Tender For Pf Of Aspirating Smoke Detection System With Heat Sensors For Lt Cables In Substations 4
Tender Value
8.22 Lakhs
Estimated cost
Bid Submission
25 May 2024
0 days left
EMD
16500
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
mohali → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Pf Of Aspirating Smoke Detection System With Heat Sensors For Lt Cables In Substations 4
BOQ
| Sl. No. | Item Description |
| 1 | Supply/ Installation/ Testing/ Commissioning of Short wave length laser-Based Absolute Smoke Detection Panel with 2 pipe inlets, upto 800 m2 coverage including false floor and false ceiling; Wide sensitivity range - 0.005%–20% obs/m; built inalarm levels; High efficiency aspirator; Clean air barrier optics protection; Easy to replace dual stage filter with built in memory; 7 Nos. ofinbuilt potential free relay outputs; supports linear pipe length of 70m per pipe (total 140m) or branched pipe up to 100m per pipe;supports 20 Nos. of Class A sampling points, Auto Learn for automatic setup of alarm threshold, Referencing &Event log; TCP/IP & Two Core Wire network connectivity built in for central monitoring & monitoring through Centralized software (Software License Separate)Approvals-UL, ULC, FM,EN 54,VDSMake: Wagner/ Edwards/Honeywell |
| 2 | Supply and erection of VESDA Power Supply. The power supply is providing operating power 24 to 27 volt, including battery backup, for the entire line of VESDA Aspirating Smoke Detectors. The VESDA Power Supply has been designed to power a single unit to multiple units depending on application needs. It provides 24 to 27 volt operating power to the VESDA system as well as a battery charger function that supervises and maintains the standby batteries. Relay outputs for connection to the general-purpose input for fault monitoring (230 Vac only) EN54-4 Compatible, Temperature compensated charging to maximize battery life. The job includes the cost of labour and other petty material required to complete the job to the entire satisfaction of Engineer in charge of the work.Make: Wagner/ Edwards/Honeywell. |
| 3 | Supply and laying ofUPVC (Unplasticised polyvinyl chloride) pipe 25 mm outer dia ofMake- ASTRAL/ Finolex/ Supreme. The pipe should have pressure of 33.7 kg/cm2 at 23° C. The pipe should be laid on the ceiling of the building with the help of suitable size of clamp. The job includes the cost of labour and other petty material required to complete the job to the entire satisfaction of Engineer in charge of the work. |
| 4 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 5 | 3 x 1.5 sq. mm |
| 6 | Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. |
| 7 | 25 mm |
| 8 | Supplying, installation, testing & commisssioning ofintelligent addressable programmable sounder complete asrequired. |
| 9 | P/f of zone microprocessor based Main panel (each zone accessing minimum 50 numbers units ) wall mounted type fabricated out of 1.2/1.6mm CRCA sheet, dust and vermin proof, powder coated , complete in all respect suitable for operation on 220V AC 50Hz, power supply and battery charger. The panel shall be ERTL/TAC/CE/LPCB approved, EN-54, IS:2189 compliant. Make : Agni/Edwards/GST. |
| 10 | Supply and erection of digital linear heat detector (68 deg. C), CE/RoHS compliant, UL approved,minimum bend radius 50 mm,ambient temperature range -40 to 121 deg C, max voltage rating 30Vac, 42Vdc, for early detection of fire and overheating conditions in electrical panels cabling. Make - System sensor/ Edwards/ Honeywell. |
| 11 | Supply and erection of end of line box LHS EOL connected with heat sensing cable. EOL shall be installed at end of LHS cable to check the continuity of cable, including all accessories. Make - System sensor/ Edwards/ GST/ Honeywell. |
| 12 | Supply and erection of modulator box for connecting with heat sensing cable, modulator shall be integrated with main panel,is microprocessor based start point device between LHS cable and main panel, it monitors LHS cable for continuity and over temperature fire signature resistance of sensor cable and generate alarm, dual alarm setting (Pre alarm and alarm), compatible withall panels.Make - System sensor/ Edwards/ Honeywell. |
| 13 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 14 | 25 mm |
| 15 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. |
AI Tender Summary
Tender Timeline
May 17, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedMay 25, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 27, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender