Assam Rifles-AR has published Tender For The Work Provision Of Allied Services At Laitkor. Submission Date for this Tender is 23-05-2024. Civil Work Tenders in East Khasi Hills Meghalaya. Bidders can get complete Tender details and download the document.
FileName | File Description | File Size |
01e9b3f9-74f0-42c6-bb88-cca6f1381502.html | Tender Notice | 0 KB |
BOQ_847810.xls | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | SCHEDULE ‘A’ PART-I (SCHEDULE OF ITEMS) PROVN OF 750KVA DG SET WITH ALLIED WORKS AT HQ DGAR ADM BLOCK, LAITKOR |
2 | Supply, installation, testing and commissioning of DG SETS, AMF Panel, BUS DUCTING/Cable from DG Sets to essential panel, DG set enclosure room sound insulation /ventilation/smoke exhaust as required, earthing of DG set system, control cabling, fuel tank/piping, Dg set exhaust chimney as per CPCB norms, civil working connected with DG sets including foundation as required. |
3 | M&L for fabrication of outdoor type electrical panel board (CPRI approved) 415 volt ,3 phase, 4 wire system ,cubical, dust and vermin proof with base framemade out of CRCA sheet of 3.15 MM thickof size 1650X1650X800MM with both sideopening double door system with locking arrangement,aluminium bus bar suitable for 1200 amp capacity and half for neutral on PVC/FRPinsulated pads and panel board duly painted with two coat of metal powder coated paint of goodapproved qualityincluding digital metering , volt meter selector switches, power indicator RYB LED lamps and Current Transformerof suitable ratio with consisting the following electrical fitment and making space and mounting arrangement for incoming/outgoing switch gears including necessary fixing/grouting arrangement onfloor and trench and connecting all the disconnected underground power cables including lugging and ,crimping and cable glands where ever requires with testing and commissioningto the entire satisfaction ofEngr-in-Charge :-embeded in PCC 1:4:8 type D-2 using 40mm graded stone aggragate of foundation as per manufacture instruction complete all as specified and directed comprising of thefollowing controls. i) ACB 1250Amps 4PoleMicroprcessor Release IPR 1+ (Main Incoming)-01No. ii) ACB 800Amps 4PoleMicroprcessor Release IPR 1+ (Outgoing)-02 Nos. iii) MCCB 400 Amps 3Pole LN Frame : Adjustable thermal & Fixed MagneticIcs 100% of Icu36KA (Frame LS) Make: Havells-02Nos. iv) MCCB 250 Amps 3Pole LN Frame : Adjustable thermal & Fixed MagneticIcs 100% of Icu36KA (Frame LS) Make: Havells-02Nos. v)MCCB 160 Amps 3Pole LN Frame : Adjustable thermal & Fixed MagneticIcs 100% of Icu36KA. Make: Havells-01 No. vi) Volt Meter (o to 500Volt)-05Nos. vii) Amper Meter (0 to 1250Amps)-05Nos viii) CT 1250/5A, Tape wounded, Cl-1-03 Nos. ix)Selector Switch-10Nos .x) Indicator Lamp -03Nos (Note : CPRI approved make) |
4 | Supply,only ARMOURED XLPE CABLE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of size3.5Core 400 sq mm Make : Havells/ Polycab/ Gloster/ KEI |
5 | all as above item but 3.5Core 300Sqmm Make : Havells/ Polycab/ Gloster/ KEI |
6 | all as above item but 3.5Core 240Sqmm Make : Havells/ Polycab/ Gloster/ KEI |
7 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in Open/, Wall/ ground including excavation, sand cushioning, protective covering GI Pipe and size as per site requirement and refilling the trenchabove 185Sqmm up to 400 Sqmm complete all as specified and Directed by Engr-In-Charge.Note: As Per Site Condition laying of Cable Open/Wall/Trench |
8 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Complete all as specified and directed by Engr-in-Charge. |
9 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.Complete all as specified and directed by Engr-in-Charge. |
10 | SCHEDULE ‘A’ PART-II (SCHEDULE OF ITEMS) PROVN OF EXTERNAL WATER & ELECTRIC SUPPLY FOR ARMH AT LAITKOR GRN |
11 | Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of capacity upto 250 KVA(Note : Incl base foundation) |
12 | Supply and installation of copper wound transformer step up/ step down, indoor/outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacityabove 200 KVA and up to 300 KVA. Note : Incl base foundation |
13 | Supply, only for ARMOURED XLPE CABLE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size3 core 120Sqmm. Make : Havells/ Polycab/ Gloster/ KEI |
14 | Laying of one number PVC insulated and PVC Sheathed/XLPE power Cable of 11KV grade of size up to 120Sqmm direct in ground including excavation, sand cushioning, protective covering, GI pipe, size as per site requirement and refilling the trench etc as required. |
15 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 sqmm. Make: as per sample. |
16 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required and Earth pit chamber . Noted : Copper Earthing for DG set and Transformer). |
17 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required complete all as specified and Directed by Engr-In-Charge. |
18 | Supplying and making cable route marker with cement concrete 1.2.4 (1 cement: 2 Coarse sand: 4 grades stone aggregate 20mm nominal size) of size 60cm x60cm at the bottom and 50cm x 50cm at the top with a thickness of 10cm including inscription duly engraded as required. |
19 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in Open/, Wall/ ground including excavation, sand cushioning, protective covering and refilling the trench 35 TO 95Sqmm complete all as specified and Directed by Engr-In-Charge.Note: As Per Site Condition laying of Cable open/Wall/Trunch |
20 | above 95Sqmm and upto 185Sqmm |
21 | Above 185 sq. mm and upto 400 sq. mm |
22 | Supply,only ARMOURED XLPE CABLE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of size3.5Core 240 sq mm Make : Havells/ Polycab/ Gloster/ KEI |
23 | all as above item but 3.5Core 95Sqmm Make : Havells/ Polycab/ Gloster/ KEI |
24 | all as above item but 3.5Core 50Sqmm Make : Havells/ Polycab/ Gloster/ KEI |
25 | M&L for fabrication of outdoor type electrical panel board (CPRI approved) 415 volt ,3 phase, 4 wire system ,cubical, dust and vermin proof with base framemade out of CRCA sheet of 2 MM thickof size 1650X1650X800MM with both sideopening double door system with locking arrangement,aluminium bus bar suitable for 800 amp capacity and half for neutral on PVC/FRPinsulated pads and panel board duly painted with two coat of metal powder coated paint of goodapproved qualityincluding digital metering , volt meter selector switches, power indicator RYB LED lamps and Current Transformerof suitable ratio with consisting the following electrical fitment and making space and mounting arrangement for incoming/outgoing switch gears including necessary fixing/grouting arrangement onfloor and trench and connecting all the disconnected underground power cables including lugging and ,crimping and cable glands where ever requires with testing and commissioningto the entire satisfaction ofEngr-in-Charge :-embeded in PCC 1:4:8 type D-2 using 40mm graded stone aggragate of foundation as per manufacture instruction complete all as specified and directed comprising of thefollowing controls. i) MCCB 630Amps 4Poleof Adjustable Thermal & Fixed Magnetic, 415 Volt, 50 KA rms of breaking capacity 75%Frame LN (Main Incomer).-01No. ii) MCCB 400 Amps 4Pole LN Frame : Adjustable thermal & Fixed MagneticIcs 100% of Icu36KA (Frame LS) -01No. iii) MCCB 250 Amps 4Pole LN Frame : Adjustable thermal & Fixed MagneticIcs 100% of Icu36KA (Frame LS)-02 Nos. iv) MCCB 160 Amps 4Pole LN Frame : Adjustable thermal & Fixed MagneticIcs 100% of Icu36KA-01No. v) Volt Meter (o to 500Volt)-04Nos. vi) Amper Meter (0 to 800Amps)-04Nos vii) CT 630/5A, Tape wounded, Cl-1-03Nos. viii) Selector Switch -08Nos.ix) Indicator Lamp-03Nos (Note : CPRI approved) |
26 | Providing and fixing G.I. pipes of 50mm dia complete with G.I. fittings including trenching and refilling and takingout of old unsv pipe with complete all as specified and directed by Engr-in-Charge Make: Jindal/ TATA/ Surya Prakash/ Nezone |
27 | Providing and fixing G.I. pipes of 40mm dia complete with G.I. fittings including trenching and refilling and takingout of old unsv pipe with complete all as specified and directed by Engr-in-ChargeMake: Jindal/ TATA/ Surya Prakash/ Nezone |
28 | Providing and fixing G.I. pipes of 25mm dia complete with G.I. fittings including trenching and refilling and takingout of old unsv pipe with complete all as specified and directed by Engr-in-Charge Make: Jindal/ TATA/ Surya Prakash/ Nezone |
29 | M&L for Bronze Gate Valve (Screwed) 50mm dia Make: Jindal/ TATA/ Surya Prakash/ Nezone |
30 | M&L for Bronze Gate Valve (Screwed) 40mm dia Make: Jindal/ TATA/ Surya Prakash/ Nezone |
31 | M&L for Bronze Gate Valve (Screwed) 25mm dia Make: ISI marked. |