Tender For Repair/Replacement Of Lt Cables, Mccbs Incl And Allied Works In North Area Under Age E/M Elect Supply At Ge(U) E/M Meerut Cantt, meerut-Uttar Pradesh

Military Engineer Services has published Tender For Repair/Replacement Of Lt Cables, Mccbs Incl And Allied Works In North Area Under Age E/M Elect Supply At Ge(U) E/M Meerut Cantt. Submission Date for this Tender is 08-06-2024. Electrification Work Tenders in meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43413710
Corrigendum : Tender For Repair/Replacement Of Lt Cables, Mccbs Incl And Allied Works In North Area Under Age E/M Elect Supply At Ge(U) E/M Meerut Cantt
Tender
Indian
Uttar Pradesh
Meerut
08-06-2024

Tender Details

REPAIR/REPLACEMENT OF LT CABLES, MCCB’S INCL AND ALLIED WORKS IN NORTH AREA UNDER AGE E/M ELECT SUPPLY AT GE(U) E/M MEERUT CANTT; 1 Supply, laying, jointing, testing and commissioning LT underground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098 (marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed by Engr-in Charge . Cables of the following sizes:-(Note;- Rate quotted includes terminal Lugs /road cutting/ wall cutting/ floor cuttingand making good damged portion matching with existing surface with all existing finishes.) 2 6 Sqmm 3 core 3 16 Sqmm 4core 4 25Sqmm 4core 5 35 Sqmm 3.5 core 6 50 Sqmm 4 core 7 70 Sqmm 3.5 core 8 95 Sqmm 3.5 core 9 120 Sqmm 3.5 core 10 185 Sqmm 3.5 core 11 240 Sqmm 3.5 core 12 300 Sqmm 3.5 core 13 Taking down old u/s LT UG Cable any core any size complete all as specified and directed 14 Taking down old u/s ACSR conductorany size complete all as specified and directed.(Note:- Some ACSR conductor shall be replaced with U/G cable as per site requirment) 15 Taking down mild steel cross arms etc complete all as specified and directed. 16 Taking out underground cable and relaying , jointing, testing and commissioning serviceable LT underground cables, 1100 volts grade any type and size complete all as specified and directed by Engr-in- Charge 17 Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and gettingout in Soft/Loose soilincluding trimming sides and bottom of trenches complete all as specified and directed. 18 Returning, filling-in, including spreading, watering and well ramming in layers notexceeding 25 cm thick each, in soft /loose soil complete all as specified and directed. 19 Removing excavated surplus soil to a distance not exceeding50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 20 Material and labour for riverwashed and screened, dry sand for filling in trenches below and around underground cablesfor cushioning of cables complete all as specified and directed. 21 M & L for fly ash bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm complete all as specified and directed. 22 Supply and laying galvanised steel water tubing, light grade, IS-1239 marked with all fittings (IS marked)and laid in trenches / under roads / in drains / fixed to poles/walls ( with required size flat iron clamp bolts, nuts and washers )pipesof the following sizes including taking out old u/s pipes. 23 50mm bore 24 80mm bore 25 100mm bore 26 M&L for auguring of hole suitable for passing 40mm to 100mmbore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any damage to existing cables of anytype shall be made good by the Bidder without any extra cost to department. 27 Taking out unsv pole PCC/ Steel tubular andSupplying, transporting to site, erecting, and fixing in position, steeltubular swaged and welded poles of Overall height 9 metres, type 410 SP-31, IS-2713 marked, with mild steel base plate (filletwelded to poles), pole cap / finial taper plug, bolts, nuts, washers etc,including painting on the outside with two coats of aluminium paint over a coat of red oxide primer on exposed surfaces and black bituminous paint on steel surface embeded in concrete and painting 03 nos band /strips with fluorescent , PO box red synthetic enamel paint ( 30 cm wide each) at a distance of 30 cm fromplinth block and numbering of poles, including the existing service line/ chanel/ street lights/JBs complete allied itemsshifting the new polecomplete all as specified and directed byEngr-in-Charge.(Note:- Poles shall be swaged and welded atmanufacturer’s factory and not at site. The inner surface shall be factory painted) 28 M&L for PCC (1:4:8)type D2 using 40 mm graded stone aggregate in foundation(below pole ) complete all as specified and directed. 29 M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate for foundation of stay assembly/struts/pole etc. (around the poles in pit) complete all as specified and directed. 30 M&L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate for coping /pedestal of poles including necessary form work, fair finishing to exposed surfaces using extra cement complete all as specified and directed. 31 Supply and fixing pre-fabricated MSstructural steel (IS marked) work consisting of channels / angles / other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting the steel surfaces with twocoats of synthetic enamal paint over one coat of primer complete all as specified and directed. 32 Material and labour for supply straining and stretching of aluminum conductor steel reinforced (ACSR), ISI marked, laid overhead onpoles, including binding and jointing the conductor with and including 14 SWG binding wire complete all as specified and directed. 33 M&L for provision of anti-climbing device, spikes type, in two halves made to shape to suit the cross section of the pole,fabricated out of MS bars (round, square and flat) welded to MS flat including nuts, bolts, washers etc including taking out old anti-climbing device complete all as specified and directed. 34 Supply and fix in repair danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed with mild steel clamps (made of 25x3 mm MS flat iron) nuts, bolts and washers etc for LT poles / pillar box etc with voltage and danger indiated in Hindi and English complete all as specified and directed. 35 Supply and fixing in replacement stay assembly for LT poles complete, comprising of galavanised steel stranded stay wire 7 / 3.15 mm, galvanished steel stay bow 400 x 14, galvanized steel rod 2150 mm long 16 mm dia with nut bolts and washers, steel plate 230 x 230 x 6mm thick , 2 nos thimbles , loop insulator size 65 x 90 mm clearance hole 16 mm including clamps and fixed to stay clamp complete all as specified. (Note :Rate quotedincludes Excavation, earth work and PCC ) 36 Supply and fix in replacement pin type insulator, porcelain, vitreous white, size 100mm height and 65mm dia, 1100 Volts grade, ISI marked, including one galvanised mild steel spindle, two Nos GI washers and one GI nut complete all as specified and directed. 37 Supply and fix in replacement shackle type insulator,ISI marked,porcelain,vitreous white, 1100 volts grade, ISI marked of size 90 x 75 mm, including galvanized mild steel strips 31x3 mm,washers, insulators bolts (12 mm dia), washers and nuts all as specified and directed. 38 M&L for plate earthing for sub station equipments complete with galvanisedmild steel plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically (in earth pit not less than3.5m below normal ground level) with the top edge of the earth plate at a depth not less than 2.75m below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipments etc at the other, earth strip encased in and including 40mm boreGIlight grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregateexcavation & earth work and RCCcover complete all specified and shown in electrical plate No 5 of SSR Pt-I. including taking out old u/s earthing material. 39 Supplying and fixing STRAIGHT THROUGH cable jointing Kit for 1100 V grade cable forcomplete with jointing material ( heat shrink type) and accessories suitable for 25 sqmm to 50sqmm 3.5/4 core XLPE armoured aluminkium conductor cable and testing aftre jointing complete all as specified and directed. 40 Supplying and fixing STRAIGHT THROUGH cable jointing Kit for 1100 V grade cable forcomplete with jointing material ( heat shrink type) and accessories suitable for 70 sqmm to 120sqmm 3.5/4 core XLPE armoured aluminkium conductor cable and testing aftre jointing complete all as specified and directed. 41 Supplying and fixing STRAIGHT THROUGH cable jointing Kit for 1100 V grade cable forcomplete with jointing material ( heat shrink type) and accessories suitable for 150 sqmm to 185 sqmm 3.5/4 core XLPE armoured aluminkium conductor cable and testing aftre jointing complete all as specified and directed. 42 Supplying and fixing STRAIGHT THROUGH cable jointing Kit for 1100 V grade cable forcomplete with jointing material ( heat shrink type) and accessories suitable for 240 sqmm to 300 sqmm 3.5/4 core XLPE armoured aluminkium conductor cable and testing aftre jointing complete all as specified and directed. 43 M&L for Cutting of worn-out / burnt aluminium cable terminal lugs from the HT/LT cable , crimping of new aluminium cable core and fixing with transformer/ Panel MCCB terminal/ FPB/ JB/ pole/DBs/ stud including cutting/ dressing of cable, disconnecting under ground / OH line cable conductor , cutting down worn-out portion and refixing with suitable lugs complete, includingunder ground cables of any type and size for repairs including taking out under ground cable loop from ground and making connections of restoration of electric supply complete all as specified. 44 Releasing the binding of ACSR conductor of OH lines from insulator , removing the jumper, connector, service wire, disconnecting the connection of UG cables and restretching of existing HT/LT OH lines ,any size, length and span upto desired sag as designed by Engineer-in-Charge and rebinding the ACSR Conductor on insulator , reconnecting the UG cable etc complete all as specified. (Note :- Distance between two consecutive poles (any No of conductors) shall be measured as one span.) 45 Trimming/ loppingbranches of treetouching to LT/HT OH lines / two pole structre/ 4 pole structre/ not exceeding 30 cm girth , shrub, vegetation, bushwood and saplings at least upto 3 M from outer edge of ACSR including removing of braches of trees etc. to a distance exceeding 100 m and not exceeding 150 M complete all as specified and directed.Note :- (i) Shutdown wherever required shall be taken in writtig from Engr-in-Charge.(ii) Distance between two consecutive poles shall be measured as one span. 46 M&L for preparation of old painted surfaces erected steel tubular swaged poles / Rails/Girder poles of LTover head line ( Except embedded portion) , 9/11 Mtr longincluding all MS work mounted on pole , earth protection & water pipe ( if exists) and providing one coat of aluminium paint and providing 05 Nos bands/ straps with Two coats of synthetic enamel paint ( black & yellow and Black and redwhite30 cm wide each)from top of plinth block and numbering of poleswith white synthetic enamel paint on yellow synthetic enamel piant ground(50mm wide and 100mm high letters) including encircling the letters or figures complete all as specified and directed. 47 Finding out faultin any size of cable, 1100V grade to 33000V with the help of FaultTesting Vanby disconnecting of cable from both sides and making connection after fault finding and repairs upto a length of 500m complete all as specified & directed.Note:- All the equipments, tackle, T&P, Fault finding/ testing Van etc shall be arranged by contractor at his own cost. The rate quoted by contractor shall deem to be included and nothing extra shall be allowed. 48 Taking down Existing unsv ACB any Size from any paneland S& F ACB 4 Pole, TMR Based 630A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, EFprotection,s along with Spreader terminalsand connectintion with Existing connection(Note :Rate quottedincludes terminal lugs )(Make : Siemens: / Legrand /ABB/ Schneider ) 49 Taking down Existing unsv MCCB any Size from any paneland S& F MCCB 4 Pole, TMR Based 500A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, EF protection,s along with Spreader terminalsand connectintion with Existing connection complete all as specified and directed. 50 Taking down Existing unsv MCCB any Size from any paneland S& F MCCB 4 Pole, TMR Based 400A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, EF protection,s along with Spreader terminalsand connectintion with Existing connection complete all as specified and directed. 51 Taking down Existing unsv MCCB any Size from any paneland S& F MCCB 4 Pole, TMR Based 350A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, EF protection,s along with Spreader terminalsand connectintion with Existing connection complete all as specified and directed. 52 Taking down Existing unsv MCCB any Size from any paneland S& F MCCB 4 Pole, TMR Based 250A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, EF protection,s along with Spreader terminalsand connectintion with Existing connection complete all as specified and directed. 53 Taking down Existing unsv MCCB any Size from any paneland S& F MCCB 4 Pole, TMR Based 200A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, EF protection,s along with Spreader terminalsand connectintion with Existing connection complete all as specified and directed. 54 Taking down Existing unsv MCCB any Size from any paneland S& F MCCB 4 Pole, TMR Based 160A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, EF protection,s along with Spreader terminalsand connectintion with Existing connection complete all as specified and directed. 55 Surface Dressing/Cleaning forLT panel / 2/4 pole structure area/ transformer plinth area / sub stationsurrounding area including removing of tree branches, small tree, plantsand bushes etc complete all as directed. 56 M&L for preparation of old painted surfaces cleaning by rubbing with wire brushes / knife on all side rusted area of existing LTpanel / Feeder pillar box / junction box and applying two coats of synthetic enamel paint ((approved colour) by spray gun over a coat of red oxide primer and making it absolutely good finished including repair using MS plain sheet of existing gauge & other steel members (as requed) and welding etc complete all as specified and directed. 57 M& L for aluminium Bus bar 1100 voltscapacityof various size ofAmps load capacity with colour code insulation making hole , nuts/ bolts/ washerswith fixed the existing LT panel board / FPB/ JBs / Transformer complete including removing unsv old bus bar all as directed by Engr-in-charge. 58 Taking out Unsv JBs/ FPB and Supply, installing, testing and commissioning, factory made and tested ,LT Panel(KIOSK) (FPB ), outdoor type, minimum size 900 x 800x 600mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated Aluminium bus bar (LxWxH)400 x 50x10 mminstalled on SMC/ porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm CRCA MS sheet and 40x40x4mm thick angle iron frame work,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,front opening type, with aprons for cable entry,with double door shutter and locking arrangement ,internal wiring with PVC insulated,stranded copper conductor, FRLS cables, IS-694marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 240 sqmm by drawing /digging out cable from loops in trenches out side the Bldg includingof necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable sizelugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board,All out going feeders shall be connectedandfixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back doorpillar box etc with voltage and danger indiated in Hindi and English complete all as specified and as directed byEngr-in-Charge , The scope of work includes the following: (NOTE:-LTPanel board should be as per IS/ICE 61439-part I&II Type Test certificates and Panel Builder should submit all Certificates before executing the job.) 59 MCCB 4 Pole, Thermal Magnetic Based 200 A, Breaking capacity 16KA, 415 V, 50 Hzwith OL, SC, EFprotection, -01 No along with Spreader terminals. 60 Incoming :- 61 Digital Amps/volt /PF meter 0-500 volts with selector switch - 01 No 62 Indicator lamp LED type (R, Y, B) complete with fuse -01 Set 63 S&Fservice main distribution (SMC JUNCTION BOX ) box minium inside size 395 x 235 x 150 with Bus bar 200 amps 4 pole for distribution of multiple nos of service connectios , (ISI marked )weather and moisture proof, nuts and bolted bus bar system, 200 Amps capacity complete incl removing unsv any type pole junction box all as specified and directed.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 28-05-2024 Revised BOQ and Schedule of credit BOQ 08-06-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
Refer document