Tender For Replacing Of Damaged Stp And Drinking Water Pipe Line In Shaft Of Cluster 1, 2, 4, 6 And 7 At Rajiv Gandhi Girls Hostel Dhaka Complex, University Of Delhi., Delhi-Delhi

Delhi University has published Tender For Replacing Of Damaged Stp And Drinking Water Pipe Line In Shaft Of Cluster 1, 2, 4, 6 And 7 At Rajiv Gandhi Girls Hostel Dhaka Complex, University Of Delhi.. Submission Date for this Tender is 29-05-2024. Water Pipe Line Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43340468
Tender For Replacing Of Damaged Stp And Drinking Water Pipe Line In Shaft Of Cluster 1, 2, 4, 6 And 7 At Rajiv Gandhi Girls Hostel Dhaka Complex, University Of Delhi.
Open Tender
Indian
Delhi
Delhi
29-05-2024

Tender Details

Replacing Of Damaged Stp And Drinking Water Pipe Line In Shaft Of Cluster 1, 2, 4, 6 And 7 At Rajiv Gandhi Girls Hostel Dhaka Complex, University Of Delhi.

Key Value

Document Fees
INR 500 /-
EMD
INR 19838.0 /-
Tender Value
INR 9.91 Lakhs /-

BOQ Items

Name of Work: Replacing of damaged STP and drinking water pipe line in shaft of Cluster 1, 2, 4, 6 and 7 at Rajiv Gandhi Girls Hostel Dhaka Complex, University of Delhi.
Sl. No. Item Description
1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
21:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
31:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
4Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
5Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
6Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
7Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore
8Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
9Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
1020 mm nominal outer dia Pipes
1125 mm nominal outer dia Pipes
1232 mm nominal dia Pipes
1340 mm nominal dia Pipes
1450 mm nominal dia Pipes
15Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 65 mm nominal dia Pipes
16Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
1725 to 40 mm nominal bore
1850 to 80 mm nominal bore
19Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :
2020 mm dia nominal bore
2125 mm dia nominal bore
2232 mm nominal bore
2340 mm nominal bore
2450 mm nominal bore
2565 mm nominal bore
26Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. (non modular) bricks
27P/F CPVC Ball Valve 25 mm dia. of approved quality(Supreme make)
28P/F CPVC Ball Valve 32 mm dia. of approved quality(Supreme make)
29P/F CPVC Ball Valve 50 mm dia. of approved quality(Supreme make)
30P/F CPVC Ball Valve 65 mm dia. of approved quality(Supreme make)
31P/F CPVC F.T.A./ M.T.A. (Brass Insert)with reducer sokit 25 mm dia. of approved quality (Suprimemake)
32P/F CPVC F.T.A./ M.T.A. (Brass Insert)with reducer sokit 32 mm dia. of approved quality (Suprimemake)
33P/F CPVC F T A/ M T A (Brass Insert) with reducer sokit 50 mm dia. of approved quality(Supereme make)
34P/F CPVC F T A/ M T A (Brass Insert) with reducer sokit 65 mm dia. of approved quality(Supereme make)
35Surching and repair the damaged GI pipe line with excavation trenches and charge for labour, repair with GI fittings etc complete as per direction of Engineer –in-charge (40 to 50 mm dia nominal bore)