Tender For Repair/Maintenance To Internal Wiring, Fitting/Fixtures In Arty Bde, Fd Regt, Engr Regt, Sata And Stn Hq At Dipatoli Mil Stn., dipatoli-Jharkhand

Military Engineer Services-MES has published Tender For Repair/Maintenance To Internal Wiring, Fitting/Fixtures In Arty Bde, Fd Regt, Engr Regt, Sata And Stn Hq At Dipatoli Mil Stn.. Submission Date for this Tender is 29-05-2024. Electrification Work Tenders in dipatoli Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

43330731
Tender For Repair/Maintenance To Internal Wiring, Fitting/Fixtures In Arty Bde, Fd Regt, Engr Regt, Sata And Stn Hq At Dipatoli Mil Stn.
Open Tender
Indian
Jharkhand
dipatoli
29-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair/Maintenance To Internal Wiring, Fitting/Fixtures In Arty Bde, Fd Regt, Engr Regt, Sata And Stn Hq At Dipatoli Mil Stn.

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
4bf6a42a-5e2e-4d87-832d-2862465c4747.html Tender Notice 0 KB
1988tenderdocuments.pdf Tender Document 0 KB
BOQ_730233.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work :REPAIR/MAINT TO INTERNAL WIRING, FITTING/FIXTURES IN ARTY BDE, FD REGT, ENGR REGT, SATA AND STN HQ AT DIPATOLI MIL STN.
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc, complete all as specified and directed.
2Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good thedisturbed surfaces of walls,floors roofs etc complete all as specified and directed.
3Taking down old/unserviceable TPN/SPN DBs MCB DBs of any capacity by disconnection of electric connectionincluding MCCB, MCBs ,Isolators,etc and making good to disturbed surface complete all as specified and directed.
4M&L point wiringfor One light/Fan point controlled by onefive amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn throughPVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screwas suitablesize for mounting ofswitch & scoketincluding 1.5 sqmm size pvc insulated unsheathed copperconductor to common earth and connecting to earth dolly complete all as specified and directed. Note: Therate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing ofswitch and scoket including cutting chases in wallmaking good to disturbed surface and matching with existing surfaces.
5All as per Ser item No 4 here-in-before but one 3 Pin Socket out let 5 Amps on the same board, complete all as specified and directed.
6All as per Ser item No 4 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board, complete all as specified and directed.
7All as per Ser item No 4 here-in-before but one bell/buzzer point controlled by onepush button on the independent board, complete all as specified and directed.
8All as per Ser item No.4 here - in - before but one lightpoint controlled by two 2 - way switches,with wire 1.5 Sqmm size, complete all as specified and directed.
9All as per Ser item No 4 here-in-before butpoint wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly, complete all as specified and directed.
10M&L point wiringfor One light/Fan point controlled by onefive amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn throughPVCCasing caping 20/25 mmon wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screwas suitablesize for mounting ofswitch & scoketincluding 1.5 sqmm size pvc insulated unsheathed copperconductor to common earth and connecting to earth dolly complete all as specified and directed.Note: Therate quoted is deemed to be included for Phenolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing ofswitch and scoket including cutting chases in wallmaking good to disturbed surface and matching with existing surfaces.
11All as per Ser item No 10 here-in-before but one 3 Pin Socket out let 5 Amps on the same board, complete all as specified and directed.
12All as per Ser item No 10 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board, complete all as specified and directed.
13All as per Ser item No 10 here-in-before but one bell/buzzer point controlled by onepush button on the independent board, complete all as specified and directed.
14All as per Ser item No.10 here - in - before but one lightpoint controlled by two 2 - way switches,with wire 1.5 Sqmm size, complete all as specified and directed.
15All as per Ser item No 10 here-in-before butpoint wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly, complete all as specified and directed.
16S&FSwitch Piano type2 way switch 5 amp230 vcomplete all as specified and directed .
17Supply and fixSwitch Piano type, single pole, one way 5 Amp complete all as specified & directed.
18S&F Switch pianotype , singlepole , one way 15 Amps complete all as specified and directed.
19S&FSocket out let2-in-1 2/3 pin 5 Ampscomplete all as specified and directed.
20S&F Socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified & directed.
21S&F in replacement electric Bell, ding dong type AC 230 Volt single pole complete all as specified & directed .
22S&Fin replacement Bell push 5 Amps for electric Bell/Buzzer, AC 230 Volt single pole complete all as specified & directed.
23S&FCeiling rose,3 terminal PVC/polycarbonatecomplete all as specified and directed.
24S&Felectronic regulator step type230 Volts single phase120 wattcomplete all as specified and directed .
25M&L for lamp holder , PVC /Polycarbonate type with back plate suitabl for batten fittings complete all as specified and directed .
26Supply and Fix modular switch one way 6 Amp 240 volts one module complete all as specified and directed .
27S&F Modular Sheet Cover of size 8"X10" comple all as specified and directed.
28S&F Modular Sheet Cover of size 6"X8" comple all as specified and directed.
29Supply and Fix modular switch two way 6 Amp 240 volts one module complete all as specified and directed .
30Supply and Fix modular bell push switch one way 5 Amp 240 volts one module complete all as specified and directed .
31Supply and Fix modular switch one way 16 Amp 240 volts one module complete all as specified and directed .
32Supply and Fix socket modular one way 6 amp 240 volts two module complete all as specified and directed .
33Supply and Fix socket modular one way 16 amp 240 volts two module complete all as specified and directed .
34Supply & Fix TV socket modular one module complete all as specified anddirected .
35Supply & Fix Telephone socket modular one module complete all as specified anddirected .
36Supply & Fix regulator modular step type one way 220 volttwo modulecomplete all as specified and directed .
37Supply and fix in replacement of modular USB Charger complete all as specified and directed .
38Supply and fix in replacementBlanking Plates for covering of MCB DB open space complete all as specified and directed .
39Supply and fix in replacementswitch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type as per existing model and size complete all as specified and directed .
40Supply and fix in replacement switch socket combination 2 in 1 3 pin 5 Amps flush type as per existing model and size complete all as specified and directed.
41S&F in replacement ofsheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 Amps to 32 Amps complete all as specified anddirected .
42M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm diaas per site requirement along walls/ceilingetc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surfaceconduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor)be measured as one length)
43All as per ser item No-42 here-in-beforebut 2X2.5 Sqmm and 1X 2.5 Sqmm for Earth wire, complete all as specified and directed.
44All as per ser item No-42 here-in-beforebut 2X4 Sqmm and 1X 4.0 Sqmm for Earth wire, complete all as specified and directed.
45All as per ser item No-42 here-in-beforebut 2X 6 Sqmm and 1X 6.0 Sqmm for Earth wire, complete all as specified and directed.
46M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor FR PVC insulated and unsheathed FRLSH cable 1100 Volts grade, drawn in with and including PVC casing / caping 20/25 mm diaas per site requirement along walls/ceilingetc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire (Phase red colour, neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surfaceconduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor)be measured as one length)
47All as per ser item No-46 here-in-beforebut 2X2.5 Sqmm and 1X 2.5 Sqmm for Earth wire, complete all as specified and directed.
48All as per ser item No-46 here-in-beforebut 2X4 Sqmm and 1X 4.0 Sqmm for Earth wire, complete all as specified and directed.
49All as per ser item No-46 here-in-beforebut 2X 6 Sqmm and 1X 6.0 Sqmm for Earth wire, complete all as specified and directed.
50M&L fixingPVCCasing caping 20/25 mmon wall/ceiling ,including replacement of old u/s PVCcashing caping, clip, nailsfor exesting old servicablepoint wiringfor existing old servicable point wiring of 1.5mm,/2.5mm,/4mm & 6 sqmm , Existing wiring/Submain wiring drawn through new PVCCasing caping/conduit on wall/ceiling ,including replacement . (Note:- Therate quoted is deemed to be included for taking down of U/S PVC Casing caping/ conduitincluding cutting &fixing charges &making good to disturbed surface and matching with existing surfaces.)
51Supply and fixMCBDB SPN 4 way double door withmetal door suitable forhousing of MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed .
52Supply and fixMCBDB SPN 8 way double door with metal door suitable forhousing of MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed .
53Supply and fix MCBDB SPN 12 way double doorwith metal door suitabl forhousing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directedcompleteall as specified and directed .
54Supply and fix MCBDB TPN 4 way with metal door suitable forProvision ofincommer and out going MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
55Supply and fix MCCBDB TPN 4 way with metal door suitable forProvision ofincommer as MCCB and out going MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
56Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed .
57Supply and fix in replacement MCCB 63 Amp 415 volts 16kA 4 pole complete all as specified and directed .
58S&F in replacement ofMCB SP (6 to 32) Amps 240 V "C" curve complete all as specified and directed.
59S&F in replacement of MCB SPN (40 to 63)Amps "C" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
60S&F in replacement ofisolator DP 40 Amps "C" Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
61S&F in replacement ofisolator DP 63 Amps "C" Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
62S&F in replacement ofisolator TPN 40 Amps "C" Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
63S&F in replacement ofisolator TPN 63 Amps "C" Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
64S&F in replacement ofisolator TPN 100 Amps "C" Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
65S&F in replacement of LEDtube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with polycarbonate housing & integrated electronic driver , including all internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed .
66S&F in replacement of Lienear & compact9 wat LED mirror light with decorative grey end caps,polycarbonate body and ribbed opal diffuser including 2/3 core flexible copperwire with flexible pipe ceiling rose to light fittings complete all as specified and directed .
67S&F in replacement of LEDtube light fitting 18 watt 230 Volt decorative ultra slim linear LED Lighting with polycarbonate housing & integrated electronic driver , including all internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed .
68S&F LED warm tube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with polycarbonate housing & integrated electronic driver , including all internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed .
69S&FLEDporch light fitting 12 watt 230 Volt decorative ultra slim linear LED Lighting with polycarbonate housing & integrated electronic driver , including all internally pre-wired complete all as specified and directed .
70S&F in replacement of environmental friendly, ultra modern, energy saving, surface mounted, decorative oval plastic bulk head LED light fittings 10 watt capacity, comprising of high brightness LEDs, IP54 protection complete with all accessories internally pre-wired and inncluding connecting upwith 2/3 core twisted flexible copper conductor cable with suitable sizeofflexible PVC/steel Conduit complete all as specified and directed.
71S&F in replacement of Ultra slim LED panel tube light fitting 24watt 230 Volt made from extruded aluminium housing frame (recesss/pendant) 1"x1" Complete with all accessories internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed .
72Supply and fix in replacement "JUNO" integralpost top lantern 45 watt copper dust painted cast aluminium spigot, spun aluminium canopy with clear acrylic cover with LED lights including all accessories such as Bracket, GI Pipe and prewired complete all as specified and directed.
73S&F in replacement of building LED security light fitting 25 Watt in aluminium pressure die cast aluminium housing with high power led as lighitning sourse and lens embedded pc cover having IP 65 protection and impact resistance of IK07 with 10 KV built in super protection device. Luminaire with high power LED as light source including suitable size of GI bracket fixed with 2 nos GI clamp nut , bolt , washer etc complete all as specified and directed
74S&F in replacement of Ultra slim LED panel tube light fitting 36watt 230 Volt made from extruded aluminium housing frame (recesss/pendant) 2" x2" Complete with all accessories internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed .
75S&F in replacement ventilating air fan single phase steel body 300 mm sweep, 230 voltcomplete with louver shutter and including makingof hole suitablesizefan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed.
76S&F in replacementof ventilating airfan single phase made of sturdy engineering plastic 300 mm sweepcomplete with louver shutter and including makingof hole suitablesizefan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed.
77S&F Electronic meters temper proof LCD display with polycarbonate cover 230 V , 10-60 Amp, accuracy class- I 50 Hz, conforming to IS 1379, IP- 54 with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed.
78Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductorcable all as directed.
79Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 10 sqmm 2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductorcable all as directed.
80Excavation intrenches in loose/soft soil not exceeding 1.5 metrewide and not exceeding 1.5 metredeep for laying of cables,poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete, all as specified.
81Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
82Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
83Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed.Note : Punned down thickness shall be considered for measurement , complete all as specified and directed.
84Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed.
85M &L Earthing complete with galvanised steel earth plate electrode 60cm ×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed. Note :- i) Earthing test must be carried out in presence of Engr-in-Charge. ii) The earthing resultnot more than 2 Ohms or disered earth resistance value. iii) Meggerrequired for testingwill bebe provided . by the contractor. iv) Contractor shall submit earth resistance testing report before submission of bill.
86S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail