Tender For Certain Maintenance Wks At Zone B And Repair/ Maintenance Of Internal Wiring And Connected Items For Aor Of Hq 6 Sect Under Age(I), Rajouri-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Certain Maintenance Wks At Zone B And Repair/ Maintenance Of Internal Wiring And Connected Items For Aor Of Hq 6 Sect Under Age(I). Submission Date for this Tender is 11-06-2024. Electrification Work Tenders in Rajouri Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43421592
Tender For Certain Maintenance Wks At Zone B And Repair/ Maintenance Of Internal Wiring And Connected Items For Aor Of Hq 6 Sect Under Age(I)
Open Tender
Indian
Jammu And Kashmir
Rajouri
11-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Certain Maintenance Wks At Zone B And Repair/ Maintenance Of Internal Wiring And Connected Items For Aor Of Hq 6 Sect Under Age(I)

Key Value

Document Fees
INR 500 /-
EMD
INR 18800.0 /-
Tender Value
INR 9.40 Lakhs /-

Attachment

FileName File Description File Size
5b4e9f05-4799-4cca-9816-4dc6f30768ba.html Tender Notice 0 KB
BOQ_732700.xls Tender Document 0 KB
TenderDocuments23.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:CERTAIN MAINTENANCE WKS AT ZONE "B" AND REPAIR/ MAINT OF INTERNAL WIRING AND CONNECTED ITEMS FOR AOR OF HQ 6 SECT UNDER AGE(I) CIF(R).
Sl. No. Item Description
1Taking down chowkhat or frame with shutter (without taking off shutter from the frame)exc. 1.50 Sqm but n exc. 4 Sqm each all as specified.
2Pressed steel frames factory made for doors out of 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs, hinges, lock strike plate, hinges etc complete, size of frame 125x60mm complete all as specified and directed
3S & F 30 mm thick second class hard wood factory made plain, framed, panelled shutters (two numbers of panels) with lock rail and panel of 9 mm BWP commercials ply or 12 mm veneered particle board on both faces.The size of rails and size as per IS:1003 (Part-I), Kiln seasoned & chemically pressure treated, complete all as specified and directed.
4S & F 30 mm thick second class hard wood factory made glazed and skelton shutters, open rebated and prepared to receive glass, gauge, etc. (without sash bars), edges of framing plain, chamered or rounded, fitted with cut and mitred beads for securing glass, etc.Size of memebers of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) for doors, complete all as specified and directed.
5S & F in repair floor door stopper of aluminium alloy body and tongue , anodised , with hard drawn steel spring, over all length of cover plate 140 mm , complete all as specified and directed.
6S & F 100 mm long butt hinges, medium wight cold rolled mild steel, complete all as specified and directed.
7S & F 125 mm extruded aluminium alloy handles, fabricated type, anodisedand, complete all as specified and directed.
8S & F 150 mm aluminium anodised barrel tower bolt of extruded section and fixed,complete all as specified and directed.
9S&F in repair 300 mm mild steel oridinary rat tail rod pattern springs including roller and roller plates, complete all as specified and directed.
10S&F aluminium alloy, sliding door bolt 300 mm long with hasp, staple ( bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, all as specified.
11S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples including fixing with beads, nut bolts, welding, etc and removal of old from wooden or mild steel frame as in repairs complete all as specified.
12Hacking out old broken glass (any thickness,size,quality or description) from wooden frames or stone concrete or brick surrounds,glazed with putty or fixed with beads, complete all as specified.
13S & F 3.0 mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5sqm in each pane, complete all as specified.
14Taking down cement plaster on brick or concrete surface and description including raking out joints Hacking for key scrubbing down with water, M&L Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement mixed with and including two coats of cement base paint over a coat of primer on newly plastered surface of wall including preparation of surface and curing after applying each coat complete all as specified and directed.
15Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for keys scrubbing down with water, M&LRendering 10mm thick in cement mortar 1:6 on fair aces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement including preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
16Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L non skidceramic coloured tiles7 to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
17Dismantling of wall tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L Glazed ceramic coloured tiles of size 450 x 300 x 7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4, all as specified and directed.
18Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L vitrified ceramic light shade tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm laid over 15mm thick screed bed in CM 1:6 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
19S&F 15 mm bore dia steel water tubing "medium grade" galvanised with all fitting (i.e. Tee, socket, bend etd) complete to walls and ceilings or laid in floors and taking up or down GI pipes 15mm bore and connection including cleaning for refixing or removal un-serviceabl pipe, complete all as specified and directed by Engr-in-Charge.
20S&F 20 mm bore dia steel water tubing "medium grade" galvanised with all fitting (i.e. Tee, socket, bend etd) complete to walls and ceilings or laid in floors and taking up or down GI pipes 20mm bore and connection including cleaning for refixing or removal un-serviceabl pipe, complete all as specified and directed by Engr-in-Charge.
21S&F in repair low level 10 ltrs capacity PVC valveless symphonic action type flusing cistern low level white with inlet ball valve float ovel handle including 32mm dia PVC flushing pipe complete all as specified and directed by Engr-in-Charge.
22M&L for disconnecting existing tank, setting side for reparing cleaning and removing all scale and dirt from tanks and from mouths circulating pipes and housing in same position of capicity upto and including 500 ltrs and endrosed the word " CLEANED WITH DATE" complete all as specified.
23S&F in repair bib taps, fancy type, chromium plated, cast copper aloy ISI marked with crutch or butter fly handle high pressure screwed down for iron pipe of 15mm bore complete all as specified and directed by Engr-in-Charge.
24S&F in repairs 15mm bore angle valve chromium plated screwed downfancy typehigh pressure screwd both ends for iron pipe of 15mm bore complete all as specified and directed by Engineer-in-Charge.
25S&F in repairs concealed type 15mm bore angle valve chromium plated screwed downfancy typehigh pressure screwd both ends for iron pipe of 15mm bore complete all as specified and directed by Engineer-in-Charge.
26S&F in repair brass chromium plated shower rose 75mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed.
27S&F in repair fancy type Pillar tap cast copper alloy chromium platedwith capstan heads screwed down high pressure or without lettered hot or cold with long screwed, shanked and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed.
28S&F in repair bib taps, standard of PTMT any colour high pressure screwed for iron pipe of 15mm bore complete all as specified and directed
29S&F in repair 20mm ball valve high pressure with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified.
30Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
31Dismantling of steel (Corrugated, semicorrugated, etc) sheets in roof coverings, M&L pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws. Sheet colour approved by Engineer-in-Charge complete all as specified and directed.
32Dismantling of steel (plain) sheets in roof coverings, S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding/ridges to wall, fixed with self tapping screws complete all as specified and directed.
33S&F roof trusses (framed), trussed, purlins, rafters rails and fastenings and heavy bracket framing (beem, tee, angle, channel or flat sections) including distance pieces, cleats etc of FE 410 W (Gde E-250) quality B including one shop coat of red oxide primer complete all as specified and directed.
34M&L PCC 1:5:10, type E-2, (using 40mm graded crushed stone aggregate) in foundation filling/sunken floor and mass concrete,all as specified.
35M&L for Preparing the new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified.
36Preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint/camouflaged pattern, complete all as specified and directed.
37Material & labour for one coat of cement base paint including preparation of old surface to match the shade as per colour scheme as approved by Engr-in-Charge.
38M&L for applying two coats of oil bound distemper on walls including preparation of old plastered surfaces complete all as specified.
39Demolition of cement concrete ( unreinforced) in ground floors and pavings n exe 15 cm thickness. ( below or above ground level) all as specified.
40M&L 75mm thick plain cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in Sub base/Plinth protectionall as spd and directed.
41S&F Cast Iron door closer hydraulically regulated desination No 1 universal type suaitable for door shutter up to 1000 mm in width and of weight not more then 35 kg, completeall as specified and as directed.
42S & F in position suspended anodised aluminium false ceiling system using E-grid suspended ceiling grid system. The size of grid shall be 605X605 mm fixed in the grid of E-grid suspended ceiling grid system duly suspended by 6 mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40X3 mm size long and expansion hold fasteners 12.5 mm dia 40 mm long and M&I for exposed metal frame ceiling with 6 mm thick calcium silicate boards of siliceous and calcareous materials reinforced with cellulose fibre for fixing in 600X600 mm grid (Expect frame work) complete all as directed and as approved by Engr in Charge and dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including fillets,Complete all as specified and directed by Engineer-in Charge.
43Taking down carefully aluminium / copper point wiring any type for one light , fan, socket power point controlled by one switch complete including fitting / fixtures such as switches, ceiling roses, holder, socket etc; and making good disturbed surfaces of walls, ceilings etc
44Material and labour for point wiring with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn through and includingrigid non metallic PVC concealed conduit (medium grade) of suitable dia along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and includingpressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover or cover plate of modular complete for mounting switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good disturbed surface all as specified and as directed for the following.
45One light/fan point controled by one 5/6 Amp piano type switch
46One 3 pin socket outlet 5 Amps on same board.
47One 3 pin socket outlet 5 Amps on indpendent board
48All as per item No 44here in before but point wiring with 2.5 sqmm FR multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board, complete all as specified and directed.
49Material and labour for point wiring with 1.5 sqmm (nominal area)PVC insulated and sheathedmultistranded copper conductorcable FRLSH 1100 volts gradedrawn in and includingPVC casing and capping of size 30/32 mmfixed to wall ceiling including PVC closed recessed boxes ISI markedwith 3.00 mm thick plastic laminated sheet top cover or cover plate of modular complete for mounting of switches, sockets etcincl1.50 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade single core earth continuity conductorconnected to common earth dolly all as directed and specified for the followings.
50One light /fan point controled by one 5/6 Amp piano type switch
51One 3 pin socket outlet 5 Amps on same board.
52One 3 pin socket outlet 5 Amps on indpendent board
53All as per item No 46here in before but point wiring with 2.5 sqmm FR multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board, complete all as specified and directed.
54S&F in replacement of switch piano (flush button type) single pole, one way, 5 Amps complete all as specified and directed.
55S&F in replacement of switch socket combination 2 in one, 3 pin , 5/6 Amps, 240 Volts flush type,complete all as specified and directed.
56S&F in replacement of switch socket combination 2 in one , 3 pin, 5/6/16 Amps flush type complete all as specified and directed.
57S&F in replacement of socket out let 2 in 1, 3 pin 5 Amps flush typecomplete all as specified and directed.
58S&F in replacement of modular switch single pole one way6 Amps 1 module complete all as specified and directed.
59S&F in replacement of modularsocket 6 A-2/3 pin combined 2 module complete all as specified and directed.
60S&F in replacement of modular switch single pole one way 16 Amps 1 module complete all as specified and directed.
61S&F in replacement of modularsocket 6 A/16 amp -2/3 pin combined 2 module complete all as specified and directed.
62S&F in replacement ofceiling rose polycarbonate typethree terminals complete all as specified and directed.
63S&F in replacement of step type electronic fan regulator 120 wattsingle pole 240 Volts complete all as specified
64S&F in replacement of modular fan regulator, electronic step type heavy duty modular 2 module230 volts, 120 watt complete all as specified and as directed.
65Supply and fix in replacement Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings,all as specified.
66S&F LED lamp,6500K,900lm in white colour of 9/10 Wattbase cap B-22 with poly carbonate difusser and aluminium heat sink ,complete all as specified & directed.
67S&F in replecement of fully diffused recessed mounted luminaire 2"x2" LED 36W, 6500 K suitable for POP/ gypsum false ceiling complete with hosing with all accessories pre-wired and making connection with threecore copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting including taking down old unserviceable luminaire, complete all as specified & directed. Make Philips Cat part No.RC370B LED36S-6500 G6 L60W60 PSU OD S6 or equivalent cat part of make as specified in list of make here-in-after.
68S&F in replecement of LED tubelight fitting 1x20Wattbattentype fitting4 feetlong aluminium extruded housingIP-20 ratedrated voltage 230 volts(operating range 140 volt to 270 volts) , 50Hzsystem wattage 20 Watt +/-10% ,system current not less than 102 mA ,power factor more than 0.95, systemlumen efficacy 100 lm /watt ,CCT 6500KCRI more than 80, THD less than 30%, driver efficiencymore than 85% complete all accessories prewired and connecting electrically to ceiling rose using PVC insulatedand overallsheathedflexible copper conductor of size 0.75 sqmm3 core all as specidfierd and directed. Make Havells Cat part No. LHEXARP7SN1W020 or equivalent cat part of make as specified in list of make here-in-after.
69S & F in replacement of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size
70S&F in replecement of plug top, AC 230 Volts, 16 Amps complete all as specified and directed.
71Supply in replacement of hylam sheet cover 3 mm thick for fixing switches,sockets, regulators etcof size 4 x 4 (Inches) on existing metal box complete all as specified and directed.
72Supply in replacement of hylam sheet cover 3 mm thick for fixing switches,sockets, regulators etcof size 7 x 4 (Inches) on existing metal box complete all as specified and directed.
73S&F in replecement of PVC conduit medium grade with fittings, ISI marked, 20 mm size complete all as specified and directed.
74S&F in replecement of PVC conduit medium grade with fittings, ISI marked, 25 mm size complete all as specified and directed.
75S&F in replecement of PVC casing & capping with fittings, ISI marked, 20X12 mm size complete all as specified and directed.
76S&F in replecement of PVC casing & capping with fittings, ISI marked, 25X16 mm size complete all as specified and directed.
77S&F in replecement of PVC switch boards, closed recessed suitable for surfaces, sizes 4 X 4 (Inches) complete all as specified and as directed.
78S&F in replecement of PVC switch boards, closed recessed suitable for surfaces, sizes 4 X 7 (Inches) complete all as specified and as directed.
79S&F in replecement of PVC switch boards, closed recessed suitable for surfaces, sizes 8 X 6 (Inches) complete all as specified and as directed.
80S&F in replecement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 6 Sq mm and one run of 6 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductordrawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 6 sqmm cable and one run of 6.00 sqmm earth wire with PVC casing and caping shall be measured as one unit.
81S&F in replecement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductordrawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 4 sqmm cable and one run of 4.00 sqmm earth wire with PVC rigid conduit shall be measured as one unit.
82S&F in replecement of 1100 volts grade heavy duty cable PVC insulated aliminium conductor served with inner sheathing of PVC sheathed with stranded conductor 10 sqmm twin core cable flat or circular, complete all as specified and directed.
83S&F in replecement of Sheet metal enclosure IP-43 double door for DBs(where MCBs arereqd) SPN 240 V, for 4 ways, complete all as specified.
84All as per item no 77above but SPN 8 ways 240 volts completeall as specified and directed.
85All as per item no 77 above but SPN 12 ways 240 volts completeall as specified and directed.
86Supply and fixing in replacementof MCB single pole 6 to 30 Amps, 10KA, 230 volts "C" series, complete all as specified and directed.
87S&F in replecement of MCB SPN 32/40 Amp, 240 volts 50Hz AC supply, "C" series,complete all specified.
88S&F in replecement of MCCB 63 Amp,4 pole, 16KA 415volts 50Hz, AC supply, complete all specified.
89S&F in replecement ofsheet metal enclosure for multi phase out going suitable for mounting 63 Amps FP MCCBs. Vertical distribution board 4 waysmountingas incommer with 200 Amp rated bus bar,IP- 42 Protection ,double door conceled/ wall mounting suitable for mounting MCBs/Isolators.all as specified and as directed.
90Deduction to be made from BOQ for schedule of credit (Sch "A" Part - II) Amount of ? 23,340.30during AOC Note:- Tenderers shall not quote for this Schedule
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail