Tender For Repair Replacement Of High Mast Light, Garden Lights And Other Connected Items At Various Location Under Ge Nagrota, nagrota-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair Replacement Of High Mast Light, Garden Lights And Other Connected Items At Various Location Under Ge Nagrota. Submission Date for this Tender is 29-05-2024. Tube Light Tenders in nagrota Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43347046
Tender For Repair Replacement Of High Mast Light, Garden Lights And Other Connected Items At Various Location Under Ge Nagrota
Open Tender
Indian
Jammu And Kashmir
nagrota
29-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair Replacement Of High Mast Light, Garden Lights And Other Connected Items At Various Location Under Ge Nagrota

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

Attachment

FileName File Description File Size
a4d0262f-3852-495a-995c-6198941e154e.html Tender Notice 0 KB
BOQ_731285.xls Tender Document 0 KB
TENDER10.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

REPAIR/ REPLACEMENT OFHIGH MAST LIGHT, GARDEN LIGHTS AND OTHER CONNECTED ITEMS AT VARIOUS LOCATION UNDER GE NAGROTA
Sl. No. Item Description
1SCHEDULE ‘A’ PART-I Supply and fixing in replacement of automatic street light switch astronomical time switch 32 Amp for automatic switching of street light. The time switch along with suitable power contactor, MCB and support terminal should be enclosure made of rust proof, electric shock proof as per manufacurers recommendation, IP 66 conforming to IEC including contactor and incoming - outgoing MCBs rating of suitable capacity including necessary connection by providing circuit copper wiring withminimum 10 Sqmm cable incl taking down old onecomplete all as specified and directed.Make:IndoAsian -TL032ASO orequivalent make as specified in PS
2S&Fof60 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LEDstreet light with a miniumum system lumen of 6600 Lm and system wattage not exceeding 60 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminumwith heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. incl taking down old unsv light fittingscomplete all as specified and directed. Make: Orient Cat part No LSFS-060-PC orequivalent make as specified in PS
3S&Fof 90 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LEDstreet light with a miniumum system lumen of 9900 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminumwith heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire.Incl taking down old unsv light fittingscomplete all as specified and directed.Make: Orient Cat part No LSFS-090-PC orequivalent make as specified in PS
4S&F of 120W LED Flood Light made up of pressure die cast Aluminium Housing with toughned glass and high power LEDs and secondary lenses with IP 66 protection. The fixturedrivershould have an operating voltagerange of 120-277V, surge protection of internal 4 KV amd external surge protection of 10 KV, PF.0.95, THD<10%. Incl taking down old unsv light fittingscomplete all as specified and directed .Make : Orient Cat part No LFSM-120-C-V3 orequivalent make as specified in PS
5S&F of 180W LED Flood Light made up of pressure die cast Aluminium Housing with toughned glass and high power LEDs and secondary lenses with IP 66 protection. The fixturedrivershould have an operating voltagerange of 120-277V, surge protection of internal 4 KV amd external surge protection of 10 KV, PF.0.95, THD<10%. Incl taking down old unsv light fittingscomplete all as specified and directed .Make : Orient Cat part No LFSM-200-C-V3 orequivalent make as specified in PS
6S&F in replacement old broken post top Lantern of capacity 20 Wenergy saving , environmental friendly, long life aesthetically designed with symmetrical light distributionspun aluminium land scape luminaire with high power LEDs as light source . The luminare shall be complete IP65 for optical compartment suitable for working for input voltage range of 140 V to 270 V Light shall have power factor more than 0.9 with THD less than 10%.having lm of 900w including 15 Watt LED Bulb complete withelectrical connection with fixing arrangement 50 mm Conduit pipe/ GI pipe complete all as specified and directed .HPL Cat part No HPLLEDPCR 20W orequivalent make as specified in PS
7S&F in replacement old broken post top Lantern of capacity 12 Wenergy saving , environmental friendly, long life aesthetically designed with symmetrical light distributionspun aluminium land scape luminaire with high power LEDs as light source . The luminare shall be complete IP65 for optical compartment suitable for working for input voltage range of 140 V to 270 V Light shall have power factor more than 0.9 with THD less than 10%.having lm of 900w including 12 Watt LED Bulb complete withelectrical connection with fixing arrangement 50 mm Conduit pipe/ GI pipe complete all as specified and directed .HPL Cat part No HPLLEDPDC12W orequivalent make as specified in PS
8Dismantling and taking down carefully flood light, street light /perimeter lighting luminaries from its position of any size/wattage from over head line poles or from elevated sentry post for carrying out repair/replacement of burnt/worn out accessories and removing unserviceable items from site and depositing to MES store yard at Nagrota, including material and labour for replacement of worn out wiring with PVC insulated copper conductor single core cable 1.5 sqmm size, connector block, screws etc.Refixing the fitting after repair to its position compllete all as directed by Engr-in-Charge. (Note- Accessories/components required forreplacement i.e Driver, Surge protection deviceshall be measured and paid separately under relative item of Sch "A" ) Note : Contractor responsibility is to liase with the department concerned for LT supply shut down required to carry out the work & also ensure the safety of labour employed by giving them safety equipments like helmet, gloves, safety belt , discharge rod etc and nothing extra shall be permisissible in this account.
9Supply and fix9 WLED bollard light fitting with opal arylic diffuser and IP 65 protection powder coated square extruded aluminium housing.Mushroom Shape Opal acrylic diffuser is fixed in die cast aluminium frames on four sides for pleasant light outputwith inbuilt driver with 4.5 kV surge protection.Luminaire is provided with a base plate and fixing holes for directly mounting on the concrete pedestal.LEDs mounted on top die cast aluminium housing andcan be separated from base plate for easy maintenance. Make HPL cat part No HPLLEDB9W or equivalent in Bajaj,CG,Havells
10S&F Mounting arm for installation of LED light made from 40mm bore GI pipe light grade of total length 1.5 mts (to be fabricated as per approved design), to be supplied alongwith mounting clamps-02 Nos,fabricated from (65mm x 5mm)MS providing 04 no Nut Bolt washer includingdismantling taking down old unsv bracket of any type with clamps , nuts bolts etccomplete all as per directed. Note : The Contractor should fix the clamp as per site requirment.
11Supply & fixhot Press moulded junction box of size 400mmx300mmx 190mm hinged type including 04 No aluminium Bus Bar of suitable capacity with fixing arrangement like suitable size clamps, Nuts, bolts and washers etc and including SP MCB 6 Amps clamped with Pole complete all as specified anddirected
12Supply and fix1100 Volts heavy duty round sheathed multistranded three core copper conductor cable of size 1.5 Sqmmfor electrical connections to the street lights fittings complete all as specified and directed.
13M& L for Cleaning, preparingand painting with one coat of aluminium paint to steel tubular pole 9 m long complete with cross arms, MS channels, angle iron, frame work, etc incl numbering of pole with black enameled paint from stencilcomplete all as specified and directed.
14Supply and Fixing in replacement of old burnt constant current driver suitable for followning LEDsecurity light/Flood lightfitting of 25 to 60 W capacity complete all as specified and directed. Make CG cat part No S0DRVES-36-700-25W orequivalent make as specified in PS
15Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood lightfitting of 72 to 100 W capacity complete all as specified and directed. Make CG cat part No X075C070V107FNY1BO orequivalent make as specified in PS
16Supply and Fixing in replacement of old burnt constant current driver suitable for followningLED security light/Flood lightfitting of 120 to 180 W capacity complete all as specified and directed. Make CG cat part No X150C070V210FNI1BO orequivalent make as specified in PS
17Supply and Fixing in replacement of unsv burnt surge protection device of capacity 10 kv complete suitable for security light fitting of any capacity complete all as specified and directed . Make CG cat part No SRPS-5K-440 orequivalent make as specified in PS
18S & F in repair MCB TPN 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, includingtaking down existing MCB complete all as specifiedand directed.
19S & F in repair MCB SPN 6-32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking down existing MCB complete all as specifiedand directed.
20S & F in repair MCB SP 6-32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, includingtaking down existing MCB complete all as specifiedand directed.
21Supply laying & testing of cable XLPE insulated screened PVC bedded galvanized steel striper wire armoured electric power cables heavy duty with standard aluminium conductor,1100 volts grade,cross sectional area3.5 core 35 Sqmm complete all as specified and directed.
22All as per ser No 21abovebut 25 Sqmm 4 core
23All as per ser No 21 above but 16 Sqmm 4 core
24All as per ser No 21 above but 10 Sqmm 4 core
25All as per ser No 21abovebut 16 Sqmm 2 core
26All as per ser No 21 above but 10 Sqmm 4 core
27All as per ser No 21 above but 06 Sqmm 2 core
28Excavating in trenches, in any type of soilnot exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed
29Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3m in depth for foundation, etc or not exceeding 10 Sqm on plan and exceeding 1.5m but not exceeding 3m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed
30Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed
31Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
32M&L for Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed.
33M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
34Laying only of old bricks covering with width equal to length of brick as mechanical protection to cables using old retrieved bricksfrom excavation complete all as specified and directed.
35M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass complete all as specified and directed
36M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed
37M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc includingslightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed
38M&L for Service cable/wire 1100 Volt flat twin core aluminium solid conductor of size 4 Sqmm complete all as specified and directed.
39M&L forService cable/wire 1100 Volt flat twin core aluminium solid conductor of size 6 Sqmm complete all as specified and directed.
40M&L for Service cable/wire 1100 Volt flat twin core aluminium soild conductor of size 10 Sqmm complete all as specified and directed.
41M&L for Service cable/wire 1100 Volt flat twin core aluminium soild conductor of size 16 Sqmm complete all as specified and directed.
42S&F in repair for fabrication and installation offeeder pillar box outdoor canopy type, size 40cm (Height) x 30 cm (width) x 12 cm (thick), size of canopy 30cm x 13 cm complete with locking arrangement, 4 Nos aluminium busbar size 20 x 5mm, 8 Nos nut bolt, & 8 Nos aluminium cable socket and with MCB TPN 63 Amp for incoming and outgoing cable embeded in PCC foundation with 2 Nos angle iron leg 25mm x25mm, 400 mm longas per sample including taking down complete all as specified and as directed.
43Supply and fixaluminium lugs of any type / shape of capacity from 10 Sqmm to 25 Sqmm complete all as specified and directed
44Supply and fixaluminium lugs of any type / shape of capacity 35 Sqmmto 95 Sqmm complete all as specified and directed
45Supply and fixaluminium lugs of any type / shape of capacity 120 Sqmm to 240 Sqmm complete all as specified and directed
46M&L for Aluminium conductor, steel reinforced of any size on LT Poles including straining,binding with insulators with Al/copper binding wireas in over head conductors, providing PVC Sleeves for jumper fixed as in repairs, complete all as specified and directed.
47Supply and laying or fixing or passing through pipe or fixing on wall with clamp 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sqmm 2 Core stranded conductor Complete all as specified and directed.
48S&F in repair for fabrication and installation offeeder pillar box outdoor canopy type, size 40cm (Height) x 30 cm (width) x 12 cm (thick), size of canopy 30cm x 13 cm complete with locking arrangement, 4 Nos aluminium busbar size 20 x 5mm, 8 Nos nut bolt, & 8 Nos aluminium cable socket suitable forupto 185 sqmm cable embeded in PCC foundation with 2 Nos angle iron leg 25mm x25mm, 400 mm longas per sample including taking down complete all as specified and as directed.
49Supply and laying GI Tubing Light grade 40 mm Bore dia as Cable Protection fixed on walls/ poles by using the suitable size clamps , nuts , bolts etc or laid in trenches complete all as specfied and directed.
50Supply and laying GI Tubing Light grade 25 mm Bore dia as Cable Protection fixed on walls/ poles by using the suitable size clamps , nuts , bolts etc or laid in trenches complete all as specfied and directed.
51Supply and fix 7 Mtr High hot dip Galvanized octagonal pole made up of 3 mm thick sheet along with Nuts and bolts brackets , suitable size base plate and 04 no of J type foundation bolts with template as suitable for pole complete all as specified and directed.Note : The Rate includes for Earthwork & PCC in foundation of pole shall be as per manufacturer design and recommendation
52M&L for taking down by manual / motorised handle high mast light fittings at 15 to 20m height and refixing after necessary repairs including all necessary staging, etc. for cleaning of perplex covers, etc., tightening of loose connections on poles / walls, and replacing worn out minor parts, etc. and making the fitting functional complete all as specified and as directed Note: The quoted Rate is inclusive oftaking down hig mast ligth & transportation to and fro from MES store/site to civil workshop & reinstalling at same or other location as directed .
53M&L for repairing and rewinding of High mast motor of capacity upto 3 HP/2.4 KW of anymake/model, including removal of existing burnt windings completely and carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enameled copper wire of existing guage complete including dismantling and re-assembling of starter, rotor, blades etc complete all as specified and directed. Note: The quoted Rate is inclusive oftaking down hig mast ligth & transportation to and fro from MES store/site to civil workshop & reinstalling at same or other location as directed .
54M & L forCross arms, bracing, supports, clamps and back plate, fabricated from structural steel sectionincluding nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer incl dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as specified and directed.
55Note: The work under subject BoQ (item No. 1.00 to 54.00 ) are meant for maint of Security light/street light in Nagrota Mil Stn ( Including Katra, Sanjhi Chat, Charli Hill ). The work shall be executed on ground on required basis. Contractor shall deploy sufficient resources to keep smooth working of External Electric Supply at Station. Contractor or his representative will daily attend thecomplaints at E/M complaint cell and in addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notify the complaint, recovery @ Rs 1500/- per day shall be recovered from contractor"s payment for each complaint so notified.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail