Bharat Sanchar Nigam Limited-BSNL has published Tender For Attending Day To Day Maintenance And Breakdown Faults At Various Te /Bts On Call Basis Under Daltonganj Oa. Submission Date for this Tender is 25-05-2024. Telecommunication Services Tenders in ranchi Jharkhand. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 21-May-2024 | corrigendum reg Items in BOQ | Financial Bid | 25-05-2024 |
2 | 22-May-2024 | corrigendum regarding change in date | Date | 03-06-2024 |
3 | 22-May-2024 | corrigendum in technical bid | Technical Bid | 03-06-2024 |
Sl. No. | Item Description |
1 | Attending breakdown fault of service cable / power supply / breakage of cable / cleaning and tightening loose and restoration of power between JBVNL supply point to end points of power output . Checking & Mtce of power at following points as per site requirement. |
2 | JBVNL supply point to energy meter |
3 | Energy meter to Main switch / Change over |
4 | Main switch to Change over / Panel/D,Bs |
5 | DG set to Change over |
6 | Change over to Distribution board / Panel |
7 | Distribution board / Panel to Power Plant |
8 | Automatic voltage Input Output By-bass etc |
9 | Distribution board / Panel to Points of outputs. |
10 | a ) Within 50Kms distance from District head Quarter Ranchi |
11 | b ) Between 50-100Kms distance from District head Quarter Ranchi |
12 | c ) Above-100Kms distance from District head Quarter Ranchi |
13 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface/recessedmediumclassPVCconduit,withpianotype switch, phenolic laminated sheet, suitable sizeM.S. box and earthingthepointwith1.5sq.mm.FRLSPVCinsulatedcopper conductor single core cable etc. as required. |
14 | (a) Group- C |
15 | Wiring for circuit /sub main wirirng along the earth wire with the following sizes of FRLS PVC insulated copper conductor ,single core cable in surface /recessed medium class PVC conduit as required (Make - Polycab/Havells/SS ) |
16 | 2x1.5sqmm +1x 1.5 Sqmm earth wire |
17 | 2x4 sqmm +1x 4Sqmm earth wire |
18 | 2x6 sqmm +1x 6 Sqmm earth wire |
19 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required (Make - Polycab/Havells/SS ) |
20 | a) 1x1.5 Sqmm |
21 | b) 3x1.5 Sq mm |
22 | c) 6x1.5 Sq mm |
23 | c) 2x4 Sq mm |
24 | d) 4x4 Sq mm |
25 | e) 4x6 Sq mm |
26 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
27 | a) 20 Sq. mm. (ISI mark ) |
28 | b) 25 Sq. mm.(ISI mark ) |
29 | c) 25 mmx 16 mm UPVC casing & caping |
30 | Supplyingandfixingfollowingpianotypeswitch/socketonthe existing switch box/ coverincluding connections etc. as required. |
31 | a) 5/6 amps switch |
32 | b)15/16 Aswitch |
33 | c) 3 Pin 5/6 amp socket outlet |
34 | d) 6 Pin 15/16 A socket outlet |
35 | e)Fan Regulator (Electronic rotaryType ) Penta Step |
36 | f)brass batten/angle holderincluding connection etc as required |
37 | Supply and fixing of 3 pin 5A ceiling rose on the existing junction box/wooden block including connection etc as required |
38 | Supply and fixing metal box of 180mmx100mmx60mm deep (nominal size ) on surface or in recess with suitable size of phenoliclaminated sheet cover in front including provididng painting etc as required |
39 | Supply and fixing of 380mm exhaust fan and louvers suitable for 1 ph ,230volts,50Hz AC supply (Make : Crompton/Havells or similar superior make ) |
40 | Supplying and fixing of 30 watts 5700K LED street light on the existing pole with bracket suitable for 1Ph, 230volts, 50Hz AC supply i/cdismantling the faulty, old fitting and fixing the new one testing, commissioning etc., as required.- (Make : Philips/Crompton or similar superior make ) |
41 | Supplying and fixing of folowing electrical fittings suitable for 230V ,50Hz etc as reqd |
42 | a) 20watt LED tube light batten type fittings (Havells and SS make ) |
43 | b) 9 watt LED bulb Lamp (Havells or Similar superior Make ) |
44 | Supply and installation of 1200mm sweep ,50 watt min 370 RPM ,min air delivery 215CFM suitable for 230 V,50 Hz power supply as per site reqd . (Crmpton Entrust 50 or SS make ) |
45 | Repair & Rewindingof Ceilingfanincluding winding with appropriate gaugeof copper enamelled wire ,replacement of bush/bearing and greasing as per requirement |
46 | Supplying and fixing of folowing electrical fittings suitable for 230V ,50Hz etc as reqd |
47 | a) 20watt LED tube light batten type fittings (Havells and SS make ) |
48 | Supplyof following sizeUn Armoured Aluminium LTcable (WPTC ) on surface of wall / on existing pole with support / clamp as replacement of service cable etc as reqd . (Make -ISI Mark /Polycab) |
49 | a) 2X6 Sq. mm |
50 | Laying of onenumber PVC insulated and PVC Sheathed/ XLPE power cable of 1.1 KV gradeofsizeup to 35sqmm in thefollowingmanner as reqd. |
51 | a) Onwall surfaceasreqd (clamped with 1 mm thick saddle) / Hanging on existing pole with clamp/support |
52 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, refilling the trench but excluding sand cushioning, protective covering etc as required. |
53 | a) Upto 35 sq. mm |
54 | Transportation of differentcable ( 4X16 Sqmm / 31/2X25 Sqmm / 31/2X35 Sqmm)from ARTTC to various sites(BTS/Exchanges )including loading ,unloading under Ranchi OA( Cable Length upto 100 meter ) |
55 | a) within 30KMS |
56 | b) With in 100 kms |
57 | c) Within 200 Kms |
58 | Transportation of differentcable ( 4X16 Sqmm / 31/2X25 Sqmm / 31/2X35 Sqmm)from ARTTC to various sites(BTS/Exchanges )including loading ,unloading under Ranchi OA( Cable Length upto 300 meter ) |
59 | a) within 30KMS |
60 | b) With in 100 kms |
61 | c) Within 200 Kms |
62 | Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing as required. |
63 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
64 | a) 2X6 Sq. mm (19 mm) |
65 | b) 4X10 Sq. mm (25 mm ) |
66 | c) 4X16 Sq. mm (28 mm ) |
67 | d) 3 1/2 x25Sq.mm (28mm) |
68 | Supply and fixing following way ,horizontal type three pole and neutral ,sheet steel,MCB Distribution board 415V,on surface /recess,complete with tinned copper bus bar,din bar,interconnections,powder coated ,including earthing etc as required (But without MCB/RCCB/Isolator ) (Make -L&T /Havells/SS ) |
69 | a) 4 Way (4+12),Double Door |
70 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required (Make -L&T /Havells/SS ) |
71 | a) Single pole |
72 | b) Single Pole and Neutral |
73 | c) Double Pole |
74 | d) Triple Pole |
75 | e)Triple Pole and Neutral |
76 | Supply and fixing following rating,double pole ,240 V isolator in the existing MCBDB complete with connections,testing and commissioning etc as required |
77 | a) 40Amps |
78 | b) 63 Amps |
79 | Supply and fixing following rating,Fourpole ,415 V isolator in the existing MCBDB complete with connections,testing and commissioning etc as required |
80 | a) 40Amps |
81 | b) 63 Amps |
82 | Supplying and Fixing of following items after dismentling of existing faulty one . i/c disconnection of cable from faulty item and making connection with newitem testing etc on load as reqd. |
83 | a ) 63Amp 4-pole on load change over switch in sheet steel enclosure , front handle type (Make: HPL Socomec /Havells / L & T) . |
84 | b ) 100Amp 4-pole on load change over switch in sheet steel enclosure , front handle type (Make: HPL Socomec /Havells / L & T) . |
85 | c ) 63A, TPN, Switch Fuse Unit in sheet steel enclosure with 3 nos porcelain fuse links & neutral link (Make: L&T FN type, /Havells / L & T) |
86 | d) 100A, TPN, Switch Fuse Unit in sheet steel enclosure with 3 nos porcelain fuse links & neutral link etc as required(Make: L&T FN type, /Havells / L & T) |
87 | e) 63A,TPN MCB (Make:L & T/ Havells ) |
88 | f)100A, 4 Pole MCCB of 16KA breaking capacity withfixed thermal & fixed magneting setting in open execution (Make: HPL Socomec /Havells / L & T) |
89 | g) 63 Amp porcelainfuse unit with base & carrier.(Make -ISI ) |
90 | h )100Amp porcelainfuse unit with base & carrier.(Make -ISI ) |
91 | Replacement of 1 phase, 2 wire 240 V AC Static watt hour meter direct reading 5-30A Accuracy Class 1.0approved byJBVNL discom specification /meter standards, testing through MRT and liasoning for installation testing on load etc as reqd. (With Enclouser)Make : Secure/L&T /similar superior make ) |
92 | Replacement of 3 phase,4 wire 415V AC Static watt hour meter direct reading 10-60A Accuracy Class 1.0approved byJBVNL discom specification /meter standards, testing through MRT and liasoning for installation testing on load etc as reqd (With Enclouser) Make : Secure/L&T /similar superior make ) |
93 | Total amountwithout GST |
94 | Total GST amt(Sum of GST of each item as per applicable GST rate i.e. 18% ,28%) |
95 | (i/c GST) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy