Sl. No. | Item Description |
1 | Taking down carefully existing unserviceablealuminum/copperpoint wiring (light, fan, socket or power) of any description & in anyposition complete including all fittings& fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etcincluding taking out and removing serviceable fittings/fixtures and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed |
2 | M&L for point wiring with using 1.5 Sqmm (nominal area)with multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade , ISI -694 marked with valid CML Noin and including medium grade, PVC concealed conduit in stone masonry of any thickness of dia not less than 20 mm and conduit accessories, ISImarked with valid CMLno (IS-9537-19 for conduit and IS :3419:19765 for conduit accessories )concealed in wall with mild steel/ pressed steelmodular sunken box (with earth dolly) of1.6mm thick of suitable size, duly painted withtwo coatsofanti corrosive paint/aluminium paintovera coat of red oxide primer externally covered with modular coverand plate for fixing of modular switch,socket etc including PVC insulated multi stranded copper conductor to commom earth and connecting to earth dolly complete all as specfied and dirctedfor the following:- NOTE :- 1. The complete wiring installation shall be carried out in accordance and conformity with IS 732:1989 "code of practise for electrical wiring(latest version). 2. The unit rate aganist item of PVC concealed conduit point wiring includes for MS pressed steel sunken box for modular wiring GI sunken box duly painted with two coats of anti corrosive paint/black bituminous paint externally and two coated of aluminium paint over a coat of red oxideprimer internally for fixing switches,regulator, socket outlet etc with modular plate & box ISIS marked. 3.All screws,fasteners ,bolts,nuts & washer etc shall be of cadmium plated, The cost of which deemed to be included in the unit rate. 4.The complete wiring installtions shall be tested on completion as specfied in particular specfications. 5.The cutting/leaving , forming chases shall be done with electric cutter. 6.Cutting chases in stone masonry wherever shall be deemed to be included inunit rate. 7.The completed wiring Quoted rate shall be deemed to include the making good the disturbed surface for concealed withCM 1:4cement motor including finishing the surface to match with the existing surface. 8.Fittings likemodular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A". |
3 | One light/buzzer/fan point controlled by one; one way switch. |
4 | One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch. |
5 | One 3 pin socket out let 5 amp point on the (same board) with other switches. |
6 | All as per item No. 2 here-in-before butwith 2.5sq mm size FRLS single core pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor and 2.5sqmm PVC insulated and unsheathed cable 1100 volts grade with multistrand copper conductor as earth wire for3 pin socket outlet 15 amp on independent board. (only one point per circuit) |
7 | M&L for point wiring with using 1.5 Sqmm (nominal area)with multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade , ISI -694 marked with valid CML Noin and including medium grade, PVC concealed conduit in cement brick masonry and in wall of any thickness of dia not less than 20 mm and conduit accessories, ISImarked with valid CMLno (IS-9537-19 for conduit and IS :3419:19765 for conduit accessories )concealed in wall with mild steel/ pressed steel sunken box (with earth dolly) of1.6mm thick of suitable size, duly painted withtwo coatsofanti corrosive paint/aluminium paintovera coat of red oxide primer externally covered with modular coverand plate for fixing of modular switch,socket etc including PVC insulated multi stranded copper conductor to commom earth and connecting to earth dolly complete all as specfied and dirctedfor the following:- NOTE :- 1. The complete wiring installation shall be carried out in accordance and conformity with IS 732:1989 "code of practise for electrical wiring(latest version). 2. The unit rate aganist item of PVC concealed conduit point wiring includes for MS pressed steel modularsunken box for modular wiring GI sunken box duly painted with two coats of anti corrosive paint/black bituminous paint externally and two coated of aluminium paint over a coat of red oxideprimer internally for fixing switches,regulator, socket outlet etc with modular plate & box ISIS marked. 3.All screws,fasteners ,bolts,nuts & washer etc shall be of cadmium plated, The cost of which deemed to be included in the unit rate. 4.The complete wiring installtions shall be tested on completion as specfied in particular specfications. 5.The cutting/leaving , forming chases shall be done with electric cutter. 6.Cutting chases in brick/cementmasonry wherever shall be deemed to be included inunit rate. 7.The completed wiring Quoted rate shall be deemed to include the making good the disturbed surface for concealed withCM 1:4cement motor including finishing the surface to match with the existing surface. 8.Fittings likemodular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A". |
8 | One light/buzzer/fanpoint controlled by one; one way switch. |
9 | One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch. |
10 | One 3 pin socket out let 5 amp point on the (same board) with other switches. |
11 | All as per item No. 3 here-in-before butwith 2.5sq mm size FRLS single core pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor and 2.5sqmm PVC insulated and unsheathed cable 1100 volts grade with multistrand copper conductor as earth wire for3 pin socket outlet 15 amp on independent board. (only one point per circuit) |
12 | M&L for point wiring with using 1.5 Sqmm (nominal area)with multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade , ISI -694 marked with valid CML Noin and including medium grade, PVC casing caping and it connected accessories, ISImarked with valid CMLwith modular sunken boxexternally covered with modular coverand plate for fixing of modular switch,socket etc including PVC insulated multi stranded copper conductor to commom earth and connecting to earth dolly complete all as specfied and dirctedfor the following:- NOTE :- 1. The complete wiring installation shall be carried out in accordance and conformity with IS 732:1989 "code of practise for electrical wiring(latest version). 2. The unit rate aganist item of PVC concealed conduit point wiring includes for MS pressed steel sunken box for modular wiring GI sunken box duly painted with two coats of anti corrosive paint/black bituminous paint externally and two coated of aluminium paint over a coat of red oxideprimer internally for fixing switches,regulator, socket outlet etc with modular plate & box ISI marked. 3.All screws,fasteners ,bolts,nuts & washer etc shall be of cadmium plated, The cost of which deemed to be included in the unit rate. 4.The complete wiring installtions shall be tested on completion as specfied in particular specfications. 5.The cutting/leaving , forming chases shall be done with electric cutter. 6.Including removing old unservicable wiringand finishing the surface to match with the existing surface. 7.Fittings likemodular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A". |
13 | One light/buzzer/fanpoint controlled by one; one way switch. |
14 | One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch. |
15 | One 3 pin socket out let 5 amp point on the (same board) with other switches. |
16 | All as per item No. 4 here-in-before butwith 2.5sq mm size FRLS single core pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor and 2.5sqmm PVC insulated and unsheathed cable 1100 volts grade with multistrand copper conductor as earth wire for3 pin socket outlet 15 amp on independent board. (only one point per circuit) |
17 | Supply and fix in repairceiling rose surface bakelite , three terminals, 230V AC with polycarbonate body complete all as specifiedanddirected. |
18 | Supply and fix in repair modular switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge. |
19 | Supply and fix in repairmodular switch 16 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge. |
20 | Supply and fixin repair modular bell switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge |
21 | Supply and fix in repair modular socket, 6 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge |
22 | Supplyand fixin repairsocket modular , 6 /16 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge |
23 | Supply and fix in repair modular fan regulator 120 W 2 module complete all as specified and directed by Accepting officer |
24 | Supply in repairs earth plug and socket, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 voltswith and including one MCB, SP, 20A, 240 Volts as per all as specified and directed. |
25 | Supply and fix in multi musicding dong AC 230 Volt single pole complete as specified. |
26 | Supply and fixin repair lamp holder PVC / Polycarbonate typesuitable for LED lamp fittingincluding LED 9watt bulb complete all as specified and directed by Engr-in-charge |
27 | Supplyand fix in repairLED 20 W high quality indoor batten type tube light fitting with PC housing and as well light application , electrical connection of three core 0.5 sqmm copper flexible connection from ceiling rose to tube light fitting and with proper square box for fitting of tube light fitting complete all as specified and directed by Engr-in-charge Note:Fittings shall be selected as per the requirment of "K" value between2200 to 6500K. |
28 | Supplyand fix in repairLED 10 W high quality indoor batten type tube light fitting with PC housing and as well light applicationelectrical connection of three core 0.5 sqmm copper flexible connection from ceiling rose to tube light fitting and with proper square box for fitting of tube light fitting complete all as specified and directed by Engr-in-charge Note:Fittings shall be selected as per the requirment of "K" value between2200 to 6500K. |
29 | Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & Fsheet metal enclosure powder painted forMCB DB SPN08 way double door with IP-42 protectionwith Din rail and busbar complete all as specified and directed by accepting officer |
30 | Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & Fsheet metal enclosure powder painted forMCB DB SPN04 way double door with IP-42 protectionwith Din rail and busbar complete all as specified and directed by accepting officer |
31 | Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & Fsheet metal enclosure powder painted forvertical type MCB DB TPN04 way double door with IP-42 protectionwith Din rail and busbar complete all as specified and directed by accepting officer |
32 | Taking down carefully MCBs, metal clad plug, distribution boards/main switches of any type and size and Supplying and fixing sheet metal enclosure powder painted for MCB DB vertical type TPN 4 way double door with dinrail and busbar with IP-43 protection with door earthing and isolated neutral bar and insulated busbar assembly includingMCCB of 100 Amps complete all as specified and directed by Engr-in-charge |
33 | Supply & Fix in repairMCB TPN, 63 Amps in `C’ series having current rating 10 KA complete all as specified and directed. |
34 | Supply & Fix in repair MCB SPN, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed. |
35 | S&Fin repair MCB single pole, 6 to 32 Ampsin `C’ series having current rating 10 KA complete all as specified and directed |
36 | Taking Down Old Unserviceable Submain wiring complete including all accessories and making good the disturbed surfaces all as specified and as directed. |
37 | M/L for Sub main wiring with 2 runs of PVC insulated unsheathedmulti stranded single core copper conducter 6 Sqmm drawn throughPVCconcealed conduit in stone masonry/brick masonry including accessaries with 6sqmm PVC insulatedearth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiringand connecting up ,all as directed. Note: 2 runs of cable and one run earth wire and concealed PVCconduitwill be measured as one length. |
38 | M/L for Sub main wiring with 4 runs of PVC insulated unsheathedmulti stranded single core copper conducter 6 Sqmm drawn through PVC conduit/casing capping including accessaries with 6 sqmm PVC insulatedearth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiringand connecting up ,all as directed. Note: 4 runs of cable and one run earth wire and conduit/Casing & Caping will be measured as one length. |
39 | M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle completeall as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ |
40 | Supply only LED 20 W high quality indoor batten type tube light fitting with PC housing and as well light application, electrical connection of three core 0.5 sqmm copper flexible connection from ceiling rose to tube light fitting and with proper square box for fitting of tube light fitting complete all as specified and directed by Engr-in-charge Note:Fittings shall be selected as per the requirment of "K" value between2200 to 6500K., |
41 | Supply onlyLED 10 W high quality indoor batten type tube light fitting with PC housing and as well light application electrical connection of three core 0.5 sqmm copper flexible connection from ceiling rose to tube light fitting and with proper square box for fitting of tube light fitting complete all as specified and directed by Engr-in-charge Note:Fittings shall be selected as per the requirment of "K" value between2200 to 6500K., |
42 | Supply only fanregulator electronic, step type, socketnon modular suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified anddirected. |
43 | Supply only lamp older PVC / Polycarbonate type suitable for LED lamp fitting complete with LED bulb 9Wall as specified and directed by Engr-in-charge |
44 | Supply onlyBell push, flush type 5 AMPAC 230 Volt single pole complete as specified. |
45 | Supply only socket outlet five pin, 5 Amps, flush type, 230 volts AC circuit, as per model at sitecomplete all as specified anddirected. |
46 | Supply only switch socket outlet combination, multipurpose, three pin, 15 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit as per model at site complete and 4 holes on corner all as specifiedanddirected. |
47 | Supply onlyswitch flush type, 5/6 Amps, single pole, one way, 230 volts AC circuit complete all as specified anddirected. |
48 | Supply only switch socket outlet combination, multipurpose, three pin, 5/6 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit complete and 4 holes on cornerall as specifiedanddirected. |
49 | Supply only mutimusic buzzer , ding dong AC 230 Volt single pole complete as specified. |
50 | Supply and laying Rigid non-metallic PVC conduitbut inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts,saddles, pipe hooks etc of size 25mm dia including drawing cable, wire through PVC conduit complete all as specified and directed by Engr-in-charge |
51 | Supply and laying Rigid non-metallic PVC flexiableprotected corrugated conduit of size 20mm for loose wire near DB including drawing wire through conduit complete all as specified and directed by Engr-in-charge |
52 | Supply and laying in repiar ofPVC casing and caping but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts,saddles, pipe hooks etc of size 25mm dia including drawing cable, wire through PVC casing capping complete all as specified and directed by Engr-in-charge |
53 | M&L for repair/replacementto internalwiring fittings and fixtures such as lightfittings, sockets, switches and bell etc in any typeand capacity &in any position including replacing unserviceable item or replacing whole fixture, fittings in internal electrification , fault finding in wiring, tightening of loose connection, in case any fittings and fixtures found faulty sahll be replaced through appropriate items asmentioned here-in-before/ here-in-aftercomplete all as specified and directed Note 1 :Theitems should be paid separately under itemNo.42 to 51and 59 to 61 Note 2: Labour charges for replacing itemNo.42 to 51and 59 to 61 shall be demmed to be included in this item. |
54 | supply only 9W LED bulb all as specified and directedby Engr-in-charge. |
55 | Supply onlyceiling rose surface bakelite , three terminals, 230V AC with polycarbonate body complete all as specifiedanddirected. |
56 | Supply only modular switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge. |
57 | Supply only modular switch 16 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge. |
58 | Supply onlymodular bell switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge |
59 | Supply onlymodular socket, 6 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge |
60 | Supplyonlyswitchsocket modular , 6 /16 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge |
61 | Supply onlymodular fan regulator 120 W 2 module complete all as specified and directed by Accepting officer |
62 | supply only 15A Top suitable for exsiting board complete all as specified and directed by Accepting officer |
63 | supply and fix in repairplastic Modular surface mounted switch board of1 module including modular front , back plate and plastic suken box all as specified and directed |
64 | All as per above item No 51 but of 2 module |
65 | All as per above item No 51 but of 3 module |
66 | All as per above item No 51 but of 4 module |
67 | All as per above item No 51 but of 6 module |
68 | All as per above item No 51 but of 8 module |
69 | All as per above item No 51 but of 10 module |
70 | Supply only MCB TPN, 63 Amps in `C’ series having current rating 10 KA complete all as specified and directed. |
71 | Supply onlyMCB SPN, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed. |
72 | S&F onlyMCB single pole, 6 to 32 Ampsin `C’ series having current rating 10 KA complete all as specified and directed |
73 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) |
74 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m |
75 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc. |
76 | Supply and fix PVC plastic MCB Box 2 way indoor PVC MCB enclosre box |
77 | Supply in repairs earth plug and socket, triplepole, neutral sheet metal enclosures with a fourpin, plug and socket 20Amp, 415Vvoltswith and including TPN MCB , 20A, 415 Volts as per all as specified and directed. |
78 | Supply and fixing in replacement of LED Bolard new generation ,energy saving, environmental friendly , long life aesthetically designed aluminum landscape for diffused lighting with high power LEDs,IP65 protection and impact of capacity 20 Wattcomplete all as specified and directed. Note:Fittings shall be selected as per the requirment of "K" value between2200 to 6500K., |
79 | Supply only LED spot (recessed) white light15 W round type AC 90 - 260 volts including all accessories and fixing arrangement complete all as specified and directed Note:Fittings shall be selected as per the requirment of "K" value between2200 to 6500K., |
80 | Supply only LED spot (recessed) white light 12 W round type AC 90 - 260 volts including all accessories and fixing arrangement complete all as specified and directed Note:Fittings shall be selected as per the requirment of "K" value between2200 to 6500K., |
81 | Supply only LED spot (recessed) white light 6 W round type AC 90 - 260 volts including all accessories and fixing arrangement complete all as specified and directed Note:Fittings shall be selected as per the requirment of "K" value between2200 to 6500K., |
82 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light,6000Kcomplete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core 0.5 sqmm flexible copper conductor cases of suitable size complete all as specified and directed. |
83 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light,3000Kcomplete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core 0.5 sqmm flexible copper conductor cases of suitable size complete all as specified and directed. |
84 | Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flate 3 corecable of size 6 Sqmmcomplete all as specified and directed. |
85 | Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flate 3 corecable of size 10 Sqmmcomplete all as specified and directed. |
86 | M&L for threecore PVC insulated sheathed(heavy duty) unarmoured copperconductor multi stranded cable (for phase,neutral and earth ) of size 2.50 Sqmm for connection drawing through PVCincluding heavy duty PVC conduit of size 20mm dia,fiitingpvc,lugs /thimblesaccording to size of cable, clamping properly, buring cable/conduitin soil complete all as specified and directed. |
87 | Supply and fixing in replacement ofpost top lantern LED type of capacity 20 Watt 230 Volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact as per manufacture recommendationandcorrosion resistant complete with driver and lamp all as specified and directed. Note:Fittings shall be selected as per the requirment of "K" value between2200 to 6500K., |
88 | Supply and fix PVC plastic MCB Box 4 way indoor PVC MCB enclosre boxcomplete all as specified and directed. |
89 | Supply and fixing LED strip for flexiable profile lighting application with uniformity of light for perfect ambiance IP 65 all as specified and directed by Engineer-in-charge. Note:Fittings shall be selected as per the requirment of "K" value between2200 to 6500K. |
90 | Supply and fix decorative wall mounting antic brass finish feature with opal glass diffuser suitable for 7.5W A60 LED filament lamp E 27 base with lamp complete. Note:Fittings shall be selected as per the requirment of "K" value between2200 to 6500K. |
91 | Supply and fixing bed side reading light, LED lamp, wall mounted, Flexible, Roatable ,ultra slim and fancy body, focus lamp for multiple usage complete. |
92 | (1) The contractor shall keep all items readily available at site, which is required for urgent repair works. |
93 | (2) Common miscellaneous material such as screws any type, nails, washers, insulation tapes, clamps, hooks, which are required for the work the cost of which is deemed to be included in quoted rate. |
94 | (3) All tools &tackles, plants, machineries, equipment and material to carry out the work at site which is to be decided by GE (A) Bhuj shall have to be provided by the contractor at his/ her own cost. |
95 | (4) Contractor’s supervisor (electrical engineer) should be available at the site to supervise the works and co-ordinate with the officials. |
96 | (5) The manpower shall be issued identity card after getting due verification. Uniform should be worn by the manpower having monogram of the firm. |
97 | (6) The skilled worker should be facilited with mobile phone to contact on urgent tasks & their numbers should be displayed at various places and forwarded to administration. |
98 | (7) The contractor shall ensure safety of his workers and other at site of work and shall be responsible for any consequence arising out of execution of the repair and maintenance works. |
99 | (8) The date of repair, unit name & serial number shall be mentioned in neat sticker in the appliances after repair. |
100 | (9) Contractor is to collect the faulty appliances from units & return them after repair within a week. No separate charges shall be given for transportation. |
101 | (10) It is responsibility of contractor to clean the area after repair work of appliances. Rates are deemed to be include in his quoted rates of respective items. |
102 | (11) The same nature of complaints in same location/block shall be counted as one complaint in internal electrification. Job card and complaint register for entry of complaints shall be provided at his/ her own cost. |
103 | (12) The contractor provide test certificate of material to be incorporated in the work. |
104 | (13) Contractor shall carry out all test. The equipments shall conform to Indian standards. 1) IR test. 2) Polarity test. 3) Earth Resistance test etc. The test report after completion testing shall be submitted to the department with duly signed by licensed electrican following current leakage/any fault in wiring. The report shall be givenwith proper format showing each circuit value of test done. Equipment to be used in testing should be calibrated, date of calibration to be displayed on the equipmentand calibration report should be submitted. |
105 | (14) Contractor shall identify the real cause of fault of wiring . wiring problems that are identified should be documented. |
106 | (15) Work diary & hindrance register shall be maintained by the site engineer of thecontractor. The shall be deposited to department daily with duly signed by contractor. |
107 | (16) Job card /Docket shall be maintaned properly mentioning as below: a) service Number b) Name c) Rank d) unit e) Date Format of docket/job card shall be provided to contractor. Date of receiving & Date of resolving with time shall be endosrsed on job card. |
108 | (17) Joint measurement weekly. The contarctor should be availble for joint measurement along with supervisor on every Wednesday/as decided by Enginner-in-charge. |
109 | (18) Stationery such ascomplaint register, Job card/Docket , work diary ,hindrance register, site order register etc shall be supplied by the contractor |
110 | NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor. |