Tender For Repairs / Replacement And Day To Day Comprehensive Maintenance Of Electric Pump / Starters And Suction Delivery Lines, Cleaning Of Oh / Ug Sump At Afs Harni Airfield Area Baroda And Misc Work At Makarpura And Harni Airfield At Afs Vadodara, baroda-Gujarat

Military Engineer Services-MES has published Tender For Repairs / Replacement And Day To Day Comprehensive Maintenance Of Electric Pump / Starters And Suction Delivery Lines, Cleaning Of Oh / Ug Sump At Afs Harni Airfield Area Baroda And Misc Work At Makarpura And Harni Airfield At Afs Vadodara. Submission Date for this Tender is 21-05-2024. Electrical Maintenance Tenders in baroda Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

43327367
Tender For Repairs / Replacement And Day To Day Comprehensive Maintenance Of Electric Pump / Starters And Suction Delivery Lines, Cleaning Of Oh / Ug Sump At Afs Harni Airfield Area Baroda And Misc Work At Makarpura And Harni Airfield At Afs Vadodara
Open Tender
Indian
Gujarat
baroda
21-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repairs / Replacement And Day To Day Comprehensive Maintenance Of Electric Pump / Starters And Suction Delivery Lines, Cleaning Of Oh / Ug Sump At Afs Harni Airfield Area Baroda And Misc Work At Makarpura And Harni Airfield At Afs Vadodara

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

Attachment

FileName File Description File Size
2abca7c8-4441-431b-94b1-7129d81023c6.html Tender Notice 0 KB
8892GeneralPage.pdf Tender Document 0 KB
BOQ_730741.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : REPAIRS / REPLACEMENT AND DAY TO DAY COMPREHENSIVE MAINTENANCE OF ELECTRIC PUMP / STARTERS AND SUCTION DELIVERY LINES, CLEANING OF OH / UG SUMP AT AFS HARNI AIRFIELD AREA BARODA AND MISC WORK AT MAKARPURA AND HARNI AIRFIELD AT AFS VADODARA
Sl. No. Item Description
1Attending compllaint /Repair/rectification of leakages to under ground water supply distribution lines 50 mm dia HDPE/PVC/PPR/ GI tubing with provision of necessary excavation, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of HDPE/PVC/PPR/GI unions/sockets/nipples as required at site complete all as specified and directed. Note :Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
2Description all as per item No 1.00 here-in-above but for GI tubing 80 mm dia
3Attending routine compliants of over ground /on wall/on roof external water supply line including rectification of minor defects by taking down of existing HDPE/PVC/GI tubing up to 25 mm dia, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of gate valve/float valve packing sheet of gate valve and including replacement of HDPE/PVC/ GI nions/sockets/nipples etc as required at site complete all as specified and directed. Note :Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
4Description all as per item No 3.00 here-in-above but for GI/HDPE tubing 32 mm dia to 50 mm dia.
5M & L for Detection of leakage in main water line and attending break down of water supply pipe line and repair to CI /DI/HDPE water mains of size 80 mm to 100 mm dia at a given notice including necessary excavation in mud, in any type of soil by manual or using special T &P such as JCB etc.De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/DI/HDPE specials such as collars bends/tail peaces etc and making joints complete all as specified and directed. Note:-(i) Repair rectified by cokking of CI pipeare deeemed to be incuded with unit rate of job. (ii) CI specials, lead Joints, D-Joints, Clamp joints, mechanical joint etc shall be measured and paid under respective items of sch "A".
6Description all as per item No 5.00 here-in-before but for CI/DI water mains of size 150 mmbore.
7Description all as per item No 5.00 here-in-before but for CI water mains of size 200 mm bore.
8Notes for Sl item No 1 to 7:- (a)The contractor will be alloted complaints at MES complaint cell on daily basis on all working days and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b)A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c)The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard.
9(d)The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e)The quoted rated is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f)The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/Mand the same shall be submitted to E/Mstore yard on daily basis. (g)The stationery required for the job work such as complaints registers, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall be deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account. (j) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
10Supply only GI Fittings15 mm bore medium grade , ISI marked, smooth finished and make embosed on fittings complete all as specified and directed for the following :-
11Union
12All equal Tee
13Socket
14Nipple 75 mmLong
15Nipple 100 mmLong
16Nipple 150 mm long
17Nipple 200 mm long
18Nipple 300 mm Long
19Elbow
20Supply only GI Fittings20 mm bore medium grade , ISI marked, smooth finished and make embosed on fittings complete all as specified and directed for the following :-
21Union
22All equal Tee
23Socket
24X-Nipple
25Nipple 75 mmLong
26Nipple 100 mmLong
27Nipple 150 mm long
28Nipple 200 mm long
29Elbow
30Reducer 20 mm x 15 mm
31Supply only GI Fittings25 mm bore medium grade , ISI marked, smooth finished and make embosed on fittings complete all as specified and directed for the following :-
32Union
33All equal Tee
34Socket
35Nipple 75 mmLong
36Nipple 100 mmLong
37Nipple 150 mm long
38Nipple 200 mm long
39Nipple 300 mm Long
40Elbow
41Reducer 25 mm x 15 mm
42Reducer25mm x 20 mm
43Supply only GI Fittings40 mm bore medium grade , ISI marked, smooth finished and make embosed on fittings complete all as specified and directed for the following :-
44Union
45All equal Tee
46Socket
47X-Nipple
48Nipple 75 mmLong
49Nipple 100 mmLong
50Reducer 40 mm x 25 mm
51Reducer40mm x 20 mm
52Elbow
53Supply only GI Fittings50 mm bore medium grade , ISI marked, smooth finished and make embosed on fittings complete all as specified and directed for the following :-
54Union
55All equal Tee
56Socket
57X-Nipple
58Reducer 50 mm x 40 mm
59Reducer50mm x 25 mm
60Elbow
61Supply only HDPE Fittings80 mm bore medium grade , ISI marked, smooth finished and make embosed on fittings complete all as specified and directed for the following :-
62Coupler
63All equal Tee
64Elbow
65Reducer 80 mm x 50 mm
66Supply and fixing of 20 mm ball brass float valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule incl. connector of suitable size and fixed on roof top water tank complete all as specified and directed
67Supply and fixing of25 mm ball brass float valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferruleincl. connector of suitable size and fixed on roof top water tank complete all as specified and directed
68Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying/taking out of cables,CI/GI pipe lines and getting out in sooft/loose soil all as specified and directed.
69Returning, filling in trenches including spreading, levelling watering and well ramming in layers not exceeding 25 cms insoil complete all as specified and directed
70Removal of excavated material and deposited where directed at a distance not more than 50M from starting point and not more than 1.5Mabove ground level complete all as specified and directed
71Taking out unserviceable CI/GI water main from trenches including fittings / fixtures like bend, Tee, Union, Elbow etc with flanged endsall as specified and as directed Note: Excavation and earthwork will be measured and paid separately under respective item of BOQ.
72200/150 mm bore CI pipe/ DI Pipe
73100 mm bore CI pipe/DI Pipe
7480mm bore CI pipe/DI Pipe
7580 mm bore GI pipe
7640mm bore GI pipe
7750 mm bore GI pipe
7825mm bore GI pipe
7920mm bore GI pipe
80Relaying of old serviceable CI/GI tubing obtained from Srl item No. 19.00 here-in-before above after cleaning the pipes internally and externally with all fittings laid in trenches, floor, under road wall ceiling, floors etc for following sizes complete all as specified and directed:-
81200/150 mm boreCI pipe/DI Pipe
82100 mm boreCI pipe/DI Pipe
8380 mm boreCI pipe
8480 mm bore GI pipe
8550 mm bore
8640 mm bore
8725 mm bore
8820mm bore GI pipe
89Supply and laying CI/DI pipes,with spigot and socket centrifugally cast, class LA, confirming to IS-1536 of 2001 in any length laid in trenches or on supports including making alteration in existing /new pipe line for insertion of new pipe if necessary of following sizes complete all as specified and directed
90200 mm bore
91150 mm bore
92100 mm bore
9380 mm bore
94Supply and fixing ofHigh density polyethylene pipes (HDPE) PE-80 with SDR-17of pressure rating 6 kgf/cm2 fixed complete to laid in trenchesincluding taking down existing unserviceable pipes with smooth finished and make embosed on pipe complete all as specified and directed for the following :-
95100/80 mm bore
9650 mm bore
9740 mm bore
9825 mm bore
99Supply & laying in trenches/ Walls 20mm GI pipe medium grade, ISI marked with GI fitting such as tees,bend,elbows connecting to existing water main complete all as specified and directed
100Description all as per item No 23.00 here-in-before but 25mm bore GI tubing.
101Description all as per item No 23.00 here-in-before but 40mm bore GI tubing.
102Description all as per item No 23.00 here-in-before but 50mm bore GI tubing.
103Description all as per item No 23.00 here-in-before but 80mm bore GI tubing.
104Supply and fix accessories, CI/DI specials confirming to relevant IS (any type radius and angle) such as bends, tapers, straight, increasing / decreasing or double socket / flanged end collars, connecting pieces etc, as required at site and for the size upto 300mm bore complete all as specified and as directed Note :Lead joints and jointing material shall be measured and paid in above item.
105S&F display board of Pumpsets, Motors, Open well, Bore well, starter panels, monoblock pumpsets, chlorination plants etc of size 60cm x 30cm x 20mm thick made of two layer acrylic sheet including relevent letter of size 7cm height and 1.5cm thick of white colour on blue layer sandwitched between two acrylic layers, including fixing, rivetting or screwing on the wall complete all as specified and directed
106Supply and fixing of mechanical Joint (MJ) fittings of various sizes and various depth of any type radius and angle) such as tapers, straight, increasing / decreasing or double socket / flanged, connecting pieces etc, as required at site and for the folowing sizes complete all as specified and directed
107200/250 mm bore
108150 mm bore
109100 mm bore
11080 mm bore
111Dismantling / Taking down unserviceable Gun metal globe/gate valve and supply and fix new Gun metal globe / gate valve, screwed down high pressure with iron wheel head, screwedboth ends for GI/PPR pipe including all fittings / fixtures like nipple, union etc complete for following sizescomplete all as specified anddirected
11250 mm bore size
11340 mm bore size
11425 mm bore size
11520 mm bore size
116Supply & fix SS Spindle CI sluice valve PN 1.6, long body, confirming to IS- 14846 : 2000.Complete and testing complete all as specified and directed including dismantling of sluice valve of following sizes:-
117150 mm bore sluice valve
118100 mm bore sluice valve
11980 mm bore sluice valve
120Construction of brick masonry valve pit chamber of inner dimension 900x900x1050mm suitable for valves up to 200 mm size, with PCC 1:4:8 type D-2 for foundation, brick work in CM 1:6, rendering in CM 1:4, 15 mm thick mixed with water proofing compound, coping in PCC 1:2:4 type B-1, including necessary earth work, form work and provision of MS sheet cover of thickness not less than 2.80 mm on 50 x 50 x 6.0 mm Angle iron frame with locking arrangement, including painting over MS surfaces with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed
121Description all as per item No 29.00 here-in-before but valve pit chamber of inner dimension 450mm x 450mm x 600mm complete all as specified and directed
122M&L for preparing the surface of each Pump- Motor set of any capacity with sluice valve including scrubbing down with iron brush/sand paper etc and applying two coats of synthetic enamelled paint complete all as specified and directed
123M&L for painting of CI/GI pipes at pump houses such as suction and delivery main with two coats of synthetic enamel paint as per MES colour code including preparation of surfaces complete all as specified and directed.
124S&Fin replacement three core flat copper cable, PVC insulated, PVC sheathed for submersible pump set 1100 volt 4 sqmm size after taking down the old UNSV copper cable complete all as specified and directed.
125S&Fin replacement Pressure gauge suitable for bearing pressure upto 20 Kg / Sq cm. complete all as specified and directed Make : MEI /GURU /Uday
126M&L for cleaning of under mentioned RCC over head reservoir/under ground sump/semi under ground sump of any size and any height of staging by using mechanical means and scientific cleaning by carry out the following stages of cleaning process for disinfection of surfaces complete all as specified and directed:- (a) Cleaning of all external surfaces with hot water and Odor removal. (b) The inner surface of the walls and ceilings of the tank shall be cleaned with the pressure jet pump after dewatering in the tank. (c) After through cleaning of the tank, removal of algal calcination and other dust particles with high pressure including hot water treatment @50 degree centigrade. (d) Vacum cleaning and sludge shall be removed by using pump and the sludge has to be disposed off at a places as directed. (e) After removing the sludge from tank, the floor and inner surfaces of the tank shall be cleaned by using an industrial vaccum cleaner and the tank shall be made fully dust free and disinfection with bio-degradable chemical/anti bacterial spray and surfaces to be proven non toxic.
127(f) After the treatment as mentioned at (e) above, the inner surfaces of walls and ceiling shall be traeated with UV Radiation/Ozonization with UV rays. (g) After complete treatment is carried out, all inlet, over flow, delivery, wash out pipes, ladder and doors shall be painted with two coats of synthetic enamel black paint after thorough cleaning the surface and also the surfaces of sluice valves shall be painted with P.O. Red paint and writing"capacityof tank, date of cleaning and due date of cleaning" on waqlls as specified and as directed.
12820000 Gallon (UG Sump)
12935000 Gallon (OH tank)
130100000 Gallon (Semi UG sump)
13110000 Gallon (UG Sump)
132Flushing / de-silting of accumulated soilfrom inside the borewell up to 250 mm dia and depth up to 150 meter by using air compressor/ special equipmentsof existing borewellsincluding surgingand flushing the bore at a pressure of 7 Kg / Sq cm complete with compressed air andflushing the sand, mud etc from the bore well till discharge of the fresh water, including testing of watersamples for chemical and bacteriological tests and yield testing for 4 hours complete all as specified and directed . Note: The rate shall be inclusive of hiring of Air compressor /special equipment, diesel, tools and Accessories including transportation and skilled man power to execute the work complete all as specified and directed
133Supply and fix Gland packing for sluice valve and pumps of size 6mm thick complete all as specified and directed.
134M & L for dismantling of defective sluice valve for repairssuch as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly replacement of jointing materials such as rubber sheets, nuts, bolts & washers, gland rope and refixing in its original position, testing on completion etc complete all as specified and directed of following sizes:-
13580 mm bore.
136100 mm bore.
137150mm bore.
138200mm bore.
139M & L for Framed work as in doors or gates of angle (40 x 40 x 5) or other section with gasket plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete with locking arrangement complete all as specified and directed (Under ground Sump)
140M & L for Mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up and welding handle for lifting, mitred angles, etc. as required for size 2.0mm complete all as specified and directed
141M & L Drilling and tapping cast iron/GI water mains (in position) for branch connections of the internal dia including ferrule of 20 mm bore size complete all as specified and directed
142Labour only for Disconnecting the existing non functional submersible pump set of capacity upto 10 HP from electric supply from panel, dismantling existing CI bend from non return valve, removing and lifting out submersible pump set of any description and capacity & in any position, along with existing column pipe 50mm dia and existing submersible cable of any size from the bore well (approximately 450 feet depth of pump set from GL) and staking the pump and column pipes near by the bore well for inspection complete all as specified and directed
143Description all as per item No 42.00 here-in-before but 50 HP pump set
144NOTE: - (i). Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc. shall be arranged by the contractor at his own cost. (ii). Number of column pipe may vary from 30 to 50, The existing pipes & flanged joints shall be checked for its serviceability & unserviceable joints along with flanges shall be removed from the column pipe by cutting the pipes & making new thread in pipes for fixing of new flange joint, the cost of same shall be deemed to be included in the quoted rate for above item. However cleaning of pipes if any required shall be measured & paid separately.
145Lowering down of the submersible pump set of any description and any capacity & in any position using the chain pulley arrangement from bore well along with column pipe 50 mm dia and submersiblecable of any size (approximately 450 feet depth of pump set from GL) complete all as specified and directed including making necessary electric connections & testing the pump set after lowering.
146Supply only the following items/ spare parts suitable forsubmersible pump set of upto 10HP capacity dismantled under item No 42.00 here-in-before complete all as specified and directed
147Cast iron stage bowl
148Gun metal neck ring make NITCO’ or equivalent
149Anti magnetic stainless steel pump shaft with key made : DD/’KSB or equivalent
150Impeller gunmetal make: NITCO/ KSB or equivalent
151Stainless steel sleeve( inlet) make : DD/KSB or equivalent
152Stainless steel sleeve( outlet) make : DD or equivalent
153Running bush outlet of gun metal
154Stage bowl cover
155Bolt stud with nut and washers
156Running bush inletofgun metal
157Strainer stainless steel
158Shaft nut with washer
159Connector for motor
160Steel bolt set
161Key for thrust plate
162Thrust bearing[set of 02]
163Cable pressure washer
164Thrust plate
165Motor bearing bush (LB)
166Thurst bearing set
167PVC Impeller
168Stage casing
169Stage casing sleeves
170Suction bush
171Pump NRV
172Discharge out let Bush LB
173Discharge out let.sleeve
174Middlebush LB
175Middle sleeve
176Pump Shaft
177Neck ring stage casing
178Sand guard
179Oil sealing
180Supply only the following items/ spare parts suitable forsubmersible pump set of upto 50 HP capacity dismantled under item No. 43.00 here-in-before complete all as specified and directed
181Cast iron stage bowl
182Gun metal neck ring make NITCO’ or equivalent
183Anti magnetic stainless steel pump shaft with key made : DD/’KSB or equivalent
184Impeller gunmetal make: NITCO/ KSB or equivalent
185Stainless steel sleeve( inlet) make : DD/KSB or equivalent
186Stainless steel sleeve( outlet) make : DD or equivalent
187Running bush outlet of gun metal
188Stage bowl cover
189Bolt stud with nut and washers
190Running bush inletofgun metal
191Strainer stainless steel
192Shaft nut with washer
193Connector for motor
194Steel bolt set
195Key for thrust plate
196Thrust bearing[set of 02]
197Cable pressure washer
198Thrust plate
199Motor bearing bush (LB)
200Thurst bearing set
201PVC Impeller
202Stage casing
203Stage casing sleeves
204Suction bush
205Pump NRV
206Discharge out let Bush LB
207Discharge out let.sleeve
208Middlebush LB
209Middle sleeve
210Pump saft
211Neck ring stage casing
212Sand guard
213Oil sealing
214Rewinding the submersible motor upto 5 HP of any make with PVC insulated super enameled heavy duty copper winding wire of same gauge and number of turns by using minilex fiber insulating sheet and sleeves etc, including taking out dismantling transporated to local work shop and refixed in position after rewinding complete all as specified and directed
215Rewinding the submersible motor 10 HP of any make with PVC insulated super enameled heavy duty copper winding wire of same gauge and number of turns by using minilex fiber insulating sheet and sleeves etc, including taking out dismantling transporated to local work shop and refixed in position after rewinding complete all as specified and directed
216Rewinding the submersible motor 50 HP of any make with PVC insulated super enameled heavy duty copper winding wire of same gauge and number of turns by using minilex fiber insulating sheet and sleeves etcincluding taking out dismantling transporated to local work shop and refixed in position after rewinding complete all as specified and directed
217S&F in repair of aviation LED light fitting suitable for overhead tank including necessary connection with and incl 1.5 sqmm 2 core cable 20 meter for connetion and nuts, bolts, clamps complete all as specified and directed
218Disconnecting and taking out defective MCCB after disconnecting all electrical connection and supplying, fixing, and testing MCCB, 3 pole, 415 Volt AC supply, 250 Amps having breaking capacity Icu = 35/36 KA with fixed thermal & magnetic setting complete all as specified and directed Make : Havells/C & S Electric/ HPL / Standard.
219S&F in repair of contactor 4 pole with AC coil 415 volt 50 Hz,32/40 Amp for motor starter complete all as specified and directed.
220S&F in repair of contactor 4 pole with AC coil 415 volt 50 Hz,20 Amp for motor starter complete all as specified and directed.
221Material & labour for boring of holes under road for insertion of pipe of up to 200 mm bore, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine complete all as specified and directed.
222M & L for water testing in Biological& Chemical test for various location at collection of the sample from the various site (like pump house , RO plant Bore well etc) and testing in authorised lab complete all as specified and directed .
223M & L for water installation board as per direction by Engr-in-charge including light connection andfixing arrangement complete all as specified and directed
224M & L for Taking out and rewinding of openwell submersible motor 1 HP with PVC insulated submersible rewinding wire of suitable gauge/size as per existing including rotor balancing, testing and connection of submersible cable and cable gland including taking down old winding wire complete all as specified and directed.
225S&F in repair sensor system of pressure booster pump of 1 HP including testing on ground complete all as specified and directed.
226M & L for rewinding of monoblock/ Centrifugal pump (Motor), 3 phase, 415 voltwith super emamelled copper rewinding wire of suitable size/gauge as existing and providing insulation varnishing, heating, testingincluding taking out the existing winding wire complete all as required for completion of JOB for following capacity pumps:-
227Motorof capacity 40 HP/50HP
228Motorof capacity 30 HP
229Motorofcapacity 25 HP
230Motorofcapacity 12.5 HP
231Motorofcapacity 7.5 HP
232Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 50/40 HP having discharge 400 LPM at 990 mtr head complete all as specified and directed
233Motor bearing . Make : SKF/NBC/TATA/FAG/ UBC.
234Motor cooling fan
235Pump motor MS coupling
236L-190 spider.
237Cover bolts & washers
238Pump bearing No. 6307 of Make : SKF/UBC/TATA/FAG/ NBC
239CI impellar DB 80/20 for existing 50/40 HP centrifugal pump set.
240CI Gland packing chaplla
241SS Sleeve (Gland Sleeve)
242Pump shaft with studs and nuts for pump body.
243Starter relay of Make : Jyoti, Range 36-60
244Magnet coil of MakeJyoti.
245Starter copper contact set
246Starter oil.
247Starter base plate
248Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 25 HP complete all as specified and directed
249Motor cooling fan
250Pump motor MS coupling
251L-190 spider.
252Cover bolts & washers
253Pump bearing Make : SKF/UBC/TATA/FAG/ NBC
254Motor bearing of Make : SKF/UBC/TATA/FAG/ NBC
255CI impellar suitable for existingpump set.
256CI Gland packing chaplla
257SS Sleeve (Gland Sleeve)
258Pump shaft with studs and nuts for pump body.
259Supply and fix in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 12.5/7.5 HP complete all as specified and directed
260Motor cooling fan
261Pump motor MS coupling
262L-190 spider.
263Cover bolts & washers
264Pump bearing Make : SKF/UBC/TATA/FAG/ NBC
265Motor bearing of Make : SKF/UBC/TATA/FAG/ NBC
266CI impellar suitable for existingpump set.
267CI Gland packing chaplla
268SS Sleeve (Gland Sleeve)
269Pump shaft with studs and nuts for pump body.
270Supply and fix in repair fully automatic star delta starter of following capacity all as specified and directed.
271For 50/40 HP motor
272For 25 HP motor
273For 12/7.5 HP motor
274Supply and fix in repair of submersible pump motor starter of 5 HP as suitable at site complete all as specified and directed.
275S&F Chemical feed dozer model RC series Chemical Dosing (metering) Pump electromagnetic type with suction & discharge tubing, spring loaded anti siphon valve, foot valve etc complete with maximum discharge of 6 ltrs / hr with 4 kg back pressure motor operated suitable for mixing hypo chloride of capacity 100 ltr tankwith stroke adjustment of 0 to 6 LPH complete with fittings and piping network complete all as specified and directed
276Supply & provide Aquafit (Calcium hypo chlorite)65%-70% chlorine content (Calcium based granular desinfectant for water treatment plants much more stable than chlorine gas & stronger than bleaching powder and sodium hypo chlorite packed in 45 Kg drum complete all as specified and directed. Make : Auafit & Equivalent.
277Supply of water through tanker/bouserincluding transportation from source to U/G sump Harni camp/Harni Air field area Afs Baroda. The water should have the following main factors :- (a) Water should be clear and from all suspended matters both Hyganic & inorganic matter. (b) Water should be free from taste and odour. (c) Water should be colour less and no vegetable stain should be present. (d) Water should be soft that it should not contain dissolved impurities like calcium or magnesium bicarbonate and Sulphates. (e) Water should be soft and should be free from all pathogenic organism causing diseases. (f) Copy of gate entry at guard room with vehicle No date and time shall be submitted duly defaced by Engr in charge before claiming payment. Note : Water analysis duly tested by authorised lab will be rendered by supplier before supplying the water.
278M & L for cleaning of static water tank (SWT) 100000 Ltrs with all T&P and man power requered to pump out the existing water and removing the sludge and greet from 6f ft deep water collector and thowing it out side 50Mtr away from site complete all as specified and directed.
279Supply and fixing of brass foot valve of following sizes incl lifting of UNSV foot valve from UG sump from any depth by removing of suction pipes of pumps complete all as specified and directed
280100mm dia pipe
28180 mm dia pipe/50 mm dia
282Supply and fixing of brass NRV of following sizes incl lifting of UNSV foot valve from UG sump from any depth by removing of suction pipes of pumps complete all as specified and directed
283100mm dia pipe
284For 80 mm dia pipe/50 mm dia
285Labour only for opening of defective star delta starter and starter panel of any capacity or make incl replacement of defective item and starter shall made functional complete all as specified and directed Note-: Accessories of starter shall be measured and paid separately.
286Supply only push button of Red/Green colour complete.
287Contactor coil for starter
28825A 2P Contactor for starter
289M & L for dismantling of defective sluice valve for repairs/replacement of spindle with gate including nut bolt with washers with packing and refixing at its original position, testing on completion etc complete all as specified and directed of following sizes:-
29080 mm bore.
291100 mm bore.
292M&L for cleaning once in a month by spraying of weeds herbicide for kill unwanted vegetation around near E/M installation, cutting grass, removing unwanted bushes, removing debris etc and making good of undulated ground by filling fresh soil and levelling the area to existing ground level, removing unwanted debris from the premises at a distance above 50m from site complete all as specified and directed. Note: (i) Location - Harni Pump house, Semi UG tank area and Aircraft pumphouse, Semi UG tank area approx area -450 SQM. (ii) In case of damage to any existing assets such as UG cables, Pipelines or any type of things, contractor has to make good as per the existing.
293Demolition of old PCC foundation any type and size including removal of anchor bolt and removing debris from site at safe place as eco friendly manner complete all as specified and directed
294M&L for PCC work for pumpset platform and other misc pedestal supports, type C1, mixing ratio 1:3:6 using 20mm gradded aggregate complete including form work etc complete all as specified and directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail