Tender For Repair / Maintenance Of Internal Electrical Services, Repair/ Maintenance Of External Electric And Water Supply At Tech Area At Likabali Mil Stn Under Ge 872 Ews, likabali-Assam

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Internal Electrical Services, Repair/ Maintenance Of External Electric And Water Supply At Tech Area At Likabali Mil Stn Under Ge 872 Ews. Submission Date for this Tender is 29-05-2024. Electrical Maintenance Tenders in likabali Assam. Bidders can get complete Tender details and download the document.




Tender Notice

43330814
Tender For Repair / Maintenance Of Internal Electrical Services, Repair/ Maintenance Of External Electric And Water Supply At Tech Area At Likabali Mil Stn Under Ge 872 Ews
Open Tender
Indian
Assam
likabali
29-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair / Maintenance Of Internal Electrical Services, Repair/ Maintenance Of External Electric And Water Supply At Tech Area At Likabali Mil Stn Under Ge 872 Ews

Key Value

Document Fees
INR 500 /-
EMD
INR 28760.0 /-
Tender Value
INR 14.38 Lakhs /-

Attachment

FileName File Description File Size
bd22a510-a0b9-4ad1-9406-4aeaf697ea75.html Tender Notice 0 KB
BOQ_730784.xls Tender Document 0 KB
Tender8602.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: REPAIR / MAINT OF INTERNAL ELECTRICAL SERVICES; REPAIR/ MAINT OF EXTERNAL ELECTRIC AND WATER SUPPLY AT TECH AREA AT LIKABALI MIL STN UNDER GE 872 EWS
Sl. No. Item Description
1Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc (except light fitting). removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
2Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified anddirected.
3Taking down unserviceable sub-main wiring (any numbers of cable) withrigid PVC/steelconduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
4M & L for Point wiring for one light/exhaust fan/fan point/call bellcontrolled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductorcable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.)
5All as per item No. 04 above but forOne 3/5 pin socket outlet 6 amps on independent board complete ditto
6All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps pointon same boardcomplete ditto
7All as per item No. 04 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistrandedFRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cableFRLS (ISI marked) as earth lead complete ditto
8S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
9S & F in repairs switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
10S & F Switch socket combination 2 in 1, 5 pin, 6 Amps,flush type, 240 volts complete all as specified and directed.
11S & F in repairs Switch socket combination 2 in 1, 5 pin, 6 Amps,flush type, 240 volts complete all as specified and directed.
12S & F Socket outlet 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed.
13S & F in repair Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed.
14S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed.
15S & F in repairs Switch socket combination 2 in1, 3 pin, 6 and 16 Amp, flush type, universal complete all as specified and as directed.
16S & F bell push flush type, 6 amp 240 volts, complete all as specified and as directed.
17S & F in repairs bell push flush type, 6 amp 240 volts, complete all as specified and as directed.
18S & F Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
19S & F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
20S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
21S & F in repairs ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
22S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed.
23S & F in repairs Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed.
24S & F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
25S & F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
26M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casing capping of suitable size with all accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed. (Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of casin cappingshall be measured as one length)
27M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casing capping of suitable size with all accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed. (Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of casing cappingshall be measured as one length)
28M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casin capping of suitable size with all accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of casin cappingshall be measured as one length)
29S & F in repair Rigid non-metalic PVC casing capping of size 32mm inclusive of all fittings and fixing accessoriescomplete all as specified and directed.
30S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
31S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed.
32S & F in repairs LED Bulk Head, 10 Watt, IP 65 rated, with pressure die cast aluminium housing and acrylic diffuser, CCT: WW/NW/CW, CRI > 80 Ra, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specifiedand directed. (Make: Jaquar Cat No. LBLK02X010XC or equivelant of make as per list of manufacturer)
33S & F in repairs LED tube light fittings, batten type, poly carbonate body, 20 Watt, Lumen = 2000, Luminous afficacy = 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD = 20% & PF =0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. (Make: Jaquar Cat No. LKBP4KV020XC or equivelant of make as per list of manufacturer)
34S & F in repairs LED Bulb, 12 Watts, B-22 Lumen = 1200, Luminous afficacy = 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specifiedand directed.
35S & F in repairs LED tube light fittings, batten type, poly carbonate body, 10 Watt, Lumen = 1000, Luminous afficacy = 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD = 20% & PF =0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. (Make: Jaquar Cat No. LKBP4KV010XC or equivelant of make as per list of manufacturer)
36S & F in repairs LED light fittings, ceiling mounted, panel type, white powder coated CRCA body, PC lens, Approx dimensions 2"x2", 36 Watt, Lumen = 3600, Luminous afficacy = 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,minIP 40 rated, THD = 20% & PF =0.9, over voltage protection withstand upto 360 (for 10 Minutes), 4KV surge Protection with open and short circuit protections as per IS: 10322with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specifiedand directed. (Make: Jaquar Cat No. LULTSLS036XC or equivelant of make as per list of manufacturer)
37S & F in repairs LED Driver 24 to 36/40 watts as per site requirement complete all as specified and as directed.
38S & F in repair LED 70 Watt flood light luminaire, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium, IP66, suitable for highlighting architectural facade and general purpose lighting with lamp and all accessories including mounting clamps, bolts, nuts and washers and copper conductor cable of suitable size to fittings of suitable length fixed as in High mast light at any height complete all as specified and as directed. (Make: Havell"s Cat No. JETAALBAFLOODLIGHT70W or equivelant of make as per list of manufacturer)
39S & F in repair LED 100 Watt flood light luminaire, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium, IP66, suitable for highlighting architectural facade and general purpose lighting with lamp and all accessories including mounting clamps, bolts, nuts and washers and copper conductor cable of suitable size to fittings of suitable length fixed as in High mast light at any height complete all as specified and as directed. (Make: Havell"s Cat No. JETAALBAFLOODLIGHT100W or equivelant of make as per list of manufacturer)
40S & F in repair LED 120 Watt flood light luminaire, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium, IP66, suitable for highlighting architectural facade and general purpose lighting with lamp and all accessories including mounting clamps, bolts, nuts and washers and copper conductor cable of suitable size to fittings of suitable length fixed as in High mast light at any height complete all as specified and as directed. (Make: Havell"s Cat No. JETAIRISFL120WLED757APWBLTG or equivelant of make as per list of manufacturer)
41S & F in repair LED 120 Watt Higbay luminaire, Next generation, energy saving, environment friendly & robust highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy upto 150 lm/W with lamp and all accessories including mounting clamps, bolts, nuts and washers and copper conductor cable of suitable size to fittings of suitable length fixed as in High mast light at any height complete all as specified and as directed. (Make: Havell"s Cat No. SAUCERGENXHBP120WLED757P90DBOLTG or equivelant of make as per list of manufacturer)
42S & F in repairs Concealed sheet metal enclosurewith socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed.
43S & F Distribution Board, SPN 4 Way, 240V, Double door with IP 43 protection complete all as specified and as directed. (Make: Havell"s cat part No. DHDNSHODAW04 or equivalent make as per List of Manufacturer"s)
44S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havell"s cat part No. DHDPSHODRW08 or equivalent make as per List of Manufacturer"s)
45S & F Distribution Board, TPN 4 Way, 415V, Double door with IP 43protection, IK 09 complete all as specified and as directed. (Make: Havell"s cat part No. DHDNTHCDRW04 or equivalent make as per List of Manufacturer"s)
46S & F MCB SP 40 Amps, 240 Volts, 10KA, B Curve,complete all as specified and as directed (Make: Havell"s cat part No. DHMGBSPF040 or equivalent make as per List of Manufacturer"s)
47S & F in repair MCB SP 40 Amps, 240 Volts, 10KA, B Curve,complete all as specified and as directed (Make: Havell"s cat part No. DHMGBSPF040 or equivalent make as per List of Manufacturer"s)
48S & F MCB SPN 6-32A Amps, 240 Volts,10KA, C Curve complete all as specified and as directed Havell"s cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer"s)
49S & F in repair MCB SPN 6-32A Amps, 240 Volts,10KA, C Curve complete all as specified and as directed Havell"s cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer"s)
50S & F MCB, TPN 6-32 Amps, 415 Volts, 10KA,C Curve complete all as specified and as directed (Make : Havell"s Cat part No. DHMGCTNF006-032or equivelant of make as perList of manufacturer"s)
51S & F in repair MCB, TPN 6-32 Amps, 415 Volts, 10KA,C Curve complete all as specified and as directed (Make : Havell"s Cat part No. DHMGCTNF006-032or equivelant of make as perList of manufacturer"s)
52S & F 1100 volts grade, heavy duty cablePVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathedin service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular 6 Sqmm solid conductor including taking down existing one complete all as specified and directed.
53S & F 1100 volts grade, heavy duty cablePVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathedin service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable slat or circular 10 Sqmm solid conductor including taking down existing one complete all as specified and directed.
54M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia TMT bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
55Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
56Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
57Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting pointcomplete all as specified and directed.
58Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work shall be measured paid seperately)
59All as per Serial item No. 58 above but 70 Sqmm 3.5 Core cable complete ditto
60All as per Serial item No. 58 above but 95 Sqmm 3.5 Core cable complete ditto
61All as per Serial item No. 58 above but 185 Sqmm 3.5 Core cable complete ditto
62M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
63Supply and laying locally available best quality, well burnt sub class B bricks (old size), laid dry in trenches for protection of UG cables complete all as specified and directed.
64M & L for boring of horizontally holes by manual method under road and dia of hole not exc 100mm without damaging the exsting road, getting out and disposal of excavated soil, etc to a distance not exc. 50 meter from the site of work complete all as directed by Engineer in charge.
65S & F in repair for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
66S & F in repair for 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
67S & F in repair for 80 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
68S & F in repairon load Change over switch, general purpose with side handle, current rating 63Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. (Make: L & T Cat No. CO10630OOOO or equivelant approved make as per list of manufacturer)
69S & F in repairon load Change over switch, general purpose with side handle, current rating 100Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. (Make: L & T Cat No. CO11000OOOO or equivelant approved make as per list of manufacturer)
70S & F in repairon load Change over switch, general purpose with side handle, current rating 200Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. (Make: L & T Cat No. CO22000OOOA or equivelant approved make as per list of manufacturer)
71S & F in repair MCCB 415 Volt 16 KA, 4 Pole,63 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 13 or equivelant of make as per List of Manufacturer"s)
72S & F in repair MCCB 415 Volt 16 KA, 4 Pole,100 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 15 or equivelant of make as per List of Manufacturer"s)
73S & F in repairs MCCB 415 Volt 16 KA, 4 Pole,125 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 16 or equivelant of make as per List of Manufacturer"s)
74Supply, Install, Commissioning and testing LT cubical type panel board, CPRI approved factory made, outdoor type, suitable for 415 Volts, 3 Phase, 4 Wire system, 50 Hz supply having aluminium bus bar, 400 Amps for phases and neutral install on porcelain/ epoxy insulators, made out of 3.15mm thick CRCA sheet, Dust and vermin proof, weather proof (IP54), powder coated with front and rear openable door shutter with seperate hinge door with locking arragnement, totally enclosed type including PCC 1:2:4, Type B-1 foundation of suitable size, and internal wiring with copper conductor cable complete including taking down/dismantling existing panel board all as specified and directed comprising with the following items: (A) Incomming: (i) MCCB 500 Amps, 4 pole, 36 KA, 415 Volts, Thermal magnetic release:- 01 No (B) Outgoing : (i) MCCB, 4 pole, 250 Amp, 36 KA, 415 Volts, Thermal magnetic release:- 02 Nos (ii) MCCB, 4 pole, 200 Amp, 36 KA, 415 Volts, Thermal magnetic release:- 01 No (iii) MCCB, 3 pole, 160 Amp, 36 KA, 415 Volts, Thermal magnetic release:- 01 No (iv) Digital multifunction meter with 3 Nos CTs of 20/5A - 01 Set (v) Bus bar 4 strips aluminium of capacity 400 Amps, TPN of suitable size - 01 Set (vi) Phase indicator for (RYB) - 01 sets of three (Note: (i) Panel shall be of factory made and CPRI approved (ii) External terminals with tinned copper has to be provided for trimming the incoming and outgoing cables with suitable lugs of MCCB/MCB (if required) (iii) Necessary excavation and earth work for foundation shall deemed to be included in the unit quoted rate)
75Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
76Taking up or down 25 or 32 mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
77Taking up or down 40 or 50mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
78Supply, laying, connection and testing, 50mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
79Supply, laying, connection and testing, 40mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
80Supply, laying, connection and testing, 32mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
81Supply, laying, connection and testing, 25mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
82Supply, laying, connection and testing, 20mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
83S & F in repair 20 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the sitecomplete all as specified and directed.
84S & F in repair 25 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the sitecomplete all as specified and directed.
85S & F in repair 32 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the sitecomplete all as specified and directed.
86S & F in repair 40 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the sitecomplete all as specified and directed.
87S & F in repair 50 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the sitecomplete all as specified and directed.
88M & L for construction of brick masonry valve pit of size 60 cm x 60 cm x 60 cm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made out of 3.15mm thick MS sheet duly welded with provision of hinges, handle and locking arrangement including 40 x 40 x 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, applying two coats of anti-corrosive paint over a coat of red oxide, zinc chrome primer after preparation of steel & iron surfaces including necessary excavation &earth work in soft/loose soil and demolition of existing one complete as specified and directed all as per relevant TD drawing. (Note : Drawing not attached with the tender document.However, the same can be seen in GE/AGE E/M office during working hours)
89Supply only High strength calcium Hypo Chloride, 65-70% chlorine content, Calcium based granular disinfectant for water treatment chemical complete all as specified and directed. (Note: Make shall be as per approved makes of E-in-C. Testiting certifcate of chemical shall be submitted by the contractor before supply).