Tender For Repair/Maintenance And Replacement Of Old Unsv Gi/Ci Pipe Lines Of Various Locations Including Control Valves And Valve Pits Etc At Zone A And Zone B At Af Stn Bihta, bihta-Bihar

Military Engineer Services-MES has published Tender For Repair/Maintenance And Replacement Of Old Unsv Gi/Ci Pipe Lines Of Various Locations Including Control Valves And Valve Pits Etc At Zone A And Zone B At Af Stn Bihta. Submission Date for this Tender is 28-05-2024. Cast Iron Pipe Tenders in bihta Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

43342344
Tender For Repair/Maintenance And Replacement Of Old Unsv Gi/Ci Pipe Lines Of Various Locations Including Control Valves And Valve Pits Etc At Zone A And Zone B At Af Stn Bihta
Open Tender
Indian
Bihar
bihta
28-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair/Maintenance And Replacement Of Old Unsv Gi/Ci Pipe Lines Of Various Locations Including Control Valves And Valve Pits Etc At Zone A And Zone B At Af Stn Bihta

Key Value

Document Fees
INR 500 /-
EMD
INR 32000.0 /-
Tender Value
INR 16 Lakhs /-

Attachment

FileName File Description File Size
c42fdef7-fee9-4f5f-8894-cd2c07da251b.html Tender Notice 0 KB
BOQ_731044.xls Tender Document 0 KB
TenderDocs8406.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: REPAIR/MAINTENANCE AND REPLACEMENT OF OLD UNSV GI/CI PIPE LINES OF VARIOUS LOCATIONS INCLUDING CONTROL VALVES AND VALVE PITS ETC AT ZONE ‘A’ & ZONE ‘B’ AT AF STN BIHTA
Sl. No. Item Description
1Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable/ Pipe lines / erection of poles, stays etc. complete all as specified and as directed.
2Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
3Removing of excavated material n.exc 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point complete all as specified.
4M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in polepit and foundation etc.
5M&L for PCC 1:3:6 type C-2 using 20mm graded aggregate, mechanically crushed stone for mass filling in water supply pits and foundation all as specified.
6S & F in replacement of old unsv MCCB triple pole 125 Amps with thermal magnetic trip and earth link connectors in LT control panel board where directed and making necessary electrical connections complete all as directed.
7S & F in replacement of old unsv Power contactors 4 pole 40-63 Amps with 2NO+2NCwhere directed and making necessary electrical connections complete all as specified and as directed.
8M & L for cleaning of overhead reservoir internal portion from base to top including scraping of mud silt from base and walls, washing complete internal surfaces by using bleaching powder, antibacterial sodium hypochlorite solution, removing the silt/mud water out side the tank and de-silting from connecting pipes and applying internally one coat of lime wash to RCC walls, base of tanks of 50000 gallons upto 30 mtrs staging complete & writing details of cleaning in prescribed format complete all as specified and as directed. Therefore following procedure shall be followed during cleaning of OHT. (a)Cleaning of water tanks with high pressure water jet with pressure not exeeding 28Kg/Sqcm and remove all masses algae and dirt. (b)Removal of dirty water alongwith sludge using sludge machines and disposal of the same to a safe distance. (c)Scrubbing of floors using industrial vacuum cleaner. (d)Applying of anti bacterial sterilization to walls floors and roofs of tanks. (e)Testing of water shall be carried out after cleaning of tank and a certificate to this effect shall be submitted while claiming payment . (f)Tank capacity and date of cleaning shall be marked on tanks neatly with oil paint all as directed by the EIC. Location : Pump House No 2 (Near MES Colony) Note : Cleaning of reservoirs shall be carried out the gap in between 4-5 months or as and when required/demanded by the Engr-in-Charge.
9Description all as per item Ser No. 8 above but for 75000 gallons. Location : Pump House No 3
10Description all as per item Ser No. 8 above but for 5000 gallons. Location : Ops
11S & F in replacement of old unsvfully automatic star delta starter assembly (ASD) - HGS Series having Range: 26 KW, conforms to IS/IEC 60947-4-1, provided with Protection Degree IP 54, having extended wide band coil, FRLS internal wiring, Class H insulation air break starter type, having contactor size 32, overload relay range 28 A to 40 A and complete suitable for 30/35HP sub mersible pumping set including fixing in same position and making necessary electrical connection to LT control panel of pump house and testing upto the satisfaction of Engr-in-Charge complete all as specified and as directed.Make: Havells Cat Part No IHHASDXB or equivalent in Schneider/ABB etc.
12M & L for rewinding of burnt submersible pumping set of capacity 25/30HP capacity with the existing gauge of copper winding wire with same insulation including replacement of bearings complete all as per standard norms and testing upto the satisfaction of Engr in-charge.
13Taking out old unserviceable DI/CI pipe with all fittings from trenches of following sizes all as directed :- (Note : Excavation & earth work will be measured & paid seperately under respective item).
14150 mm dia bore.
15100 mm dia bore.
1680 mm dia bore.
17Supply only DI pipe of 150 mm boreISI marked, spigot and socketed type, Class K-7 centrifugally cast suitable for rubber tyton joints laid in trenches complete all as specified and as directed by Engineer-in-charge. (Earth work for excess width of taking down, route change of pipe & joints shall be measured and paid separately).
18Description all as per ser item No.14 here-in-before but for 100 mm bore.
19Description all as per ser item No.14 here-in-before but for 80 mm bore.
20Laying only DI/CI pipe new or old position in trenches where directed and testing complete all as specified :- (Note : Excavation & earth work will be measured & paid seperately under respective item).
21150 mm dia bore.
22100 mm dia bore.
2380 mm dia bore.
24M&L Bends (any type, radius and angle), tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150 mm bore for spigot socketed pipes.
25M & L Bends, Tapers, Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged upto 150mm bore for flanged pipes.
26Taking out old unserviceable GI tubing with all fittings from trenches, walls, floors etc. of following sizes all as directed :- (Note : Excavation & earth work will be measured & paid seperately under respective item ).
2780 mm dia bore.
2850 mm dia bore.
2925 mm dia bore.
3020 mm dia bore.
31M & L for GI pipe medium grade with all fittings laid in trenches 80mm bore medium grade ISI Markedof following sizes with all fittings complete all as specified and as directed by Engineer-in-Charge.
32Description all as per ser item No 21 here-in-before but of size 50 mm dia.
33Description all as per ser item No 21 here-in-before but of size 25 mm dia.
34Description all as per ser item No 21 here-in-before but of size 20 mm dia.
35S & F Gun metal gate valve 50 mmISI marked with iron wheel screwed down high pressure screwed both ends for iron pipe incl taking down old unserviceablecomplete all as specified and directed by Engineer-in-Charge.
36Description all as per ser item No 25 here-in-before but of 40 mm bore.
37Description all as per ser item No 25 here-in-before but of 25 mm bore .
38Description all as per ser item No 25 here-in-before but of 20 mm bore.
39M&L for lead wool joints for spigot and socket pipes and fittings with all jointing materials like spun yarn etc all as specified and directed for the following sizes:-
40150 mm bore.
41100 mm bore.
4280 mm bore.
43M&L forrun lead joints for spigot and socket pipes and fittings with all jointing materials like spun yarn etc all as specified and directed for the following sizes:-
44150 mm bore.
45100 mm bore.
4680 mm bore.
47Material & Labour for brick masonry valve pit internal size 1200mm x 1200mm x 1200mm with one brick thick wall using sub class ‘B’ brick in cement mortar 1:6 over 20cm thick PCC plate form with 15cm off sets on every side of 1:3:6 type C-1 including plastering of internal surfacesand exposed surfaces with 15mm thick plastering in cement mortar 1:4 and 50mm thick RCC cover (in two equal parts 1:2:4 type B-1 with 10mm dia deformed bars at 10cm interval on both side including necessary form work with 150mm dia hole in the center) complete all as specified and as directed by Engineer-in-Charge.
48Description all as per ser item No 31 here-in-before but of size 1000mm x 1000mm x 1000 -ditto-
49Description all as per ser item No 31 here-in-before but of size 600mm x 600mm x 600m -ditto-
50S & F in replacement of unsv/damaged 15mm bib tap cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
51Labour only for disconnecting unsv/defective electric connections and lifting the unserviceable pumping sets 25/30/35HP from the bore well and lowering of submersible pump sets after repairing including M&L forreplacement of gaskets, suitable size of steel nuts, bolts and washers of suitable size complete all as directed by Engineer-in charge including transportation to workshop and back to site complete.
52S&F 3 core flat copper conductor, multistranded cablefor submersible pump set of 1100 voltgrade 10 sqmm size MAKE: HAVELLS Cat Pat NoWHPNDSKG3010 or equivelent make and model of FINOLEX/PLAZA /Paragon.
53Supply & Fixing in replacement of old unsv CI Sluice valve with flanged ends of size 150 mm dia complete with gun metal or stainless steel spindle and cast iron hand wheel including rubber / fiber board gasket, nuts, washer etc. including taking down old/unservicable Sluice valve complete all as specified and as directed by Engineer-in Charge. Make: BVI/ Kirloskar/ Kishor/Kartar.
54Description all as per item Ser No 37 but for 100mm dia.
55Description all as per item Ser No 37 but for 80mm dia.
56Cutting of existing cast iron pipe and reducing the length upto required level for insertion of new tee, branch connection or any other means etc. upto 150mm dia complete all as specified and as directed by Engineer -in-charge.
57M&L for Surface dressing in hard / dense soil not exceeding 15 cm deep and clearing all the grass, shrubs and bushes etc. in the sub station yard and making the surface/floor clean all as directed and specified.
58Material and Labour for dismantling the 150mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland bush, nuts, gasket, bonnet and disc or as required at site complete all as specified and as directed.
59Material and Labour for dismantling the 100 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland bush, nuts, gasket ,bonnet and disc or as required at site complete all as specified and as directed.
60Material and Labour for dismantling the 80 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland bush, nuts, gasket, bonnet and disc or as required at site complete all as specified and as directed.
61Material and Labour for gland packing in leaking Sluice Valves of 80mm dia size Complete including replacing / tightening the existing bolts and nuts etc. complete all as directed by Engr-in-Charge.
62Material and Labour for gland packing in leaking Sluice Valves of 100 mm dia size Complete including replacing / tightening the existing bolts and nuts etc. complete all as directed by Engr-in-Charge.
63Material and Labour for gland packing in leaking Sluice Valves of 150 mm dia size Complete including replacing / tightening the existing bolts and nuts etc. complete all as directed by Engr-in-Charge.
64M&L for collection of water samples from various bore wells located at different area of air force station Bihta in white colour PVC containers of capacity not less than 5.0 Ltr, hygenically dry, neat & clean duly sealed and transporting the same to laboratory for followings tests of drinking water for portability charaterstics/parameter as per IS 10500-2012 from Government approved/certified laboratory seperately for each borewell and submit the test results/reports of water samples (bore well wise) to Engineer in chargefor maintain the record at bore wells/sub divn level and Engineer in charge will submit the same as and when asked by GE complete all as specified and directed.
65(a) Colour (Ref Std & test method as per IS:3025(P-4)-1983/2017 (b) Odour (Ref Std & test method as per IS:3025(P-5)-1983/2017 (c) Turbidity (Ref Std & test method as per IS:3025(P-10)-1984/2002 (d) Temperature (Ref Std & test method as per IS:3025(P-44)-1993/2009 (e) Taste (Ref Std & test method as per IS:3025(P-44)-1993/2009 (f) TDS(Total dissolved Solids) (Ref Std & test method as per IS:3025(P-9)-1984/2017 (g) pH (Ref Std & test method as per IS:3025(P-11)-1983/2017 (h) Iron as Fe (Ref Std & test method as per IS:3025(P-40)-1991/2014 (j) Nitrate as N (Ref Std & test method as per IS:3025(P-34)-1988/2003. (k) Arsenic as As (Ref Std & test method as per 3114:APHA 23rd End-2017(l) Chloride as Cl (Ref Std & test method as per IS:3025(P-32)-1988/2014 (m) Sulphate as SO4 (Ref Std & test method as per IS:3025(P-24)-1988/2014 (n) Alkalinity as CaCO3 (Ref Std & test method as per IS:3025(P-23)-1986/2014 (o) Hardness (Ref Std & test method as per IS:3025(P-21)-2009/2014 (p) Calcium as Ca (Ref Std & test method as per IS:3025(P-40)-1991/2014 (q) Magnesium as Mg (Ref Std & test method as per IS:3025(P-46)-1991/2014 (r) Conductivity (Ref Std & test method as per IS:3025(P-45)-1993/2013 (s) Fluoride as F (Ref Std & test method as per IS:3025(P-60)-2001/2013 (t) Coliform Count (Ref Std & test method as per IS:1622:1981 (RA 2009) (u) Residual Chlorine (Ref Std & test method as per IS:3025(P-26)-2007/2014 (v) E-Coli (Ref Std & test method as per IS:1622:1981 (RA 2009)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail