Tender For Repair/ Maintenance Of Vrf, Window/ Split/ Cassette Type Acs At Hq Ids Under Ge New Delhi, delhi-Delhi

Military Engineer Services-MES has published Tender For Repair/ Maintenance Of Vrf, Window/ Split/ Cassette Type Acs At Hq Ids Under Ge New Delhi. Submission Date for this Tender is 30-05-2024. AMC of Air Condition Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43342351
Tender For Repair/ Maintenance Of Vrf, Window/ Split/ Cassette Type Acs At Hq Ids Under Ge New Delhi
Open Tender
Indian
Delhi
delhi
30-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair/ Maintenance Of Vrf, Window/ Split/ Cassette Type Acs At Hq Ids Under Ge New Delhi

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
82b6151e-6d68-468f-87a7-f4b1ecb48c3f.html Tender Notice 0 KB
BOQ_730955.xls Tender Document 0 KB
TD05.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: REPAIR/ MAINT OF VRF, WINDOW/ SPLIT/ CASSETTE TYPE ACs AT HQ IDS UNDER GE NEW DELHI
Sl. No. Item Description
1Labour for checking and attending complaints of ACs, water coolers, Refrigerators etc of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed by Engineer-in-charge. Note: (a) The contractor mush submit copy of valid competency certificate of two (02) AC mechanics each having minimum working experience of 02 years in the field of Air Conditioning & Refrigeration. The certificate should be issued by OEM only, stating the technical qualification & experience of the mechanics to be deployed, failing which the bid of the contractor is liable to be rejected. (b) Any parts required forreplacementshall be measured and paid separately under respective items. (c) The contractor should detail minimum one AC Mechanic & one helper to attend complaints dailly in HQ IDS, DAIRA during working hour. (d) The minor complaint be attended within 2 hours. (e) If the complaint not attended/not completed with in 2 hours recovery will be done as follows:- (i) Attended between 2-4 hours @Rs 100 (ii) between 4-12 hours @Rs 200 (iii) For nextevery 12 hours @Rs 500
2Servicing of Window type AC 1.5/2 Ton capacity ofany make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checkingof electric circuit for smooth functioning of AC (two times in a year) pre summer drive and pre winter drive) complete all as specified and directed. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
3All as per item No 2 above but Split AC of any type and 1.5/2 Ton capacity complete all as specified and directed. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
4Supply only in replacement of Running capacitor 6 mfd 230 voltcomplete all as specified and directed. Make:Usha/Epcos/Havells
5Supply only in replacement of multi Running capacitor 50+6 mfd 230 volt complete all as specified and directed. Make:Usha/Epcos/Havells
6Supply only in replacement of Running capacitor 4 mfd 230 volt complete all as specified and directed. Make: Usha/Epcos/Tesla
7Supply & charging gas refrigerant R-22 /410 A/ or as existing to window type / Splittype/ Cassette/ Package type AC up to 4 Ton capacity including removing of leakage if any and testing complete all as specified & directed by Engineer-in-charge
8Supply onlyin replacement of starting relay suitable for 1.5/2 Ton capacity AC complete all as specified and directed. Make: Renutrol/Classic/Indfos
9Supply only in replacement of over load protector suitable for 1.5 Ton capacity AC complete all as specified and directed. Make: Pecific/renutrol/Hitech
10Supply only in replacement of thermostat switch suitable for 1.5/2 Ton capacity AC complete all as specified and directed. Make: Pecific/renutrol/Indfos
11S & F inreplacementcompressor Rotary/Reciprocating type window accapacity 1.5/2 TR,refixing includingbrazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/ Carrier/Tecumseh/Copeland/ existing make
12S & F in replacement of Rotary /Reciprocatingcompressor ofNON inverter split type AC compressor as per the existing type and capacity 1.5 /2TR,refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/Carrier/Tecumseh/Copeland/ existing make
13S & F in replacement of compressor ofInverter type split AC capacity1.5 /2 TR and replacing the same with new compressor as per the existing type and capacity 1.5 /2TR,refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/Carrier/Tecumseh/Copeland/ existing make
14Supply & fix in replacement of air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity any type split AC complete all as specified and directed.
15Supply & fix in replacement of air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity window type Acs complete all as specified and directed.
16M&L for taking down existing unserviceable blower motor (Indoor) capacity 1/4,1/5 HP single/double shaftas per existing and refixing with new blower motor in replacement of as per existing model on site sutaible for Splittype ACs 1.5/2 Ton complete all as specified and directed by engr-in-charge. Make : LG/Career/Voltas/Hitachi.
17M&L for taking down existing unserviceable out doorfan motor and fixing of new fan motor capacity 1/4,1/5 HP single/double shaft as per existing model sutaible for any tpeSplit ACs 1.5/2 Ton complete all as specified and directed by engr-in-charge.Make : LG/Career/Voltas/Hitachi.
18Supply & fix replacement PVC insulatedflexible copper conductor 3 core 1100V Grade of size 70/.0076 (2.5 sqmm) complete all as specified and directed. Make:- Polycab/Havells/Finolex
19Supply & fix replacement PVC insulatedflexible copper conductor 4 core 1100V Grade of size 70/.0076 (2.5 sqmm) complete all as specified and directed. Make:- Polycab/Havells/Finolex
20Supply & fixin replacement ofcondensor fan blade made out of aluminium /plastic suitable for upto 2 Ton capacity window type Acs complete all as specified and directed.
21Supply & fixin replacement ofcondensor fan blade made out of aluminium /plastic suitable for upto 2 Ton capacity for any type splitAcs complete all as specified and directed.
22Supply & fix in replacement of evaporatingair blower made out of aluminium/ plastic suitable for upto 2 Ton capacity for window type AC complete all as specified and directed.
23Supply & fix in replacement of evaporatingair blower made out of aluminium/ plastic suitable for upto 2 Ton capacity for anytype Split AC complete all as specified and directed.
24Supply onlyin replacement of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split AC units complete all as specified and directed.Make: Supreme/Gulf-o-flex/Superlon.
25Supply only in replacement of COPPER TUBINGAND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split AC units complete all as specified and directed.Make:- Supreme/Gulf-o-flex/Superlon.
26M & L for replacement of front grill suitable for window type ACs upto 2 Ton capacity of any Make as per existing size and shape complete all as specified and directed.
27M & L for replacement of reverse valve system suitable to 1.5/2 Ton split/window AC for heating option and includes copper pipe connection complete all as specified and directed. Note: Gas charging shall be paid and measured under respective item
28M&L for taking down existingcondensing coil by removing it from existing outdoor unit by using LPG blower and fixing of new condensing coil of suitable size/capacity for 1.5/2 Ton any type split Acs complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
29M&L for taking down existingevaporating coil by removing it from existing indoor unit by using LPG blower and fixing of new evaporating coil of suitable size of existing make, capacity for 1.5/2 Ton any type splitAcs complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
30M&L for taking down existingcondensing coil by removing it from existing outdoor unit by using LPG blower and fixing of new condensing coil of suitable size/capacity for 1.5/2 Ton window type Acs in replacement of as per existing size/shape and as per existing make complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
31M&L for taking down existingevaporating coil by removing it from existing indoor unit by using LPG blower and fixing of new evaporating coil of suitable size/capacity for 1.5/2 Ton window type Acs in replacement of as per existing size/shape and as per existing make complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
32M&L for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas R-12/22/134a for water cooler, Split type/Window type AC/ Deep Freezer /Refrigerator any size any capacity as on site complete all as specified and directed by Engr-in-Charge.
33Supply & fix in replacement ofbrass flare nut/connector heavy duty of size 6 mm/9 mm (1/4", 1/2") as per existing make complete all as specified and directed.
34M&L for replacement of control processing board (Remote control kit) with hand set including replacement of current transformer, ICs, diodes, resistances, sensors etc complete for 1.5/2 Ton split type ACs of any make & model complete all as specified and directed.
35M&L for replacement of unserviceable display along with PCB suitable for NONinverter Split type AC 1.5/2 TR with new PCB along with display unit complete all as specified and directed. Make-Hitachi/Voltas/Carrier/Daikin
36M&L for opening and taking down existing unserviceable PCB along with display unitand fixing of newPCB along with display unit suitable forIndoor unit of Inverter AC of capacity1.5/2 Ton split type ACcomplete all as specified and directed by Engr-in-Charge.
37M&L for opening and taking down existing unserviceable PCB and fixing of newPCB suitable forOutdoor unit of 1.5/2 Ton split type AC inverter AC complete all as specified and directed by Engr-in-Charge.
38M&L for taking down unserviceable condensor fan motor ofout door unit inverter type and supply and fix in replacement of DC motor 125 W suitable for outddor unit of Inverter type AC of capacity 1.5/2.0 Ton complete all as specified and as directed by engr-in-Charge
39Supply and fixingwindow ACkit 1.5/2.0 TR with sensorcomplete with condensing coil, blower and motor suitable to existing model and make AC complete all as specified and directed by Engineer-in-charge. Make:- LG, Napolean & Skoda
40Supply and fixingin replacement of split type AC 1.5/2 TonindoorPCB unit kitcomplete with cooling coil, blower with motor, PCB and remotecomplete with fixing plate suitable to inverter typemodel and make AC complete all as specified and directed by Engineer-in-charge.
41Supply and fixingin replacement of split type AC 1.5/2 Ton outdoor unit kit complete with compressor, condensor coil, condensor fan with blade and sensor suitable toinverter typeexisting model and make AC complete all as specified and directed by Engineer-in-charge.
42S & Fin replacement split type AC indoor unit kit 1.5 /2 TR capacity complete with cooling coil, blower with motor, PCB and remote complete with fixing plate suitable to Non inverter ACexisting model and make AC complete all as specified and directed by Engineer-in-charge. Make- Hitachi/LG/Daikin
43S & F split type AC outdoor kit 1.5 / 2 TR complete with compressor, condensing coil, condensor fan motor suitable to existing model and make iron grill, suitable To NON inverter ACfor outdoor unit and flair nuts for connection of Copper pipe complete all as specified and directed by Engineer-in-charge. Make- Hitachi/LG/Daikin
44Supply & fix in replacement of direction changer louver motor ( swing motor) suitable for any type split type Acs 1.5/2 capacity as per existing make and model complete all as specified and directed.
45Supply & fix in replacement of cordless Remote for any type split ACssuitable for 1.5/2 Ton AC as per sample complete all as specified and directed. Make- Hitachi/Voltas/LG
46Supply & fix in replacement of cordless Remote for ACssuitable for 1.5/2 Tonwindow AC as per sample complete all as specified and directed. Make- Hitachi/Voltas/LG
47M&L for comprehensive checking of entire VRF units once in a quarter capacity 32 HP installed at South Hutments including replacement of PCB kit of indoor units (16 Nos ) fan motor, compressor as per existing , brazing to joints. gas top up, repair to display along with connected accessories, short circuiting of wiring rectification and its replacement, including repair/ replacement to LCD display servicing or descaling of cooling fins and removal of dirt by pressure washing etc. It comprises 16 nos indoor unit complete all as specified and directed by Engineer-in-charge. Note: Entire work shall be carried out by OEM /OEM authorised dealer
48S & F in replacement of Voltage stablizer 2 to 5 KVA copper wounded comprising of digital display ,digital ammeter and digital voltmeter suitable for 1.5/2 TR split/window AC complete all as specified and directed
49S&F in replacement of of plug top3 pin, 15 Amps, 230 volts, 50 Hz AC complete all as specified and directed.
50M&L in replacement of modular Plug & socket board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz , with MCB SP 20-32 Amps complete all as specified and as directed by Engr-in-Charge.Make- Havells/Legrand
51S&F in replacement of of PVC insulated and PVC sheathed, flexible copper conductor cable 3 core, 1100 volts grade, multi stranded type of size 6.0 sqmm complete all as specified and directed.
52Supply & fix in replacement of ofdrain pipe PVC flexible, spring type of size15/20 mm dia as per site requirement complete all as specified and directed.
53M & L for Shifting of windowtype ACs 1.5 /2.0 TR capacity including removing of connected accessories complete all as specified and directed.
54M & L for Shifting of Split type Acs1.5 /2.0 TR capacity including removing of indoor unit, out door unit andconnected accessories complete all as specified and directed by Enger -in- charge
55Supply only in replacement of wall stand /chauki stand to fix outdoor of split/cassete ac made ofmetalic stell complete all as specified and directed
56M& L for cuting of walls to fix the window AC1.5/2 TR as per existing shape and size and maintaining the surface as per existing condition complete all as pecified and directed. Note: Rate of plywood ,cement putty and paint included in the quoted rates