 25 KVA workshop for repair, strip opening of stabilizer for inspection and accertaining the defects for repair & cleaning, servicing all serviceable acessories including reassembling after repair, preparation for and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load complete all as specified and directed. (Note:- Parts required for replacement will measured and paid seperately under respective items.)
96Repair to unserviceable/burnt LT stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnishing, reassembling, replacement of knobs, LED"s etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC, complete all as specified and directed.
97Repair to unserviceable/burnt LT stabilizer of 10 KVA to 25 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnishing, reassembling, replacement of knobs, LED"s etc. and making fully functionalcomplete all as specified and directed.
98Replacement of over load relay for 3 to5 KVAvoltage stabilizer,complete all as specified and directed.
99Replacement of over load relay for 10 to25 KVAvoltage stabilizer, complete all as specified and directed.
100Supply, installation, commissioning & testing of CPRI approved LT panel board, indoor, cubical, dust and vermin proof made out of 2mm thick MS sheet and steel section with back door detachable type fitted with nuts, bolts and washers and frint doors openable type fitted with knobs and hinges CRCA sheet IP-43 grade protcetion and having locking arrangement including individual chamber for MCB and MCCBs having sufficient space for working. LT Panel shall be prewired with suitable size OVC insulated cipper conductor cable. The panel shall be powder coated and shall be mounted on angle iron frame made out of MS angle of size 50x50x6mm of height 30CM from floor level including taking down of existing panel board.The panel shall be be comprising of the following items :- (a) MCCB125 Amps 25 KA, 415volts four pole with adjustable thermal setting - 01 No (Incomer) (b) MCCB 63 Amps 16 KA, 415volts four pole with adjustable thermal setting - 02Nos (c) Digital Voltmeter 0-500 Amp range 96x96 Sqmm size with four way selector switch - 01 No (d) Digital Ameter with CTs 0-200 Amp range 96x96 Sqmm size with four way selector switch - 01 No (e) LED Indication Lamp - 03Nos (f) Aluminium strip bus bar sleeve insulated 300 amps capacity four pole mounted on epoxy insulators - 01 No (g) cable entry with double comprissioning glands and two with provision of two Nos earthing terminals. (h) Internal wiring of panel board with single core copper cable PVC insulated of suitable size and control fuses. (j) ON Load Changeover switch of 4 pole, 415 volt, 200 Amps capacity - 01 No
101Supply, laying, jointing and testing ofXLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete all as specified and directed. :-
102All as item No 101 but size of cable 16 Sqmm 2 Core.
103All as item No 101 butsize of cable25 Sqmm 3.5 Core.
104All as item No 101but size of cable 35 Sqmm 3.5 Core.
105Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in lany type of soil, complete all as specified and directed.
106M&L for returning,filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
107Removing excavated material to a distance not exc 50M anddepositing where directed at a level n.exc 1.5 mtr above the starting point, complete all as specified and directed.
108M&L filling of dry sand under and around LT cable to provide sand cushioing and in sub stn ducts/trenches, complete all as specified and directed.
109M/Lfor brickwell burntlocallyavailablesubclass "B" laid over sand cushioningtocableintrencheskeepingwidthofbrickparalleltothelengthofcable complete allasspecifiedanddirected.
110Supply and fixing in replacement LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.
111Supply and fixing in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail