Tender For Repair/Maintenance/Improvement Of Various Types Of Pump Sets With Allied Works Including Maintenance Of Swimming Pool And Distribution And Rising Mains At Af Stn Sirsa, sirsa-Haryana

Military Engineer Services-MES has published Tender For Repair/Maintenance/Improvement Of Various Types Of Pump Sets With Allied Works Including Maintenance Of Swimming Pool And Distribution And Rising Mains At Af Stn Sirsa. Submission Date for this Tender is 01-06-2024. Submersible Pump Tenders in sirsa Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

43422246
Corrigendum : Tender For Repair/Maintenance/Improvement Of Various Types Of Pump Sets With Allied Works Including Maintenance Of Swimming Pool And Distribution And Rising Mains At Af Stn Sirsa
Open Tender
Indian
Haryana
sirsa
01-06-2024

Tender Details

Tender For Repair/Maintenance/Improvement Of Various Types Of Pump Sets With Allied Works Including Maintenance Of Swimming Pool And Distribution And Rising Mains At Af Stn Sirsa

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-06-2024
2 29-May-2024 CORRIGENDUM Other 01-06-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR/MAINT/IMPROVEMENT OF VARIOUS TYPES OF PUMP SETS WITH ALLIED WORKS INCLUDING MAINTENANCE OF SWIMMING POOL AND DISTRIBUTION & RISING MAINS AT AF STN SIRSA
Sl. No. Item Description
1SCHEDULE "A" PART-I (PUMP & MOTORS)
2Taking down Electric/Induction motor 40 HP capacity, of any Make/Model from existing position, Shifting to workshop for the repair work, removing the burnt winding, cleaning rotor, stator, re-winding the motor with super enamelled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc and installing back to the original position, testing and commissioning on full load for 8 hrs continuous running complete all as specified & directed by Engr-in-Charge. NOTE :Bearing & Bush will be measured and paid separately under relevant items.
3-ditto- but for motor of capacity 20 HP, 3 phase, AC, 415V
4-ditto- but for motor of capacity 10 HP, 3 phase, AC, 415V
5-ditto- but for motor of capacity 1 to 2 HP, 1 phase, AC, 220V
6S&F in repairs TC 15 rubber Coupling including dismantling of old unserviceable from shaft complete all as specified and directed.
7M&L for Rewinding Submersible Motor 15 HP, 3 phase, AC, 415V with PVC insulated Copper wire of same Gauge High Class Insulating materials of the existing Size, Varnishing, Heating, etc., for the following capacities of Motor all as specified & directed. NOTE : Bearing & Bush will be measured and paid separately under relevant items.
8-ditto- but for submersible motor of capacity 20 HP, 3 phase, AC, 415V
9-ditto- but for submersible motor of capacity 25 HP, 3 phase, AC, 415V
10Taking down Unserviceable Centrifugal/ Mono Block/ Vertical High pressure Pump Set any type & any Model 7.5/10 HP by disconnecting from Motor, Suction and Delivery Line for carrying out repairs at Workshop by replacing Defective/ unserviceable Parts including Greasing replacement of Packing Sheet, Gland, Stud, Bearing, Cover Sheet & Lath Work of Impeller Shaft, etc. including transportation and Testing & Commissioning after replacement of parts, complete all as specified and directed. NOTE :Bearing & Bush will be measured and paid separately under relevant items.
11-ditto- but for pump of capacity 1 to 2 HP, 1 phase, AC, 220V
12Supply only Ball Bearing (as approved) suitable for Pump Set 7.5/10 HP, complete all as specified and directed.
13Supply only Ball Bearing (as approved) suitable for Pump Set 1-2 HP, complete all as specified and directed.
14S&F in repairs Gun Metal Bush (as approved) suitable for Pump Set 7.5-10 HP, complete all as specified and directed.
15Taking down Unserviceable Centrifugal Pump Set 20 HP by disconnecting from Motor, Suction and Delivery Line for carrying out repairs at Workshop by replacing following Defective Parts including Greasing replacement of Packing Sheet, Gland, Stud, Bearing, Cover Sheet & Lath Work of Impeller Shaft, etc. including transportation and Testing & Commissioning after replacement of parts, complete all as specified and directed. NOTE : New Spare Parts will be Measured and Paid separately.
16-ditto- but for centrifugal Pump Set of capacity 40 HP, 3 phase, AC, 415V
17Supply only Ball Bearing (as approved) suitable for Centrifugal Pump Set 20 HP, complete all as specified and directed.
18Supply only Gun Metal Bush (as approved) suitable for Centrifugal Pump Set 20 HP, complete all as specified and directed.
19Supply only Ball Bearing suitable for Centrifugal Pump Set 40 HP, complete all as specified and directed.
20Supply Gun Metal Bush suitable for Centrifugal Pump Set 40 HP, complete all as specified and directed.
21Supply only Gland Packing suitable 10mm complete all as specified and directed.
22Repair/Overhauling of Submersible Pump Set 15/20 HP including replacement of Unserviceable Parts as required, complete all as specified and directed. NOTE : Bearing, Bush & Impeller will be measured and paid separately under relevant items.
23-ditto- but for Submersibe Pump Set of capacity 25 HP, 3 phase, AC, 220V
24Supply only SS Impeller suitable for Submersible Pump Set 20 HP, complete all as specified and directed.
25Supply only Stainless Steel Bush suitable for Submersible Pump Set 20 HP, complete all as specified and directed.
26Supply only Thrust Bearing suitable for Submersible Pump Set 20 HP, complete all as specified and directed.
27Supply only SS Impeller suitable for Submersible Pump Set 25 HP, complete all as specified and directed.
28Supply only Stainless Steel Bush suitable for Submersible Pump Set 25 HP, complete all as specified and directed.
29Supply only Thrust Bearing suitable for Submersible Pump Set 25 HP, complete all as specified and directed.
30Taking down Unserviceable Pump Set, 1 to 2 HP by disconnecting from Motor, Suction and Delivery Line for carrying out repairs at Workshop by replacing Defective Parts viz Bearing/bush, Impeller, Capacitor, Water Seal, Washers & Lath Work of Impeller Shaft etc.complete all as specified and directed. NOTE : Cost of new bearing, bush, Seal, Washers, Impeller, etc. shall deem to be included in the Quoted Unit Rate.
31S&F in repairs Gun metal Air release valve suitable for any type Monobloc/Coupled pump set complete all as specified and directed.
32M&L for Preparing Old Painted/treated Surfaces of Pump Sets and Motors of any description including cleaning of Grease/Oil Spots, etc. from the Pump Sets and Motors and applying Two Coats of Synthetic Enamel Paint and re-writing SM No. and MES No. on Pump Sets and Motors of suitable size, complete all as specified and directed.
33Taking out Pumping Set for repair from Bore Well by dismantling Suction/ Delivery Column Pipe 50mm to 150mm dia and Lowering the Column Pipe after repairing the Pump including replacement of Gasket Set, worn out/ damaged Nuts and Bolts of required size carefully without causing any damage to the Pumping Set, Submersible Cable, complete all as specified and directed. NOTE : Job for taking out the Pumping Set consisting a Set of Pump & Motor shall be Paid for ONE Unit.
34M&L for Rewinding Submersible Motor, non clog, vertical type up to 1.5 HP, 3 phase, AC, 415V with PVC insulated Copper wire of same Gauge High Class Insulating Materials of the existing Size, Varnishing, Heating, etc. complete all as specified & directed. NOTE :- Cost of taking out Pump Set for repair from UG Sump by dismantling Delivery Pipe and refixing after repairing of Pump to be included in the Quoted Unit Rate.
35-ditto- but for Submersible Motor of capacity 3 HP, 3 phase, AC, 415V
36Repair/Overhauling of Submersible Pump Set, non clog, vertical type 2 to 3 HP including replacement of Unserviceable Parts as required, complete all as specified and directed. NOTE:- Cost of taking out Pumping Set for repair from UG Sump by dismantling Delivery Pipe and refixing after repairing the Pump to be included in the Quoted Unit Rate.
37Supply only SS Impeller suitable for Submersible Pump Set up to 3 HP, complete all as specified and directed.
38Supply only Stainless Steel Bush suitable for Submersible Pump Set 3 HP, complete all as specified and directed.
39Supply only Bearing suitable for Submersible Pump Set 3 HP, complete all as specified and directed.
40Repair/Overhauling of Submersible Pump Set, non clog, vertical type 4 HP including replacement of Unserviceable Parts as required, complete all as specified and directed. NOTE:- Cost of taking out Pumping Set for repair from UG Sump by dismantling Delivery Pipe and refixing after repairing the Pump to be included in the Quoted Unit Rate.
41Supply only SS Impeller suitable for Submersible Pump Set 4 HP, complete
42Supply only Stainless Steel Bush suitable for Submersible Pump Set 4 HP, complete
43Supply only Bearing suitable for Submersible Pump Set 4 HP, complete
44SCHEDULE "A" PART-II (PIPE LINES & VALVES)
45Supply, fixing & Lowering GI Column Pipe 80 mm bore (dia), 3.00 METRE in Length, medium grade, ISI marked, both End Flanged with Rubber/ Fibre Joints with Mild Steel Bolts, Nuts, & Washers, etc. including Taking down/ out unserviceable Column Pipe, complete all as specified and directed.
46-ditto- but for GI Column Pipe of size 100mm bore
47Excavating in trenches, not exc. 1.50 m Wide and depth not exc. 1.50 m for taking out/up and laying of Water Main /Pipe, etc., for foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and directed.
48Returning, filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Surplus Soil providing Heaps along the route of the Pipe Line in Soft/Loose Soil, complete all as specified and directed.
49S&F in repairs DI pipe fitting like Bends (any type, radius and angle) Tapers any type, (Straight, Bend, Increasing, Decreasing or Double Socket, etc.) Tee Pieces Single Branch, ‘Y’ Junction, Double Branch, Cross (all Sockets or Socket and Spigot) Collars, Caps and Plugs up to 200mm bore (dia) including removing damaged Fittings, complete all as specified and directed.
50Taking up or down DI Pipes with Fittings/ Connections, complete all as specified and directed.
51Supplying, laying, jointing and testing Ductile iron (DI) pipe of size 150 mm dia with spigot/ socket ends centrifugally cast type K-9, ISI marked, in any length, laid in trenches and connected to existing pipe line as required at site completewith jointing material (Rubber tyton joints) all as specified and directed (NOTE :- Excavation, earthwork , fittings shall be measured and paid separately)
52-ditto- but for DI pipe 100mm bore
53S&F in repair Cast Iron non-return valve, 80 mm bore, Class PN 1.0, heavy duty, ISI marked (IS 5312), flanged end including 3 mm thick rubber gasket joints, nuts, bolts etc complete all as specified and directed.
54Supply, Installation and testing of Chemical Dosing system suitable to inject solution up to 21 LPH comprising dosing pump coupled with three phase electric motor of capacity , 1440 RPM v3 phaseassembly including dismantling of old unserviceable dosing system complete all as specified and directed.
55S&F in repair Cast Iron Sluice valve of Class PN-1.6, 150 mm bore, long body type, heavy duty, ISI marked (IS 1538) flanged end with iron wheel and brass spindle including 3 mm thick rubber gasket joints, nuts, bolts etc complete all as specified and directed.
56-ditto- but Sluice Valve of 100 mm bore
57SCHEDULE "A" PART-III (RO PLANT)
58Routine Maintenance & Operation of CENTRAL REVERSE OSMOSIS TYPE WATER TREATMENT & PURIFYING PLANT having capacity of delivering Pure, Safe and Healthy Drinking Water 5000 LITRE PER HOUR by removing dissolved Solids like Calcium, Magnesium, Sodium Bicarbonate, Chlorides, Sulphides, etc. in Water by 90-95% and reducing Harmful Minerals like Arsenic, Fluorides, Lead, Bacteria, etc. and to bring Water Hardness Level to Safe Drinking Water Limits, Skid Mounted type including Routine Checking of Metering Equipments like Voltmeter, Ammeter, Flow Meter, Conductivity Meter (TDS Meter) PH Meter, Pressure Meter, etc. alongwith Routine Maintenance of RO Water Supply Pumping Set 3.0 HP capacity Each, complete all as specified and directed. NOTES :- (a) The Contractor shall engage One Experienced Technician who will visit at an interval of EVERY 30 DAYS and/or as and when required/directed by the Engineer-in-Charge to examine and repair the Plant.The Technician will report to the JE E/M and Engineer-in-Charge for his Every Visit, failing which no Payment will be allowed to the Contractor. (b) The Plant shall not remain Non Operation more than 8 HOURS in any case either due to Break down or Maintenance otherwise a recovery @ Rs. 300.00 PER HOUR shall be charged from the Contractor beyond 8 HOURS for Non Operation of Plant. (c) The Quoted Unit Rate includes fixing only for non workable major parts as and when required basis. (d) The Quoted Unit Rate includes the Cost of Chemicals as recommended by Manufacturer for Flushing/Cleaning the System. (e) The Quoted Unit Rate is inclusive of Periodical Back Wash or as and when required to maintain as per the Treatment Guideline of Plant including Cleaning. (f) The Cost include the replacement of Minor Spares like Washers Nylon/ Lead, Teflon Tape, Bolt & Nuts, Gland Packing, Gasket, etc. other than specifically Priced. (g) Major Spares like Micron Filter, Membrane etc. will be Measured and Paid for separately.
59Supply only Anti-Scalent Chemical (Consumable), in sealed containers, suitable for preventing Scaling of Membrane of Plant complete alland directed by Engineer in Charge.
60Supply only Micron Filter of size 4 Inch dia x 20 Inch Length with Filter capacity up to 1 micron (as approved) complete all as specified and directed.
61Supply only Membrane Module of size 8040 suitable for 5000 Litre Central RO Plant (as approved as existing) and Fixing-in-repairs, complete all as specified and directed. MAKE : TORRAY/ ION EXCHANGE/ DOW
62S&F in repairs Multi port valve of size 32/40 mm bore suitable for RO plant incl testing on completion complete complete all as specified and directed.
63SCHEDULE "A" PART-IV (SWIMMING POOL)
64Supply, fixing & testing Multi port valve of sizemm bore suitable for swimming pool incl taking down old one complete all as specified and directed.
65M&L for Cleaning Swimming Pool by Cleaning Entire Internal Surface by removing Dirt, Sludge, etc. with Wire Brush by applying Bleaching Powder and Fresh Water and Cleaning Entire Surface repeatedly with Fresh Water and Draining Out Soiled Water including using Pressure Jet Pump and Suction Pump capacity of Pool Surface using Acid and other suitable Methods before filling as required at Site, complete all as specified and directed. NOTE :- (a)Quoted Unit Rate shall include for filling the Swimming Pool with Water and de-watering as per requirement the Water Supply provided by Department. (b)The Quoted Unit Rate is inclusive of Chemicals required to Clean the Swimming Pool and Pump Sets, etc.
66M&L for Cleaning Level Tank & connected drain/trenches for Swimming Pool using Acid and other suitable methods before filling as required at Site, complete all as specified anddirected. NOTE : Quoted Unit Rate shall include for filling the Level Tank for Pool with water and de-watering as per the Water Supply provided by Department.
67M&L for Draining out Water by removing the Drain Plug from Swimming Pool Media Filter Tank, Take Off Multiport Collar (Clamp) unscrewing union from the Multiport Valve including carefully Opening, Covering to Stand Pipe with Duct Tape or Rubber Plug, Taking out Muddy and Dirty Sand by using Vacuum Equipment to suck out the Sand or using Plastic Tumbler Cup to scoop out the Sand, Taking out Water, Pouring Pipe Stand Pipe without damage and removing the Internal Grid Assembly carefully, replace to worn out Stand Pipe, Internal Grid Assembly or Multiport Valve, Cleaning to Filter with Dilute Acid or Soap or Anti Scalent Chemical for removing Sludge and Clean to Sand Filter, Pouring Water Half Tank and filing to Standard Silica Sand and Pea Gravel suitable for Swimming Pool Media Filter and replacing Worn Out "O" Ring with Serviceable "O" Ring with tightening Lubricant Reassembling to Main Holes, Servicing of Inlet, Outlet, Backwash and Air Release Diaphragm Valve along with water connection pipe, testing of Leak Proof, complete all as specified and directed. (NOTE: Sand, Pea Gravel, Anti-Scalent Chemical and accessories measured under Item No 4.07 shallbe measured seperately as "Supply Only". Quoted rate shall be deemed to include for all other spares and consumables. No claim shall be entertained during currency of work.
68Supply only Silica Sand 0.4-0.8mm for Swimming Pool Media Filter complete and all directed by Engineer in Charge.
69Supply only Pea Gravel 3.5-5.6mm for Swimming Pool Media Filter complete and all directed by Engineer in Charge.
70Supply only Accessories Filter, Valve of Media Filter including Taking out Old US Accessories Filter, Valve,complete and all directed by Engineer in Charge.
71M&L for preparing Old Painted/treated Surfaces of Main Panel including cleaning, removing loose paint flakes, rust etc, applying red oxide primer over rust patches and finishing with Two Coats of Synthetic Enamel Paint and re-writing Pump No. & ON OFF suitable size, complete and all directed by Engineer in Charge.
72S&F in repair Pressure Gauge/Vacuum Gauge with Nipple 0-14 Kg rating complete and all directed by Engineer in Charge.
73S&F in repairs Suction Sweeper PVC flexible Suction pipe 50mm complete and all directed by Engineer in Charge.
74S&F in repairs Suction Sweeper Brush (as approved), complete and all directed by Engineer in Charge.
75S&F in repairsSuction Sweeper castor wheels (as approved), complete and all directed by Engineer in Charge.
76M&L Taking down Defective Electric Motor 3.5 HP of existing make-Pentair, Dismantling the burnt out Winding Wire and Rewinding the Motor with Super Enamelled Copper Winding Wire using High Class Insulating Materials of the existing Size, Varnishing, Heating, etc., Re-assembling complete Motor and necessary Transportation, complete and all directed by Engineer in Charge.
77M&L for Repairing of Pump 3.5 HP of existing make-Pentair, including providing Seal/Gasket, Washers, Impeller, etc. as required at Site, complete all as specified and directed. NOTE:- Cost of new bearing, bush, Seal, Washers, Impeller, etc. shall deem to be include in the Quoted Unit Rate.
78Supply only Alum Grade 1 (as approved), in sealed bags complete all as specified and directed.
79Supply only Copper Sulphate (as approved), in sealed bags complete all as specified and directed.
80Supply only Soda Ash (as approved), in sealed bags complete all as specified and directed.
81Supply only Tricloro Cynuric Acid (TCCA-90) (as approved), in sealed containers complete all as specified and directed.
82Supply only Sodium Hypochlorite (Grade 1) as per IS:11673/86 (as approved), 0.50% concentration, in sealed containers complete all as specified and directed.
83Supply only Muriatic acid liquid (as approved), 31.45% concentration, in sealed container complete all as specified and directed.
84SCEDULE "A" PART-V (STARTER & PANELS)
85S&F in repairs MCCB 100 Amp, Ics=Icu, with adjustable thermal setting,3 Pole, 415 Volt, 50 Hz, 16 kA with necessary Connections with Thimbles, etc. complete all as specified and directed. (MAKE: INDO ASIAN, Cat No: 830228 or equivalent model in other makes listed in tender)
86-ditto- but MCCB of rating 125 Amps (MAKE: INDO ASIAN, Cat No: 830229 or equivalent model in other makes listed in tender)
87-ditto- but MCCB of rating 160 Amps (MAKE: INDO ASIAN, Cat No: 830280 or equivalent model in other makes listed in tender)
88-ditto- but MCCB of rating 200 Amps (MAKE: INDO ASIAN, Cat No: 830281 or equivalent model in other makes listed in tender)
89S&F in repairs of Analogue type Volt-Ammeter Class 1, 3Ph, 500 Volt, 0-125 Amp complete all directed. (MAKE: L&T, Cat No: CS90057OOOO or equivalent model in other makes listed in tender)
90S&F in repairs Single Phase Preventor, selectable under & over voltage suitable for 3 phase pump sets of any capacity complete all as specified and irected.
91Supply & laying Flat Copper Cable insulated, PVC Sheathed Water Proof, conforming to IS-694, 1100 Volt Grade suitable for Submersible Pump Set, Cross-sectional area 6.0 Sqmm, 3 Core including taking down/out unserviceable Cable, complete all as specified and directed.
92Supply & laying Flat Copper Cable insulated, PVC Sheathed Water Proof, conforming to IS-694, 1100 Volt Grade suitable for Submersible Pump Set, Cross-sectional area 10 Sqmm, 3 Core including taking down/out unserviceable Cable, complete all as specified and directed.
93SupplyInstallation & testing of3 Phase DOL Starter with wide band coil , Relay Range 9 to 14 Amp, 415 Volt, 50 Hz, suitable for 6 HP pump comprising with Voltmeter, Ammeter, single phase preventor, etc including Taking down old u/s starter, complete all as specified and directed. (MAKE : L&T Cat No. SS95983COAO or equivalent model in other makes listed in tender)
94SupplyInstallation & testing of3 Phase FASD Starter with wide band coil, Relay Range 20 to 33 Amp, 415 Volt, 50 Hz, suitable for 20 HP submersible pump comprising with Voltmeter, Ammeter, single phase preventor etc including Taking down old u/s starter, complete all as specified and directed. (MAKE : L&T, Cat No. CS96008COEO or equivalent model in other makes listed in tender)
95SupplyInstallation & testing of3 Phase FASD Starter with wide band coil, Relay Range 30 to 50 Amp, 415 Volt, 50 Hz, suitable for 30 HP submersible pump comprising with Voltmeter, Ammeter, single phase preventor etc including Taking down old u/s starter, complete all as specified and directed. (MAKE : L&T, Cat No. CS90908LOGO or equivalent model in other makes listed in tender)
96S&F in repairs Power Contactor, AC3 rating 25 Amps, Type MNX25, 3 phase, 3 pole, 415V, conforming toIS/IEC 60947-4-1 complete all as specified and directed. (MAKE: L&T, Cat No: CS94110 or equivalent model in other makes listed in tender)
97-ditto- but for 40 Amps, Type MNX 40 (MAKE: L&T, Cat No: CS94190 or equivalent model in other makes listed in tender)
98-ditto- but for for 50 Amps, Type MNX 50 (MAKE: L&T, Cat No: CS97075 or equivalent model in other makes listed in tender)
99-ditto- but for for 70 Amps, Type MNX 70 (MAKE: L&T, Cat No: CS97076 or equivalent model in other makes listed in tender)
100-ditto- but for 18 Amps, Type MNX 18 (MAKE: L&T, Cat No: CS94100 or equivalent model in other makes listed in tender)
101-ditto- but for 09 Amps, Type MNX 9 (MAKE: L&T, Cat No: CS94106 or equivalent model in other makes listed in tender)
102S&F in repairs Overload Relay, type MN2, 9 -15A relay range, suitable forStar Delta motor starters, directly mounting including all accessories complete all as specified and directed. (MAKE: L&T, Cat No: SS94142OOBO or equivalent model in other makes listed in tender)
103-ditto- but for 14 - 23A relay range. (MAKE: L&T, Cat No: SS94144OODO or equivalent model in other makes listed in tender)
104-ditto- but for 24 - 40A relay range. (MAKE: L&T, Cat No: SS94145OOFO or equivalent model in other makes listed in tender)
105-ditto- but for 30 - 50A relay range (Type MN5) (MAKE: L&T, Cat No: SS94136OOGO or equivalent model in other makes listed in tender)
106-ditto- but for 45 -75A relay range (Type MN5) (MAKE: L&T, Cat No: SS94137OOJO or equivalent model in other makes listed in tender)