Tender For Repair / Maint To Lt External Electrifications, Repair / Maint Of Security/ Perimeter High Mast Lights/ Solar Lights/ Garden Lights And Connected Items And Repair/ Maint Of External Water Supply At Along Mil Stn Under Ge 872 Ews, West Siang-Arunachal Pradesh

Military Engineer Services-MES has published Tender For Repair / Maint To Lt External Electrifications, Repair / Maint Of Security/ Perimeter High Mast Lights/ Solar Lights/ Garden Lights And Connected Items And Repair/ Maint Of External Water Supply At Along Mil Stn Under Ge 872 Ews. Submission Date for this Tender is 30-05-2024. Electrification Work Tenders in West Siang Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43341956
Tender For Repair / Maint To Lt External Electrifications, Repair / Maint Of Security/ Perimeter High Mast Lights/ Solar Lights/ Garden Lights And Connected Items And Repair/ Maint Of External Water Supply At Along Mil Stn Under Ge 872 Ews
Open Tender
Indian
Arunachal Pradesh
West Siang
30-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair / Maint To Lt External Electrifications, Repair / Maint Of Security/ Perimeter High Mast Lights/ Solar Lights/ Garden Lights And Connected Items And Repair/ Maint Of External Water Supply At Along Mil Stn Under Ge 872 Ews

Key Value

Document Fees
INR 500 /-
EMD
INR 59000.0 /-
Tender Value
INR 29.50 Lakhs /-

Attachment

FileName File Description File Size
d81ccbfd-8dbb-42af-8271-de40b5f7b101.html Tender Notice 0 KB
BOQ_731076.xls Tender Document 0 KB
Tender8606.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: REPAIR / MAINT TO LT EXTERNAL ELECTRIFICATIONS; REPAIR / MAINT OF SECURITY/ PERIMETER HIGH MAST LIGHTS/ SOLAR LIGHTS/ GARDEN LIGHTS AND CONNECTED ITEMS AND REPAIR/ MAINT OF EXTERNAL WATER SUPPLY AT ALONG MIL STN UNDER GE 872 EWS
Sl. No. Item Description
1Dismantling of unserviceable broken LT steel pole/Strut any size including demolition of foundation as required and making good disturbed surface complete all as directed. (Note : Earth work wherever invloved shall be measured and paid separately)
2Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside serviceable materials for re-use with in 50m and removing unserviceable materials from site of work incluidng demolition of PCC foundation and taking out base plate etc complete all as directed by the Engr-in-Charge
3Dismantling LT Stay assembly, of any size and unserviceable materials removing from the Site(s), complete all as specified and directed. (Note: (a) Unserviceable Stay assembly shall be taken off/dismantled at Ground Level and making good disturbed ground surface. (b)Earthwork for demolition of cement concrete shall be measured and paid separately under relevant Items of this Schedule.)
4Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
5Excavating in trenches not exc. 1.5 metre wide and exc. 1.5 metre & not exc. 3 metre depth (beyond the first 1.5 metre) for foundation of poles etc and getting out in soft/loose soil complete all as specified and directed.
6Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
7Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting pointcomplete all as specified and directed.
8M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
9M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
10M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
11M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including one coat of aluminium paint over a coat of red oxide zinc chrome primer and providing 03 Nos band/strap with black/yellow colour paint 300mm apart from the plinth block, numbering of pole painting embedded portion of pole with one coat of black bitumenous paint complete all as specified and directed. (Note : Excavation and Earth work shall be measured and paid separately)
12M & L for Cross arms bracing supports clamps and back plates fabricated from structural steel sections including nut bolt washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
13M & L for Stay assembly complete with all accessories as shown in electrical plate No 1 of MES Schedule Part I dia of stay rod 16mm with and including 7 / 3.15 mm galvanised stay strand complete all as specified and directed. (Note : Loop insulator, excavation & earthwork and cement concrete measured and paid separately under relevant items of this Schedule.)
14M & L for loop type insulator, vitreous porcelain, white, brown or green of overall dimension 65 x 90 mm, clearance of hole 25.5 mm etc complete all as specified and directed.
15Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing includingtaking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
16All as per Serial item No. 15 above but for 16 Sqmm 4 core cable complete ditto
17All as per Serial item No. 15 above but for 25 Sqmm 3.5 core cable complete ditto
18All as per Serial item No. 15 above but for 35 Sqmm 3.5 core cable complete ditto
19All as per Serial item No. 15 above but for 50 Sqmm 3.5 core cable complete ditto
20All as per Serial item No. 15 above but for 70 Sqmm 3.5 core cable complete ditto
21S & F outdoor epoxy straight through joint for LT XLPE/PVC insulated cable including all asseccories and connections for 16 Sqmm to 95 Sqmm, 3.5/4 core cable complete all as specified and directed (Excavation and earth work shall be measured and paid seperately)
22M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
23Supply and laying locally available best quality, well burnt sub class B bricks (old size), laid dry in trenches for protection of UG cables complete all as specified and directed.
24S & F in repair MCCB 415 Volt 25 KA, 3 Pole,63 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 43 or equivelant of make as per List of Manufacturer"s)
25S & Fin repairsMCCB 415 Volt,25 KA,4 Pole,100 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4200 55or equivelant of make as per List of Manufacturer"s)
26S & F in repair MCCB 415 Volt, 25 KA, 4 Pole, 160 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4200 57or equivelant of make as per List of Manufacturer"s)
27S & F in repair MCCB 415 Volt, 25 KA, 4 Pole, 200 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4202 18or equivelant of make as per List of Manufacturer"s)
28S & F in repairon load Change over switch, general purpose with side handle, current rating 100Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. (Make: L & T Cat No. CO11000OOOO or equivelant approved make as per list of manufacturer)
29S & F in repairon load Change over switch, general purpose with side handle, current rating 63Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. (Make: L & T Cat No. CO10630OOOO or equivelant approved make as per list of manufacturer).
30M & L for Preparation of old painted surface above the planting depth/PCC coping of steel tubular LT pole upto 11.00 metre long including MS clamps, cable protection pipe, bracket fitted with steet light fittings etc by scraping with steel wire brush and applying one coat of aluminium paint to external surface of poles, MS cross arms, MS clamp, cable protection pipe etc to give even shade including 5 Nos strips painting of 300mm high each around the pole with two different colour (black/yellow) of synthetic enamel paint and numbering of poles complete all as specified and as directed by the Engr-in-Charge.
31M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts,check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
32M & L Earthing complete with copper earth plate electrode 600 mm x 600mm x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with copper earth strip of size 20x3mm by means of bolts, nuts,check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
33Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
34Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing includingtaking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
35S & F in repair LED 60 Watt, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium, IP66 flood light, suitable for highlighting architectural facade and general purpose lighting and with lamp and all accessories including mounting clamps, bolts, nuts and washers and copper conductor cable of suitable size to fittings of suitable length complete all as specified and as directed. (Make: Havell"s Cat No. JETAALBAFLOODLIGHT60W or equivelant of make as per list of manufacturer)
36S & F in repair 25 Watt, 230 Volts AC Post Top Lantern, outdoor type with decorative post top for 360 Degree indirect light, IP 65 protection with impact and corrosion reisitant comp[lete with driver and lamp, fixing accessories and connecting up with suitable copper conductor complete all as specifiedand directed. (Make: Havell"s Cat No. CORALPT25WLED757PSYMTOPC or equivelant of make as per list of manufacturer)
37S & F in repair 20 Watt, 230 Volts AC Post Top Lantern, Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base with driver and lamp, fixing accessories and connecting up with suitable copper conductor complete all as specifiedand directed. (Make: Havell"s Cat No. LHFXBON1TN5Q020 or equivelant of make as per list of manufacturer)
38S & F in repair 30 Watt, 230 Volts AC New generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover havingBottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 with lamp, fixing accessories and connecting up with suitable copper conductor complete all as specifiedand directed. (Make: Havell"s Cat No. ENDURASUNDOWNSL30WLED757PASYBOPC or equivelant of make as per list of manufacturer)
39S & F in repair 45 Watt, 230 Volts AC New generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover havingBottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 with lamp, fixing accessories and connecting up with suitable copper conductor complete all as specifiedand directed. (Make: Havell"s Cat No. ENDURASUNDOWNSL45WLED765PASYBOPC or equivelant of make as per list of manufacturer)
40S & F in repair Street light bracket arm of length not less than 1.2 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp 40x5mm of suitable length, nuts, bolts & washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
41S & F in repairs shock proof, rust proof, fire reterdant, non transperant Kiosk Pole box of size 310x210x120mm made of Negineering Plastic on piece moulded for outdoor type, heavy duty, IP-66 protection, with 4 Nos insulated aluminium bus bar of 60 Amps capacity, mounted on unbreakable insulators, MCB SP 10 Amps complete aluminium lugs of suitable size upto 50 Sqmm including 2 Nos of flat iron 40x3mm clamps with suitable MS nuts, bolts & washers etc and duly powder coated on both sides complete all as specified and directed directed. (Make : HENSEL or equivalent model of make as per list of manufacturer)
42S & F in repair PVC insulated and FRLS PVC Round Sheathed, multi-stranded Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 of size 1.0 Sqmm 3 core nominal cross sectional areacomplete all as specified and directed.
43S & F in repair 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
44S & F in repair 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
45M & L for boring of horizontally holes by manual method under road and dia of hole not exc 100mm without damaging the exsting road, getting out and disposal of excavated soil, etc to a distance not exc. 50 meter from the site of work complete all as directed by Engineer in charge.
46S & F in repairs LED Driver 24 to 36/40 watts as per site requirement complete all as specified and as directed.
47M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia TMT bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
48Taking up or down 15mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
49Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
50Taking up or down 25 or 32 mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
51Taking up or down 40 or 50mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
52Taking up or down 80mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
53Taking up or down 100mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
54Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
55Supply, laying, connection and testing 20mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately)
56Supply, laying, connection and testing 25mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately)
57Supply, laying, connection and testing 100mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately)
58Supply, laying, connection and testing, 20mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
59Supply, laying, connection and testing, 25mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
60Supply, laying, connection and testing, 32mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
61Supply, laying, connection and testing, 63mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
62Supply, laying, connection and testing, 90mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
63S & F in repair Bib taps, medium, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and as directed.
64S & F in repairs, 15 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed.
65S & F in repairs, 20 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed.
66S & F in repair 25 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed.
67S & F in repair 32 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed.
68S & F in repairs, 40 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed.
69S & F in repairs, 50 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed.
70Dismantling joints of flanged pipes in position, including removing old rubber or fibre board gaskets, bolts, nuts. etc. to store complete all as specified and directed
71S & F in repairs, 80mm bore, GI Nipple 150mm long with nuts, bolts and rubber gasket complete all as specified and directed.
72S & F in repair 80mm bore, cast iron butterfly valve, wafer type, flanged and drilled both ends, ISI marked,conforming to IS -13095 including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket and testing complete all as specified and directed.
73S & F 100mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to IS -14846 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket including taking out existing one complete all as specified and directed.
74S & F 80mm bore, cast iron sluice valve, non-rising stem type, both end flanged, class PN 1.6 conforming to IS -14846-2000 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket including taking out/down existing one complete all as specified and directed.luding taking out existing one complete all as specified and directed.
75S & F in repair 80 mm bore, Cast iron Non-return (reflux)valve, flange type with by-pass arrangement suitable for 80 mm dia water mains conforming to IS-5312 Part-I class PN 1.6 complete all as specified and directed.
76M & L for construction of brick masonry valve pit of size 45 cm x 45 cm x 45 cm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made out of 3mm thick MS sheet duly welded with provision of hinges, handle and locking arrangement including 40 x 40 x 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, applying two coats of anti-corrosive paint over a coat of red oxide, zinc chrome primer after preparation of steel & iron surfaces including necessary excavation &earth work in soft/loose soil and demolition of existing one complete as specified and directed all as per relevant TD drawing. (Note : Drawing not attached with the tender document.However, the same can be seen in GE/AGE E/M office during working hours)
77M & L for construction of brick masonry valve pit of size 90 cm x 90 cm x 90 cm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made out of 3mm thick MS sheet duly welded with provision of hinges, handle and locking arrangement including 40 x 40 x 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, applying two coats of anti-corrosive paint over a coat of red oxide, zinc chrome primer after preparation of steel & iron surfaces including necessary excavation &earth work in soft/loose soil and demolition of existing one complete as specified and directed all as per relevant TD drawing. (Note : Drawing not attached with the tender document.However, the same can be seen in GE/AGE E/M office during working hours)
78Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
79S & F Rolled mild steel work as Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and directed.
80S & F Mild steel screw bolts of 5 to 10mm dia of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and n. exc 15cm long complete all as specified and directed.
81M & L for dewatering water from Pressed Steel Storage water tank 50000 Litre capacity on 3.0 m high steel staging, cleaning and removing all mosses, Algae, dirts etc from the walls and floor of water tank, removal of dirty water with sludges and disposed off from the site as diretced, rubbing walls, floor, ceiling surfaces with wire brushes/gunny bags after sprinkling sufficient quantities of bleaching powder and washed thoroughly with fresh water including cleaning of outlet pipes, stop valves, gate valves after taking out pipe lines with stop valves, gate valves etc and all accessoires, re-fixing the same after cleaning including float valves wioth float arm to orginal position, writting letters as "TANK CLEANED ON : DD/MM/YY"(i.e date of cleaning) of size exc 100mm but n.exc 200mm in height and 15mm in wide with white paint on black back ground on the front/road side/face of the tank complete all as specifed and as directed.
82All as per Serial item No. 81 above but 80000 Litre capacity PS water tank complete ditto.
83M & L for Preparation of oldpainted steel internal surfaces of Pressed steel water storage tank of any capacity at a height of 3.0m staging including all connected accessories like GI pipes, valves and other fittings etc by removing rust etc from the surfaces by rubbing with wire brush etc and applying one coat of black bitumenous paint (For drinking purpose) complete all as specified and directed.
84M & L for Preparation of oldpainted steel external surfaces of Pressed steel water storage tank of any capacity at a height of 3.0m staging and Iron Removal plant of any capacity including all connected accessories like steel staging, GI pipes, valves and other fittings etc by removing rust etc from the surfaces by rubbing with wire brush etc and applying two coats of aluminium paint complete all as specified and directed.
85M & L for lifting of Submersible Pump and Motor assembly 7.5 HP capacity alongwith complete Column pipes. Submersible cable, safety rope etc from the existing Borewell by emplying chain pulley block etc, dismantling column pipes by opeining nuts, bolts, pump & motor etc, seggregating & stacking of serviceable column pipes & other materials and keep in safe custody for re-use complete all as specified and diretced.
86M & L for removing submersible pump and motor assembly 7.5 HP capapcity to AGE E/M Store yard, Opening/dismantling and checking in presence of a Board of Officers to ascertain the quantum of defects and repair works involves, cleaning of cover and parts as required, transportation of defective submersible pump and motor assembly to nearest workshop for repairs, repairing and replacement of unserviceable parts and re-assembling submersible pump and motor assembly after repair and servicing and transporting repaired submersible pump motor assembly back to work site complete all as specified and diretced. (Note: (a) Spare Parts required to be replace will be measured and paid as "Supply only"under relevent items and the cost of labour element involved for replacement of parts shall demmed to be included in the unit quoted rate. (b) Any Minor repairs involved to make the submersible pump and motor assembly functional, even if not notified by the BOO, the same shall be carry out by the contractor without any extra cost to the Department. (c) The cost of minor spares parts/ items viz, nuts, bolts, washer, gasket etc shall deemed to be included in the unit quoted rate. (d) Rewinding of submersible motor, herever involves will be measured and paid seperately under relevent item (e) BOO shall be detailed by GE)
87M & L for dismantling of Submersible Motor 7.5 HP capacity, taking out burnt windings, cleaning of slots of the motor and Rewinding the same with water proof super enamelled copper insulated wire of suitable guage and weight as per the existing one including necessary insulation materials, varnishing, heating, reassembling the same and testing for smooth functioning after rewinding complete all as specified and directed by the Engr-in-Charge.
88Supply only PVC insulated, sheathed, flat stranded copper conductor of 6 Sqmm, 3 core, 1100 Volts Grade conforming to IS:694 water proof submersible cable cable complete all as specified and directed.
89M & L for Lowering down of Submersible Pump and Motor assembly 7.5 HP capacity alongwith complete Column pipes. Submersible cable, safety rope etc from the existing Borewell by emplying chain pulley block etc,and T & P, testing on completion complete all as specified and diretced. (Note: Serviceable materials obtained from serial item No. 85 to 88 above shall be reused)
90M & L for Taking out existing Monoblock Pump set, 10 HP capacity, Opening strip of pump set and removing Mono block Pump set to AGE E/M Store yard, opening and checking, cleaning of pump set as required, transportation of defective Pump set to nearest workshop to carry out reparing/rewinding, dismantling pump set, taking out burnt copper windings, cleaning of slots of the motor, re-winding the same with supper enamlled copper insulated wire of suitable gauge and weight as per the existing one including necessary insulation materials, varnishing, heating, replacement of minor spares/ parts such as nuts, bolts, washer, gasket etc and repalcement of ball bearings etc with new one as per the existing one, greasing etc re-assembling the same and testing for smooth functioning after re-winding, transporting back to worksite after repair, re-installation and providing all connection, testing in presence of Engr-in-Chargecomplete all as specified and diretced. (Note: Ball bearing etc as required shall be measured and paid seperately as supply only under relevant item)
91All as per Serial item No. 90 above but for 20 HP capacity Monoblock Pump set complete ditto
92Supply only Ball bearing No 6203 suitable for Monoblock Pump set, 10/20 HP capacity complete all as directed (Make : TATA/SKF/NBC/HCH).
93Supply only Ball bearing No 6208 suitable for Monoblock Pump set, 10/20 HP capacity complete all as directed (Make : TATA/SKF/NBC/HCH).
94M & L for Preparation of oldpainted steel external surfaces of Monoblock pump set 10/20 HP capacity including all connected accessories and other fittings etc by removing rust etc from the surfaces by rubbing with wire brush etc and applying two coats of synthetic enamelled paint (1st Grade quality) by spray painting machine complete all as specified and directed.
95S & F in repair of water pressure gauge diaphram type range 0-7 Kg/Sq cm, 100 mm dia complete all as directed by Engineer-in-Charge.
96Supply only High strength calcium Hypo Chloride, 65-70% chlorine content, Calcium based granular disinfectant for water treatment chemical complete all as specified and directed. (Note: Make shall be as per approved makes of E-in-C. Testiting certifcate of chemical shall be submitted by the contractor before supply).
97S & F in repair Fully automatic star delta starter, 10 HP, 415 Volts, 50 Hz with outgoing and incoming cable connections and testing on full load complete all as specified and directed. (Make: C & S/Havell"s/L&T or equivelant as per list of manufacturer)
98S & F in repair Fully automatic star delta starter, 20 HP, 415 Volts, 50 Hz with outgoing and incoming cable connections and testing on full load complete all as specified and directed. (Make: C & S/Havell"s/L&T or equivelant as per list of manufacturer)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy