Tender For Repair To Water Proofing Treatment To Roof,Sunken And Parapet Wall In Md Accn Area Of Age B/R-I Under Ge Nams, Amritsar-Punjab

Military Engineer Services-MES has published Tender For Repair To Water Proofing Treatment To Roof,Sunken And Parapet Wall In Md Accn Area Of Age B/R-I Under Ge Nams. Submission Date for this Tender is 30-05-2024. Water Proofing Work Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43342210
Corrigendum : Tender For Repair To Water Proofing Treatment To Roof,Sunken And Parapet Wall In Md Accn Area Of Age B/R-I Under Ge Nams
Open Tender
Indian
Punjab
Amritsar
30-05-2024

Tender Details

Repair To Water Proofing Treatment To Roof, Sunken And Parapet Wall In Md Accn Area Of Age B / R-I Under Ge Nams

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-May-2024 Tender corrigendum Other 30-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work : REPAIR TO WATER PROOFING TREATMENT TO ROOF,SUNKEN AND PARAPET WALL IN MD ACCN AREA OF AGE B/R-I UNDER GE NAMS
Sl. No. Item Description
1Demolition of brickwork, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed.
2M & L for brick work with sub class "B" bricks in CM (1:4) straight or curved on plan exc 6 mtrs mean radius,complete all as specified and directed.
3Description all as per item No 01.00 abovebut except bricks(old dismantled serviceable bricks obtained from srl Item No 01 shall bereused after necessary cleaning of mortar) complete all as specified and directed.
4Taking down cement plaster on brick/stone/concrete walls /ceiling incl racking out joints etc,hacking for key, scrubing down with water etc & dispose off debris upto a distance n exc.500 mtrs where directed complete all as specified and directed.
5M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:4. finishing even and fair complete all as specified and directed. (WPC shall be measuared seperatly and paid @ 200ML for 50kg cement bags or as per manufacturer"s instructions).
6M&L for 10 mm thick cement plaster in CM (1:3) onconcrete surfaces of ceiling/sunken walls surface and finishing the surface even and smooth (without using extra cement) complete all as specified and directed.
7Supply only liquid integral water proofing compound all as directed.
8M&L for preparationof new plastered surfaces of wall and applyingtwo coats of cement base paint over a coat of primer complete all as specified and directed.
9M&L for applying three coat of white wash on ceiling surfaces incl preparation of newly plastered ceiling surfaces complete all as specified and directed.
10Demolition of cement Concrete in sunken floors exc 15cm thick ( above ground level) and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas complete all as specified and directed.
11M&L for Cement concrete 1:5:10 type F-2 (using 40mm graded brick aggregates) asin sunken portion complete all as specified and directed
12Dismantlingof brick tiles single layer on roof, jointed and grouted/pointed in cement mortar including cleaning serviceable tiles and stacking properly for reuse, disposal of unserviceable tiles and debries/rubbles from site complete all as specified and directed.
13Demolition of Mud in roofs , any thickness,including plastering and leeping (whether full thickness removed or only a part thereof complete all as specified and directed.
14M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in roof padding/levelling course complete all as specified and directed.
15M & L for PCC (1:2:4) type B-0 (12.5 mm graded stone aggregates) as in hold fast,roof kerbs,mud stops,rounded or chamfered on edges complete all as directed.
16M & L for applying evenly a tack coat ofindustrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces etc includingAPP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric(wt not less than 150 gms/sqm) laid on roof and sunken portion on bitumen surfaces by forced application including chase cutting in roof and making good with CM(1:4) complete complete all as specified.
17M&L for 40 mm thick brick tiles laid over 15 mm thick screed bed in cement mortar 1:6 and jointed, grouted flush in cement mortar 1:3 mixed 5% of crude oil of by weight of cement on roof padding flush pointing in CM 1:3 complete all as specified and directed
18Description all as per item No 17.00 above but except tiles.
19S&F GI tubing 40mm bore medium grade fixed to wall as sunken spout all as specified and directed
20Material and labour for repairing of RCC projection, chajjas, facia,bands, shelves, beams, RCC railing, balcony and similar works by dismantling of loose/ disintegrated portion of RCC at any height and in any situation floor (including provn of support,formwork and welding of reinforcement if required with wire mesh of weight 3 kg/ sqm and dubbing/ fillingwith PCC (1:2:4), type B-0, using 12.5 mm graded aggregate,15 to 25 mm thickafter applying cement slurry @ 3 kg/sqm, finished even and smooth to desired shapeand applyingtwo coats of painting as existing in building to match with theexisting surfaces complete all as specified and directed.
21Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises.
22S&F non skid ceramiccoloured tiles 7 to 8mm thick (square) size of each tile 400x400mmin floors etc set and jointed in neat cement slurry and pointed in white or coloured pigment to match the shade of tile over and including 15mm thick screed bed in CM 1:6 & complete all as specified and directed.
23S&F non skid ceramiccoloured tilesas in vertical surface for skirting 7 to 8mm thick (square) size of tile 400x400mmin floors etc set and jointed in neat cement slurry and pointed in vertical surfaces white or coloured pigment to match the shade of tile over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
24S&F non skid ceramiccolouredtiles 7 to 8mm thick (square) size oftile exceeding 300x300mm in floors etc set and jointed in neat cement slurry and pointed inwhite or coloured pigment to match the shade of tile over and including 15mm thick screed bed in CM 1:6 & complete all as specified and directed.
25M&L for glazed ceramic coloured tiles of size 450mm x 300mm x 7-8mm thick as in verticale portion such as dado,skirting,riser to steps etc with highlighter border, set &jointed in neat cementslurry and pointed inwhite or coloured cementto match over and includingrendering10mm thick in cement mortar (1:4) , complete all as specified and directed.
26Taking up or down 15mm dia steel tubing and connections andremoval to store all as specified and directed.
27Taking up or down 20mm dia steel tubing and connections and removal to store all as specified and directed.
28S&F 15mm bore tubing medium grade galvanised steel tubing with all fittings and fixed to walls and in floor incl cutting, chasing in wall, floor or ceiling and making good in CM 1:3 complete all as specified and directed.
29S&F 20mm dia GI tubes medium grade with all fitting and fixed complete to walls complete all as specified and directed.
30M & L for applying two coat of undiluted thick coat of acrylic reinforcement liquid as per manufacturer instructions elastorneric water proofing membrane with UV resistance properties and solar refective properties over one coat of primer (1:3, Dilution:water) Note: Every each coat gap between 6 hrs) complete all as specified and directed.
31S & F in repair for viterous china wash hand basin white flat back size 550 x 400 mm incl CP waste coupling, waste pipe & plug and porclain stopper brackets and cutting for and pinning in ends of brackets or erecting stand fixed complete all as specified and directed.
32Supply and fixingvitreous china squatting pan ( Orissa Pattern) size 580 x 440 mm (white), with PVC (SWR) P trap, integral foot rest including water connection to trap and flushing pipe, flushing cistern etc complete andbedding in PCC 1:7:12 type F-2including taking down/dismantling old unserviceable WC complete all as specified. Note :-Flush pipe and flushing cistern to be measured and paid separately.
33S & F in repair for viterous china wash down water closet pan (pedestal pattern) coloured including"P" or "S" trap with flush pipe of chromium plated brass 32 mm dia for low levelflushing cistern incl plastic seat cover white closed pattern with float bottom and cover and jet connection and mild steel chrominum plate or aluminized hanging device fixed complete all as specified and directed.
34S&F in repair 10 Ltr capacity PVC valveless syphonic action type flushing cistern white low level with ball valve flote handle including bracket and flush pipe of polythylene of low or high density or PVC,32mm dia complete all as specified and directed.
35S&Fin repair 450mm long PVC connections with PTMT nuts of suitable for 15mm bore dia pipe complete all as specified and directed.
36S & F in repair for 15mm dia pipe fancy type chromium plated long body bib tap with crutch or butterfly handle screwed down to iron pipe with all fittings complete all as specified and directed.
37S & F in repair for 15mm dia pipe chromium plated Stop cock/Angle cockscrewed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for unions complete all as specified and directed.
38S& F for in repair swan neck pillar cock chromium plated fancy type screw for 15mm bore iron pipe complete all as specified and directed.
39S & F in repair Chromium plated shower rose 125 mm size with or without swivel joints, any size with arms , including fixing to steel pipe or union complete all as specified and directed
40S&F in repair CP Grating125/100/75mm dia with or without hole as per site requirement fixedcomplete with filling of white cement all around complete all as specified.
41M&L for Precast RCC (1:2:4) type B-1 using 20mm graded stone aggregate set in cement mortar 1:6 as in landings,cover slabs for manhole etc,water tank base and similar work complete all as specified and directed including demolition of existing RCC and any formwork.
42Mild steel TMT bars 8 to 10 mm diacut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips , including welding with mild steel completed all as specified and directed.
43S&F in repair sinks with drainage board made of 1mm thick stainless steel sheet for kitchen or laboratory with plugs, washers,wastes coupling,waste pipe including bedding in cement mortar on to wall or including fixing cantilever brackets or chase cut and fixing the sides as required as per site complete with overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as specified and directed.
44S&F rotational moulded polythene, triple layer white colour,water storage tank 500 Ltr capacity, closed top, cylindrical, hoisted and fixed in position includingincluding 20mm bore PTMT ball valve epoxy coated minium weight 210gms with aluminium rod and including dismantling water tanks Exc 250 Ltr & not exceeding 500Ltr complete all as specified and directed
45S&F in repair 15mm borestop cockconcealed as in repair long shank chromium plated fancy type screwed down high pressure with crutch or butter fly handle complete all as specified and directed.
46Supply and fixing in repair PVC waste pipe 32/38/40mm dia, 600 to 750mm long complete all as specified and directed.
47S&F in repair 20 mm bore dia gate valve,gun metal with iron wheel head,screwed both ends and fixed all as specified and directed.
48Taking down eaves gutters and rain water pipes from wall/concealed( any size or pattern) , including all fittings , heads, shoes, bends, swan necks, etc. and removal to store ( measured overall as fixed along the centre line over fittings and accessories)
49S&F PVC (SRW) pipe 110 mm rain water pipe single socketed in any length with rubber ring joints,fixed to wallswith clamps fixed complete all as specified and directed.
50Supply and fixing 110 mm bore PVC (SWR) pipes rain water/drain pipe single socketed in any lengthjoints laid in trenches inclding demolition/Excavation and filling with 1:2:4complete all as specified and directed by Engr-in-charge.
51Supply and fixing 110 mm bore PVC (SWR) bends with access door any radiuscomplete all as specified and as directed.
52Supply and fixing 110 mm bore PVC (SWR) bends of any radius without access door complete all as specified and as directed.
53S&F PVC(SWR) "T" single (equal or unequal) 110 mm dia with access doors complete all as specified and directed
54S&F in repair PVC (SWR) floor trap 110mm plain with grating including jointing with solvent cement
55Demolition Reinforced Cement Concrete as in roof,floors,landings,chajjas,vertical walls and similar suspended/vertical works complete all as specified and directed.
56M&L for RCC type B-1 1:2:4 (20 mm graded aggregate) as in slabs supported on walls,beams,canopies and deck slabs and in shelves and similar structure including any required formwork complete all as specified and directed.
57M&L for RCC type B-1 1:2:4(20mm graded aggregate) as in walls,retaining walls,basement walls,ballast walls and the like, any thickness including any required formwork complete all as specified and directed.
58M&L for steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade st-240complete all as specified and directed.
59Disconnecting existing tanks of capacity exc 250 ltr &n.exc 500 ltr,setting aside(or lowering if required) for repairs,cleaning,etc and hoisted reconnecting and refixing in position including cleaning and removing all scale and dirt etc from tanks and from mouth ofcisculating pipes complete all as specified and directed.
60M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail