Maintenance Of Aravalli Bio-Diversity Park I / C Neela Hauz. Routine Maintenance And Operation Of Sub. Pump Sets And Site Offices At Dda Aravalli Biodiversity Park At Vasant Vihar., Delhi-Delhi

Delhi Development Authority-DDA has published Maintenance Of Aravalli Bio-Diversity Park I / C Neela Hauz. Routine Maintenance And Operation Of Sub. Pump Sets And Site Offices At Dda Aravalli Biodiversity Park At Vasant Vihar.. Submission Date for this Tender is 18-05-2024. Submersible Pump Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43348355
Maintenance Of Aravalli Bio-Diversity Park I / C Neela Hauz. Routine Maintenance And Operation Of Sub. Pump Sets And Site Offices At Dda Aravalli Biodiversity Park At Vasant Vihar.
Open Tender
Indian
Delhi
Delhi
18-05-2024

Tender Details

Maintenance Of Aravalli Bio-Diversity Park I / C Neela Hauz. Routine Maintenance And Operation Of Sub. Pump Sets And Site Offices At Dda Aravalli Biodiversity Park At Vasant Vihar.

Key Value

Document Fees
Refer document
EMD
INR 43208.0 /-
Tender Value
INR 21.60 Lakhs /-

BOQ Items

Name of Work : M/o Aravalli Bio-diversity park i/c Neela Hauz Sub Head :Routine maintenance & operation of sub. Pump sets and site offices at DDA Aravalli biodiversity park at Vasant Vihar. Estimated Cost :- Rs.21,60,410/-
Sl. No. Item Description
1Deploying the following manpower for routine maintenance & repairing of raw/effluent water pump sets,submersible p/sets,all E& M installations,attending day to day complaints on all days i/c preventive maintenance as per schedule & terms & conditions and inventory attached. (a) Wireman cum operator Grade II - 1 No. daily or as when required. (b) Khallasi - 1 No.daily or as when required.
2Supply of ultra bright (single side connection with very high efficency 1 x18 watt approx.4 feet longLED luminaire with diffused cover in polycarbonate body with 5 year manfacturer warrently directly on wall / surface including connection with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable and earthing etc. includingtesting & commissionong as reqd.
3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in recessed steel/ PVC conduit as required. the existing surface
41 x 1.5 sq. mm
53 x 4 sq. mm
6Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
75/6 amps switch
815/16 A switch
93 pin 5/6 A socket outlet
106 pin 15/16 A socket outlet
11Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.
121 or 2 Module (75mmX75mm)
133 Module (100mmX75mm)
14Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and ommissioning etc. as required.
15Single pole
16Double Pole
17Supplying of following sizes ofXLPE insulated PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade including making connection with suitable size of aluminumlugs, testing etc. as required and as per technical specification enclosed.
182 x 16 Sq. mm
194cx25 sq.mm
20Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
21Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ DWC/HDPE/METAL pipe as required. a) Upto 35 sq mm
22Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface/earth as required. a) Upto 35 sq mm
23Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
24Boring and laying ofDWCpipes (ISI) upto 90 mm dia size or RCC Hume pipe(upto 150 mm dia) by trench less technology with no dig. Method by making bore hole in horizontal direction across/along the road with boring equipment i/c jointing, cleaning, rodding of pipe performing mandrel test providing suitable covers on mouth of pipes, excavation of pits of required size & depth and laying of cables in the pipe. etc. complete as required.
25Lifting out ofsubmersible pump set of capacity 2 H.P to 7.5 H.P. from the borewell alongwith exixting pipe GI pipe and dismantling of cable upto reqd. depth etc. complete as reqd.
26Lowering,testing & commissioning of submersible pump set of capacity 2 H.P. to 7.5 H.P. in the borewellalongwith GI pipe & submersible cable , connectionetc. complete as reqd.
27Repairing & rewinding of following rating(Motor & Pump) i/c remetalling of impeller,bush,neck ring,SS shaft including cartagedismantling & reassembling ,painting after repair,nuts,bolts,strainers,testing etc. complete as reqd.
2815 HP sewage submersible pump set(3 Phase)
297.5 HPsewage submersible pump set (3 Phase)
301.5 HP 12 stage openwell(single phase)
313 HP 23 stage submersible pump set (3 phase)
323HP 30 stage submersible pump set (3 phase)
334 HP 30 stage submersible pump set (3 phase)
345 HP 30 stage submersible pump set (3 phase)
356 HP 32 stage submersible pump set (3 phase)
362 HP mono block pump set (single phase)
37Supplying/Replacement of following size of double flanged GI pipe marked "B" class duly threaded & welded with necessary pipe fitting bends, elbow etc complted as reqd.
3850 mm dia
3940 mm dia
40Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.
412 X 10 sq. mm (19mm)
42Supply & replacement of DOL starter of L&T/C&S/Siemens/BCH make to be mounted on existing outdoor feeder pillar i/c connections,testing,commissioning etc. as required.
43Supply & replacement of Minilec/ L&T make single phase preventorto be mounted on existing outdoor feeder pillar i/c connections,testing,commissioning etc. as required.
44Supply & replacement of Ammeter(0-100 A) of AE/Meco maketo be mounted on existing outdoor feeder pillar i/c connections,testing,commissioning etc. as required.
45Ammeter(0-100 A)
46Voltmeter(0-500 V)
47Supply & replacement of ceiling fans of 1200 mm sweep 230 v,single phase,Isi marked(copper wound) i/c dismantling,wiring the down rod with 2 x 1.5 sq.mm. copper wire connections,testing etc. complete as required.
48Comprehensive maintenance contract of RO/ Water purifire cooling with capacity 50 Ltr. Installed in DDA office
49Comprehensive maintenance contract of Water cooler
50Comprehensive maintenance contract of Air conditioners split type 1.5 Ton for 1 season
51Supplying and replacement of exide IMT 1500 12 W 150 Ah tubular Battery i/c buy back value for old battery
52Comprehensive maintenance contract of 1400 VA inverter without battery
53Rewinding copper winding & repairing of 1400 rpm ceiling fan/ Wall fanmotor of different make testing etc. as reqd.
54Supplying and replacement of 5 watt LED bulb alongwith suitable holder for the existing light fitting suitable for 220 V,50 HZ single phase AC supply , connection, testing etc complete as reqd.
55Supplying, Replacement , Testing and Commissioning of 80 watt LED flood light fitting IP-66 with lens made of pressure die cast aluminum hosuing with toughened glass complete with LED"s driver,all accessories connection, testing etc. complete as reqd.
56Supplying and fixing of automatic voltage stabilzer for upto1.5 tom split AC having suitable ratingetc complete as reqd.
57Supplying and replacement of LED tubelight of 40 watt having 4000 lumen against damged/unservicable existing tube light i/c testing,commissioning etc complete as reqd.
58Supplying and replacement of LED lamp of 18 watt to be retro fitted in existing HVAC enclosure fitted on poles etc complete as reqd.
59Providing and fixing following capacity TP & N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses i/c drilling holes in cubicle panel, making connection etc as reqd.
6032 A TP &N
6163 A TP &N
62200 A TP &N
63Supplying & Replacement of following control gear/accessories in the existing instllation for electrical panel boards, motor stater, connection testing etc. as reqd.
6463 AMP TPN MCB (C-Curve), 10 KA
6532 AMP TP MCB (C-Curve), 10 KA breaking capacity.
66Overload relay (9 to 14 Amp)
67No Volt coil for DOL stater
68100 Amp MCCB 4 pole, 36 KA
69Single Phase sub pump controller upto 2 HP
7032 Amp DP MCB (C-Curve), 10 KA breaking capacity
71Contractor block
7230 MFD Capacitor
7350 MFD capacitor
7425 MFD capacitor
75Supplying and making of straight through joint with heat shrinkable kit i/c ferrules and other jointing material for following size fo PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as reqd.
762x16 sq.mm
774x25 sq.mm
78Supplying and connecting of 10 sq.mm copper cable for control wiring in esiting feeder pillar/panel boards etc completed as reqd.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail