Tender For Improvements Of Mrl05-Arni Devikapuram Road To Vp Road Via Modaiyur, Uthur, Manapakkam, Kudimithangal Km 0/0 - 6/426 With 5 Years Maintenance In Package No.Tn24-315 Chetpet Block Of Tiruvannamalai District Under Pmgsy Iii (2023-24), chetpet-Tamil Nadu

Rural Development And Panchayats Department has published Tender For Improvements Of Mrl05-Arni Devikapuram Road To Vp Road Via Modaiyur, Uthur, Manapakkam, Kudimithangal Km 0/0 - 6/426 With 5 Years Maintenance In Package No.Tn24-315 Chetpet Block Of Tiruvannamalai District Under Pmgsy Iii (2023-24). Submission Date for this Tender is 19-06-2024. Road Work Tenders in chetpet Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

43428155
Tender For Improvements Of Mrl05-Arni Devikapuram Road To Vp Road Via Modaiyur, Uthur, Manapakkam, Kudimithangal Km 0/0 - 6/426 With 5 Years Maintenance In Package No.Tn24-315 Chetpet Block Of Tiruvannamalai District Under Pmgsy Iii (2023-24)
Open Tender
Indian
Tamil Nadu
chetpet
19-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Improvements Of Mrl05-Arni Devikapuram Road To Vp Road Via Modaiyur, Uthur, Manapakkam, Kudimithangal Km 0/0 - 6/426 With 5 Years Maintenance In Package No.Tn24-315 Chetpet Block Of Tiruvannamalai District Under Pmgsy Iii (2023-24)

Key Value

Document Fees
Refer document
EMD
INR 780000.0 /-
Tender Value
INR 3.89 Crore /-

Attachment

FileName File Description File Size
Tendernotice_1.pdf Tender Document 0 KB
48dda3c0-5cf1-456c-8d54-dd198fee0237.html Tender Notice 0 KB
BOQ_210469.xls Tender Document 0 KB
Tender_Document_TN24315.pdf Tender Document 0 KB

BOQ Items

Name of Work: Upgradation of MRL05-Arni Devikapuram road to VP Road via Modaiyur, Uthur, Manapakkam, Kudimithangal Km 0/0 - 6/426 with 5 years maintenance
Sl. No. Item Description
1MRL05-Arni Devikapuram road to VP Road via Modaiyur, Uthur, Manapakkam, Kudimithangal Km 0/0 - 6/426
2Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.
3KM 0/0 - 1/0
4KM 1/0 - 2/0
5KM2/0 - 3/0
6KM 3/0 - 4/0
7KM 4/0 - 5/0
8KM5/0 - 6/0
9KM6/0 - 6/426
10Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
11KM 0/0 - 1/0
12KM 1/0 - 2/0
13KM2/0 - 3/0
14KM 3/0 - 4/0
15KM 4/0 - 5/0
16KM5/0 - 6/0
17KM6/0 - 6/426
18Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
19KM 0/0 - 1/0
20KM 1/0 - 2/0
21KM2/0 - 3/0
22KM 3/0 - 4/0
23KM 4/0 - 5/0
24KM5/0 - 6/0
25KM6/0 - 6/426
26Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 (Gravel shoulder)
27KM 0/0 - 1/0
28KM 1/0 - 2/0
29KM2/0 - 3/0
30KM 3/0 - 4/0
31KM 4/0 - 5/0
32KM5/0 - 6/0
33KM6/0 - 6/426
34Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing thematerial with water at OMC in mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in sub base/base course on a well prepared surface and compacting with vibratory rollerto achieve the desired density
35KM 0/0 - 1/0
36KM 1/0 - 2/0
37KM4/040 - 5/0
38KM 5/0 - 6/0
39KM 6/0 - 6/426
40Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
41KM 0/0 - 1/0
42KM 1/0 - 2/0
43KM2/0 - 3/0
44KM 3/0 - 4/0
45KM 4/0 - 5/0
46KM5/0 - 6/0
47KM6/0 - 6/426
48Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surface treated with Primer cleaned with Hydraulic broom as per Technical Specification Clause 503.
49KM 0/0 - 1/0
50KM 1/0 - 2/0
51KM2/0 - 3/0
52KM 3/0 - 4/0
53KM 4/0 - 5/0
54KM5/0 - 6/0
55KM6/0 - 6/426
56Providing and laying bituminous macadam with hot mix plant using crushed aggregates ofgrading as per Table 500.4 premixed with bituminous binder, transported to site upto a lead of 1000 m laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolledto achieve the desired compaction as per Technical Specification Clause 504. (Using Waste Plastic)
57KM 0/212 - 1/0
58KM 1/0 - 2/0
59KM2/0 - 3/0
60KM 3/0 - 4/0
61KM 4/0 - 5/0
62KM5/0 - 6/0
63KM6/0 - 6/426
64Providing, laying and rolling of close-graded premix surfacing material of 25 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509(Using Waste Plastic)
65KM 0/212 - 1/0
66KM 1/0 - 2/0
67KM2/0 - 3/0
68KM 3/0 - 4/0
69KM 4/0 - 5/0
70KM5/0 - 6/0
71KM6/0 - 6/426
72Provision of 15 nos. rumble strips covered with premix bituminous carpet, 15-20 mm high at centre, 250 mm wide placed at 1 m centre-to-centre at approved locations to control speed, marked with white strips of road marking paint.
73KM 0/0 - 1/0
74KM6/0-6/426
75Construction of CC Pavement@ Ch:0/0 - 0/212 (212m)
76Construction ofCell FillCompacted Concrete Pavement (M30) over prepared sub base with coarse and fine aggregates conforming to IS:383, the size of coarse aggregate not exceeding25 mm minimumcement content of 375 kg per cum, mixing in concrete mixerat optimum moisture content, transporting to site, laying with wheel barrows or steel pans or with mechanical paver, compacting with plate vibrator, to achieve the designed flexural strength, finishing and curing as per Technical Specification.
77Construction of CC Pavement@ Ch:4/040 - 4/200 (160m)
78Construction ofCell FillCompacted Concrete Pavement (M30) over prepared sub base with coarse and fine aggregates conforming to IS:383, the size of coarse aggregate not exceeding25 mm minimumcement content of 375 kg per cum, mixing in concrete mixerat optimum moisture content, transporting to site, laying with wheel barrows or steel pans or with mechanical paver, compacting with plate vibrator, to achieve the designed flexural strength, finishing and curing as per Technical Specification.
79Provision for CD Works 1.50m RCC Slab culvert @ Ch:1/133
80Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.
81Supplying and Filling foundation and basement with filling sand in layers not more than 15cm . Thick well ramed, watered and compacted Complete complying with stanard specification.
82Cement concrete 1 : 2.5 : 5 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
83Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
84Below Sill Level
85Above Sill Level
86Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
87Cement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcement and fabricating charges, centering and shuttering but including curing and shall be finished smooth with cement mortar 1:3, 12mm thick. and with kraft paper without claiming extra as directed by the departmental officers complete complying with standard specifications.
88Supplying and Fabricating and placing in position MS steel or Ribbed Tor Steel for all Reinforced Cement Concrete works as per the design given including cost of steel and binding wire in all floors etc,Complete complying with stanard specification.(MS rod or RTS bar will be supplied departmentally at section stores and cost will be recoverd at issue rate). the binding wire shall supplied by the contactor.
89Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications
90Providing and laying Kraft paper barring between deck slab and bed block to the full width of seating.
91Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
92Gravel filling between body wall including cost and conveyance of gravel, labour for filling, watering and compacting etc complete complying with standard specification and as directed by the departmental officer.
93Provision for CD Works 1.50m RCC Slab culvert @ Ch:3/419
94Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.
95Supplying and Filling foundation and basement with filling sand in layers not more than 15cm . Thick well ramed, watered and compacted Complete complying with stanard specification.
96Cement concrete 1 : 2.5 : 5 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
97Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
98Below Sill Level
99Above Sill Level
100Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
101Cement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcement and fabricating charges, centering and shuttering but including curing and shall be finished smooth with cement mortar 1:3, 12mm thick. and with kraft paper without claiming extra as directed by the departmental officers complete complying with standard specifications.
102Supplying and Fabricating and placing in position MS steel or Ribbed Tor Steel for all Reinforced Cement Concrete works as per the design given including cost of steel and binding wire in all floors etc,Complete complying with stanard specification.(MS rod or RTS bar will be supplied departmentally at section stores and cost will be recoverd at issue rate). the binding wire shall supplied by the contactor.
103Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications
104Providing and laying Kraft paper barring between deck slab and bed block to the full width of seating.
105Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
106Gravel filling between body wall including cost and conveyance of gravel, labour for filling, watering and compacting etc complete complying with standard specification and as directed by the departmental officer.
107Provision for CD Works 1 No. of 2.00m RCC Slab culvert @ Ch:0/714
108Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.
109Supplying and Filling foundation and basement with filling sand in layers not more than 15cm . Thick well ramed, watered and compacted Complete complying with stanard specification.
110Cement concrete 1 : 2.5 : 5 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
111Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
112Below Sill Level
113Above Sill Level
114Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
115Supplying and Fabricating and placing in position MS steel or Ribbed Tor Steel for all Reinforced Cement Concrete works as per the design given including cost of steel and binding wire in all floors etc,Complete complying with stanard specification.(MS rod or RTS bar will be supplied departmentally at section stores and cost will be recoverd at issue rate). the binding wire shall supplied by the contactor.
116Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications
117Providing and laying Kraft paper barring between deck slab and bed block to the full width of seating.
118Cement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcement and fabricating charges, centering and shuttering but including curing and shall be finished smooth with cement mortar 1:3, 12mm thick. and with kraft paper without claiming extra as directed by the departmental officers complete complying with standard specifications.
119Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
120Gravel filling between body wall including cost and conveyance of gravel, labour for filling, watering and compacting etc complete complying with standard specification and as directed by the departmental officer.
121Provision for CD Works 1 No. of 2.00m RCC Slab culvert @ Ch:2/172
122Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.
123Supplying and Filling foundation and basement with filling sand in layers not more than 15cm . Thick well ramed, watered and compacted Complete complying with stanard specification.
124Cement concrete 1 : 2.5 : 5 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
125Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
126Below Sill Level
127Above Sill Level
128Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
129Supplying and Fabricating and placing in position MS steel or Ribbed Tor Steel for all Reinforced Cement Concrete works as per the design given including cost of steel and binding wire in all floors etc,Complete complying with stanard specification.(MS rod or RTS bar will be supplied departmentally at section stores and cost will be recoverd at issue rate). the binding wire shall supplied by the contactor.
130Providing and laying Kraft paper barring between deck slab and bed block to the full width of seating.
131Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications
132Cement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcement and fabricating charges, centering and shuttering but including curing and shall be finished smooth with cement mortar 1:3, 12mm thick. and with kraft paper without claiming extra as directed by the departmental officers complete complying with standard specifications.
133Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
134Gravel filling between body wall including cost and conveyance of gravel, labour for filling, watering and compacting etc complete complying with standard specification and as directed by the departmental officer.
135Provision for CD Works 1 No. of 2.00m RCC Slab culvert @ Ch:3/167
136Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.
137Supplying and Filling foundation and basement with filling sand in layers not more than 15cm . Thick well ramed, watered and compacted Complete complying with stanard specification.
138Cement concrete 1 : 2.5 : 5 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
139Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
140Below Sill Level
141Above Sill Level
142Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
143Supplying and Fabricating and placing in position MS steel or Ribbed Tor Steel for all Reinforced Cement Concrete works as per the design given including cost of steel and binding wire in all floors etc,Complete complying with stanard specification.(MS rod or RTS bar will be supplied departmentally at section stores and cost will be recoverd at issue rate). the binding wire shall supplied by the contactor.
144Providing and laying Kraft paper barring between deck slab and bed block to the full width of seating.
145Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications
146Cement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcement and fabricating charges, centering and shuttering but including curing and shall be finished smooth with cement mortar 1:3, 12mm thick. and with kraft paper without claiming extra as directed by the departmental officers complete complying with standard specifications.
147Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
148Gravel filling between body wall including cost and conveyance of gravel, labour for filling, watering and compacting etc complete complying with standard specification and as directed by the departmental officer.
149Provision for CD Works 1 No. of 2.00m RCC Slab culvert @ Ch:5/962
150Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.
151Supplying and Filling foundation and basement with filling sand in layers not more than 15cm . Thick well ramed, watered and compacted Complete complying with stanard specification.
152Cement concrete 1 : 2.5 : 5 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
153Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
154Below Sill Level
155Above Sill Level
156Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
157Supplying and Fabricating and placing in position MS steel or Ribbed Tor Steel for all Reinforced Cement Concrete works as per the design given including cost of steel and binding wire in all floors etc,Complete complying with stanard specification.(MS rod or RTS bar will be supplied departmentally at section stores and cost will be recoverd at issue rate). the binding wire shall supplied by the contactor.
158Providing and laying Kraft paper barring between deck slab and bed block to the full width of seating.
159Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications
160Cement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcement and fabricating charges, centering and shuttering but including curing and shall be finished smooth with cement mortar 1:3, 12mm thick. and with kraft paper without claiming extra as directed by the departmental officers complete complying with standard specifications.
161Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
162Gravel filling between body wall including cost and conveyance of gravel, labour for filling, watering and compacting etc complete complying with standard specification and as directed by the departmental officer.
163Provision for CD Works 1 No. of 3.00m RCC Slab culvert @ Ch:0/397
164Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.
165Supplying and Filling foundation and basement with filling sand in layers not more than 15cm . Thick well ramed, watered and compacted Complete complying with stanard specification.
166Cement concrete 1 : 2.5 : 5 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
167Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
168Below Sill Level
169Above Sill Level
170Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
171Supplying and Fabricating and placing in position MS steel or Ribbed Tor Steel for all Reinforced Cement Concrete works as per the design given including cost of steel and binding wire in all floors etc,Complete complying with stanard specification.(MS rod or RTS bar will be supplied departmentally at section stores and cost will be recoverd at issue rate). the binding wire shall supplied by the contactor.
172Providing and laying Kraft paper barring between deck slab and bed block to the full width of seating.
173Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications
174Cement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcement and fabricating charges, centering and shuttering but including curing and shall be finished smooth with cement mortar 1:3, 12mm thick. and with kraft paper without claiming extra as directed by the departmental officers complete complying with standard specifications.
175Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
176Gravel filling between body wall including cost and conveyance of gravel, labour for filling, watering and compacting etc complete complying with standard specification and as directed by the departmental officer.
177Provision for CD Works 1 No. of 3.00m RCC Slab culvert @ Ch:5/236
178Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.
179Supplying and Filling foundation and basement with filling sand in layers not more than 15cm . Thick well ramed, watered and compacted Complete complying with stanard specification.
180Cement concrete 1 : 2.5 : 5 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
181Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
182Below Sill Level
183Above Sill Level
184Cement concrete 1 : 2 : 4 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.
185Supplying and Fabricating and placing in position MS steel or Ribbed Tor Steel for all Reinforced Cement Concrete works as per the design given including cost of steel and binding wire in all floors etc,Complete complying with stanard specification.(MS rod or RTS bar will be supplied departmentally at section stores and cost will be recoverd at issue rate). the binding wire shall supplied by the contactor.
186Providing and laying Kraft paper barring between deck slab and bed block to the full width of seating.
187Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications
188Cement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcement and fabricating charges, centering and shuttering but including curing and shall be finished smooth with cement mortar 1:3, 12mm thick. and with kraft paper without claiming extra as directed by the departmental officers complete complying with standard specifications.
189Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
190Gravel filling between body wall including cost and conveyance of gravel, labour for filling, watering and compacting etc complete complying with standard specification and as directed by the departmental officer.
191Provision for Dismantling the existing 2 No. CD structures @ Ch:0/397 and Ch.0/714
192Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.
193Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
194Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202., Reinforced Cement Concrete
195Provision for Dismantling the existing 1 No. CD structures @ Ch:1/133
196Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.
197Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
198Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202.
199Provision for Dismantling the existing 1 No. CD structures @ Ch:2/172
200Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.
201Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
202Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202., Reinforced Cement Concrete
203Provision for Dismantling the existing 2 No. CD structures @ Ch:3/167 and Ch.3/419
204Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.
205Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
206Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202.
207Provision for Dismantling the existing 2 No. CD structures @ Ch:5/236 and Ch.5/962
208Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.
209Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
210Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202., Reinforced Cement Concrete
211Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202.
212Provision for Kilometre Stones
213Provision for Hectametre Stones
214Provision for Guard Stone in the all culverts
215Providingandfixingreflectiveroadstudsof‘categoryA’ Raisedpavementmarkersmadeout ofpolycarbonate/methylmethercrylate /ABSmouldedbodyconfirmingto ASTMD788and reflectivepanelswithmicroprismaticlenscapableofprovidingtotal internalreflectionofthe lightentering thelensfacewithretroreflectance andchromaticity valuesconforming to ASTMD4280.Thereflective raised pavement markers shallalsoconfirm totheMORTH circularNoRW/NH.33023/ 10/97-DO.IIIdt11.06.97. Theheight,widthandlengthshall notbelessthan15mm,90mmand100mmandwithminimumreflectivearea of13Sq.cm oneachsideandtheslopetothebaseshallbe35 +/ -5degree.Eachreflectorshall have aCIL notlessthanvaluesspecified inTable2ofsaidMORTHcircular. Thestrength of detachmentoftheintegratedcylindricalshanks,(ofdiameternotlessthan19+/ -2mmarid heightnotlessthan 30+/ - 2mm)fromthebodyistobe aminimumvalueof 500 Kgf.Fixing willbebydrillingholesontheroadfortheshankstogoinside, withoutnailsandusing epoxyresinbasedadhesiveaspermanufacturer’s recommendation andcompleteasdirected bytheengineer. Themarkershallsupportaloadof13635Kgtestedinaccordancewith ASTMD428Oandconfirming toIRC 35-2015guidelinesandMORT&Hspecification804 etc., complete
216RoadMarkers / Road Stud with Lens Reflector
217Providingandlaying ofhot applied Thermoplasticcompound2.5mm thick including reflectorising glass beads @ 250 gms persqmarea,thicknessof2.5mm isexclusive ofsurface applied glass beadsas perIRC:35.Thefinished surface tobelevel, uniformandfreefromstreaksandholesetccompleteasperMORT&Hspecification No.803
218Road Marking
219Providingand erectingof Retro-ReflectorisedCautionary,MandatoryandInformatorysigns {withdefinitionboard)madeoutofHighIntensityPrismaticGradeSheetingconfirmingto Type-IVstandardsof IRC-67:2012 and ASTM D4956 —09, specificationand fixed over 2mm thickAluminiumsheetfixedoverabacksupportingframeof 25mmx25mmx3mmMildSteel angleandsupportedonamildsteelanglepost75X75X6mmwithaclearheightofnotless than2. lOmfromthegroundleveltothebottomofthesignboardand0.60mbelowground level.ThesignpostshouldbepaintedasperIRC67-2012andfirmlyfixedtothegroundby meansofproperlydesignedfoundationwithM15gradecementconcrète45cmX45cmX60cm sizeincludingcostandconveyanceofallmaterials,equipment,Machineryandlabourwith allleads andlifts, loading charges necessary for satisfactory completion of thework as directedbytheengineerincharge.HighintensityRetro-Reflectrosheetshallconsistof minimumcoefficientof Retro-reflection asper Table6.6 of IRC67-2012.The retro- reflective sheetingshallbecoveredunder7yearwarrantyissuedforfieldperformanceanda certified copyofthreeyearsoutdoorexposurereportshallbeobtainedasper IRC67:2012 (as per MORT&HSpecificationNo.801)
22060cm equilator triangular Cautionary signBoard
22160cm circular mantatory
22280 cm x 60 cm rectangular (Informatorysigns)
22390 cm high octagon
224Metal bracket with type IX flotoscent prismatic reflective sheeting which is suitable for guard rail it is available one way/two way.Applied for metal crash barriers/ guard rail/ to provide reflection across wide range observation Reflector(Near culverts & trees)
225Provision for Citizen board
226Provision for Logo board
227Provision for Name board
228Provision for PMGSY Maintenance Board
229For the First Year from the date of completion of work
230For the Second Year from the date of cpmpletion of work
231For the Third Year from the date of completion of work
232For the Fourth Year from the date of completion of work
233For the Fifth Year from the date of completion of work
234GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail