Tender For Day To Day Repairs/ Maint, Complaint Of Electric Geysers, Ceiling Fans, Exhaust Fan, Wall Fan And Connected Items In Md And Otm Accn Under Ge (Mcte) Mhow, Indore-Madhya Pradesh

Military Engineer Services-MES has published Tender For Day To Day Repairs/ Maint, Complaint Of Electric Geysers, Ceiling Fans, Exhaust Fan, Wall Fan And Connected Items In Md And Otm Accn Under Ge (Mcte) Mhow. Submission Date for this Tender is 28-05-2024. Ceiling Fan Tenders in Indore Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43327341
Tender For Day To Day Repairs/ Maint, Complaint Of Electric Geysers, Ceiling Fans, Exhaust Fan, Wall Fan And Connected Items In Md And Otm Accn Under Ge (Mcte) Mhow
Open Tender
Indian
Madhya Pradesh
Indore
28-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Day To Day Repairs / Maint, Complaint Of Electric Geysers, Ceiling Fans, Exhaust Fan, Wall Fan And Connected Items In Md And Otm Accn Under Ge ( Mcte ) Mhow

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

Attachment

FileName File Description File Size
1235c487-31e2-4a2f-bba4-eaff6d01a884.html Tender Notice 0 KB
BOQ_730708.xls Tender Document 0 KB
Make17T.pdf Tender Document 0 KB
PS-17T.pdf Tender Document 0 KB
TD17T.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : Day to Day Repairs/ Maint, Complaint of Electric Geysers, Ceiling Fans, Exhaust Fan, Wall Fan and Connected Items in MD and OTM Accn under GE (MCTE) Mhow
Sl. No. Item Description
1Identifying and rectifying the complaints pertains to ceiling fans/ exhaust fans/ wall fans/ table fansand connects electric circuit, tightening of loose wirring/ conduits/ fan capacitors and connection carrying out minor repairs incl blade alignments, screwing/ tightening the nuts/ bolts/ washers etc incl taking down & refixing properly in the same position after repairs, complete all as specified and directed.
2Identifying and rectifying the defects pertaining to Geyser of any type and nature such as taking down defective switch/ socket/ AC Box/ MCB SP, loose connection, wiring short circuit any type, removing air lock or checking & replacing heating element/ thermoastat/ indicator/ PVC connection/ geyser plug top/ 15 Amps switch & sockets, rectification of faulty electric circuits,tightening of loose connections, replacment of old u/s wiring/ conduits/ casing caping & connections etc. complete all as directed.
3NOTE FOR ITEM NO 1 to 2 :- (a)All T & P and labour team required comprising of Nos of trained electricians & helpers will be provided by the contractor daily, as directed. (b) Repof the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 04.30 Hrsthe time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed & on contractor. (c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size etc shall be deemed included in the above quoted item. However, major items such as switches, sockets, bell push, fan regulator etc shall be measured and paid separately under appropriate items of Schedule "A". (d) Complaints, where complete replacement of circuit/point wiring required shall be measured under relevent item.
4Supply and fix in replacement of PCB with sensarfor BLDC fan suitable for exisiting BLDC fan PCB as per samplecomplete, all as specified and directed by Engr-in-charge.
5Supply & fix in repair sheet metal enclousure with a 3 pin (2 pin and earth) plug & socket complete with one MCB SP 20 Amps of breaking capacity 10KA, "C" series, 240 volts complete all as directed.
6Supply in repairs metal clad plug and socket single pole with earth, 230 volt 20 amp complete all as specified & directed
7Dismantling of complete defective Ceiling fan of 1200 mm sweep (i.e.,) down rod with its Canopies, Shackle, Blade,Condenser housing with its rubber bushes, split pins, unscrewing the body parts of Ceiling fan, taking out starter, rotor winding,ball bearing, gun metal bush etc. complete to carry out the following repairs:-
8(a)Removing of burnt out fan winding and rewinding of starter winding with suitable size of Copper enamelled wire, (weight of copper coil shall be same as per dismantled Fan) varnishing heating and testing as per manufactures designed & specifications and as directed by Enge-in-charge. (b)Re-assembling complete Ceiling fan by fixing only serviceable of old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes,blades, ball bearing, twin twisted Copper cable, down rod assembly with its shackle condenser housing and Canopies & split pins complete all as specified and design to give designed air delivery including greasing, oiling, cleaning outer body & surfaces etc all as directed.
9All as per Item No.7 & 8 above but ceilingfan 1400mm sweep.
10All as per Item No.7 & 8 here-in-before but exhaust fan of size 230/ 300mm sweep.
11All as per Item No.7 & 8 here-in-before but exhaust fan of size 380/ 450mm sweep.
12All as per Item No.7 & 8 here-in-before but pedestal/Cabin fan/ wall fan of size 400mm sweep.
13All as per Item No.7 & 8,9 here-in-before but only overhauling of celing fan 1200mm/ 1400mm by greasing and oiling, replacement of unserviceable/ defective components, except rewinding of starter winding complete all as directed.
14All as per Item No.10 & 11 here-in-before but exhaust fan of 230 to 450mm sweep.
15Note Sl No.07 to 14 :- (a)Spare parts found unserviceable/defective will be measured and paid separately under relevant item as supply only. (b)The element for fixing of new spare parts are deemed to be included in quoted unit rate of above items.
16Supply in repairs the spare parts of Ceiling fan 1200mm/ 1400mm sweep of different make:-
17(a)Condenser of capacity 2.5 to 3.15 Microfarad, 440 Volts, AC 50 Hz, plastic-casing, two terminal-copper wire, confirming to IS 1709 complete.
18(b)Rubber bush for shackle with bolt, nut and lock pin suitable for Ceiling fan 1200mm/1400mm sweep.
19(c)Split Pin
20(d)Ball bearing of size 6201/6202 as per sample.
21(e)Gun metal bush as per sample.
22(f)Condenser 4 MFD, 440 Volts, AC 50 Hz as per IS 1709
23(g)Condenser housing, suitable for placing condensor at ceiling fan/ Exaust fan as per sample
24(h)Fan canopy pvc body, white in colour, suitable for existing fan, as per sample and directed.
25M & L for preparation of old painted/ rusted surfaces of 1200/ 1400mm sweep ceiling fan and re-fixing the same after painting of the same with white colour synthetic enamel paint by spraying including filling cavities with filler & one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter, complete all as specified and directed by Engr-in-Charge. Note:- All T&P and labour team as required will be provided by the contractor and cost deemed to be included in the quoted rate.
26S & F in repair TPN DB with provision for MCB TPN as incomer and SP MCBs as outgoing made of steel sheet phosphatised powder coated with bus bar, neutral link earth bar and DIN Rail having IP 42-IK 09 with metal door capacity 4-ways 415 V, connection with aluminium/ copper lugs including civil/plastering work for make up good the disturbed surface matching with existing surface complete all as directed.
27S & F in repairs for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driver connector block etc complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
28S&F (in replacement) MCCB 4 pole, 415 volts, in the existing panel / location and connection with using aluminum lugs complete all as specified and directed for 100 to 125 Amps rating, 16 KA breaking capacity.
29Supply and fix in repairs double door SPN DBs 8 ways of powder coated DB"s suitable for MCB"s fitted with bus bar, Neutral link, Earth bar and Din ral complete.
30Supply and fix in repairs double door SPN DBs 4 waysof powder coated DB"s suitable for MCB"s fitted with bus bar, Neutral link, Earth bar and Din ral complete.
31Supply and fix in repairs double door SPN DBs 12 ways of powder coated DB"s suitable for MCB"s fitted with bus bar, Neutral link, Earth bar and Din ral complete.
32S & Fin repairs MCB SPN 6 to 32 amps 10 KA, "C" series including connection with suitable size aluminium/ copper lugs complete all as specified and directed.
33S&F in repairs MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, "C" series including connection with suitable size aluminium/ copper lugs complete all as specified and directed.
34S & F in repair MCB triple pole & neutral 63 Amp, 415 volts, "C" series" 10 KA breaking capacity & connection complete.
35S & F in repair PVC insulatedflexible cable threecore Copper conductor of size1.00 Sqmm, ISI marked, covered with white colour round insulation complete all as specified and directed.
36S & F in repair PVC insulated flexible cable three core Copper conductor of size0.75 Sqmm, ISI marked, covered with white colour round insulation complete are as specified and direced.
37Supply and fix in repair MS down rod "medium grade" 15mm dia, in appropriate length of segments of required size of each down rod as per site requirement,including all fixing arrangments like hooks, clamps, nuts, bolts etc for hanging the ceiling fan at site, complete with making split holes, cut or threads at both end of pipe as required for hanging of Ceiling fan incl. painting of down rod with two coats of synthetic enamel white colour paint over one coat of primer complete all as specified and directed.
38S & F in repair "U" shape shackle clamp assembly incl checknut, bolts, screws, washer, lock nut, rubber reel etc and connecting, complete all as directed.
39M & L for Overhauling/ Dismantling of defective/ rusted Geyser of 25 Ltr capacity from different locations by removing inlet/outlet connections, taking out U/S parts by unscrewing bolts and nuts etc. Checking defects and re-assembling the Geyser after refixing serviceable/new parts & cleaning, dicling and refixing only serviceable items and re-installing the Geyser in suitable place/ position and connecting inlet-outlet connections & testing complete, all as specified and directed by Engr-in-charge.
40All as per item No.39 above,but capacity 50 litres geyser complete all as & directed.
41Note for Ser No. 39 & 40:- (a)Items required for replacement of U/S parts will be measured and paid separately under relevant item of sch "A". (b)The elements for Labour of new spare parts are deemed to be included in quoted unit rate of above items.
42Supply in Repairs/ Replacements of following spare parts of geyser storage type of different make for capacity 25/50 ltrs (Make of spare parts shall be of existing make or as per sample approved by GE)
43(a)Apparatus assembly duly prewired without heating element and thermostat/thermal cutout.
44(b)Indication lamp (Green/Red) as per sample.
45(c) Thermostatas per sample.
46(d)Heating element 1.5 KW, trangle base type, as per sample.
47(e)Heating element 1.5 KW, cup, base type as per sample.
48(f)Geyser "O" ring gasket as per sample.
49(g)Geyser bottom plate as per sample.
50(h)Geyser flange assembly nine holes as per sample.
51(i)Fusible plug suitable for 25/50 ltrs capacity geyser, as per sample
52(j)NRV Valve suitable for storage type geyser, 25mm, as per sample, complete as directed.
53(k)NRV Valve suitable for storage type geyser, 12.5mm (0.5"), as per sample, complete as directed.
54S & F in repair PVC connection pipes double layer, heavy duty, ISI Marked, 15mm dia both end socketed, inner threaded 450-600mm long heavy duty of suitable thickness for hot/cold water as per sample approve by GE.
55M & L for taking down existing Electric geyser storage type of any size in position and re-fixing the same after preparation of old painted/ rusted surfaces of 25/50 ltrs capacity geysers from different-different locations of MD Accn/ OTM, including painting of the same with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter, complete all as specified and directed by Engr-in-Charge.
56Supply and Fix Electronic fan regulator, five steps, hume free, Socket type, 230 V, AC, single phase connection complete all as specified & directed.
57Taking down carefully point wiring of any type complete for light, fan, bell, socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, conduit etc. including accessories including making good disturbed surface to match the existing surface complete all as directed.
58Taking down submain wiring any type and any size and making good disturbed surface and matching with existing colour complete all as directed.
59Taking down switch fuse/DB"S including MCCB/ MCB any type and any capacity complete all as directed.
60M & L for Point wiring in repairs including with PVC insulated FRLSH PVC unsheathed electric cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area for phase/neutral in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of pvc conduit surface casing caping will be used) & 1.5 sqmm green FRLSH, PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including galvanised boxes with bakelite sheet for mounting switches, sockets, fan regulators etc for the following :-
61(a)One light/ fan/ bell point controlled by one switch
62(c)One 5 Amps socket out let point controlled by one switch on SAME BOARD with other switches.
63(d)One 5 Amps socket out let point on independent board controlled by one switch.
64All as per item No.60 here in before but using pvc insulated unsheathed 2.5 sqmm cross sectional area cable for phase/ neutral & for earth 2.5 Sqmm green PVC insulated cable for 15 amps socket point on independent board controlled by one switch.
65M & L for Point wiring with PVC insulated FRLSH, PVC unsheathed cable, single core, stranded, copper conductor cable 1.5 Sqmm size, 1100V grade, drawn into with and including PVC casing-capping not less than 20mm wide, ISI marked, with 1.5 Sqmm unsheathed, stranded copper cable for continuous earth wire and including pressed steel concealed terminal boxes of reqd size made out of 1.2mm thick sheet and covered with 2.8mm thick plastic laminated bakalite (hylam) ISI marked sheet suitable for switches/ sockets/ regulators complete all as specified & directed for the following :-
66(a)One light/ fan/ bell point controlled by one switch
67(b)One point for socket outlet 5 Amp on independent board
68(c)One point for socket outlet 5 Amp on SAME BOARD
69All as per Item No 65 above, but with FRLSH cable 2.5 sqmm stranded copper conductor FRLS with 2.5 sqmm copper conductor earth wire for switch/ socket outlet 5 pin,15 Amps multipurpose on independend board.
70M&L for Point wiring with PVC insulated, FRLSH, PVC unsheathed cable, single core, stranded, copper conductor FRLSH cable 1.5 Sqmm size, 1100V grade, drawn through Existing PVC Conduit of any type and dia, with1.5 Sqmm unsheathed, stranded copper conductor FRLSH cable for continuous earth wire green colour and including pressed steel concealed terminal boxes of reqd size made out of 1.2mm thick sheet and covered with 2.6mm thick white hylam sheet cover, of suitable size for mounting switches/ sockets/ regulators or Modular flush box for mounting modular switches/ sockets/ regulators etc complete all as specified & directed for the following :-
71(a)One light/ fan point controlled by one switch
72(b)One bell point controlled by one bell push
73(c)One socket outlet 2/3 pin 5 Amp multipurpose on SAME BOARD
74(d)One switch/ socket outlet point 2/3 pin 5 Amp multipurpose on independent board
75All as per Item No.70 above, but with FRLSH cable 2.5 sqmm stranded copper conductor for switch/ socket outlet 5Pin,15 Amps multipurpose controlled with 2.5 sqmm copper conductor FRLSH cable as continuous earth wire of green colour on independent board.
76S&F switch piano flush type, 6 Amps, 230V AC, single pole, one way
77S&F socket out let multipurpose suitable for 2 pin and 3 pin 5/6 Amp type complete as directed
78S&F switch piano, flush type 15 Amps,230V, AC Single pole, one way, complete all as directed.
79S & F socket out let 2 in 1, multipurpose suitable for 2/3 pin 15 amp flush type.
80S & F bell push,flush type 5 Amp, 220 V, single pole.
81Supply & fixing ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body for surface type, 65mm x 50mm three terminal complete as directed.
82S&F angle type holder insulated body with back plate complete all as directed.
83Supply and fix in repairs Modular Switch flush type 10 Amps single pole, one waycomplete all as specified.
84Supply and fix in repairs Modular Socket outlet, multi purpose, 5 Pin combined 6 Amps flush typecomplete all as specified.
85Supply and fix in repairs Modular Bell push flush type, 10 Amps complete all as specified.
86Supply and fix in repairs Modular Socket outlet, multi purpose, 2/3 pin combined 16 Amps universal socketcomplete all as specified.
87Supply and fix in repairsModularSwitch 16 Amps single pole, one waycomplete all as specified.
88Supply & fix in repairsmodular fan regulator step type, 2 module type complete.
89Supply and fixing in repairs white finished single mounting modular plates suitable for modular accessories of following sizesas per specified and directed by Engr-in-charge.
90(a) Suitable for 1/2 modules
91(b)Suitable for 3 modules
92(c)Suitable for 4 modules
93(d)Suitable for 6 modules
94(e)Suitable for 8 horizontal modules
95(f)Sutable for 12 horizontal modules
96Supply and fix in repairssheet metal boxes concealed in wall suitable for housing modular accessories of following sizes as per specified and directed by Engr-in-charge.
97(a)Suitable for 1 or 2 modules 50mm.
98(b)Suitable for 3 modules 50mm.
99(c)Suitable for 4 modules 50mm.
100(d)Suitable for 6 modules 50mm.
101(e)Suitable for 8 modules 50mm.
102(f)Suitable for 12 horizontal modules 50mm
103Supply and fix LED inverter type bulb of 9 watt, Of base B-22 CDL, suitable for fixing in lamp holder.
104Supply and fix in repair Motor starter switch with overload protection 240 Volts, incl plug, socket, MCB SP 20 Amp single pole, suitable & safe for Air conditioners. Coolers, Waters pumps, refrigerators etc, Incl required size of suitable cover plate for fixing starter & sockets and making good of disturbed surfaces with existing colour complete all as specified and directed by Engr-in-Charge.
105Supply & fix in repairs and testing of Energy efficient 5 Star BEE rating, electric geyser of 25 liters capacity with Fiber/ ceramic body with puff insulation inner tank ceramic with all in built safety accessories like thermo start/ automatic thermal cut out with ON/OFF/Cut out indications all pre wired and additional safety accessories like pressure release valve, non return valve in same or other position as ordered with the help of suitable suitable size of nuts & bolts making necessary electrical connection incl taking down and safe deposit of old unserviceable Geyser to E/M Store complete all as directed by Engr-in-charge.
106Supply & fix electric wall fan of 400mm sweep, 230 Volts single phase, white in colour, complete with all accessories like nuts, bolts, clamps etc and connection from ceiling rose complete all as specified and directed by Engr-in-Charge.
107S&F (in building peripheri) energy efficient, compact street lighting 30 Watt LED with deep drawn Aluminium housing complete withconncting wire and provision of GI bracket, clamp, nuts, bolts grounded in wall incl all fixing arrangement complete as directed.
108S & F in repair of LED PL 18 W Lamp 4 PIN type (LED pin type 18 w lamp) suitable for Existing 2" x 2" ceiling light fittings of 2 x 36/ 3 x 36 wattage type complete as directed by Engr-in-Charge.
109Supply and fix in repairs LED batten suitable for single T8 LED tube upto 1 x 22 Watt, without LED tube rod, pre-wired for LED tube, complete with all accessories duly connection with three core flexible copper cable and duly fixed on two Nos PVC square boxes complete all as specified and directed.
110Supply and fix in repairs retrofit LED tube light T-8 type, 1 x 20 Watt, 6000K with extruded Al heat sink for efficient heat dissipation complete all as specified and directed.
111Supply and fix in repairs LED tube light fittings 1x9/10 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of pvc square boxes complete all as specified and directed.
112S&F for energy saving recess/ surface mounted luminaire 36/40/42W, high efficiency PMMA diffuser gives soft glare free light, suitable for 600 x 600 ceiling cut out, recess mounted 36W LED luminaire in MS housing (2" x 2") incl Provn of three core cable of copper conductor of size 1.5 sqmm, making necessary electric connetion from ceiling rose to fitting terminal, fixing the fitting on ceiling including cutting, grooving with proper finish and making good, disturbed surface with all fixing arrangement complete all as directed.
113S&F for energy efficient, Ultra Modern designLED luminiaire 36/40/42 W (1x4) withCRCA housing white power finish,which provides soft-light glare free symmetrical illumination suitable for Armstrong/ Grid ceiling/ surface application, incl provn of three core cable of copper conductor of size 1.0 sqmm, making necessary electric connection from celing rose to fitting terminal, fixing the fitting on ceiling including cutting, grooving with proper finish and making good, disturbed surface with all necessary fixing arrangment complete all as directed.
114Supply & fix LED Bulk Head luminaire 10W, 6000K pressure die cast housing with IP65 protection complete with electric connection & all necessary fixing arrangement as specified and directed by Engr-in-Charge.
115Supply & fix Recessed mounted LED panel slim, compact, aluminium die castedge lite panel of 15 W with premium diffuser to ensure glare free & even distribution of light complete with electric connection all as specified and directed by Engr-in-Charge.
116Supply & fix surface mounted round LED panel of 12W Al die cast body with premium diffuser to ensure glare free & even distribution of light complete with electric connection all as specified and directed by Engr-in-Charge.
117Supply and fix in repairs Wall light fittings suitable for & including LED bulb of 7 watt (B-22), including connection with all necessary fixing accessories complete all as specified and directed by Engr-in-Charge.
118Supply in repairs PVC rectangular blocks, for mounting,switch,sockets,fan regulator etc.with 3 mm thick plastic laminated sheet cover with closed recessed, designed and cutting module for fixing switches/ sockets of any rating as directed by Engr-in-charge for the following sizes:-
119(a)100mm x 100mm x 50mm deep
120(b)175 mm x 100mm x 50mm deep
121(c)200mm x 150mm x 50mm deep
122S&F hylum sheet Incl cuttings module suitable for fixing 5/15 Amps switch/socket /fan regulator/indicator etc. of following sizes:
123(a) 4" x 4"
124(b) 4" x 6"
125(c) 8" x 10"
126(d) 10" x 12"
127Supply in repairs/replacements of Self Adhesive PVC ElectricalInsulation tape of size 1.80 cm x 6.5 m x 0.125mm,
128S&F in replacement3 pin plug-top, 15A, 240, beckelite, heavy duty suitable for 16A socket outlet complete all as directed.
129S&F in replacement 3 pin plug-top, 5A, 240, beckelite, heavy duty suitable for 5A socket outlet complete all as directed.
130S&F in replacement LED-Driver suitable for LED ceiling light fittings 34/36 watt (2"x2") recess mounting type complete with electric connection at both ends (Input (a.c.) and output (d.c.) side), all as specified and directed by Engr-in-Charge. (Make : As per make of existingfaulty LED light at Site)
131S&F in replacement LED-Driver suitable for LED ceiling light fittings 40/42 watt (1"x4") recess mounting type complete with electric connection at both ends, (Input (a.c.) and output (d.c.) side), all as specified and directed by Engr-in-Charge. (Make : As per make of existing faulty LED light at Site)
132Supply & Fix in repairs/ replacement plastic body exhaust fan AC single phase 230/ 240 V of size 200mm sweep with louver, white in colour including duly connection with copper wire etc,incl taking down and old unserviceable exaust fan deposit to E/M Store complete all as specified and directed.
133Supply & Fix in repairs/ replacement plastic body exhaust fan AC single phase 230/ 240 V of size 250mm sweep with louver, white in colour including duly connection with copper wire etc,incl taking down and old unserviceable exaust fan deposit to E/M Store complete all as specified and directed.
134S & F for energy efficient exhaust fan havey duty of 225/300mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size ofhole to existing brick wall for fan base including writting the MES Number with synthetic enamel paint compelte all as specified and directed.Note :- Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted).
135S & F for energy efficient exhaust fan havey duty of 380mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size ofhole to existing brick wall for fan base including writting the MES Number with synthetic enamel paint compelte all as specified and directed. Note :- Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted).
136Supply and fixing electric ceiling fan 1200mm sweep, 5-star rating, 240 Volts single phase, connection with three core cable of copper conductor of size 1.5 sqmm from ceiling rose to fan terminal complete with remote all accessories complete etc all as specified and directed by Engr-in-Charge.
137Supply & Fix in replacement, electric bell, ding dong, AC, 220 V, single pole, complete as directed.
138Supply in replacement, electric buzzer, AC, 220 V, single pole, complete as directed.
139Supply in repairs Flexible PVC Conduit pipe suitable for cover/ laying electrical wiring etc. complete as directed.
140Supply & Fix in replacement, bettery for BLDC fan suitabe for exsiting remote control as per sample complete all as directed.
141Supply & Fix in replacement, of remote for BLDC fan suitabe for exsiting BLDC fanas per sample complete all as directed.
142Supply & laying or fixing 1100 volts grade duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape overall PVC sheathed cable size 4mm twin core flat/circular cable in.
143M&L for Sub main wiring in repairs with two runs of single core FRLSH PVC insulated unsheathed cable 1100 volts grade, 10.0 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm dia including one run of PVC insulated unsheathed 10.0 sqmm cable with multistranded copper conductor green PVC FRLSH insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wallall as specified and directed. Note:- Two runs of 10.00 sqmm cable, one run of 10.00 sqmm cable will be measured as one unit.
144M&L for Sub main wiring in repairs with two runs ofsingle core PVC FRLSH insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm dia including one run of PVC insulated unsheathed 6.0 sqmm cable with multistranded copper conductor green PVC FRLSH insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wallall as specified and directed. Note:- Two runs of 6.00 sqmm cable, one run of 6.00 sqmm cable will be measured as one unit.
145M&L for Sub main wiring in repairs with two runs ofsingle core FRLSH PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25 mm dia including one run of PVC FRLSH insulated unsheathed 4 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wall all as specified and directed. Note:- Two runs of 4.00 sqmm cable, one run of 4.00 sqmm cable will be measured as one unit.
146Supply and fixing GI pipe light grade 50 mm dia in short lengths, to walls/poles/pillers including cutting,chasing and fixing one endon walls/pillers/in ground for garden light fittings/gate light complete all as specified and directed.
147Supply and lay XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts grade ofsize 16 sq mm 4 core, cross sectional area lay trenches/ wall/ poles/ ducts/ pipes or through sleeve etc including connecting/ jointing with lugs and testing all as specified and directed by Engineer-in-Charge.
148Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in hard/ dense soil and getting out complete all as specified and directed by Engr-in-Charge.
149Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
150Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
151M&L for filling approved fine crusted sand in trenches as cable cushionto the full width of excavated trench, under and over cable complete all as specified and as directed. (Note : Punned thickness of sand shall be measured)
152M&L for bricks slightly over burnt (kiln burnt), modular bricks, best quality, locally available, laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection all as specified and as directed.
153M&L of earthing complete with GI steel earth plate electrode 60cm x 60cm x 6.0mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI strip 32 x 6mm by means of nuts, bolts checks nuts and washers made of GI earth wire protected by GI pipe 40mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 using 20mm graded aggregate, pre-cast RCC (1:2:4) type-B, over slab 30cm x 30cm x 10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 3 of MES schedule Part-I and testing after completion.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy