Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #43403568

Tender For Annual Rate Contract For Construction And Commissioning Of Bore Holes For Tube Wells Of 150 200 Mm Dia In Various Water Supply Schemes Of Division Shahpura District Shahpura By Dth Rigs On Single Responsibility Turn Key Basis

Issued by Government Departments · shahpura, Rajasthan
Tender Value
60 Lakhs
Estimated cost
Bid Submission
30 May 2024
0 days left
EMD
1.20 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
shahpura → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Annual Rate Contract For Construction And Commissioning Of Bore Holes For Tube Wells Of 150 200 Mm Dia In Various Water Supply Schemes Of Division Shahpura District Shahpura By Dth Rigs On Single Responsibility Turn Key Basis

BOQ

Name of Work: Annual rate contract for Construction and commissioning ofbore holes for tube wells of 150/200 mm dia in various water supply schemes ofDivision Shahpura by DTH rigs on single responsibility turn key basis
Sl. No. Item Description
1Construction of Tube Well up to 100 mtr. depthin all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe.
2Nominal bore 150 mm dia.
3Nominal bore 200 mm dia.
4Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
5Add 15% extra on above item (Item No 2.4.1 to 2.4.4) for drilling, where strata is collapsible and lowering of casing pipe is required . The work includes lowering of casing pipe, but excluding the cost of casing pipe. The rate shall be applicable for stretch of collapsible strata only.
6Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as per amended up to date.
7Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes
8150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m)
9200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)
10Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.
11150 mm dia
12200 mm dia
13Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.
14Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc.
153 core 4.0 Sq.mm
163 core 6.0 Sq.mm
173 core 10.0 Sq.mm
18Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
1910.0 Sq.mm, 4 core
2016.0 Sq.mm, 4 core
21Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
22Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
23Up to 5.5 KW (7.5 HP) & head above 120 mtr.
247.5 KW (10 HP) & head up to 120 mtr.
257.5 KW (10 HP) & head above 120 mtr.
269.3 KW (12.5 HP) & head up to 120 mtr.
279.3KW (12.5 HP) & head above 120 mtr.
2811 KW (15 HP) & head up to 120 mtr.
2911 KW (15 HP) & head above 120 mtr.
30Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer,phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system.The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level.The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
31Up to 5.00 HP
32Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
33Above 5 HP and up to 10 HP
34Above 10 HP and up to 15 HP
35Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
36Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
3732 mm dia
3850 mm dia
3965 mm dia
40Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect.
4140 mm dia
4250 mm dia
4363 mm dia
4475 mm dia
45Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.
4650 mm dia
4765 mm dia
48Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.
49Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes
5065 mm dia
5180 mm dia
52Proving and Fixing 32 mm dia Full way valve or wheel valve as per IS:778 or amended up to date of approved make, on pump delivery pipe.
53Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover.

AI Tender Summary

OUR REF NO 43403568
AUTHORITY Government Departments
TENDER VALUE 60 Lakhs
LAST DATE 30-05-2024
Authority
Authority Name Public Health Engineering Department
Work Description Annual Rate Contract For Construction And Commissioning Of Bore Holes For Tube Wells Of 150 200 Mm Dia In Various Water Supply Schemes Of Division Shahpura District Shahpura By Dth Rigs On Single Responsibility Turn Key Basis
Basic Detail
Tender No NIT No. 03/2024-25
Bidding Type Tender
Location
City shahpura
State Rajasthan
Key Dates
Publish Date 17 May 2024
Submission Date 30 May 2024
Open Date 30 May 2024
Finance
Tender Value 60 Lakhs
Tender Fee 2000
EMD 1.20 Lakhs
Exemption Available
Document List
Tendernotice_1.pdf
Tendernotice_2.pdf
c84dbf93-ef0a-4f16-8a03-6826229d05cf.html
BOQ_700002.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 17, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
May 30, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 30, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

html

c84dbf93-ef0a-4f16-8a03-6826229d05cf.html

xls

BOQ_700002.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders