Tender For The Work To Reconstruction Of 11 Kv /Lt Lines Fallen Due To Natural Disaster/ Heavy Strom At 33/11 Kv SubstationS Under Eudd Hathras., hathras-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Tender For The Work To Reconstruction Of 11 Kv /Lt Lines Fallen Due To Natural Disaster/ Heavy Strom At 33/11 Kv SubstationS Under Eudd Hathras.. Submission Date for this Tender is 14-05-2024. Overhead Line Tenders in hathras Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43337492
Tender For The Work To Reconstruction Of 11 Kv /Lt Lines Fallen Due To Natural Disaster/ Heavy Strom At 33/11 Kv SubstationS Under Eudd Hathras.
Open Tender
Indian
Uttar Pradesh
hathras
14-05-2024

Tender Details

Tender For The Work To Reconstruction Of 11 Kv / Lt Lines Fallen Due To Natural Disaster / Heavy Strom At 33 / 11 Kv SubstationS Under Eudd Hathras.

Key Value

Document Fees
INR 1180 /-
EMD
INR 5000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work :Thework to reconstruction of 11 KV /LT lines fallen due to Natural Disaster/ Heavy Strom at 33/11 KV Substation"s Under EUDD Hathras.
Sl. No. Item Description
1Safe Carriage of following material from Electricty store center Hathras to Pit site of work through the Kacha and Pakka road includingloading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-50 Kms.)
28.5 Mtr. long PCC Poles.
39/11 Mtr. S.T. Poles
411 KV X-Arms, weasal conductor, G.I wire,Disc Insulators, Pin insulators, clamps and otherrequired line material, if any.
5Safe Carriage of following from Electricty Store center Hathras to Pit Site of Work through the Kacha and Pakka roadloading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-70 Kms.)
616 KVA T/F
725 KVA T/F, 63 KVA T/F, 100 KVA T/F
8Replacement of damaged 8.5 Mtr. long PCC pole by digging of pits in kharanja/mettalic road and dismantling of all 11KV/LT accessories from the existing / damaged pole and errection of single new pole including Fixing of all accessories.
9Replacement of damaged 9/11 Mtr.Long ST pole by digging of pits in kharanja/mettalic road and dismantling of all 11KV/33 KV accessories from the existing / damaged pole and errection of single newSTP pole including Fixing of all accessories.
10Replacementof damaged 8.5 meter long of Double PCC Pole (first opening of all accessories & then removing damaged poles),under Errection D/P includingfixing of Disc Insulators with fitting and other LT/11 KV accessories as per RESPO manual and as per direction of supervising engineer, The double pole shall be grouted in ratio 1:4:8 (Cement, sand and brick ballast/ stone ballast)including cost of cement, sand, brick ballast/ stone ballast, stone pad as per actual requirement at site
11Replacementof damagedDouble pole on 9/11 meter long of Double ST Pole (first opening of all accessories & then removing damaged poles), re-erecting D/P includingfixing of Disc Insulators with fitting and other 11 KV/ 33KV accessories as per RESPO manual and as per direction of supervising engineer. The double pole shall be grouted in ratio 1:4:8 (Cement, sand and brick ballast/ stone ballast)including cost of cement, sand, brick ballast/ stone ballast, stone pad as per actual requirement at site
12Straightening of tilted single PCC Poles in the existing lines as per direction of supervising engineer.
13Straightening of tilted single ST Poles in the existing lines as per direction of supervising engineer.
14Straightening of tilted Double Poles in the existing lines as per direction of supervising engineer.
15Replacement offollowing damaged accessories in 11 KV /LTline -
1611 KV X-Arms, 11 KV Pin Insulators with Pin &Nut &Bolt , "F" Clamp
1711 KV Disc Insulator With Fiting
18Errection and grouting of stays as per RESPO Norms and as per direction of supervising engineer with Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
19Fixing of earthing rod as per RESPO Norms and as per direction of supervising engineer.
20Laying, sagging and stringing and Nozzling / binding etc. ofnew &old ACSR Weasal conductor / GIin 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer.
21ACSR Weasel conductor
22ACSR Dog / Racoon Conductor
2350/95/120 sqmm. Areal Bunch Conductor
24Re- sagging and stringing of existing following conductor in HT /LT line as per direction of supervising engineer.
25ACSR Weasel conductor
2650/95/120 sqmm. Areal Bunch Conductor
27ACSR Dog Conductor
28Cutting, chopping, triming of tree branches to clear the line route to give2 mtr. horizontal and vertical clearance to the line coming in the route ofdifferent feeders as per direction of supervising engineer
29Safe Installation offollowing New/Repaired cousted T/F on newly constructed double pole in proper alignment direction & making all HT/LT connection.
3016 KVA T/F
3125 KVA T/F, 63 KVA T/F, 100 KVA T/F
32Re Guarding / Guarding of 11 KV line by laying, stringing, sagging and binding of 2 Nos. parallel GI wire 6 SWG after providing, fabrication and fixing of guarding angle and fabrication and fixing of X-guards (Tillis) of GI wire at distance of 3 Mtr.
33Digging of proper size of pit for following work of damaged steel support with the provision of temporary support :- Then reinforcement of steel support by welding of 04 Nos. 2 feet long M.S. angle iron of 50x50x6 mm. at equal distance around each pole & also welding of these angle iron with each other by providing M.S. flat of size 35x6 mm. in round. After this construction of round plinth of pole will be done with cement, sand and concrete in 1:3:6 ratio of size 450 mm. dia & 600 mm height (300 mm. under the ground + 300 mm. the ground). The plinth should be plastered with ½ inch thick cement and sand of ratio 1:4 & taper rounding the upper most part of the plinth. The rate will include all cost of material, labour and T&P etc. for completion of the above work which will be provided by the contractor at his own cost.
34Construction of round plinth around the S.T. Poles / RS Joists / Rails will be done with cement, sand and concrete in 1:3:6 ratio of size 450 mm. dia & 600 mm height (300 mm. under the ground + 300 mm. the ground). The plinth should be plastered with ½ inch thick cement and sand of ratio 1:4 & taper rounding the upper most part of the plinth. The rate will include all cost of material, labour and T&P etc. for completion of the above work which will be provided by the contractor at his own cost.
35Video graphy before & after works and GIS Cordinate