Tender For Repairs/Replacement Of Ee Led Fittings Incl Internal Wiring/ Distribution Boxes,Repairs To Cooling Appliances,Repairs/ Rplmt Of Old Unsv Ug Cables, Street Light Poles/Fittings Incl Maint Of Transformers/ Standby Dg Set At Icgs Kamorta, Ins Ka, Nicobars-Andaman And Nicobar Islands

Military Engineer Services-MES has published Tender For Repairs/Replacement Of Ee Led Fittings Incl Internal Wiring/ Distribution Boxes,Repairs To Cooling Appliances,Repairs/ Rplmt Of Old Unsv Ug Cables, Street Light Poles/Fittings Incl Maint Of Transformers/ Standby Dg Set At Icgs Kamorta, Ins Ka. Submission Date for this Tender is 25-05-2024. Electrification Work Tenders in Nicobars Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

43332687
Corrigendum : Tender For Repairs/Replacement Of Ee Led Fittings Incl Internal Wiring/ Distribution Boxes,Repairs To Cooling Appliances,Repairs/ Rplmt Of Old Unsv Ug Cables, Street Light Poles/Fittings Incl Maint Of Transformers/ Standby Dg Set At Icgs Kamorta, Ins Ka
Open Tender
Indian
Andaman And Nicobar Islands
Nicobars
25-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repairs / Replacement Of Ee Led Fittings Incl Internal Wiring / Distribution Boxes, Repairs To Cooling Appliances, Repairs / Rplmt Of Old Unsv Ug Cables, Street Light Poles / Fittings Incl Maint Of Transformers / Standby Dg Set At Icgs Kamorta, Ins Kardip

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-May-2024 DATE EXTENDED Date 25-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

Attachment

FileName File Description File Size
b6ee6a9f-08ef-420c-a014-0d5c882b34a1.html Tender Notice 0 KB
8133TENDER.pdf Tender Document 0 KB
BOQ_730877.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: REPAIRS/ REPLACEMENT OF EE LED FITTINGS INCLUDING INTERNAL WIRING/ DISTRIBUTION BOXES, REPAIRS TO COOLING APPLIANCES,REPAIRS/ REPLACEMENT OF OLD UNSV UG CABLES, STREET LIGHT POLES/FITTINGSINCLUDING MAINTENANCE OF TRANSFORMERS/ STANDBY DG SET AND OTHER CONNECTED ACCESSORIES AT ICGS KAMORTA AND INS KARDIP UNDER GE(I) CAMPBELL BAY
Sl. No. Item Description
1Maintenance and servicing, overhauling to DG set including attending faults on call basis for normal repairs including replacement of defective and worn out minor filters gaskets, V- belts, engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolant levels of capacity upto 250 KVA DG set installed at various locations complete all as specified and as directed by Engr- in- Charge Note:- (i)Spares required for maintenance will be measured and paid separately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iii)Work shall be carried out at site at different location Details of Plants :- (a)160 KVA DG Set- 02 Nos
2Servicingand cleaning ofradiator a of DG Sets of capacity from 63 KVA to 160 KVA completeincluding taking out properly complete all as specified and as directed.
3Servicing of self startor of DG Sets of capacity from 63 KVA to 160 KVA completeall as specified and as directed.
4Supply only the following Items of DG Sets of capacity from 63 KVA to 160 KVA to incorporate against each Item ofSchedule "A"here-in-above (a) Engine Oil Filter Assembly.
5(b) Fuel Filter Assembly
6(c) Air Filter Assembly
7(d) Engine Oil
8(e) Coolant
9M & L for removing defective AVR from Alternator and replacing with new AVR upto 160 KVA DG sets of make as per existing complete all as specified and directed by Engr-in-Charge.
10M & L for replacing the old unserviceable battery lead with copper terminals approximately 2.5 mtr length including applying jelly over the battery pole and terminals complete all as specified and as directed by Engr-in-Charge.
11M & L for replacing the old unserviceable battery terminals (Positive & Negative ) including brazing work andapplying jelly over the battery pole and terminals complete all as specified and as directed by Engr-in-Charge.
12Taking down theexisting worn out Fanbelt (V Belt) for DG of 160KVA capacity installed at various installation and replaced with new fan belt complete all as specified and directed by Engr-in-Charge.
13S & F Battery 12 V 180 AH for DG set complete all as specified and directed by Engr-in-Charge. Make :AMCO /KIRLOSKAR /EXIDE XPRESS /AMARAJA
14Taking down the existing Volt meter /Ammeter /Frequency Meter of any capacity DG set from the panel board and replace with new digital Voltmeter/ Ammeter /Frequency Meter including necessary wiring and wiring material all as specified and directed by the Engineer-in-charge. Make:AE/MECO
15Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
16Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soil all as specified and as directed.
17Removing excavated material (soil) to a distancen.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and as directed.
18M & L XLPE, insulated, armoured, heavy duty, electric cable of cross sectional area of size 3.5 Core x 150 Sqmm with stranded aluminium conductors, 1100 volts grade, laid in tranches / fixing on wall /poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, including taking down existing unserviceable cable with GI protections pipes, complete all as specified and as directed by Engr-in-Charge. Make : Havells / Polycab / Finolex / Gloster
19Description all as per Item No 14 above but of cross sectional area of size 3.5 Core x 70 Sq mm complete all as specified and as directed by Engr-in-Charge. Make : Havells / Polycab / Finolex / Gloster
20Description all as per Item No 14 above but of cross sectional area of size 2 Core x 16 Sq mm complete all as specified and as directed by Engr-in-Charge. Make : Havells / Polycab / Finolex / Gloster
21Description all as per Item No 14 above but of cross sectional area of size 2 Core x 6 Sq mm complete all as specified and as directed by Engr-in-Charge. Make : Havells / Polycab / Finolex / Gloster
22S & F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP protection of IP-67 having outer dia 120 mm and inner dia of 103 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed.
23S & F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 50 mm and inner dia of 38 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed.
24S & F GI pipe 50mm bore light grade with all fittings laid in trenches /on wall / on poles etc/ for protection complete all as specified and as directed.
25Supply and installation LED 45 W Street Light, IP-66 (Waterproof) Outdoor Light, Cool White with BIS approved driver, heat management with aluminum heat sink, with protections available -short circuit, open circuit, under voltage, over voltage, insolution, 6kv - internal surge protection complete all as specified and as directed. Note : Necessary 20 mm PVC conduit & 1.5 Sq mm 3 core PVC sheathed PVC insulated copper cable upto 5 m is deemed to be inclusive in quoted rate. Make : - Philips / Bajaj / Wipro/Havells
26Repair of bollard light fittings including replacement minor spare parts complete all as specified and as directed by Engr-in-Charge.
27S & Fdriver for LED flood light fittings of capacity upto 150watts complete all as specified and as directed.
28S & F driver for LED street light fittings of capacity upto 70 watts complete all as specified and as directed.
29Supply and installation LED 150 W Flood Light, IP-66 outdoor light, cool white with BIS approved driver, heat management with aluminum heat sink, with protections available -short circuit, open circuit, under voltage, over voltage, isolution, 6kv - internal surge protection complete all as specified and as directed. Make : - Philips / Bajaj / Wipro//Havells
30S & F post top lantern LED type 35 watt, 230volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
31S & Fbollard type LED type, 10 watt, 300 lumens, warm white, 230 volts AC outdoor type with decorative bollard light IP 65, IK10 impact protection with impact and corrosion resistantwith driver and lamp complete all as specified and as directed.
32S & FPVC junction box of size140 x 140 x 95 mm, light weight pole mounting hinged type including necessary clamp for MCB mounting and mounting of box on pole /pipe with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as specified and as directed. (ForPost Top Lantern) Make : Sintex / Hensel/ OBO
33S & F PVC junction box of size270 x 225 x 135 mm, light weight pole mounting hinged type including necessary clamp for MCB mounting and mounting of box on pole /pipe with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as specified and as directed (For Street Light Pole &Flood light) Make : Sintex / Hensel/ OBO
34M & L for preparation of old painted surfaces of steel tubular / RCC pole and cleaning the surface etc. and applying two coats of synthetic enamel paint basedpaint white colour and in bottom black colour including applying two coats of synthetic enamel paint silver colour on bracket of street lights and on clamps,writing the all details complete all as specified and as directed by Engr-in-Charge. Note : 1.5 Sqmm multistranded copper cable drawn in 20 mm non rigid PVC conduit including clamping from fitting to FRP Junction box are deemed to be inclusive in above quoted rate.
35M & L for preparation of old painted surfaces of LT feeder piller box/HT & LT panels by scrapping with wire brush and cleaning etc. and applying two coats of synthetic enamel paint with use of spray gun of approved grey colour and writing the all details as per direction with white colour in back ground complete all as directed by Engr-in-Charge.
36Dismantling unserviceable burnt out Timer by disconnecting the cable and S & F new three phase timer in the existing panel boards with new bolts, nuts, lugs & glands etc of the following capacities complete all as specified and directed. Make: L&T, Legrand, Havells
37S & F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long)complete all as specifed & directed by Engr-in-Charge.
38Supply and laying PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping ofpoles complete all as specified and as directed.
39Supply and laying PCC(1:2:4) type B-2 (using 40mm graded stone aggregate) for foundation of poles complete all as specified and as directed.
40Dismantling unserviceable burnt out MCCB by disconnecting the cable and S & F new MCCB"s in the existing panel boards with new bolts, nuts, lugs & glands etc of capacity MCCB 63 to 100 A fixed type, 4 pole 25 KA, 415 Volts complete all as specited and directed. Make: L&T, Legrand, Havells
41Description all as per Item No 33.00 above but of capacity MCCB 125 /160A fixed type, 4 pole 25 KA, 415 Volts complete all as specified and as directed.
42Description all as per Item No 33.00 above but of capacity MCCB 200 A fixed type , 4 Pole 36 KA, 415 Volts complete all as specified and as directed.
43Taking down old unserviceable point wiring, (light, fan, socket or power) complete including fittings & fixtures such as switch, ceiling rose, pendants, fan regulator, socket, etc., and making good the disturbed surfaceof wall, floors, ceiling etc to match with the existing including touch up of paint/white wash all as specified and directed by Engr-in-Charge.
44M & L for point wiring with 1.5 Sq mm copper conductor multistranded FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC caping and casing/conduit surface type andaccessories of suitable size ISI marked and PVC terminal boxes of 1.6 mm thick of suitable size including fixing/grouting sunken/ surface/ comcealed on wall & roof as per site requirement including provision of modular cover plates for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm multistranded copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for One light/fan point controlled by one, one way switch 5 Amps complete all as specified and as directed.
45Description all as per Item No 35.00 above but One call bell point controlled by one, one way switch 5 Amps complete all as specified and as directed.
46Description all as per Item No 35.00 above but One 3/5 pin 5 Amp socketindependent controlled by one, one way switch 5 Amps complete all as specified and as directed.
47Description all as per Item No 35.00 above but One 3/5 pin 5 amp socketsame board controlled by one, one way switch 5 Amps complete all as specified and as directed.
48M & L for point wiring with 2.5 Sq mm copper conductor multistranded FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC caping and casing/conduit surface type andaccessories of suitable size ISI marked and PVC terminal boxes of 1.6 mm thick of suitable size including fixing/grouting sunken/ surface/ comcealed on wall & roof as per site requirement including provision of modular cover plates for mounting the switches / sockets/ regulators etc including running up of 2.5 Sq mm multistranded copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for One3/5 pin 15 amp socketindependent controlled by one, one way switch 15 Amps complete all as specified and as directed.
49S & F switch piano single pole flush type 5 Amps, 230 volts complete all as specified and directed.
50S & F switch socket combination flush type multipurpose 2/3 pin 5 Amps 2 in 1, 230 Volts complete all as specified and as directed.
51S & F switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 Amps flush type universal complete all as specified and as directed.
52S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc., as required all as specified and as directed.
53S & F Bell push, flush type, 5 Amps completeall as specified and as directed.
54S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed.
55S & F in repairs Bell, Ding Dong AC 230 volts, single pole complete all as specified and as directed.
56S & F Modular switch 1 way 6 A, 1 Module complete all as specified and as directed.
57S & F Modular switch 1 way 16 A, 1 Module complete all as specified and as directed.
58S & F Modular Socket 6A-2/3 pin combined 2 module complete all as specified and as directed.
59S & F Modular Socket 6A/16-2/3 pin combined 2 module complete all as specified and as directed.
60S & F Modular Fan step regulator, 120W-2 Module complete all as specified and as directed.
61M & L for submain wiring withsingle core PVC insulated FRLS multistranded copper conductor cable of size 2 x 4.0 Sqmm drawn into and includingrigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 4.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete all as specified and as directed. Note : (i) 3 Runs of 4 Sqmm cable shall be measured as one unit length. (ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
62M & L for submain wiring withsingle core PVC insulated FRLS multistranded copper conductor cable of size 2 x 6.0 Sqmm drawn into and includingrigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 6.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete all as specified and as directed. Note : (i) 3 Runs of 6 Sqmm cable shall be measured as one unit length. (ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
63S & F in replacement sheet metal enclosure MCBDBSPN4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and as directed.
64S & F in replacement sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and as directed.
65S & F MCB SP 6 to 32 Amps 240V 10 KA."C" Series complete all as specified and as directed.
66S & F MCB SPN upto 32 Amps 240V 10 KA."C" Series complete all as specified and as directed.
67S & F MCB TP upto 32 Amps 415V 10 KA."C" Series complete all as specified and as directed.
68S & F MCB TPN upto 63 Amps 415V 16 KA."C" Series complete all as specified and as directed. Note for Item No 53.00 to 56.00 :- MCBs / MCCBswill have to suite upon with the base of the existing Panel / DB as per site requirement
69S & F ultra bright LED tube rod 18/20 with out put of 1800 lumens(single side connection) with very high efficacy suitable for installation in existing tubelight G13 lamp holders to give glare free light with necessary wiring and removal old existing unsv tube from fitting complete all as specified and as directed. Make :-Bajaj, Philips, Wipro, Havells, Syska, Jaquar
70S & FLEDbulb 9/10Wattcomplete all as specified and as directed. Make : - Bajaj, Philips, Syska
71S & F wall mounted LED 18/20 watts with out put of 1800 lumens , boxtype (decorative) light fitting, 230 volts with extruded aluminiumbody heat sink provided for efficient heat dissipation and intregrated electronic driverconnector block etc complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4" x 18 watts including removal old existing unsv tube light fitting complete all as specified and as directed.
72S & F surface mounting10 Watt LED luminaries with epoxy white powder coated CRCA sheet steel housing with reeded translucent acrylic diffuser and1 x 10 Watt LED fittingincluding taking down old unserviceable fittings any type complete all as specified and as directed . Make : Phillips , Bajaj, Wipro
73Taking out the existing any typefittings on ceilings and S & F 36 Watt LED luminaire suitable for 600 x 600mm modular ceiling grid including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 3600 total lumen. The 36 W system shall be operating at 220-240 volt AC supply having internal driver IP 20, surge protection 2KV, ambient temperature -20 to 45 degree C, frequency 50 to 60 Hz. The system efficacy must be between 80-100 lumen /watt , with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , CRI minimum 80. PF should be greater than0.95 , THD < 10% . Indivisual LED"s should not be visible for glare free output ,colour temperature 6500k all as specified and as directed.
74Taking down the ceiling / Exhaust fans of any model, size & sweep carefully from its original position and dismantlingmotor and over hauling complete by cleaning all dust / grease with kerosene or petrol, & replacement of unserviceable bearings, bushes, split pins and nut and bolts and applying new grease for bearings, reassembling the motor and fixing the blades, preparation old surfaces of fan of any sweep & model and painting the with synthetic enamelled paint by spraying including filling cavities and testing and refixing the same complete as directed by Engr in Charge. Note for Item (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as ""Supply only"" (s) of this schedule. However labour element involved in replacementis included in unit rate quoted against this Item. (ii). Any unforeseen minor repair and minor parts like Rubber bush, MS Clamps, split pins, base frames, nuts, bolts etc are also deemed to be included with unit rate.
75Supply only following spares of ceiling / exhaust fan of any model, size & sweep to incorporate against each Item of Schedule "A"here-in-above Item complete all as specifed & directed (a) Supply only ball bearing suitable for ceiling fan upto 1400 mm sweep complete all as specified and as directed.
76(b) Supply only ball bearing suitable for Exhaust fan upto 450 mm sweep complete all as specified and as directed.
77(c) Supply only GM bush for C/fan and E/fan complete all as specified and as directed.
78M & Lforrewinding the motor of ceiling Fan 1200mm /1400mm Sweep by unscrewing without damaging any parts, rewinding the same with fine quality of super enamelled copper winding wire of suitable size complete including taking out burned unserviceable copper winding wire complete all as specified and as directed.
79M&Lforrewinding the motor of exhaustFan 300/450mm Sweep by unscrewing without damaging any parts, rewinding the same with fine quality of super enamelled copper winding wire of suitable size complete including taking out burned unserviceable copper winding wire complete all as specified and as directed.
80S & F in repairs capacitor 2.5 MFD capacity including removal of unserviceable ones complete all as specified and directed.
81S & F in repairs capacitor 4 MFD capacity including removal of unserviceable ones complete all as specified and directed.
82Maintenance and servicing, overhauling to DG set including attending faults on call basis for normal repairs including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery tereminals, adding distilled water checking the oil, coolent levels of capacity upto 250 KVA DG set installed at various locations complete all as specified and as directed by Engr- in- Charge Note:- (i)Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iii) Proper record & test results of the same shall be maintained as directed (iv)Work shall be carried out at site at different location Details of Plants :- (a)250 KVA DG Set-01 No (b)62.5 KVA DG Set - 01 No
83Servicingand cleaning ofradiator a of DG Sets of capacity from 63 KVA to 250 KVA completeincl taking out properly all as specified and as directed.
84Servicing of self startora of DG Sets of capacity from 63 KVA to 250 KVA complete all as specified and as directed.
85Supply only the following Items of DG Sets of capacity from 63 KVA to 250 KVA to incorporate against each Item ofSchedule "A"here-in-above:(a) Spin-On Lub Oil Filter. Part No 06.436.01.0.00 complete all as specified and as directed.
86(b) Spin-On Filter Assembly. Part No - F6.009.04.0.00 complete all as specified and as directed.
87(c) Fuel Filter Pre. Part No 48.117.04.0.00 complete all as specified and as directed.
88(d) Fuel Filter Micro. Part No 48.117.05.0.00 complete all as specified and as directed.
89(e) Air Filter Safety. Part No - F6.404.28.0.00 complete all as specified and as directed.
90(f) Air Filter Primary. Part No - F6.404.27.0.00 complete all as specified and as directed.
91(g) Spin-On Lub Oil Filter. Part No 04.270.01.0.00 complete all as specified and as directed.
92(h) Fuel Filter Pre. Part No 3H.132.01.0.00 complete all as specified and as directed.
93(j) Fuel Filter Micro. Part No 3H.132.02.0.00 complete all as specified and as directed.
94(k) Air Filter Safety. Part No - 6H.411.02.0.00 complete all as specified and as directed.
95(l) Koel Care Super Oil. Part No - 82.050.10.0.20. & 82.060.10.0.13 complete all as specified and as directed.
96(m) Koel Care Coolant Premix. Part No - 82.020.35.1.05 complete all as specified and as directed.
97S & F for SPN enclosure with two pin and earth plug and socket with 240 volts 20 Amp SPNMCB including removal old unsv one complete all as specified and as directed.
98M & L for taking out & servicing Split type air conditioner in citu (Split type air conditioner comprises wiith out door and indoor unit complete) of capacity 1.5/ 2.0 TR of any make and any type by replacing unserviceable parts from the machine including charging of Refrigerant gas after vacuuming and leak testing. Brazing the suction/ discharge tubes where required and cleaning of cooling coil and condenser coil, oiling, greasing of blower motor, checking of electrical circuitand replacement of defective electric blower fan motor,over load protector,relay, capacitor etc to achive proper cooling effect and also checking of electronic circuit of machine and repair where necessory by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing commissioning & refixing in same or new location complete all as specified and directed. Note:-i) Compressor and major spare parts where everis required shall be measured and paid separately under respective item. ii) During vacuming the machine existing Refrigerant shall be collected in cylinder and the same shall be reused while charging after carry out of repair and additional qty required for smooth functioning shall be measured and paid separately under respective item.
99Supply only electric blower fan motor of split AC 230 volt 1340 RPM single shaft with ball bearing for any make split AC 1.5 Ton capacity complete all as specified and directed.
100Supply only running capacitor upto 50 (+,- 6) MFD and complete all as specified and directed.
101Supply only starting capacitor 100/120 MFD complete and complete all as specified and directed.
102S & F for indoor unit Condenser coil of split type air conditioner 1.5 ton capacity wall mounted operationandperforming on cooling systemof make as persite requirement including removal of old existing unsv one complete all as specified and directed.
103Taking down existing unserviceable outdoor Condenser coil unit and supply and fix new outdoor Condenser coilunit for 1.5 TR capacity Split AC workingwith compressor of make as per site requirement complete all as specified and directed.
104S & F for flexible PVC/hose pipe 20 mm dia heavy duty from outdoor unitincluding removal of old existing unsv one complete all as specified and directed.
105M & L for filling up & charging of R - 22, 32, 410a etc refrigerant or type of gas as per site requirementfor window/spilt type air conditioner of capacity 1.5TR, refrigerator and water cooler of capacity 80/40 litres after leak testing of complete system and making good by bracing complete all as specified and directed.
106S & FAC copper pipe12.7 mm dia including removal of old existing unsv one complete all as specified and directed.
107S & FAC copper pipe6.35 mm dia including removal of old existing unsv one complete all as specified and directed.
108S & F for PCB (Printed circuit board) of indoor unit suitable for existing 1.5ton capacitysplit AC including removal of old existing unsv one complete all as specified and directed.
109Removing the old unserviceable sealed compressor unit from split AC ofany make, capacity 1.5 TR and supply and fixing new hermetically sealedcompressor of same make as that of the existing for split AC ofcapacity 1.5 TR with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed.
110S & F XLPE, insulated, armoured, heavy duty, electric cable size 16 Sqmm 2 core with stranded aluminium conductors, 1100 volts grade, laid in tranches/fixing on wall/poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, including taking down existing unserviceable cable with GI protections pipes, complete all as specified and as directed.
111S & FLED 100 W Flood Light, IP-65 Outdoor Light, Cool White with BIS approved driver, heat management with aluminum heat sink, with protections available -short circuit, open circuit, under voltage, over voltage, isolution, 6kv - internal surge protection complete all as specified and as directed. Make : - Philips / Bajaj / Wipro/ Luker
112M & L for preperation of old painted surfaces of two pole RCC structural and transformer and cleaning the surface etc. and applying two coats of synthetic enamel paint basedpaint white colour and in bottom black colour including applying two coats of synthetic enamel paint silver colour on bracket of street lights and on clamps,writing the all details as per direction complete all as specified and as directed.
113Dismantling unserviceable burnt out MCCB by disconnecting the cable and S & F new MCCB"s in the existing panel boards with new bolts, nuts, lugs & glands etc of capacity MCCB 40 to 100 A fixed type, 4 pole 16 KA, 415 Volts complete all as specited and directed. Make: L&T, Legrand, Havells