Tender For Repair Maintenance Of Street Light High Mast Lights Junction Boxes And Connected Works Of Otm Accommodation And Various Office Area At Faridkot Mil Stn, faridkot-Punjab

Military Engineer Services-MES has published Tender For Repair Maintenance Of Street Light High Mast Lights Junction Boxes And Connected Works Of Otm Accommodation And Various Office Area At Faridkot Mil Stn. Submission Date for this Tender is 05-06-2024. Distribution Box Tenders in faridkot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43320660
Corrigendum : Tender For Repair Maintenance Of Street Light High Mast Lights Junction Boxes And Connected Works Of Otm Accommodation And Various Office Area At Faridkot Mil Stn
Open Tender
Indian
Punjab
faridkot
05-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair Maintenance Of Street Light High Mast Lights Junction Boxes And Connected Works Of Otm Accommodation And Various Office Area At Faridkot Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-06-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

Attachment

FileName File Description File Size
b1a5dcf0-c6f2-4fed-83b2-914e2abd9633.html Tender Notice 0 KB
BOQ_730609.xls Tender Document 0 KB
Tenderdocuments15.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: Repair/Maint of street light, high mast lights, junction boxes& connected works of OTM accn and various office area at Faridkot Mil Stn
Sl. No. Item Description
1Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting outincluding trimming the sides and forming bottom surfaces to required levels in soft/loose soilcomplete all as specified and directed.
2Returning, filling in, including spreading, levelling,watering and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed .
3Removal of surplus excavated soil to a distance not exceeding50metre and depositing where directed at a level not exceeding1.5 metre above the starting point,complete all as specified and directed.
4M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
5Supplying and laying,factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dryin trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
6Material & labour, for cutting existing road for taking out/laying of underground cable through GI pipe of dia 40mm including necessary earth work and making good to match with the existing surface with PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates complete all as specified and directed
7Supply and laying / fixing , GI pipe, light grade, 40mm dia bore for cable protection fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement, including taking out old unserviceable pipe complete all as specified and directed. Note: (i) Excavation and earth work shall be measured and paid separately.
8Supply, laying, jointing and testingof Low Tension (LT)XLPEinsulated,armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, complete including taking out old cable & bricks all as specified and as directed. Note:(i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
9All as per Ser item No 08 here-in-before but LT cable of cross sectional area16 Sqmm, 4 core all as specified and directed .
10All as per Ser item No 08 here-in-before but LT cable of cross sectional area10 Sqmm, 2 core all as specified and directed .
11S&F in replacement 1100 volts grade, heavy duty cable with PVC insulated,stranded aluminium conductor served with an inner sheathing of PVC tape armourmedwith galvanised steel wire or tape and overall PVC sheathed ,2 core, 10 sqmm nomonal cross section in service connectionscomplete all as specified and directed
12S&F in replacement 1100 volts grade, heavy duty cable with PVC insulated,stranded aluminium conductor served with an inner sheathing of PVC tape armourmedwith galvanised steel wire or tape and overall PVC sheathed ,2 core, 6 sqmm nomonal cross section in service connectionscomplete all as specified and directed
13Supply, fixing and testing aesthetically designed LED street light luminiareis of 30 Watts system wattage for energy saving having IP 65 degree of protection,with minimum system efficiency as>85%,made ofpressure die casting aluminium housing, power coated in graphite grey andheat resistant toughened glass with excellent thermal management and prismatic polycarbonate covers for ensuring efficient optics and uniform distribution of light fitting should have operating voltage range of 150-270 VAC,THD<20%,P.F>.95 and fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K including taking down of old unserviceable street light fittings any type complete all as specified and directed.
14Supply, fixing and testing aesthetically designed LED street light luminiareis of 45 Watts system wattage for energy saving having IP 65 degree of protection,with minimum system efficiency as>85%,made ofpressure die casting aluminium housing, power coated in graphite grey andheat resistant toughened glass with excellent thermal management and prismatic polycarbonate covers for ensuring efficient optics and uniform distribution of light fitting should have operating voltage range of 150-270 VAC,THD<20%,P.F>.95 and fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K including taking down of old unserviceable street light fittings any type complete all as specified and directed.
15Supply, fixing and testing aesthetically designed LED street light luminiareis of 60 Watts system wattage for energy saving having IP 65 degree of protection,with minimum system efficiency as>85%,made ofpressure die casting aluminium housing, power coated in graphite grey andheat resistant toughened glass with excellent thermal management and prismatic polycarbonate covers for ensuring efficient optics and uniform distribution of light fitting should have operating voltage range of 150-270 VAC,THD<20%,P.F>.95 and fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K including taking down of old unserviceable street light fittings any type complete all as specified and directed.
16Supply, fixing and testing LED flood light luminiareis of 80 Watts system wattage for energy saving having IP 65/66 degree of protection,with minimum system efficiency as>85%,made ofpressure die casting aluminum housing power coated in graphite grey andheat resistant toughened glass with excellent thermal management and prismatic polycarbonate covers for ensuring efficient optics and uniform distribution of light fitting should have operating voltage range of 150-270 VAC,THD<20%,P.F>.95 and fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K including taking down of old unserviceable flood light fittings any type complete all as specified and directed.
17Supply, fixing and testing LED flood light luminiareis of 160 Watts system wattage for energy saving having IP 65/66 degree of protection,with minimum system efficiency as>85%,made ofpressure die casting aluminum housing power coated in graphite grey andheat resistant toughened glass with excellent thermal management and prismatic polycarbonate covers for ensuring efficient optics and uniform distribution of light fitting should have operating voltage range of 150-270 VAC,THD<20%,P.F>.95 and fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K including taking down of old unserviceable flood light fittings any type complete all as specified and directed.
18Supply and fixing in replacementsurge protection device (SPD) suitable for 45 watt LED street light complete all as specified and directed .
19Supply and fixing in replacementdriver suitable for 30 to 60 watt LED street light complete all as specified and directed .
20Supply and fixing in replacement of driver suitable for 80 watt LED flood light complete all as specified and directed
21Supply and fixing in replacement of surge protection device (SPD) suitable for 160 watt LED street light complete all as specified and directed .
22Supply and fixing in replacement of driver suitable for 160 watt LED street light complete all as specified and directed .
23Supply & fixing street light bracket fabricated out of GI tubing, light grade, 40mm bore, bend to the shape as directed and of length 1.0 mtr complete with mounting MS clamp made of flat iron 45 x 5 mm of suitable length (04 pairs) including nuts, bolts etc of suitable size complete all as specified and directed .
24Supply & fixing in replacement automatic street light switch using infrared sensor basedfor single phase & three phase complete all as specified and directed .
25Supply & fixing in replacement power contactor, 25 to 32 Amps, for Single phase automatic street light timercomplete all as specified and directed .
26Supply & fixing in replacement power contactor32 to 40 Amps,for three phase automatic street light timer completeall as specified and directed .
27Supply & fixing in replacement PVC insulated, multi stranded aluminium conductor, PVC sheathed cable,4 sqmm 2 core and making connection of street light fittings with overhead lines/ UG cable complete all as specified and directed .
28Supply and fixing Junction box of size 250 x 200 x 100 mm, out door type, IP65, made out of polycarbonate with glass fiber reinforced, suitable for 3 phase, 415 volts,pole mounting consisting of aluminium bus bar strip 15cm x 3mm, 4 Nos fixed on porcelain or epoxy terminal / insulators andprovision for incoming/outgoing cables with gromets including in built 6 Amp MCB, SP, 10KA complete all as specified and directed .
29Supply and fix in replacement single phase of 5 KW of automatic street light switch using Infrared Sensor based NATURAL SWITCH for automatic switching of street lights. nature switch operation should be based on Natural Light Lux level, required illumiance level for switching ON is = 30 Lux and for switching off = 10 Lux. The sensor should have part night operation facility of min 4 hrs to max 12 hrs. The sensor along with suitable power contactor of 32 to 40 Amps current rating, incomming MCB SPN and outgoing MCBs of 32-40 Amps and auto- manual (sensor By pass), the size of circuit should be multistranded FRLS min size of 6 Sqmm, selection operation should be enclosed in a pole/wall mounted enclosure made of rust proof, electric shock proof termite proof and FR grade special mounting compound conforming to IP 54 complete all as specified and directed .
30Supply and fix in replacement three phase of 5KW of automatic street light switch using Infrared red Sensor based NATURAL SWITCH for automatic switching of street lights. nature switch operation should be based on Natural Light Lux level, required illumiance level for switching ON is = 30 Lux and for switching off = 10 Lux. The sensor should have part night operation facility of min 4 hrs to max 12 hrs. The sensor along with 03 Nos suitable contactor eachof 32 to 40 Amps current rating.incomming MCB TPN and outgoing TPN MCBs of 32-40 Ampsand auto- manual (sensor By pass), size of circuit should be multistranded FRLS min size of 6 Sqmm, selection operation should be enclosed in a pole/wall mounted enclosure made of rust proof, electric shock proof termite proof and FR grade special mounting compoundconforming to IP 54 complete all as specified and directed .
31S&F in replacement MCB, TPN 40 Amp, 415 volts complete all as specified and directed .
32S&F in replacement MCB, TPN 63 Amp, 415 volts complete all as specified and directed .
33S&F in replacement LED post top lantern 25 watt, with die cast aluminium spigot,spun aluminium powder coated top cover and clear acrylic diffuser,IP 65 including fixing arrangement with proper connection complete all as specified and directed .
34Attending the complaints of unserviceable LED street lights/high mast light fittings comprising of 30W/45W/ 60W/ 80W/160 Watt of any make & model, fitted on the pole at any height with any type of fixing arrangement by taking down and checking loose connection in FRP box/ ACSR conductor or street light and making it serviceable and refixing itto the proper height including removing hanging grasses etc and tightening of all nuts,bolts,clamps and fixing of the street light at proper direction all as directed complete all as specified and directed .
35M&L for rewinding of capacity high-powered electrically driven, internally mounted, 3 phase power motor of capacity 3 HP for raising and lowering of the lantern carriage of high mast light by using best quality super enamelled copper winding wire of existing gauge and existing nos of turns including varnishing for "F" class insulation and drying in heat chamber with replacement of bearing and refixing, testing, commissioning complete all as specified and directed.
36M&L in replacement of stainless steel wire rope suitable for high mast light, overall diameter of the rope shall not be less than 6 mm, the breaking load of each rope shall not be less than 2000 Kgcomplete all as specified and directed.
37M&L for servicing the raising and lowering mechanism of high mast light by opening the gear box and greasing of all movingparts for smooth functioning of raising and lowering of the lantern carriage for maintenance purposes complete all as specified and directed.
38Cutting/trimming of tree branches not exc 30cm girth,sapling,shrubs etctouching/ approaching the LT/HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the LT/HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed
39S&F in replacement multistranded copper conductor cable ,2.5 Sqmm, 5 core ,1100 volts grade including PVC conduit from high mast panel to high mast lights with suitable cable lugs, clamps, nut, bolts etc complete all as specified and directed.
40S&F in replcementmultistranded copper conductor cable, 1.5 Sqmm, 2 core, 1100 volts grade complete all as specified and directed.
41M&L for painting to steel tubular poles upto 9metre long including attachments (cross arms, clamps, GI pipes etc) complete with two coat of aluminium paint after scraching out old paint, cleaning the existing surface for rust free & preparing of the existing surface for paintingincluding marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ Stricker includingpainting strips in alternate from bottom to top with three strips of white synthetic enamel paint & two strips of Yellow/ black paint(as per existing pattern) through out the circumference of pole andapplying one coat of white washing on PCC copping of pole after preparing the existing surfaces complete all as specified and directed.
42M&L for painting with two coat ofaluminium paint to channels, cross arm, clamps and pipes fixed/ mounted on LT pole after scraching out old paint, cleaning and making existing surface rust free and applying two coat of cement base paint (white ) on LT PCC pole including painting strips in alternate from bottom to top with three strips of white synthetic enamel paint& two strips of Yellow/ black paint (as per existing pattern) throughout the circumference of pole including one coat of lime wash on PCC copping of pole complete all as specified and directed.
43S&F in replacement pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998, errecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and white colour upto 1.5 metre height from top of PCC pedestal/coping of poles and numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed
44M&L for plain cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling & mass concrete including necessary formwork (where required) complete all as specified and directed.
45M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as in coping of poles etcincluding weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed.
46Detection/finding out the exact LT fault location from both end terminations of underground cable by necessary excavation/earth work or by fault locator machine and making it serveceable including making good the surface as per existing at site complete all as specified and directed.
47M&L for heat srinkable type straight through joint, outdoor type for LT underground cable of size 10 to 16 sqmm, 4 coreincluding excavation and earth work in any type of soil/hard standingcomplete all as specified and directed.
48S&F in replacement LED post top lantern of 5 watt, IP 65,fitted on minimum 1 meter coloured metallic pipe including PCC work complete all as specified and directed.
49Disconnecting, dismantling and taking down carefully ACSR conductor ofany size from poles of LT/HTcomplete all as specified and directed.
50S&F Aluminium conductor steel reinforced (ACSR), stretched on HT/LT poles without any kink and bends of various sizes complete including fixing to insulator with aluminium binding wire and coloured sleeved jumper connection with PG clamps complete all as specified and directed . Note: The size of conductor shall be as directed by Engr-in- Charge.
51S&F in replacement Shackle type insulator, porcelain, vitreous ,white, brown or green insulator including galvanised mild steel straps,washers, insulator bolts,washers and nuts,working pressure 1100 Volts,height 75 mm ,maximum dia 90 mm including31x3 mm galvanised steel straps and 12 mm dia of bolts complete all as specified and directed.
52Dismantling existing high mast pole of 16 metre height with flood light & fittings etc and shifting from existing site to another site and installing at new site with 02 nos anchor plates having minimum thickness 10mm and of size as per existing,required numbers of bolts 760mm long and minimum dia 25mm with nuts and making cable connectionetc complete all as specified and directed . Note:- Excavation,earthwork,PCC work & steel for base shall be measured and paid separately.
53M&L for Mild steel TMT bars 10mm dia and over , cut to length, bent to shape as required, including cranking, bending and binding with& including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed .
54M&L for preparation of existing old painted surface of panels (inside & outside surfaces)of any size and at any height after scratching existing rusted surface and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
55Attending the complaints oftimer panelincluding timer and contactor of LED street light/ high mast light fitting, tightening the loose connection or wiring including setting the time of timer complete all as specified and directed . Note :- A Sum of Rs. 57,535.00 will be deducted on account of credit for dismantling/demolished/taking down material. Please refer detail on srl page No 24 (Schedule of credit) of Tender Documents.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy