Tender For Repair/ Maintenance Of Over Head Tanks, Earthing, Lighting Conductor, Aviation Lights And Misc Works Under Age E/M-Ii Of Ge(N) Mamun, mamun-Punjab

Military Engineer Services-MES has published Tender For Repair/ Maintenance Of Over Head Tanks, Earthing, Lighting Conductor, Aviation Lights And Misc Works Under Age E/M-Ii Of Ge(N) Mamun. Submission Date for this Tender is 03-06-2024. Electrification Work Tenders in mamun Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43370968
Corrigendum : Tender For Repair/ Maintenance Of Over Head Tanks, Earthing, Lighting Conductor, Aviation Lights And Misc Works Under Age E/M-Ii Of Ge(N) Mamun
Open Tender
Indian
Punjab
mamun
03-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair/ Maintenance Of Over Head Tanks, Earthing, Lighting Conductor, Aviation Lights And Misc Works Under Age E/M-Ii Of Ge(N) Mamun

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-06-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

Attachment

FileName File Description File Size
733b7d0f-b94a-4ed8-8973-540653a66afe.html Tender Notice 0 KB
BOQ_731754.xls Tender Document 0 KB
SampleofMOU.pdf Tender Document 0 KB
Tender.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: REPAIR/ MAINT OF OVER HEAD TANKS, EARTHING, LIGHTING CONDUCTOR, AVIATION LIGHTS AND MISC WORKS UNDER AGE E/M-II OF GE(N) MAMUN.
Sl. No. Item Description
1Note for item No. 2.00 to 8.00 :- The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :- (a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer ofthe materials like Exterior Emulsion paint, putty etc after approval by the GE. (b) The Contractor shall upload with the documents under cover I "Memoradum of Understanding" (MOU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be laible to be rejected. (c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures. (d) Removing of Nails, making good holes, cracks etc (e) Work in patches and in narrow / widths, bands, cornices, pilasters etc and cutting in edge of line where necessary. (f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes. (g) Washing floors, cleaning glass, joinery , electric fittings , wirings etc. Drops and splashes of paint shall be cleaned to the entire satisfaction of Engineer-in-Charge. (h) Sample patch of 10Sqm shall be prepared considering all the items each of periodical, got the same approved from the GE before execution of work. No work shall be executed untill unless the sample patch is approved. (j) The work found not in confirmity to approved sample patch shall be rejected by the Engineer in Charge/ GE and shall be redone by the contractor without any extra cost.
2(a)Complete removal of existing treatment on Over Head Water Tank of capacity 150000 gallon by scrapping with mechanical sander (having mechanical vaccum mechanism with internal dust extraction system for clean environment certified by paint manufacturer) having RPM not less than 1500, sanding pad of 80 grit having dia of7" /9" to make surface free from dust, loose paint etc complete all as specified and directed. Note: The work shall be got done through skilled workmen with proper masking on face to avoid enhaling of dust during execution of work.(b)M&L for water proof cement based putty @ 1 kg (undiluted) per Sqm of average thickness 1mm over the plastered/ old prepared surface of wall,sanding of putty surface with mechanical wall sander (having mechanical vaccum mechanismwith internal dust extraction system for clean environment certified by paint manufacturer) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface smooth, clean, free from dust etc using following steps complete all as specified and directed:- Step 1 :- Mix the putty powder by adding water as per manufacturer"s instruction, mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2 :- Apply the first coat of the prepared mixer with the help of fully automatic airless spray machine of putty application finishing the surface even and smooth in level without any undulations. Step 3 :- Allow 6-8 hrs time to dry the putty surface. Note: The work shall be got done through skilled workmen with proper masking on face to avoid enhaling of dust during execution of work.
3(c) M&L for one coat of acrylic water based exterior grade primer @ 0.9 litre (undiluted)/ 10sqm diluted with water in 1:1 ratio,applied with fully automatic airless spray machine and allow 6-8 hours to dry the surface for painting of subsequent coats complete all as specified and directed.(d) M&L for water based premium acrylic smooth exterior emulsion of approved colour with silicon additive excellent dirt pickup resistance with low VOC less than 50, antifungal / anti algai properties in two coats @ 1.79 litre (undiluted) / 10 Sqm diluted with water as per manufacturer"s instruction applied over primed surface with fully automatic airless spray machine of paint application with a flow speed of minimum 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in between 1st and subsequent coats of paint complete all as specified and directed.
4All as per srl item No. 2.00 & 2.01 but for Over Head Tank of capacity 100000 gallon
5All as per srl item No. 2.00 & 2.01 but for Over Head Tank of capacity 75000 gallon
6All as per srl item No. 2.00 & 2.01 but for Over Head Tank of capacity 50000 gallon
7All as per srl item No. 2.00 & 2.01 but for Over Head Tank of capacity 25000 gallon
8All as per srl item No. 2.00 & 2.01 but for Semi Under Ground Sump of capacity 100000 gallons
9All as per srl item No. 2.00 & 2.01 but Semi Under Ground sump of capacity 50000 gallons
10M&L for plastering 15mm thick in CM 1:4 external layer shall be mixed with liquid water proofing compound as per manufacturer"s instructions on brick work or concrete surfaces or in chajjas/parapet walls etc, surface finished even and smooth using extra cement including taking down existing plaster of any description and removal of rubbish complete all as specified and directed. Note : WPC will be measured and paid separately.
11Supply only liquid water proofing compound, complete all as specified and directed.
12Writing letter or figures (Block, Roman, Italic or Indian) n exc 30 cm high complete. The colour of paint and dimension of letter shall be used as approved by the Engr-In-Charge.
13Writing Stops, commas, short lines, dashes, hyphens, brackets etc. The colour of paint and dimension of characters shall be used as approved by the Engr-in-Charge.
14M&L for preparing old painted steel and iron surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
15M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected by25X4 mm GI strip as earth leadby means of nuts and bolt, thimbles, check nuts, washers of GI or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20 mm graded stone aggregate with fairfinish, internal surface of concrete chamber shall be given internal dia 300mm x 300 mm dia,15 mm thick plaster in CM 1:4 funnel with wire guage mesh ,80 mm thick RCC pit cover 320mm x 320 mm of RCC 1:2:4 Type B1 using 20 mm graded stone aggregatereinforced with XPM jally.Charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part -1 (1991) and specified including provision of GI strip upto 7.5 metre long protected by 40 mm dia light grade pipe and watering pipe shall be 20 mm bore medium grade ,including all excavation and earth work and connecting the earthing to an earthing test point andto mainswitch board as specified and testing on completion complete all as specified and directed. Note: RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover.
16S & F in repairs galvanised iron strip 25×4 mm buried in ground/ fixed on walls/ceiling by using suitable size GI saddles etc., complete all as specified and directed.
17M & L air termination, single pointed aluminium rod 12mm dia & 300mm long, complete all as specified and directed.
18M & L test point terminal block made of gun metal or phosphorus bronze size 75×75×25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex. Head screw all as specified and directed
19Demolition of cement concrete (unreinforced) or tiling etc. in ground floor and paving n.exc 15 cm thick (below or above ground level) and removal of rubbish beyond MOD land complete all as specified and directed.
20M&L 60mm thickness M-35 grade machine pressed precast concrete factory made pre-laminated glossy coloured interlocking paver block any shape & conforming IS 15658-2006 including 50mm thick sand cushioning, complete all as specified and directed.
21M&Lcement concrete type D2 1:4:8 (40mm graded crushed stone aggregate) as in sub floors, sub bases floors and pavings etc., complete all as specified and directed.
22M&L forPCC 1:2:4 Type B1 (using 20 mm graded crushedstone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, benching, copings, kneelers, apex stones, bed plates, kerbs , fillet, gola, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
23Supply and fixing aviation obstruction light on top of Overhead tanks yellow painted die-cast aluminium alloy housing integral LED aviation light including making electrical connection and testing complete all as specified and directed.
24Supply & fixing sheet metal enclosure MCB distribution board single pole & neutral 240 volts 2 way with 200 Amps without busbar, IP-43 IK-09 protection single door, complete all as specified and directed.
25S&F ofMCB SPN 20-40A ,10KA, 240 V "C" series complete with connections all as specified and directed.
26S & F weather proof PVC flat twin core aluminium conductor of size 10 sqmm 2 core including draw in pvc conduit complete all as specfied and diredted.
27Deduct Total amount of SCHEDUL "A" SECTION-II (SCH OF CREDIT) Rs 6,600.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail