Tender For Renovation Up Gradation Of Ug Cable And Feeder Pillars Panel Of 127 Bn Now 140 Bn Bsf Satrana Under Shq Bsf Bikaner., Bikaner-Rajasthan

Border Security Force-BSF has published Tender For Renovation Up Gradation Of Ug Cable And Feeder Pillars Panel Of 127 Bn Now 140 Bn Bsf Satrana Under Shq Bsf Bikaner.. Submission Date for this Tender is 15-05-2024. Feeder Pillar Tenders in Bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

43327047
Tender For Renovation Up Gradation Of Ug Cable And Feeder Pillars Panel Of 127 Bn Now 140 Bn Bsf Satrana Under Shq Bsf Bikaner.
Open Tender
Indian
Rajasthan
Bikaner
15-05-2024

Tender Details

Renovation Up Gradation Of Ug Cable And Feeder Pillars Panel Of 127 Bn Now 140 Bn Bsf Satrana Under Shq Bsf Bikaner.

Key Value

Document Fees
Refer document
EMD
INR 40215.0 /-
Tender Value
INR 20.10 Lakhs /-

BOQ Items

Name of Work:
Sl. No. Item Description
1Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc.as required.(in item no-17) (i) 100 A, 30 KA,FP MCCB.
2(ii)125 A, 36 KA,FP MCCB
3(iii)200 A, 36 KA,FP MCCB
4(iv) 250 A, 36 KA,FP MCCB
5Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
6Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode includingconnection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
7Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
8Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.(i) 3.5X 120 sqmm(45 mm)
9(ii) 3.5X 150 sqmm(50mm)
10(iii) 3.5X 185 sqmm(57mm)
11(iv) 3½ X 240 sq. mm (62mm)
12Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering Above Above 95 sq. mm and upto 185 sq. mm
13Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (i) Above 95 sq. mm and upto 185 sq. mm
14Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required
15Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required. (i) above 95 sq. mm and upto 185 sq. mm
16(ii) Above 185 sq. mm and upto 400 sq. mm
17Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (i) above 95 sq. mm and upto 185 sq. mm
18(ii) Above 185 sq. mm and upto 400 sq. mm
19Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (i) 3.5 X 240 sq. mm
20Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. there must be proper connection cable or dwc pipe with junction box/panel.Sothat rainy water does not enter the pipe ,a cap/reducer should be fitted on the eadge of pipe propery.(i) 120 mm dia (OD-120 mm & ID-103 mm nominal)
21(ii) 160 mm dia (OD-160 mm & ID-135 mm nominal)
22Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required( Zenith/TATA/Jindal-hisar/Prakash- Surya make) (i) 150 mm dia nominal bore
23Laying of cable without cutting the road by making the provision through bokki or any other mean below up to the depth of 0.75 mtr etc as required
24SITCof cubical type out door joint box having size 600mm X 600 mm X 400 mm deep having doors on both side fabricated with 2.03 mm thick CRCA sheet mountedon 35 mm x 35 mm X5 mm angle iron frame having 600 mm long 04 nos leg stand erected in cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone 40 mm nominal size) foundation i/c excavation 30 cm below the ground. The leg paint with prime and black paint as required and consisting of following accessoris . 04 Nos aluminium bus bar strip suitable for 300 A current carrying capacity having size and strip suitable space for incoming and outgoing cable .( area of joint box is taken in sqmm face area.)
25Designing , Fabrication & SITC of various sizes water protected outdoor (Water proof)huttype compartmentalized type double door cubical panelboth side opening havingdepth up to 450 mmsuitable for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet with required hardware duly painted with powder coatedin an approved Siemens grey shade after 7 tank treatment processes,.Panel having separate detachable gland plate, end termination as per cable of size,angle iron base frame made out of 50mmx50mmx6 mm angle iron of suitable size of the feeder pillar (minimum height 60cm), hinged door, both side opening with locking arrangement, earth bar/stud, led pilot light for phase indicator (R,Y,B) on top, 400A/415V 4 strip aluminum bus bar duly PVC sleeved, connection inter–connection with 25% extra current carrying capacity busbars to MCCBs spreader links and with solid copper conductor cable 10 sqmm/ solid aluminium rodfor connection toMCBs and heavy duty connectors of required current carrying capacity to be fixed back side including incoming/Outgoing cables connection for three and single phaseMCBs where as required, testing on loadand marking of location for incoming and out going distribution i/c grouting the legs in existing floor with 1:3:6 cement concrete foundation and dismantling the existing panel, incoming/outgoing cable connections etc complete as required i/c dismantling the existing feeder pillar and UG cable. (Panel should beas per design &drawing approved by Engg in charge).LED light min 5 watt with on/off switch alongwith below said item to be provided in the panel. a) VAP Meter in each panel to be designb) LED Pilot light (22.5 MM dia) withprotection MCB’s-03Nos) The design of the outdoor feeder panel should got approved from Competent Technical authority before fabrication.(The Fp should be of size(1)1500 mm(height) x 2100 mm (width) x 450 mm deepappx)(2)1500 mm(height) x 2100 mm (width) x 450 mm deep appx(3) 1200 mm(height) x 1500 mm (width) x 450 mm deepappx(4) size 1200 mm(height) x 1500 mm (width) x 450 mm deep appx(5)1200 mm(height) x 1500 mm (width) x 450 mm deep appx(6)1200 mm(height) x 1500 mm (width) x 450 mm deepappx
26Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.(in item no-17) (i) 320 A, 50 KA,FP MCCB
27160 A, 36 KA,FP MCCB
28100 A, 65 KA,FP MCCB
29Add GST difference Multification factor (0.0633) on DSR Items No. 1 to 13
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail