Tender For Repair / Replacement Of Internal Electric Infrastructure, Tpn Db, Spn Db And Building Security Light Under, manauri-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair / Replacement Of Internal Electric Infrastructure, Tpn Db, Spn Db And Building Security Light Under. Submission Date for this Tender is 31-05-2024. Electrification Work Tenders in manauri Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43344881
Tender For Repair / Replacement Of Internal Electric Infrastructure, Tpn Db, Spn Db And Building Security Light Under
Open Tender
Indian
Uttar Pradesh
manauri
31-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair / Replacement Of Internal Electric Infrastructure, Tpn Db, Spn Db And Building Security Light Under

Key Value

Document Fees
INR 500 /-
EMD
INR 29000.0 /-
Tender Value
INR 14.50 Lakhs /-

Attachment

FileName File Description File Size
450e2e14-1d27-475e-b0cb-bb8a10914836.html Tender Notice 0 KB
9144Listofmakes.pdf Tender Document 0 KB
9144PS.pdf Tender Document 0 KB
9144Tender.pdf Tender Document 0 KB
BOQ_731186.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: REPAIR / REPLACEMENT OF INTERNAL ELECTRIC INFRASTRUCTURE, TPN DB, SPN DB AND BUILDING SECURITY LIGHT UNDER AGE(I) AF MANAURI
Sl. No. Item Description
1S&F in replacement sheet metal enclosure distribution board TPN, 4 poles, double door, 4 way with 200 Amps rated bus bar including provision to be fix MCCB 4 pole 63 Amps as incomer complete all as specified and as directed. Note: Quoted rate shall be included cost of cutting plastering and colouring to surface of wall to be concealed etc all as per site requirement including matching with existing surface.
2S&F in replacement factory made sheet metal enclosure distribution boards, (protection class IP-43) verticle type suitable for mounting MCCBs/ RCCBs/ MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps ratingbus bar, Single pole and neutral, 12 ways, 240 volts complete all as specified and as directed. Note: MCCBs/ RCCBs/ MCBs shall be measured and paid separately under respective item of this schedule.
3S&F in replacement sheet metal enclosure for MCB distribution board SPN, double door, 8 way with 200 Amp rated bus bar 230 Volts complete all as specified and as directed.
4S&F in replacement factory made sheet metal enclosure distribution boards, (protection class IP-43), verticle type suitable for mounting MCCBs/ RCCBs/ MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating bus bar, Single pole and neutral, 4 ways, 240 volts complete all as specified and as directed. Note:- MCCBs/ RCCBs/ MCBs shall be measured and paid for separately under respective item of this schedule.
5S&F in replacement MCCB, four pole, 415 Volt, 63 Amp rating, 16 kA ultimate breaking capacity fixed in DBs catered herein before complete all as specified and as directed. Make: Seimens / Legrand / C&S / L&T / Havells
6S&F in replacement MCCB, four pole, 415 Volt, 100 Amp rating, 25 kA ultimate breaking capacity fixed in DBs catered herein before complete all as specified and as directed. Make: Seimens / Legrand / C&S / L&T / Havells
7S&F in replacement MCCB, four pole, 415 Volt, 250 Amp rating, 36 kA ultimate breaking capacity fixed in DBs catered herein before complete all as specified and as directed. Make: Seimens / Legrand / C&S / L&T / Havells
8S&F in replacement MCB, tripple pole and neutral, 415 volts, 40 Amps rating, 10kA, "C" series fixed in DBs catered herein before complete all as specified and as directed..
9S&F in replacement MCB, single pole and neutral, 240 volts, 32 Amps rating, 10kA, "C" series fixed in DBs catered herein before complete all as specified and as directed.
10S&F in replacement MCB, single pole, 240 volts, 32 Amps rating, 10kA, "C" series fixed in DBs catered herein before complete all as specified and as directed.
11S&F in replacement MCB, single pole, 240 volts, 6 to 10 Amps rating, 10kA, "C" series fixed in DBs complete all as specified and as directed.
12S&F in replacement PVC insulated muilticore strandard copper single & multi flexible round cable size 1.0 Sqmm 3 core ISI marked 660/1100 Volt conforming to IS:694-1990 complete all as specified and as directed.
13S&F in replacement PVC insulated muilticore strandard copper single & multi flexible round cable size 2.5 Sqmm 3 core ISI marked 660/1100 Volt conforming to IS:694-1990 complete all as specified and as directed.
14S&F in replacement PVC insulated muilticore strandard copper single & multi flexible round cable size 4.0 Sqmm 3 core ISI marked 660/1100 Volt conforming to IS:694-1990 complete all as specified and as directed.
15S&F in replacement PVC insulatedsheathed aluminium conductor armoured cable with inner sheathing for service connection size 10 Sqmm 2 core 1100 Volt complete all as specified and as directed.
16S&F in replacement PVC insulated sheathed aluminium conductor armoured cable with inner sheathing for service connection size 6 Sqmm 2 core 1100 Volt complete all as specified and as directed.
17M&L for earthing complete (in replacement) with galvanised mild steel earth electrode plate 600 X 600 X 6 mm thick buried directly and vertically in groundconnected to galvanised iron earth strip 32x6 mm size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanised iron 40 mm bore medium grade pipe with all fittings from the earth electrodefixed along pole with and including 25 x 6mm flat iron clamp, bolts, nuts and washers and watering pipe shall be 20 mm bore GI medium gradefrom top of the earth electrode to bottom of the earth pit including all excavation and earth work in any type of soil and removal of surplus soil upto 50 metre, PCC pit with pre-cast RCC cover with handle, charcoal/salt, funnel , CI frame etc complete all as specified and as directed. Notes :-(i)The concrete pit shall be made in PCC 1:3:6 type C-1,40mm thick precast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate with suitable MS handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Plate electrode shall be surrounded by adequate quantity of charcoal dust & salt to a packed thickness of 15 cm on all sides.
18M&L for earth continuity conductor or main earthing lead 32x6 mm GI strip laid in pipe or fixed on wall or any other position including jointing by tinned copper/brass nuts, bolts and washers in adition brazing at every joint complete all as specified and as directed.
19S&F in replacement building security light fittings 45 watts energy saving including making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings and mounting bracket made out by GI pipe light grade in 25 mm dia of bore in required length bend in 120 degree fixedwith clamping of surface of wall using clamp made out by GI strip in size 32 x4 mm using nut bolt and washer etc complete all as specified and as directed. Make: Bajaj / Philips / Crompton / Havells
20M&L for sub main wiring with two runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 06 Sqmm and drawing through in concelead rigid non metallic PVC conduit pipe medium grade heavy duty in suitable size with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 06 Sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring with accessories complete all as specified and as directed. Note: (i) Two run of 06 sqmm with one run of PVC conduit pipe shall be measured against one unit. (ii) Cost of cutting / chasing / plastering / colouring etc as site shall be included matching to disturbed surface all as existed.
21All as per Item No. 20.00 above but three run of 2 Core 4 Sqmm for phase, neutral and earth wire with suitable size concealed PVC conduit pipe complete all as specified and as directed.
22All as per Item No. 20.00 above but size 2x1.5+ 1x 1.5 Sqmm with conduit pipe laid on surface of false ceiling or concealed as site required (For building security light) complete all as specified and as directed.
23M&L for recharging to existed earthing at E/M installation in any type upto strandard value using required chemical such as Nacl / MgSo4 / other approvad chemical including reveting / welding / bolting to earth lead including testing etc by Tech rep with reveting bolting replacing to nut bolt and washer etc to GI earting strip for making earth continuty from transformer / panels to earting pit all as site required complete all as specified and as directed. Note: Payment under this item shall be made after getting resistance value satisfactorly and record shall be submitte in this office.
24M&L for painting on complete body in and out side of existed LT panel in any size and specification at varrious location after removing old fadded paint scarping, cleaning rubbing etc all for making smooth to surface using shyenthic enamel paint in two coat (one as finishing) over one coat of red oxide in external and internal surface including marking as given in different colour including cutting welding jointing reveting repacing to hinges etccomplete all as specified and as directed. Note :Colour of paint shall be approved by Engr-in-Charge.
25M&L for painting on steel tubuler pole in any specification at varrious location after removing old fadded paint scarping, cleaning rubbing etc all for making smooth to surface using aluminium paint in two coat (one as finishing) over one coat of red oxide complete in external and internal surface with GI pipe bracket, clamp nut bolt etc all as site withmarkingas given in different colour complete all as specified and as directed.
26Supply, erecting, fixing in replacement steel tubular swaged poles with cast iron base plate in minium 6 mm thick finial taper plug bolt nut screws 410 SP 31 type 9 m long painting by black paint in two coat in internal surface and aluminium paint in two coat (one as finishing) over one coat of red oxide primer in external surface and making alternate strip in 30 cm width upto 1.5 m above normal groung level using diffrent colour with marking serial No etc complete all as specified and as directed.
27M&L for pole foundation cement concrete type B-2 in ratio 1:2:4 (using 40 mm graded crushed stone aggregate) complete all as specified and as directed.
28M&L for cement concrete type B-2in ratio 1:2:4 (using 20 mm graded crushed stone aggregate) in pole coping complete all as specified and as directed.
29S&F in replacement LED tube light fitting 4 feet long 20 W surface mounted on 02 Nos round / Square PVC blockincluding making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings complete all as specified and as directed.
30S&F in replacement LED tube light fitting with frame, driver etc in 10 W (NW), 2 feet long white colour mounting on tow Nos of PVC round / squire block on surface of wall / beam etc including making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings complete all as specified and as directed.
31Excavation in treanches soft/loosesoil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for shaft well, cesspits, manholes, pireholes etc not exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
32Returning & filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM thick in soft/ loose soil complete all as specified and as directed.
33Removing excavated material not exceeding 50mtr and deposting where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed.
34M&L for sand cushioning (dry sand) to under ground cable for cable protection with layer of 8 cm deep before laying the cable and 15 cm depth after laying the cable complete all as specified and as directed. Note: Punned thickness of sand layers shall be measured and paid contractor.
35M&L for brick, subclass "B" well burnt, laid dry flat in trenches for protection of cable over LT/HT cable complete all as specified and as directed.
36Supply laid in trences/ fixing with pole in replacement connecting, thembling, glanding of XLPE insulated cable screened PVC badded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 4 core (earhted) complete all as specified and as directed. Make: Finolex / Havells / Polycab / Fort Gloster / Paragon / RPG
37All as per item No 36.00 above but of size 25 Sqmm 4 core (earhted) complete all as specified and as directed.
38All as per item No 36.00 above but size 35.0 Sq mm 3.5 core(earthed) complete all as specified and as directed.
39All as per item No 36.00 above but size 50.0 sq mm 3.5 core (earhted) complete all as specified and as directed.
40All as per item No 36.00 above but size 95.0 sq mm 3.5 core(earthed) complete all as specified and as directed.
41All as per item No 36.00 above but size 120.0 sq mm 3.5 core (earhted) complete all as specified and as directed.
42M&L boring of holes under road/drain/PCC path by mannual method for inserting upto 150 MM dia of bore pipe light grade GI tubing for cable protection complete all as specified and as directed.
43S&F in replacement steel water tubing 40 MM bore, galvanised, light grade with and including all fittings accessories such as clamp (02 Nos) complete and laid in trenches, under road crossing, fixed on poles/walls for cable protection complete all as specified and as directed.
44All as per Item No. 43.00 above but of size 50 MM bore dia complete all as specified and as directed.
45Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix "B" to Particular specifications as approved by AGE (I) AF manauri
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy