Tamil Nadu Newsprint And Papers Limited-TNPL has published Tender For Miscellaneous Electrical Works In Energy Department At Tnpl Unit - Ii. Submission Date for this Tender is 23-05-2024. Electrical Maintenance Tenders in Tiruchirappalli Tamil Nadu. Bidders can get complete Tender details and download the document.
FileName | File Description | File Size |
fbc15863-1367-4e4c-927b-f8dd257cfa3a.html | Tender Notice | 0 KB |
BOQ_537589.xls | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Tendernotice_2.pdf | Tender Document | 0 KB |
Tendernotice_3.pdf | Tender Document | 0 KB |
Tendernotice_4.pdf | Tender Document | 0 KB |
Tendernotice_5.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | 8337500379 Street Light: Dismantling/fixing of 75W / 150W 250W / 400W light fittings with control gear at elevations upto 30 Mtr. |
2 | 8337500375 Earthing Systems: Renovation of earth pit - Installation of equipment grounding system for indoor and outdoor equipment like motors, panels, MCCs, light fittings, DBs, Transformer, Generators etc and trays and grounding of structures, etc. |
3 | 8337500376 Street Light: Installation of street light poles with a pole pit of 0.75 x 0.75 x 1.0M, erection of pole, concreting with 1:3:6 mix, cutting and bending of 50mm dia GI pipes for loop in /loop out in marshalling box, fixing and commission |
4 | 8337500377 Street Light : Dismantling of street light poles. |
5 | 8337500373 Surface wiring (Reaper or PVC Conduit) (Length between switch boards): Telephone wire in PVC conduit - For additional runs (more than one cable) in the same PVC Pipe |
6 | 8337500380 Street Light : Dismantling / fixing of single / Twin type tube light fittings / Ceiling Fans at elevations upto 10 Mtr. |
7 | 8337500381 Post top lantern/75W street light fitting: Installation of above luminaire on MS/GI post with a pole pit of 0.5 x 0.5 x 0.5 Mtr. Concreting with 1:3:6 mix, installation of marshalling box with loop in and loop out cabling, Cement |
8 | 8337500384 Removal of XLPE insulated steel wire armoured aluminium conductor cable and wind the removed cable in drum / or as coil and shifting it to cable yard or other location as instructed by Engineers - 11 KV, 3 Core x 300 sq.mm Cable & above |
9 | 8337500383 Excavation upto a depth of 1 mtr for laying the above cable sizes and for communication cables wherever necessary 2" sand cushioning and 3 side brick laying, refilling trench including cost of sand, brick etc. |
10 | 8337500387 Wiring in Industrial area: Wiring of armoured/ power cable in conduit from switch board to individual light/fan etc including installation of switch board and fitting for the following along with earth wire-Single/Twin tube light fitting |
11 | 8337500388 Wiring in Industrial area: Wiring of armoured/power cable in conduit from switch board to individual light/fan etc including installation of switch board and fitting for the following along with earth wire - Fan with regulator / exhaust fan |
12 | 8337500389 Wiring in Industrial area:Wiring of armoured/ power cable in conduit from switch board to individual light/fan etc including installation of switch board and fitting for the following along with earth wire-Mercury vapour/sodium vapour lamp |
13 | 8337500390 Wiring in Industrial area: Wiring of armoured/ power cable in conduit from switch board to individual light/fan etc including installation of switch board &fitting for the following along with earth wire - Electrical appliances upto 1.5KW |
14 | 8337500391 House Wiring: Concealed wiring: Wiring in concealed PVC conduit of appropriate size between Main switch board and sub main switch boards to individual light/fan/power socket etc., using 7/20 or 3/20 PVC wire along with earth wire. |
15 | 8337500392 House Wiring: Concealed wiring: Telephone wire in concealed PVC conduit- For single run (One Cable) |
16 | 8337500393 House Wiring: Concealed wiring: Telephone wire in concealed PVC conduit - For additional runs (more than one cable) in the same PVC Pipe |
17 | 8337500397 Fixing of pull chord switch (Fabrication, fixing angles, welding & fixing the switch) |
18 | 8337500398 Fixing of pull chord rope hook (Fabrication of hooks & welding) |
19 | 8337500400 Termination of LT cable / straight through joint after laying upto 2.5 sq.mm |
20 | 8337500402 Cable laying and Termination work: Laying of L.T. power and control cables including charges for laying, dressing and clamping of cables - in racks, trays, in concrete shafts/underground excluding excavation and back filling upto 2.5 sq mm |
21 | 8337500406 Wiring in Industrial area: Wiring of armoured/ power cable in conduit from switch board to individual light/fan etc including installation of switch board and fitting for the following along with earth wire - Single phase power socket |
22 | 8337500407 Wiring in Industrial area: Wiring of armoured /power cable in conduit from switch board to individual light/fan etc including installation of switch board and fitting for the following along with earth wire - 3 phase power socket |
23 | 8337500412 Cleaning of slots and preparing stator for rewinding - Upto 10KW |
24 | 8337500418 Painting of Motors - cleaning the surface, applying one coat of redoxide paint followed by 2 coats of smoke grey paint (supply of paint shall be in the scope of TNPL).Use of thinner for any exigency - shall not exceed 3% upto 10 KW |
25 | 8337500419 Painting of Motors - cleaning the surface, applying one coat of redoxide paint followed by 2 coats of smoke grey paint (supply of paint shall be scope of TNPL). Use of thinner for any exigency - shall not exceed 3% abv 10 Kw&upto 30 KW |
26 | 8337500420 Painting of Motors - cleaning the surface, applying one coat of redoxide paint followed by 2 coats of smoke grey paint (supply of paint shall be scope of TNPL). Use of thinner for any exigency - shall not exceed 3% abv 30 Kw&upto 75 KW |
27 | 8337500421 Excavation upto a depth of 600mm for laying the above cables sizes, 2" sand cushioning and 3 side brick laying refilling trench including cost of sand, brick etc. |
28 | 8337500422 Excavation and back filling of cable trench upto a depth of 600mm including removal of old sand and bricks, relaying the same or providing inverted V shaped concrete coverings supplied by TNPL wherever applicable. |
29 | 8337500423 Removing of the following cable sizes from racks/ trays in concrete trenches/overhead trays/ vertical shafts/undergrounds - upto 2.5 sq.mm |
30 | 8337500427 Installation of earth pit including supply of charcoal and clay and brick chamber and laying and connection of earth pit to MSB - Excavation depth - 1.75 Mtr. |
31 | 8337500429 Cutting of blacktop / concrete road and excavation upto a depth of 1000mm for laying pipes for cable crossing and refilling trench exclusing repair of blacktop / concrete |
32 | 8337500431 Cable Trays, Supports, Frames and Misc. Steel Fabrication Works: Cable removal/fixing/ replacement of push button stations and/or canopy for the same. |
33 | 8337500432 Surface wiring (Reaper or PVC Conduit) (Length between switch boards): Telephone wire in PVC conduit -For single run (One Cable) |
34 | 8337500433 Earthing Systems: Installation of equipment grounding system for indoor and outdoor equipment like motors, panels, MCCs, light fittings, DBs, Transformer, Generators etc and trays and grounding of structures,- Earthing using 50x6 GI/copper |
35 | 8337500434 Earthing Systems: Installation of equipment grounding system for indoor and outdoor equipment like motors, panels, MCCs, light fittings, DBs, Transformer, Generators etc and trays and grounding of structures,- Earthing using25x3 GI/copper |
36 | 8337500440 Dismantling / fixing of single / Twin type tube light fittings / Ceiling Fans at elevations upto 10 Metre |
37 | 8337500442 Excavation upto a depth of 450mm and laying of Co-axial Cable in PVC pipe and refilling the trench without sand and brick |
38 | 8337500443 Laying of XLPE insulated steel wire armoured aluminium conductor cable in the cable trays including dressing of cables - 11 KV, 3 core x 300 sq.mm cable & above |
39 | 8337500430 Cable Trays, Supports, Frames and Misc. Steel Fabrication Works:Fabrication and erection of MS cable trays, supports, frame and Misc.Steel fabrication work including one anti-rust coat of primer ,two finished coats of approved enaml paint |
40 | 8337500745 LAYING OF CABLE SIZE ABOVE 2.5 & UP TO 16 SQ MM |
41 | 8337500746 LAYING OF CABLE SIZE 35 SQ MM |
42 | 8337500747 LAYING OF CABLE SIZE 70 SQ MM |
43 | 8337500748 LAYING OF CABLE SIZE ABOVE 70 & UP TO 185 SQ MM |
44 | 8337500749 LAYING OF CABLE SIZE 240 SQ MM |
45 | 8337500750 LAYING OF CABLE SIZE 300 SQ MM |
46 | 8337500739 REMOVING OF CABLE SIZEABOVE 2.5 & UP TO 16 SQ MM |
47 | 8337500740 REMOVING OF CABLE SIZE 35 SQ MM |
48 | 8337500741 REMOVING OF CABLE SIZE 70 SQ MM |
49 | 8337500742 REMOVING OF CABLE SIZE ABOVE 70 & UP TO 185 SQ MM |
50 | 8337500743 REMOVING OF CABLE SIZE 240 SQ MM |
51 | 8337500744 REMOVING OF CABLE SIZE 300 SQ MM |
52 | 8337500752 Cable termination 2.5 sq mm & up to 16 sq mm |
53 | 8337500753 Cable termination of 35 sq mm |
54 | 8337500754 Cable termination of 70 sq mm |
55 | 8337500755 Cable termination above70 sq mm & up to 185 sq mm |
56 | 8337500756 Cable termination of 240 sq mm |
57 | 8337500757 Cable termination of 300 sq mm |
58 | 8337500720 CABLE TRENCH CLEANING |
59 | 8337500721 Removing of Electrical scrap |
60 | 8337500011 Helper - TNPL Unit II |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail