Tender For Additional / Alternator To Existing Sewage Line Septic Tank Storm Water Drainage Of Hq Ce 31 Zone And Stn Engr Offers Mess Provision Of Defi Geyser In Certain Md Accommodation Provision Of Acs In Jcr 31 Sub Area Sig Coy Drishtikon Drona Ops Roo, Srinagar-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Additional / Alternator To Existing Sewage Line Septic Tank Storm Water Drainage Of Hq Ce 31 Zone And Stn Engr Offers Mess Provision Of Defi Geyser In Certain Md Accommodation Provision Of Acs In Jcr 31 Sub Area Sig Coy Drishtikon Drona Ops Roo. Submission Date for this Tender is 29-05-2024. Geyser Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43328621
Tender For Additional / Alternator To Existing Sewage Line Septic Tank Storm Water Drainage Of Hq Ce 31 Zone And Stn Engr Offers Mess Provision Of Defi Geyser In Certain Md Accommodation Provision Of Acs In Jcr 31 Sub Area Sig Coy Drishtikon Drona Ops Roo
Open Tender
Indian
Jammu And Kashmir
Srinagar
29-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Additional / Alternator To Existing Sewage Line Septic Tank Storm Water Drainage Of Hq Ce 31 Zone And Stn Engr Offers Mess Provision Of Defi Geyser In Certain Md Accommodation Provision Of Acs In Jcr 31 Sub Area Sig Coy Drishtikon Drona Ops Room And Alleid Area At Bb Cantt

Key Value

Document Fees
INR 500 /-
EMD
INR 86700.0 /-
Tender Value
INR 43.35 Lakhs /-

Attachment

FileName File Description File Size
624e2de0-7ecf-4fcf-8c62-78e763a9de20.html Tender Notice 0 KB
BOQ_730814.xls Tender Document 0 KB
Tender31.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: ADDN/ALTN TO EXISTING SEWAGE LINE, SEPTIC TANK & STORM WATER DRAINAGE OF HQ CE 31 ZONE AND STN ENGR OFFR"S MESS, PROVN OF DEFI GEYSER IN CERTAIN MD ACCN, PROVN OF ACs IN JCR, 31 SUB AREA SIG COY, DRISHTIKON, DRONA OPS ROOM AND ALLEID AREA AT BB CANTT, SRINAGAR.
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all specified and directed.
2Demolition of plain cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all specified and directed.
3Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
4M&L for chequered cement concrete tiles with grey cement and pigments 30cmx30cmx22-25mm thick, set, jointed and pointed in neat cement slurry in floorslaid over and including15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed.
5M&L for 25mm thick PCC 1:2:4 type B-1 (using 12.5mm graded crushed stone aggregate) as in sub base/levelling course complete all specified and directed.
6M&L for 75mm thick PCC (1:4:8), Type D-2 (using 40mm graded crushed stone aggregates) as in sub base of floors etc. complete all as specified and as directed.
7M&L for PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs and the like including weathering slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
8Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m complete all as specified and directed.
9Excavation in trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth for foundation, shafts, cesspits, manholes, pier holes etc. not exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and as directed.
10Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and as directed.
11Removing of excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.50 mtr above the starting point, complete all as specified and directed.
12Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed.
13Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all specified and directed.
14Taking down cement plaster of any description, on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as directed.
15Demolition and breaking up drain pipe 150mm dia (salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
16M&L for precast RCC (nominal mix)1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, set in CM 1:4, including necessary formwork complete all as specified and directed.
17M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all specified and directed.
18M&L for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways, railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed.
19M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
20S&F PVC Septic tank suitable for 35 users, having three chambers design and processing the waste through anaerobic process, including excavation of pit of size 3.50mx1.70mx1.80m, level the bed with 250mm thick sand cushioning and fill the side all around the tank with dry sand and compacted and making connection of inlet & outlet to septic tank complete all as specified and directed.
21M&L for brickwork with old size sub class "B" bricks straight or curved on plan exc 6m mean radius and built in CM 1:6 complete all as specified and directed.
22M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
23M&L for PCC (1:3:6), type C-2 (using 40mm graded crushed stone aggregates) as in foundations, filling and mass concrete, complete all as specified and as directed.
24M&L for PCC (1:3:6), type C-1 (using 20mm graded crushed stone aggregates) as in surface channels and drains including necessary form work, complete all as specified and as directed.
25S&F 150mm bore Reinforced concrete pipes, class NP-2, laid and jointed with collars in trenches complete all as specified and directed.
26S&F 200mm bore Reinforced concrete pipes, class NP-2, laid and jointed with collars in trenches complete all as specified and directed.
27M&L for concrete bed to drain pipes of 150mm bore in PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregate, including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
28M&L for concrete bed to drain pipes of 200mm bore in PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregate, including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
29M&L for walling of random rubble, uncoursed,well bonded, bedded and solidaly hearted, built in CM 1:6 etc complete all as specified.
30All as per item No. 29 above but except stone complete all as specified.Note: Old stone obtained from demolition shall be reused.
31M&L for Pre-cast cement concrete block masonry with solid blocks, of PCC 1:3:6, type C-1, using 20mm graded crushed stone aggregate exc. 10cm in width and setting in CM 1:6 complete all as specified.
32M&L for RCC (nominal mix)1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, manhole covers and in shelves and the like including use and waste formwork complete all as specified and directed.
33S&F 450mm bore Reinforced concrete pipes, class NP-2, laid and jointed with collars in trenches complete all as specified and directed.
34S&F electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2KW, capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, PVC connection and fixed to wall with MS fastner, nut, bolts and making electricconnection complete all as specified and directed.
35S&F electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2KW, capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, PVC connection and fixed to wall with MS fastner, nut, bolts and making electricconnection complete all as specified and directed.
36M&L for sub main wiring system with two runs PVC insulated FRLS wire, 1100 volt grade with multistranded copper conductor wire of size2x2.5Sqmm and one run of 1x2.5Sqmm (Nominal area) (ISI Marked) as in earth wire any type any length drawn through in heavy dutyISI markedPVC Casing capping / PVC conduit of suitable size along with its all fittingsand connected accessories and duly fixed concealed on wall or surface on wall and making electrical connection complete all as specified and as directed.Note:- 3 runs of 2.5sqmm wire and one run of PVC cassing capping/conduit shall be measured and 1.0 RM.
37S&F sheet metal enclosure duly powder coated with single pole and neutral enclosure with having a two pin and earth plug & top and mounting channel with one MCB SP 20 Amp and making all necessary electrical connection and dully fixed surface on wall or concealed in wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surfacecomplete all as specified and as directed.
38S&F 15mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
39S&F 15mm bore Bib taps, chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule etc complete all as specified and directed.
40M&L for cutting existing steel tubing 15mm to 40mm bore of pipe in any position and making threaded/screwing in existing steel tubing including inserting required fittings such as GI nipple/tee/ elbow/bend/valve etc for alignment and fixing of inlet cold & outlet hot pipe line system complete all as specified and directed.
41S&F 15mm bore steel water tubing medium grade galvanised with all fitting and fixing accessories as per site requirement and fixed pipe concealed in wall & roof/ surface on wall with providing MS hooks/clamp and connected accessoris, making hole in wall if required and making good distrubed surface as per existing complete all specified and directed.
42Supply, fixing, commissioning and testing of 3 star rated wall mounted split AC, dual invertor based with cooling and heating function and digital inverter type complete set of hi wall split type indoor and outdoor complete set of air conditioner unit with cardless remote control and full filling of initial refrigent gas alongwith having inbuilt heating and cooling arrangement and digital inverter twin rotary type compressor suitable for AC of rating capacity 2.0 TR and suitable for operation of 230Volt 50Hz single phase electric supply including provn of MS stand & bracket for fixing of outdoor and indoor unit system and also providing of both type /size sunction and discharge coper refrigerant piping attachment system of any length and duly both connected it from outdoor unit to indoor unit system alongwith duly overlapped it by nitrile insulation, with insulation taping work and suitable drain pipe line system upto ground level for dropping out the water outside from evaporator unit and making electric connection with three core copper cable of suitable size and making hole on wall / roof and making good all disturbed surface as per existingcomplete all as specified and directed.
43Supply, fixing, commissioning and testing of 3 star rated wall mounted split AC, dual invertor based with cooling and heating function and digital inverter type complete set of hi wall split type indoor and outdoor complete set of air conditioner unit with cardless remote control and full filling of initial refrigent gas alongwith having inbuilt heating and cooling arrangement and digital inverter twin rotary type compressor suitable for AC of rating capacity 1.5 TR and suitable for operation of 230Volt 50Hz single phase electric supply including provn of MS stand & bracket for fixing of outdoor and indoor unit system and also providing of both type /size sunction and discharge coper refrigerant piping attachment system of any length and duly both connected it from outdoor unit to indoor unit system alongwith duly overlapped it by nitrile insulation, with insulation taping work and suitable drain pipe line system upto ground level for dropping out the water outside from evaporator unit and making electric connection with three core copper cable of suitable size and making hole on wall / roof and making good all disturbed surface as per existingcomplete all as specified and directed.
44Supply, fixing, commissioning and testing of wall mounting hanging based automatic digital operation based voltage stabilizer with copper winding based unit of single phase naturally air cooled indoor type with having digital display and suitable for operation on single phase AC supply and with having designed voltage for input & output voltage 90 volt to 230 volt with accuracy +2.5% and having low and high voltage cut low voltage cut off 90 (-) 5 volts high voltage cut off 230 V (+5) Volts along with start time delay system with time delay adjustable from 30 second to 1.5 minutes system complete unit set of rating capacity 5 KVA complete system all as specified and directed.
45M&L for sub main wiring system with two runs PVC insulated FRLS wire, 1100 volt grade with multistranded copper conductor wire of size2x6Sqmm and one run of 1x6Sqmm (Nominal area) (ISI Marked) as in earth wire any type any length drawn through in heavy dutyISI markedPVC Casing capping / PVC conduit of suitable size along with its all fittingsand connected accessories and duly fixed concealed on wall or surface on wall and making electrical connection complete all as specified and as directed.Note:- 3 runs of 6sqmm wire and one run of PVC cassing capping/conduit shall be measured and 1.0 RM.
46S&F sheet metal enclosure duly powder coated with single pole and neutral enclosure with having a two pin and earth plug & top and mounting channel with one MCB DP 20 Amp and making all necessary electrical connection and dully fixed surface on wall or concealed in wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surfacecomplete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail