Tender For Annual Maintenance Contract Work For Air Conditioners, Cold Rooms, Refrigerators, Deep Freezers Etc 2024-25, niist-Kerala

Council Of Scientific And Industrial Research-CSIR has published Tender For Annual Maintenance Contract Work For Air Conditioners, Cold Rooms, Refrigerators, Deep Freezers Etc 2024-25. Submission Date for this Tender is 14-05-2024. Air Conditioner Tenders in niist Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

43320838
Tender For Annual Maintenance Contract Work For Air Conditioners, Cold Rooms, Refrigerators, Deep Freezers Etc 2024-25
Open Tender
Indian
Kerala
niist
14-05-2024

Tender Details

Annual Maintenance Contract Work For Air Conditioners, Cold Rooms, Refrigerators, Deep Freezers Etc 2024-25

Key Value

Document Fees
INR 590 /-
EMD
INR 32750.0 /-
Tender Value
INR 16.37 Lakhs /-

BOQ Items

Name of Work: Annual Maintenance Contract works for Airconditioners,Cold rooms,Refrigerators,Deepfreezers etc 2024-2025
Sl. No. Item Description
1PART-A Maintenance of Airconditioners
2Four Quartely servicing and maintenance of window mounting units 1.5 Tr/2 TR capacity of various makes like, Voltas, Bluestar, Videocon, Usha etc. Attend to all breakdown calls or performance related complainte. Rate should be quoted for yearly basis.
3Four Quartely servicing and maintenance of Split Air conditionersof1.5 Tr/2 TR capacity of various makes like, Voltas, Bluestar, carrier, Videocon, Usha etc. Attend to all breakdown calls or performance related complainte. Rate should be quoted for yearly basis.
4Four Quartely servicing and maintenance of Multi Split Air conditionersof2 Tr/ 3 TR capacity of various makes like, Voltas, Bluestar, carrier, Videocon, Usha etc. Attend to all breakdown calls or performance related complainte. Rate should be quoted for yearly basis.
5Four Quartely servicing and maintenance of cassette typeSplit Air conditionersof1Tr/2 Tr capacity of various makes like, Voltas, Bluestar, carrier, Videocon, Usha etc. Attend to all breakdown calls or performance related complainte. Rate should be quoted for yearly basis.
6Four Quartely servicing and maintenance of Slim line Air conditionersof 3/4 TR capacity of Voltas, make . Attend to all breakdown calls or performance related complainte. Rate should be quoted for yearly basis.
7Four Quartely servicing and maintenance of Ductable Split Air conditionersof various capacities as follows . Attend to all breakdown calls or performance related complainte. Rate should be quoted for yearly basis.
83 TR Carrier make
95 TR Carrier make
105.5TR Carrier,Blue star, Hitachi make
118.5TR Carrier,Blue starmake
12Four Quartely servicing and maintenance of PackagedAir conditionersof various capacities as follows . Attend to all breakdown calls or performance related complainte. Rate should be quoted for yearly basis.
1311 TR ETA/Zeco/Carriermake (Twin circuit of 5.5 TR with Horizontal AHU type)
1416.6 TR ETA make (Twin circuit of 8.5 TR with Horizontal AHU type)
15Four Quartely sevicing and maintenance of Cold Room 1.0/2 TR
16PART-BSupply, Installation,Replacing of Spares/Works as and when required basis - Part B-1For Window & Split Acs
17Supply and installation of new sealed unitcompressors for window mounting/Split/Multi split air conditioners of 1.5 TR/2TR of Reciprocating/Rotary as and when/which required
18Gas (Refrigerant R22/R32/410A) charging of 1.5 TR/2TR windows mounting air conditioners of various makes after welding , system flushing with nitrogen, leak testing, evacuation including all material cost and labour charges etc. complete , as when required.
19Gas (Refrigerant - R22/R32/R410a) charging of 1.5TR/2TR Split air conditioners of various makes after welding , system flushing with nitrogen, leak testing, evacuation including all material cost and labour charges etc. complete as and when required.
20Gas (Refrigerant - R22/R32/R410a) charging of 1TR/2TRcassette type Split air conditioners of various makes after welding , system flushing with nitrogen, leak testing, evacuation including all material cost and labour charges etc. complete as and when required.
21Gas (Refrigerent ) charging of 3 and 4 TR Slim line air conditioners after welding, system flushing with nitrogen, leak testing, evacuation including all matetrial cost and labour charges etc. complete asand when required.
22Shifting and Re-installation of spli/Multi split Air conditioners with in the Lab.Rooms/Camplus including Civil work if required.
23Copper tubing for the above1/4"" & 1/2"" ( or which ever is suitable size to the unit ) with insulation etc complete.
24supply & replacing of Condensing Unit Stand
25Condenser Fan motor Rewinding, over-hauling , bush replacement and re fixing etc. complete of window units/split Units, as and when required.
26Blower Fan motor bush repalcement , servicing and re-fixing etc for split units, as and when required.
27Sevicing and rectification of cordless remote controller PCBs of split Ac as and when required.
28Supply , fixing & commissioning of new condensing fan motor for split AC as and when required.
29Supply, fixing & commissioning of new blower fan motor for split AC as and when required.
30Supply , Installation & commissioning of New condensing units with copper coil without compressor of 1.5/2TR as and when required.
31Supply , Installation & commissioning of New Indoor units with copper coilof 1.5/2TR as and when required.
32Supply & Installation of New condenser copper coils 1.5/2TR split units (replacing of Aluminium Coil) as and when required.
33Replaccing/Repairing/fabricationg of sheet metalsof Bottom plate and fan mounting platesof condensing units, including painting of the same
34Supply and fixing of angle Ironfabricated condenser unit stand as per site condition /Engineer Incharge choice
35Supply and laying of closed cell nitrile rubber Insulation for existing refrigent tubes and wrapping heat resistance (white) tape on it.
36Supply and fixing of spare parts for windows units and split units, as and when required.
37Fan motor capacitor
38Starting capacitor
39Running Capacitor
40Starting Relay
41Thermostat
42Swing motor for split Acs
43Air filter Fiber
44Air Filter Fiber for spli Unit
45condenser fan leaf
46Blower Fan
47Replacement of remote control unit (cordless ) with signal receiver
48Contactor for 2TR single phase compressor
49Contactor for multi split A/Cs condenser fan
50Temp Sensor Air
51Temp Sensor coil
52PART-BSupply, Installation,Replacing of Spares/Works as and when required basis - PART - B-II For Ductable units 3,5,5.5 & 8.5 TR units
53Supply and fixing of the following Genuine spare parts whenever necessary
54Contactor for compressor
55Single Phase Preventer with Under Voltage & Over voltage cut out, Phase failure and phase reversal cut out
56Microprocesor based Controlling unit
57Temp sensor For Microprocessor
58Compressor for 3TR (1.5 + 1.5) unit 1.5TR Rotary Compressor
59Liquid line filter / Drier
60Condenser fan Leaf
61V belts for IDUs
62Blower Fan motor Rewinding , over hauling , and Refixing etc complete whenever required.
63Condenser fan motor Rewinding, over-hauling, and refixing etc complete as and when required
64Gas ( Refrigerant ) charging of 3TR air conditioners of Carrier make after welding , system flushing with nitrogen , leak testing , evacuation & recommissioning, including all material cost and labour charges etc. complete, as and when required. Twin system and hence rate may be quoted for 1.5
65Gas(Refrigerant) charging of 5.5TR air conditioners of carrier/Blue star make after welding,system flushing with nitrogen, leak testing , evacuation & recommissioning , including all material cost and labour charges etc. complete, as and when required.
66Gas (Refrigerant) charging of 8.5 TR/8.3TRair conditioners of variousof Carrier/Blue starafter welding , system flushing with nitrogen, leak testing, evacuation including all material cost and labour charges etc. complete , as when required.
67Supply and fixing of the following Genuine spare parts whenever necessary
6860x30.5x50 cm Box type prefilter for ZECO AHU 90% down to 10 Micron
6961x61x50 cm Box type prefilter for ZECO AHU 90% down to 10 Micron
7061x61x50 cm Box type prefilter for ZECO AHU 99% down to 5 Micron
7160x30.5x50 cm Box type prefilter for ZECO AHU 90% down to 5 Micron
72Supply & replacing of Condenser deck (Condenser mounting plate) for carrier make 3TR units
73PART-BSupply, Installation,Replacing of Spares/Works as and when required basis- PART - B-III For Packaged/AHU type units
74Supply and fixing of the following spare parts (original) whenever necessary
75contactor for compressor (siemens 3TF33)
76contactor for blower motor (siemens 3TF31)
77Overload relay for compressor (siemens 3UA52 16-25A)
78Overload relay for fan motor(siemens 3UA506-10A)
79Under Voltage & over voltage cut out and phase failure and phase reversal cut put ( Make -Minilec - S2VMR3)
80Microprocesor based Controlling unit carrier /ETA makes
81Temp sensor For Microprocessor
82"v" Belts
83Bearings for Blower mounting
84Shaft for blower
85Liquid line filter/drier
86AHU Fan motor Rewinding , over-hauling , and Re-fixing atc complete as and when required.(5 HP, 3HP motor)
87Condenser fan motor Rewinding, over-hauling, and refixing etc complete as and when required
88Gas (Refrigerant ) charging of 11TR (5.5 Twin Compressors with individual Ref Circuit ) air conditioners . After welding, syystem flushing with nitrogen , leak testing , evacuation & recommissioning , including all material cost and labour charges etc. complete , as and when required.Twin system and hence rate may be quoted for 5.5 TR only .
89Gas (Refrigerant ) charging of 16TR (8.3 Twin Compressors with individual Ref Circuit ) air conditioners . After welding, syystem flushing with nitrogen , leak testing , evacuation & recommissioning , including all material cost and labour charges etc. complete , as and when required.Twin system and hence rate may be quoted for 8.3 TR only .
90Fabrication & Installation of Standard Electrical Controll pannel for 16.6 Tr Twin circuit Horizontal AHU roof top Packaged Unit with minimum Size of 700 mm X 450 mm x200 mm includingL & T FN 100A Main Switch, 415V .(The drawing of the pannel should be approved by Eng Incharge before Fabrication)
91Removingold Controller pannel &Installation of New supplied panneand byUtilizing the components such as ControllerContactor, relays, including termination Glands etc complete
92Supply &Replacing ofdouble skin insulated Bottompannel of 50 mmthick forETA make AHU=CTA-008 (16.6TR Horizontal Mount ) it includes system disconnection after proper pumpdown /reconnection of the same and Duct mouths etc complete if necessary
93Replaccing/Repairing/fabricationg of sheet metalsof Bottom plate and fan mounting platesof condensing units of 5.5 TR Units, including paintingetc complete
94PART-BSupply, Installation,Replacing of Spares/Works as and when required basis- PART - B-IV For Cold Rooms
95Four Quartely servicing and maintenance of cold rooms 1.5 TR/ 2TR capacity (4 Deg C) of makes like Voltas, Carrier, L.G., Bluestar, Videcon, Usha etc. Attend to all breakdown calls or performance related complaints. Rate should be quoted for yearlybasis.
96Replacement of Evaporator fan motor with leafs
97Replacement of Condenser fan motor with leafs
98Gas (Refrigerent) charging of 1.5TR/2TR cold rooms flushing with Nitrogen , leak testing , evacuation including all material cost and labour charges etc. complete, as and when required.
99PART-BSupply, Installation,Replacing of Spares/Works as and when required basis- PART - B-V For Refrigerators/DeepFreezers etc
100Exchanging defective compressors with new one, installation , welding , leak testing, evacuation and gas charging, etc. complete for all models, as and when required.
101Cost of refrigerent, welding, ;abour charge , etc. complete for gas charging after evacuation of the system of all models, as and when required.
102Spare parts ( original ) supply and replacement , as and when required.
103Relay
104Thermostat
105Bulb
106OLP
107Capacitors
108Timer for non frost refrigerator
109Heater for non frost refrigerator
110Fan motor with fan leaf for Frost free Refrigerator
111Supply & installation of compressors of various capacity refrigerator , as and when required.
112Gas charging after testing and evacuation including cost of materials and labour charges, etc. complete, as and when required.
113Service Taxes If any
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail