Tender For Special Repairs / Replacement Of Pcc Poles With Steel Tubular Poles And Allied Works At Av Camp Of Aste Under Ge (Af) Marathahalli Bangalore., marathahalli-Karnataka

Military Engineer Services-MES has published Tender For Special Repairs / Replacement Of Pcc Poles With Steel Tubular Poles And Allied Works At Av Camp Of Aste Under Ge (Af) Marathahalli Bangalore.. Submission Date for this Tender is 17-06-2024. Electric Pole Tenders in marathahalli Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

43439297
Corrigendum : Tender For Special Repairs / Replacement Of Pcc Poles With Steel Tubular Poles And Allied Works At Av Camp Of Aste Under Ge (Af) Marathahalli Bangalore.
Open Tender
Indian
Karnataka
marathahalli
17-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Special Repairs / Replacement Of Pcc Poles With Steel Tubular Poles And Allied Works At Av Camp Of Aste Under Ge (Af) Marathahalli Bangalore.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Jun-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-06-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 94000.0 /-
Tender Value
INR 47 Lakhs /-

Attachment

FileName File Description File Size
531d098e-c210-4b2c-9941-b3a30264772c.html Tender Notice 0 KB
BOQ_733259.xls Tender Document 0 KB
TENDER8692.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : SPECIAL REPAIRS / REPLACEMENTOF PCC POLES WITH STEEL TUBULAR POLES AND ALLIED WORKS AT AV CAMP OF ASTE UNDER GE (AF) MARATHAHALLI BANGALORE.
Sl. No. Item Description
1Taking out / down old unserviceable PCC LT pole of any size complete including removal from site all as specified and directed.
2Taking down / removing existing junction box / MCBs of any type and capacitycomplete including removal from site all as directed by Engr-in-charge.
3Taking up underground unservicable cable of any size from existing trench / wall / pole including bricks, etc and removing of materials from work site all as directed by Engr-in-charge.
4Taking down / removing of existing street light with GI bracket & clamps of any size complete all as specified and directed.
5Supply and fix steel tubular swaged poles Type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck, Including foundation and coping complete all as specified and directed. Make- India tube and Co/ Kalinga Tubes/Bombay Tubes/India Electric Poles MFG Co/ Singh Profile,Pune
6Supply and fixing pole mounted junction box/bus bar chamber for loop connection of street light cable of size 295x195x100 mm with 63 amps aluminium busbar wrapped with PVC sleeves andmaintained the colour code and provision of making holes with GI nuts, bolts & washers for connections and mounted on hydrograpic insulators with nuts & bolts at both ends of busbar and suitable arrangement for fixing one no MCB complete all as specified and as directed. Make: Sintex , Cat No: GSJB3020 or equivalent model of Hensel/Rittel.
7S&F MCB, Single pole, 6 amps, 240 volts, ‘C’ curve, 10 KAall complete as specified and as directed. (Make :Legrand/ Hager/ABB/Siemens).
8M&L for one run of 2.5 Sqmm 3 Core (Nominal Area) PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) from pole junction box to light fitting with suitable size copper cable lugs and connector all complete as specified and directed. Make : Plaza/Polycab/Havell"s.
9Supply and fixing of Endura Cityliner Neo, 60 W LED Street Light fitting pressure die cast aluminium housing, heat resistance toughened glass, IP-66 protectioncomplete all as specified and directed. Make : Bajaj /CG/Philips/Havells
10Supply, erection, testing and commissioning KIOSK outdoor type LT feeder pillar boxofminimumsize 900mm(height) x 600mm (breath) x 500mm (depth) platform mounted, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos copper bus bar for distribution system and type tested at CPRI fabricated .The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheetand 3.00mm thick gland plate duly compartmentalized for each control gear and bus-bar, double door front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel angle iron legs of minimum size angle iron 25x3 mm .
11The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947 and including complete internal wiring with 1.5 sqmm copper wire and copper strip/wire from busbar to MCB input and MCB to cable connector of suitable length including PCC (1:3:6) type C-2 as in foundation of suitable size (30 cmbelow ground level & 40 cm above ground level) including necessary excavation and earth work complete all as specified and as directed alongwith comprising of the following accessories :- NOTE: Rate of earthwork and PCC are deemed to be inclusive in this item. PCC foundation of size as required in cement mortar 1:6 and plastering the same in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed comprising of the following fitment accessories.
12BUS BARS AND INTERNAL CONNECTIONS :The bus bars shall be made of Copper strip ,63 Amps rated of minimum length 450 mm wrapped with PVC sleeves andmaintained the colour code and provision of making holes with copper nuts, bolts & washers for connections and mounted on hydrograpic insulators with nuts & bolts at both ends of busbar - 04 Nos
13INCOMING : (a) MCCB 4 pole 415 volts 50 Hz adjustable thermal magnetic release of rating 63 Amps having breaking capacity 25 KA-01 No (Make : Legrand/Siemens/L&T/ Havells) (b) Digital Voltmeter 96 mm x 96 mm incl selectror switch suitable to read 0 volt to 500 volts , AC 50 Hz, Class-1.0- 01 No. (Make: L&T/Legrand/Siemens/Havells). (c) LED Pilot Lamp (for Incomers) suitable for 230/240 Volts AC supply complete with integral circuit & cluster LED of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (Make : Legrand/Siemens/L&T/Havells) (d) Digital timer for street light.
14OUTGOINGS : (a) MCB TPN of rating 32 Amps having breaking capacity 10 KA - 03 Nos Make : Legrand/Siemens/L&T/ Havells. (b) MCB SPN of rating 25 Amps having breaking capacity 10 KA - 02 Nos. Make:L&T/Legrand/Siemens/Havells (c)Spare pocket for 01 Nos MCB.
15Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
16Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc getting out and forming bottom surface to required gradient complete all as specified and directed
17Excavating in trenchesexceeding 1.5 m wide and not exceeding 3 m depth and not less than 1.5 min width for laying of cables & foundation of poles , stay assembly and getting out in any type of soil complete all as specified and directed .
18M&L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations for electric poles, filling and mass concrete complete all as specified and directed.
19M & L for PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in coping of the LT poles including form work complete all as specified
20M & L for G.I. tubing light grade of size 40mm bore including necessary fiitings for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
21Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe upto 150 mm dia suitable for0.4 mpa working pressure.
22Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified.
23Brick protection cover on cable with sub class "B" brick,laid dry and flat adjacent to each other complete all as specified and directed.
24Returning filling including spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick each complete all as specified.
25Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified.
26Supply and fixing in repair ofEarthing to panel with galvanised steel earth plate electrode60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2020, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point includingexcavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed.
27Supply and fixing earth continuity conductor or main galvanised earthing lead wire 4.00 mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron.