Tender For Renovation Up Gradation Of Ug Cables And Feeder Pillar Panels Of Sector Campus Bsf Bikaner, bikaner-Rajasthan

Border Security Force-BSF has published Tender For Renovation Up Gradation Of Ug Cables And Feeder Pillar Panels Of Sector Campus Bsf Bikaner. Submission Date for this Tender is 15-05-2024. Feeder Pillar Tenders in bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

43327027
Tender For Renovation Up Gradation Of Ug Cables And Feeder Pillar Panels Of Sector Campus Bsf Bikaner
Open Tender
Indian
Rajasthan
bikaner
15-05-2024

Tender Details

Renovation Up Gradation Of Ug Cables And Feeder Pillar Panels Of Sector Campus Bsf Bikaner

Key Value

Document Fees
Refer document
EMD
INR 91101.0 /-
Tender Value
INR 45.55 Lakhs /-

BOQ Items

Name of Work: < Renovation/Up -gradation of UG Cablesand feeder pillar/panelsofsector campus BSF Bikaner. >
Sl. No. Item Description
1Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode includingconnection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
3Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
4Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
53.5X 35 sqmm(32mm)
63.5X 70 sqmm(38mm)
73.5X 95 sqmm(45mm)
83.5X 120 sqmm(45 mm)
93.5X 150 sqmm(50 mm)
103.5X 185 sqmm(57mm)
113½ X 240 sq. mm (62mm)
12Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
13Upto 35 sq. mm
14Above 35 sq. mm and upto 95 sq. mm
15Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering
16Upto 35 sq. mm
17Above 95 sq. mm and upto 185 sq. mm
18Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required
19Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 120 sqmm
20Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required( Zenith/TATA/Jindal-hisar/Prakash- Surya make) (i) 150 mm dia nominal bore
21Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
2290 mm dia (OD-90 mm & ID-76 mm nominal)
23120 mm dia (OD-120 mm & ID-103 mm nominal)
24Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
25120 mm dia (OD-120 mm & ID-103 mm nominal)
26160 mm dia (OD-160 mm & ID-135 mm nominal)
27Laying of one numberPVC sheathed and PVC sheathed/XLPEpower cable of 1.1 kV grade , of following size in the existing HDPE/RCC/ HUME/ METAL pipe as required.
28Upto 35 sq. mm
29Above 35 sq. mm and upto 95 sq. mm
30Above 95 sq. mm and upto 185 sq. mm
31Above 185 sq. mm and upto 400 sq. mm
32Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct / along pole / loose for connections etc as required .
33Upto 35 sq. mm
34Above 35 sq. mm and upto 95 sq. mm
35Above 95 sq. mm and upto 185 sq. mm
36Above 185 sq. mm and upto 400 sq. mm
37S/I/T/C of cubical type out door joint box having size 600 mmx 600 mmx 400 mm deep having doors on both sidefabricated with 2.03 mm thick CRCA sheet mounted on 35 mm x 35 mm x 5 mm angle iron frame, having 600 mm long 04 nos leg stand erected in cement concrete 1 :3 :6 (1 cement :3 coarse sand : 6 graded stone 40 mm nominal size) foundation i/c excavation 30 Cm below the ground. The legs paint with primer and black paint as required and consisting of following accessories. 04 nos aluminium bus bar strip suitable for 300 Amp current carrying capacityhaving size and also suitable space for Incoming and outgoing cable.(area of Joint box is taken in sq mm face area)
38Providing and fixing following capacity 4 pole, 415 V, category AC-23A. On Load Change Over Switch,in open execution in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. ( Make:-L& T /Socomec / Legrand /ABB /Schneider/ Siemen)
39250 A, four Pole.
40400 A, four Pole.
41Desigining,Fabrication Supply/ installation/ testing and commissioning of indoor type compartmentalized cubical panel of size suitable for 415 Volt, 3 phases, 50 Hz made out of 2.03mm thick CRCA sheet and depth up to 800 mm with required hardware duly painted with powder coated in an approved Siemens grey shade after 7 tank treatment processes. The panel having separate detachable gland plate, hinged door, with locking arrangement, earth bar/stud, 1000A/415V 4 strip aluminum bus bar duly PVC sleeved, including electrical mechanical interlocking, connection inter–connection for incoming/Outgoing cables with the required current capacity bus bar links (as per direction of Engg in charge), space for 800A 4 Pole Air Circuit Breakers, bus couplers for two transformers, MCCBs. The panel should be mounted on MS Base frame 75 mm x 40 mm x 5mm of suitable size and should have the provision of following instruments mounted and includingprovision of outgoing cable connections bus bar links of required current carrying capacity etc as required. (Indoor Panel should be as per design &drawing approved by Engg in charge and comprising of Instruments):- a) 0-500 Volts, Digital voltmeter of size 96 Sqmmx96 sqmm with Selector switch-02 Set b) 0-1000 Amps, Digital Ammeter of size 96Sqmmx96sqmm type with Selector switch -02 set c) LED Pilot light (22.5 MM dia) withprotection MCB’s-06Nos) d) Alarm System - 01 Nos e) Exhaust Fan for panel - 01Nos.(The Main LT Panel-1 should be ofsize-4000 x 1800 x 800 mm approx.)
42Providing and fixing of 800A, Air circuit breaker breaking capacity 50 KA manual draw out type 4 Pole Microprocessor based ET trip systems with thermal memory Conforms to IS/ IEC 60947-2 & 3,Zone Selective Interlocking, Fully rated neutral with inbuilt protection, Pre trip alarm & individual fault indicating LEDs ACB/Bus bar coupler MVS08N3MW6L comprising of Overload, Short-circuit, Instantaneous & Earth-fault protectionsin the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying capacity etc as required as per direction of Engg in charge(In item No 16)-Schneider/L&T/ABB/legrand
43Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 16) 400 A 36 KA FP MCCBIcs= 100% of Icu
44Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 16)250A FP 25 KA MCCB Ics= 100% of Icu
45Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 16)125 A FP MCCB 25 KAIcs= 100% of Icu
46Providing and fixing of tape wound current transformer 1000/5 in the existing panel i/c connections with 1.5 sqmm pvc copper wirein the existing panel at SN 3 (AE/L&T/Scheinder make)
47Providing and fixing Extended Rotary handle for 400 Amp FP MCCB in above existing cubicle panel board including making connections and teting etc,. as required.
48Providing and fixing Extended Rotary handle for 250 Amp FP MCCB inabove existing cubicle panel board including making connections and teting etc,. as required.
49Providing and fixing Extended Rotary handle for 125 Amp FP MCCB inabove existing cubicle panel board including making connections and teting etc, as required.
50Desigining,Fabrication Supply/ installation/ testing and commissioning of indoor type compartmentalized Essential cubical panel of size suitable for 415 Volt, 3 phases, 50 Hz made out of 2.03 mm thick CRCA sheet and depth up to 450 mm with required hardware duly painted with powder coated in an approved Siemens grey shade after 7 tank treatment processes. The panel having separate detachable gland plate, hinged door, with locking arrangement, earth bar/stud, 400 A/415V 4 strip aluminum bus bar duly PVC sleeved, including electrical mechanical interlocking, connection inter–connection for incoming/Outgoing cables with the required current capacity bus bar links (as per direction of Engg in charge), space forMCCBs and change over. The panel should be mounted on MS Base frame 75 mm x 40 mm x 5mm of suitable size and should have the provision of following instruments mounted and includingprovision of outgoing cable connections bus bar links of required current carrying capacityetc as required. (Indoor Panel should be as per design &drawing approved by Engg in charge and comprising of) Instruments Panel ) a) 0-500 Volts, Digital voltmeter of size 96 Sqmmx96 sqmm with Selector switch-01 Set b) 0-800 Amps, Digital Ammeter of size 96Sqmmx96sqmm type with Selector switch -01 set c) LED Pilot light (22.5 MM dia) withprotection MCB’s-03Nos) d) Alarm System - 01 Nos e) Exhaust Fan for panel - 01Nos. (TheEssential LT Panel should be ofsize-2300x 2000 x 800 mm Approx)
51Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 25)250A FP 25 KA MCCBIcs= 100% of Icu
52Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 25)125 A FP MCCB 25 KAIcs= 100% of Icu
53Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB /legrand(In item No 25)100 A FP MCCB 25 KAIcs= 100% of Icu
54Providing and fixing Extended Rotary handle for 250 Amp FP MCCB in above existing cubicle panel board including making connections and teting etc as required.
55Providing and fixing Extended Rotary handle for 125 Amp FP MCCB in above existing cubicle panel board including making connections and teting etc as required.
56Providing and fixing Extended Rotary handle for 100 Amp FP MCCB in above existing cubicle panel board including making connections and teting etc,. as required.
57Desigining,Fabrication Supply/ installation/ testing and commissioning of indoor type compartmentalized cubical panel of size suitable for 415 Volt, 3 phases, 50 Hz made out of 2.03mm thick CRCA sheet and depth up to 450 mm with required hardware duly painted with powder coated in an approved Siemens grey shade after 7 tank treatment processes. The panel having separate detachable gland plate, hinged door, with locking arrangement, earth bar/stud, 600 A/415V 4 strip aluminum bus bar duly PVC sleeved, including electrical mechanical interlocking, connection inter–connection for incoming/Outgoing cables with the required current capacity bus bar links (as per direction of Engg in charge), space forMCCBs and change over. The panel should be mounted on MS Base frame 75 mm x 40 mm x 5mm of suitable size and should have the provision of following instruments mounted and includingprovision of outgoing cable connections bus bar links of required current carrying capacityetc as required. (Indoor Panel should be as per design &drawing approved by Engg in charge and comprising of) Instruments Panel ) a) 0-500 Volts, Digital voltmeter of size 96 Sqmmx96 sqmm with Selector switch-01 Set b) 0-800 Amps, Digital Ammeter of size 96Sqmmx96sqmm type with Selector switch -01 set c) LED Pilot light (22.5 MM dia) withprotection MCB’s-03Nos) d) Alarm System - 01 Nos e) Exhaust Fan for panel - 01Nos.The LT Panel-2 should be of size-3200 x 1800 x 800 mm (approximate)
58Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 32)400 A 36 KA FP MCCBIcs= 100% of Icu
59Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 32)250A FP 25 KA MCCBIcs= 100% of Icu
60Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 32)125 A FP MCCB 25 KA Ics= 100% of Icu
61Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 32)100 A FP MCCB 25 KAIcs= 100% of Icu
62Providing and fixing Extended Rotary handle for 400 Amp FP MCCB in existing cubicle panel board including making connections and teting etc,. as required.
63Providing and fixing Extended Rotary handle for 250 Amp FP MCCB in above existing cubicle panel board including making connections and teting etc,. as required.
64Providing and fixing Extended Rotary handle for 125 Amp FP MCCB in above existing cubicle panel board including making connections and teting etc,. as required.
65Providing and fixing Extended Rotary handle for 100 Amp FP MCCB in above existing cubicle panel board including making connections and teting etc,. as required.
66Designing , Fabrication & SITC of various sizes water protected outdoor (Water proof)huttype compartmentalized type double door cubical panelboth side opening havingdepth up to 450 mmsuitable for 415 Volt, 3 phases, 50 Hz made out of 2.03mm thick CRCA sheet with required hardware duly painted with powder coatedin an approved Siemens grey shade after 7 tank treatment processes,.Panel having separate detachable gland plate, end termination as per cable of size,angle iron base frame made out of 50mmx50mmx6 mm angle iron of suitable size of the feeder pillar (minimum height 60cm), hinged door, both side opening with locking arrangement, earth bar/stud, led pilot light for phase indicator (R,Y,B) on top, 400A/415V 4 strip aluminum bus bar duly PVC sleeved, connection inter–connection with 25% extra current carrying capacity busbars to MCCBs spreader links and with solid copper conductor cable 10 sqmm/ solid aluminium rodfor connection toMCBs and heavy duty connectors of required current carrying capacity to be fixed back side including incoming/Outgoing cables connection for three and single phaseMCBs where as required, testing on loadand marking of location for incoming and out going distribution i/c grouting the legs in existing floor with 1:3:6 cement concrete foundation and dismantling the existing panel, incoming/outgoing cable connections etc complete as required i/c dismantling the existing feeder pillar and UG cable. (Panel should beas per design &drawing approved by Engg in charge).LED light min 5 watt with on/off switch alongwith below said item to be provided in the panel. a) VAP Meter in each panel to be designb) LED Pilot light (22.5 MM dia) withprotection MCB’s-03Nos) The design of the outdoor feeder panel should got approved from Competent Technical authority before fabrication.(The Fp should be of size(1)1050 mmx 1000 mmx 450 mm deepappx)(2)1050 mmx 1000 mmx 450 mm deep appx(3) 1050 mmx 1000 mmx 450 mm deepappx(4) size 1050 mmx 1000 mmx 450 mm deep appx(5)1050 mm x 1000 mm x 450 mm deep appx
67Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 41)320 A 36 KA FP MCCBIcs= 100% of Icu
68Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 41)160A FP 25 KA MCCBIcs= 100% of Icu
69Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 41)125 A FP MCCB 25 KA Ics= 100% of Icu
70Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 41)100 A FP MCCB 25 KAIcs= 100% of Icu
71Providing and fixing following rating and breaking capacity and pole MCCB with Thermal magnetic release with adjustable overload, and short circuitand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Schneider/L&T/ABB/legrand (In item No 41)63 A FP MCCB 25 KAIcs= 100% of Icu
72Supplying installation testing & commissionig of CO2 type fire extinguisher ISI marked confirming to IS :15683 Capacity 4.5 Kg complete with delivery hose horn ,squeeze grip/wheel type release valve ,locking arrangment ,pressure gauge,operation manual and bracket .operating temperature-30C to 55 C with wall mounting bracket on surface/wall with dash fasteners etc as required.
73Supplying installation testing & commissionig of powder fire extinguisher(Stored pressure type) Capacity 6 Kg duly ISI marked confirming to IS :15683:2006 with IS 14609,ISI Marked ABC powder complete ,squeeze grip release valve ,discharge pipe ,locking arrangment ,pressure gauge,operation manual and bracket .operating temperature-10C to 55 C with wall mounting bracket on surface/wall with dash fasteners etc as required.
74Providing of set of 4 Nos 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red oxide paint and written with white paint "FIRE" and mounted on MS angle iron frame with bracket of appropriate size & capacity i/c filling sand etc.
75Providing of rubber mat 1 mtr wide and 12 mm thick to withstand 15 kv dielectric strength as per IS 5424:1969
76Dismentling and buyback credit for following existing old items i/c disconnection from existing cables /busbars/wires etc as required.)indoor LT Panels including aluminium busbar etc
77Add GST difference Multification factor (0.0633) on DSR Items onRs. 1765850