Delhi Development Authority-DDA has published Maintenance Of Of Work Pertaining To Completed/Closed Scheme Dwarka Zone. Sh:- Sh 1:-Repair Maintenance Of Clear Water Booster Pump Sets & D.G. Set At Marble Market, Sector-20, Dwarka. Sh 2:-Repair Maintenance Of Clear Water Booster Pump Sets & D.G. Se. Submission Date for this Tender is 20-05-2024. Electrification Work Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 09-May-2024 | Corrigendum | Other | 20-05-2024 |
FileName | File Description | File Size |
0b57e69e-4bd8-4ef1-b962-bc188798d5a0.html | Tender Notice | 0 KB |
BOQ_847841.xls | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Tendernotice_2.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | Running, maintenance & operation of clear water booster pump set & D.G.sets along with IEIcontrol Panel & compound lightings as per inventory, terms and conditions attached by deploying following staffs:-a) Operator Gr-II - 02 Nos. from 6:00AM to 2:00PM & 2:00 PM to 10:00PM(b)Khallasi-2Nos from 10:00PM to 6:00AM(c)Wireman Gr-I shall attend the sites between 9:00AM to 5:00PM at least once in a fortnight and as when required. (For SH 1 & SH 2 and SH 3 i.e Both the Pump houses and public Toilets 1,2 & 3) |
2 | Dismantling and reparing/rewinding & supplying and replacement of following parts of existing5HP, 3 phase Monoblock induction motor of existing make couple with5HP centrifugul pump i/c re-assembling/re-installation the same, connection with testing etc. completed as reqd. (for SH-1)Motor (i) Rewinding ofmotor 5 HP motor----1Job. (ii) S/R Ball bearing no. 6204,6307 ------ 1set Each. (iii) S/R Gland Bush------ 1 Nos. (iv) Rotor Balancing turning ------ 1 No. (v) S/R bearing bush ------2 Nos. vi) S/R Gland plates--------- 1 No vii) Labour charges for dismentling + cartage etc. |
3 | Dismantling and reparing & supplying and replacement of following parts of the existing 5 Hp Vaccum Pump Set i/c re-assembling/re-installation the same, connection with suction and delivery line, valves, testing etc. completed as reqd. (for SH-1) (i)Remetling, Repairing of pump shaft i/c turning,granding etc ------1 Job. (ii) S/R Ball, BearingNo- 6207------2 Nos. (iii) S/R Gland Plates------2 Nos. (iv) S/R of Gland sleeves------ 1 Set. (v)Chuck Nut ------1 Set. (vi) Polishing of Impeller------ 1 Job.(vii) worm out Nut Stud packing 1 Lot, nut ,bolt etc.-------- 1 Lot(viii) Labour charges for dismentling + cartage etc.. |
4 | Dismantling and reparing/rewinding & supplying and replacement of following parts of existing induction motor 3 Phase of existing make couple with 15HP centrifugul pump i/c re-assembling/re-installation the same, connection with testing etc. completed as reqd. (for SH-2)Motor(i) Rewinding of 15 HP motor i/c varnishing backing etc complete asrequired ---- 1 Job. (ii) S/RBall bearing no. 6309------ 2 Nos. (iii) S/R ofConnectingPlate ------ 1 Nos. (iv) Rotor Balancing turning ------ 1 No. (v) S/R bearing bush ------2 Nos.vi) S/R of cooling fan -----------1 No(vii) Labour charges i/c cartages etc. |
5 | Dismantling and reparing & supplying and replacement of following parts of centifugal pump of existing make couple with 15HP motor i/c re-assembling/re-installation the same, connection with suction and delivery line, valves, testing etc. completed as reqd. (for SH-2) Pump (i) Remetling, Repairing of Pump Shaft i/c Turnning,granding etc ------ 1 Job. (ii) S/R Ball Bearing No-6309 ------2 Nos. (iii) S/R gland sleevess------2 Nos. (iv) S/R Gland plates------ 2 Nos. (v) Balancing of Impeller -----1 Job (vi) R/o Wormout hardwareNut Stud etc--1 Job.(vii) Labour charges i/c cartages etc. |
6 | Dismantling and reparing & supplying and replacement of following parts of 1.5HPdewatering Pump i/c re-assembling/re-installation the same, connection with suction and delivery line, valves, testing etc. completed as reqd. (for SH-2) (i) Rewinding of Motor etc ------ 1 Job. (ii) S/R Ball Bearing Set ------1 Set. (iii) Mechanical Seal------1 Set. (iv) "O"Ring Set------ 1Set. (v) Labour charges i/c cartages etc. |
7 | Servicing of 25 KVA DG Set of kirloskar Make i/c replacement of following parts:- (for SH-2) (i)Diesel Filter Set - 1 Set (ii) Oil Filter- 1 set (iii)Air Filter- 1Set iv)Coolant -5 Ltrs v)Engine Oil --- 13 Ltrs vi) Battery 110 Ah 12 V---- 1 Setvii) Battery Wire Set---1 Set viii) 12 V Self Starter Repairing with Parts--- 1 Job ix) Control Card ---- 1 Set (x) Service and Labour Charges |
8 | Supply and replacement of MN 16 DOL stateri/c connection of the same etc complete as required at site. |
9 | Supplying & Replacement of LED Streetlight fitting i/c suitable arm bracket (IP 66 protection) of 45 W complete in all respect i/cmaking connections ,earthing the same and to meet the requirement as per technical specifications etc. as required. |
10 | Supply,Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
11 | Supply and replacement of following accessories i/c testing etc complete as required.a) 20 watt 4 ft light LED batten Complete fitting. |
12 | (b) 9 watt 2 ftlight LED batten Complete fitting. |
13 | (c) 63A four Pole MCB |
14 | (d) 3 Pin 5A ,Ceiling Rose |
15 | (e )1.5 Sq.mm wire |
16 | (f) 4 Sq.mm Wire |
17 | Rewiring for light point/fan point / Exhaust fan with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLC PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel /PVC conduiit i/c dismantling as required. a) Group C |
18 | Supplying andreplacement of following Piano type switch/socket on the existingcover plate & switch box including connections etc. as complete as required. a)5/6 A Switch |
19 | b)5/6 A Socket outlet |
20 | c) 15/16 A Switch |
21 | d) 15/16 A socket outlet |
22 | Supplying and replacement5A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole |
23 | (b) Double Pole |
24 | (c) Three Pole & Neutral |
25 | Supply,replacement and fixing of 3 mm thick phenolic laminated sheetin suitable size as requiredat site in givenGI box i/c testing etc complete as required. |
26 | Supplying and fixing of following sizes of XLPE insulated of 1.1 KV Grade Al. cond. armoured power cable including connection, testingetc. as complete required at site. a)2C x16 sq. mm. |
27 | Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. (a) Upto 35 Sq.mm (Clamped with 1mm thick saddle) |
28 | Supplying and replacementof following 25 mm sizes of medium Class PVC Conduit along with accossories in surface/recess including cuttng the wall and making good the same in case of recessed conduit as required. |
29 | Supply of 10 Sq. mm FRLS PVC insulated single core copper wire i/c connection etc completed as required. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy