Tender For Repair / Maintenance Of Water Supply Pipe Lines, Dg Sets, Fire Fighting Eqpt At Dlrl Kanchanbagh, Hyderabad, Hyderabad-Telangana

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Water Supply Pipe Lines, Dg Sets, Fire Fighting Eqpt At Dlrl Kanchanbagh, Hyderabad. Submission Date for this Tender is 27-05-2024. Diesel Generators Tenders in Hyderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

43320623
Tender For Repair / Maintenance Of Water Supply Pipe Lines, Dg Sets, Fire Fighting Eqpt At Dlrl Kanchanbagh, Hyderabad
Open Tender
Indian
Telangana
Hyderabad
27-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair / Maintenance Of Water Supply Pipe Lines, Dg Sets, Fire Fighting Eqpt At Dlrl Kanchanbagh, Hyderabad

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

Attachment

FileName File Description File Size
4344cdfc-4374-4ea3-ba10-5bba00c70e9e.html Tender Notice 0 KB
BOQ_730538.xls Tender Document 0 KB
Tenderdocument.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:REPAIR/MAINTENANCE OF WATER SUPPLY PIPE LINES,DG SETS,FIRE FIGHTING EQPT AT DLRL KANCHANBAGH,HYDERABAD.
Sl. No. Item Description
1Taking down old existing unservicable Silver Ion Electrode,carefullyfrom the Silver Inozation plantand Supply, fixing and testing, commissioning new complete set of Silver Ion Electrodesuitable for disinfects the water 50,000 LPH (Litre Per Hour) water of plant model BW/ECO50complete of make-BHARATI WATERS all as directed by Engr-in-charge.
2M&L for CI spigot and socket pipes such as bends, tapers ( any type, radius and angle ) Tee, collars caps and plugs for CI pipes upto 200mm bore complete all as directed by Engr-in-Charge. Make- ELECTRO STEEL CASTING LTD/TISCO/KARTAR/KESORAMNote :-(a)Run lead joints will be measured and paid separately under relevant items of this schedule. (b)Earth work shall be measured and paid separately.
3M&L for repairing, Jointing, Arresting the leakages of existing GI Pipe line upto 25mm dia. Note :- This job inclues excacation/ refilling and bends, Tee, Reducer, sockets etc for restricting the leakage.
4All as per items No 3 but for pipe 40 mm to 80 mm dia.
5Supply and fix GI pipe of HeavyClass of 80 mm size of 3.5 mtr long of both end threaded complete including taking out taking out old unserviceable suction pipe from the sumps complete all as directed by Engineer-in-Charge. Make :- BST/ JINDAL/ Oswal / TATA
6Taking out old unserviceable15 mm GI pipe line and supply and fixing/ laying GI tubing medium grade of following dia, laid in trenches/ floors or fixed to walls including necessary GI fittingssuch as bends, elbows, nipple, sockets, unions, reducers, tees etc and making good the surface to match with existing surface complete all as directed . Note : - Necessary excavation and earth work shall be measured and paid separately under relavent items.
7All as per srl item No 6 but of 20 mm dia GI pipe complete all as directed.
8All as per srl item No 6 but of 25 mm dia GI pipe complete all as directed.
9All as per srl item No 6 but of 40 mm dia GI pipe complete all as directed.
10All as per srl item No 6 but of 50 mm dia GI pipe complete all as directed.
11All as per srl item No 6 but of 80 mm dia GI pipe complete all as directed.
12S&F gun metal gate valves 15 mm dia ISI marked with iron wheel head and both ends screwed including removing of unserviceable gun metal gate valve from the existing position of the following size gun metal valves complete all as directed.
13All as per item No 11 but for 20 mm dia size complete all as directed.
14All as per item No 11 but for 25 mm dia size complete all as directed.
15All as per item No 11 but for 40 mm dia size complete all as directed.
16All as per item No 11 but for 50 mm dia size complete all as directed. Make for item No. 11 to 15 :- Zoloto/ Leader/ Sant / Gem
17Repairs to CI sluice valve of size 80mm dia, removing from the sluice valve and providing the new gland packing of same size including taking down and fixing of bolts and nuts complete all as directed by Engineer-in-Charge.
18All as per item No 16 but for 100 mm dia size
19All as per item No 16 but for 150 mm dia size
20Repairs to existing leaking lead joints, with jointing materials such as lead wool forupto 80 mm dia size of CI pipe line including necessary excavation work complete all as directed by Engineer-in-Charge.
21All as per item No 17 but for 100 to 150 mm dia size
22S&F Cost Iron sluice valve of 80 mm dia size confirming to IS 780 complete with all connected accessories including taking down the unserviceble sluice valve complete all as directed. Make:- KARTAR / KIRLOSKAR / Leader / L&T
23All as per item No 19 but for 100 mm dia size CI sluice valve complete all as directed
24All as per item No 19but for150 mm dia size CI sluice valve complete all as directed
25Taking out/ lowering down the submersible pumps set of any capacity/ HP/ make from any depth including disconnecting the water, power supply mains and connecting the same after repair complete all as directed by Engineer-in-Charge. Note:- Equipment like tripod and chain pulling block etc are required to this Jobincluded in quoted rates shall be deemed to be included in unit rate.
26Repairs to submersible pump set of the capacity5 HP to 7.5 HP capacity upto 10 Stage, replacing with worn out spare parts and overhauling the same including testing complete all as directed by Engineer-in-Charge.
27All as per item No 21 but for 12 HP capacity upto 15 stage
28Repairs to submersible motor of electric driven of thecapacity 5 HP to 7.5 HP upto 10 Stage, of any make and any type including rewinding the motor with same gauge of copper wire and other required insulating materials reassembling complete including transporting, testing commissioning complete all as directed by Engineer-in-Charge.
29All as per item No 22but for 12.5 HP capacity upto 15 stage. Note for item Nos. 22to 23 :- Taking down & lowering shall be measured & paid under item No.22
30Bailing out water and scraping, cleaning, the inside surface of under ground sump/ over head reservoirs with bleaching powder and remove all type of impurities from water tank after cleaning 01 coat of disinfactant shall be apply on inner surface of tankand make smooth with surface at any type of staging and at any height/ depth complete for the UG Sump 40,000 Glncapacity all as directed by Engineer-in-Charge. Note :- Pump for Bailing out water with all provision shall be provided by the contactor and Disinfactant shall be approved by the Engr-in-Charge, without any extra cost.
31All as per item No.24 but for UG Sump 20,000 gln capacity
32All as per item No.24but for UG Sump 15,000 gln capacity
33All as per item No.24 but for OH reservoir 25,000 gln capacity
34Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for cable protection trench and getting out in hard/ dense soil complete all as directed by Engineer-in-Charge.
35Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25cms of excavated hard/dense soil complete all as directed by Engineer-in-Charge.
36Removal of surplus soil to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed by Engineer-in-Charge.
37Replacement of unserviceable column pipe 50 mm dia size with new GI heavy grade pipe of 3.5 mtr long both end long threaded complete all as directed by Engineer-in-Charge.
38All as per item No 28 above but for 80 mm dia size Make for item No 28 & 29 :- TATA/ BST/ JINDAL
39Taking out userviceable PVC water proof cable of 4 sqmm 3 core copper conductor and replacement with new cable of same size suitable for submersible pumpset complete all as directed by Engr-in-Charge.
40Taking out unserviceable DOL starter of 3 phase, 415 V and replace with new DOL starter suitable for 5 to 7.5 HP capacity submersible pumps including all internal connections with copper wire testing and commissioning complete all as directed by Engineer-in-Charge. Make: L&T/CROMPTON GREAVES/ABB/HAVELLS
41Taking out unserviceablestar delta starter of 3 phase, 440 V and replace with new starter suitable for 10 to 15 HP capcity submersible pumps including all internal connections with copper wire testing and commissioning complete all as directed by Engineer-in-Charge. Make: L&T/CROMPTON GREAVES/ ABB /HAVELLS
42S&F of Symetfloat valve of the 25mm dia, high pressure, with float & fly nut, ISI marked incl taking down existing UNSV complete all as directed by Engr-in-Charge. Make- Prayag or Equivalent / Leader / Zoloto
43Removing the old unserviceable spindle and nut of CI sluice valve and S&F new brass spindleof 80mm dia size and nut including other required materials, viz rubber gasket, bolts and nut for CI sluice valve complete all as directed by Engineer-in-Charge.
44Description all as per item No 34 but for 100 mm dia size
45Description all as per item No 34 but for150 mm dia size
46Taking out water sample in containers and getting the water tested from the department of water waste examination with Indian Institute ofpreventive medicine(IIPM) at Narayanaguda or NRDC Ltd at Himayatnagar for chemical test complete all as directed by Engineer-in-Charge
47Description all as per item No -37 above but for bacteriological test complete all as directed by Engineer-in-Charge
48M&L in repairsfor valve pit chamber of 1200 x 1200 x 900mm bybricks work and foundation concrete and M&L for 230 mm thick brick walls, complte with mild steel sheet cover of 1.8 MM thick and angle iron of size 40x40x6MM duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and including locking arrangement and lifting handle and plastering in cement mortar 1:4 and 10 mm thick plaster to all internal and external exposed surfaces including two coats of white wash on wall complete all as directed by Engineer-in-Charge.
49All as per item No 39 abovebut for Valve pit size 900x900x900 mm
50Taking out 7.5 HP to 10 HP capacity mono block pump set from installed position overhauling the pump and replacement of gland bush, nuts, bolts gland packing including replacement of bearings water seal, gland packing, Tee bolt, nut including one coat of painting and refixing at site testing and commissioning complete all as directed by Engineer-in-Charge.
51Taking out 7.5 HP to 10 HPcapacity motor from installed position removing the burnt out winding and rewinding the same gauge of super enameled copper wire varnishingtesting and commissioning at site complete all as directed by Engineer-in-Charge.
52M&L forflushing out the existing 150mm dia bore wellfor flushing out sand, mud with drilling machine till clean water is obtained complete all as directed by Engineer-in-Charge. Note:- Taking out and lowering down of submersible pumpset,pipe and electrical connection shall be measured and paid seperately.
53S & F cast iron non return valve of size 80mm dia including rubber gasket, bolts and nuts including removing of unserviceable Non return valve complete all as directed
54All as per srl item No.44 but for non-return valve of 50 mm dia complete all as directed. Make for item No. 44 & 45 :- Kartar/ Leader / Sant / Kirloskar
55S & F Foot valve of size 80mm dia , heavy duty including all necessary accessories required like rubber gasket, nuts, bolts etc completeincluding taking out the old rusted foot valve from the sump complete all as directed. Make:- Leader / Sant / Kirloskar
56All as per srl item No.46but of 150mm dia foot valve.
57Supplying of Puri Chlor brand Calcium Hypochlorite 65%-70% Chlorine content in Granular form to mix with drinking water received at Pump house for maintaining water purity and PPM,complete all as specified and directed by Engr-in-charge. MAKE: Declibac Technologies or Equivalent approved by GE
58Maintenance of DG set and carrying out ‘B’ check and replacement of ‘B’ check kit filters such as Oil filter, by pass filter, fuel filter,CR element and CR plates complete with ‘O’ rings and draining of Engine oil and topping up with the new engine oil complete testing all as specified and directed by the Engr-in-Charge for the following capacity DG sets:- Note :- 1. Engine oil shall be measured and paid separately. 2. B Cheak to be carried out every after 250 hrs run or 6 months whichever is earlier. Make: KIRLOSKER/ CUMINS /GREAVES
5963 KVA DG Set
60125 KVA DG Set
61160 KVA DG Set
62200 KVA DG Set
63250 KVA DG Set
64Renewal of unserviceable batteries with maintenance free batteries of 180 AH, 12V including connecting to DG set complete all as directed. Make:-EXIDE/ AMARON
65Attending thebreakdown of any capacity/make DG Sets, AMF Panels, by Technician & helper for checking all components and identifying and rectifying the faults and give report to concerned JE complete all as directed. Note :- Spare Parts for rectifying the fault shall be measured and paid seperately.
66S&F in repairsautomatic voltage regulator (AVR) upto 250 KVA DG set and testing complete all as directed. Make:- As per OEM make.
67Dismantling of exhaust pipe of the DG set by unscrewing nuts and bolts and taking down the pipe with muffler, removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as directedfor the following capacity DG Sets.
68110KV to 250 KVA DG set.
69Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 12 and 24 volts, 180 /200 AH and taking down the self starter and transporting to civil workshop for carrying out repairs including rewinding to armature coil and field coil with same guage and same turns as per existing, complete overhauling the system including replacing the unserviceable parts such as bearing, carbon brushes, clutch plates etc refixing the self starter in its original position, testing and commissioning complete all as directed. .
70Disconnecting the oil cooler of 110 KVA to 250 KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed.
71S&F in repairs air cleaning element inner and outer with necessary ‘O’ rings for the DG sets of following capacities as that of existing make and model complete all as directed.
72Upto 110 KVA DG Set
73125 KVA to 160 KVA DG Set
74200 KVA to 250 KVADG Set
75Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and of various capacities of DG sets and taking down the radiator assembly by unscrewing all mechanical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers ofradiator assembly cleaning thoroughly the chocked pipe of the radiator by using detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers etc., complete all as directed for the following DG sets:-
76Upto 110 KVA DG Set
77125 KVA to 160 KVA DG Set
78200 KVA to 250 KVADG Set
79Renewal of battery cable leads of copper conductorwith brass lugs terminal, for the 12V 180 /200 AHbatteries for self stater as that of existing size and length complete all as directed.
80S&F in repairsautomatic cut off Battery Charger suitable for 12 V,up to 10 Amp Battery complete all as directed . Make SMPS/ Phonix
81S&Fin repairs automatic cut off Battery Charger suitable for 24 V, up to 10 Amp Battery complete all as directed. Make SMPS/ Phonix
82Renewal of "V" belts for the following capacity DG sets as perexisting size and model complete all as directed. Make:- FENNER/ DUNLOP
83Upto 110 KVA DG Set
84125 KVA to 160 KVA DG Set
85200 KVA to 250 KVADG Set
86Renewal of existing unserviceable water temperature gaugefor the DG set of any description complete all as directed.
87Renewal of existing unserviceable oil pressure gaugefor the DG SET of any capacity complete all as directed .
88Renewal of unserviceable Solenoid switchfor DG set of any make and any capacity complete all as directed. Make :- RUSTON/ GREAVES COTTON/Kirloskar/CUMMINS.
89Supply and filling the new engine oil 15W/40 for toping up, upto the required level complete all as directed. Make :- CASTROL/ INDIAN OIL/ SERVO
90Drain out the fuel from the fuel tank of DG set of capacity 600 Ltrs and above and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat ofsynthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed.
91Removing of defective engine oil control pressure switch and supply & fix new engine oil control pressure switch suitable for up to 250 KVA setcomplete all as directed. Make Kirloskar- Cummins
92Renewal of defective wiring with copper wire of existing size including replacement of electrical/ electronic parts of AMF panel & DG Set, complete all as directed. Note: - Supply only Electrical/ Electronic spare parts shall be measured and paid separately. Supply only of following spare parts:
93Auxiliary contactor 240 Volts,(2NO.+2NC).
94ON and OFF delay timer 240 V AC and 24 V DC.
95Over load relay.
96ML - 4 contactor.
97Earth Fault Relay IRII-31-E1-WD Suitable for 250 V, AC. Make: C&S
98Single phase preventer
99Auxiliary Relays 24Volts / 6A
100PLC based AMF relay unit
101Low lube oil safety switch
102Booster Relay 24Volts / 10A
103Battery charger 24 V /10A panel mounting type
104Coolant temparature sensor
105LED indicating Lamp
106Push buttons
107Selector switches
108Removing the defective charging dynamo of capacity 24 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the same replacing of armature, field coils reconnecting the same, refixing back, in original position testing and commissioning complete all as directed.
109Supply & topping up ofInhibitor corrosion (coolant additive concentrate) as required(TVS Make) complete all as directed.
110Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as directed.
111Dismantling/taking out old unserviceable alternator (charging of battery) and taking out worn out spares such as ammeter, brush and field winding and repair the same by replacing ammeter, brush and rewinding of field coil with same guage of copper wire and testing complete all as directed .
112Calibration of PT pump and replacement of PT Pump kit, gear gasket, etc whichever is required for smooth functioning of DG Set complete all as directed.
113Calibration of injectors by replacing injector cup, barrel plunger for smooth functioning of engine, testing completeall asdirected .
114S&F PVC insulated, heavy duty, unshealted ,multi Stranded Copper Cable of35 Sqmm single corewith suitable size lugs crimpedon both side complete all as directed.
115S&F Flexible Bellow suitableup to 125 KVA Gen Set. Make as per OEM
116Disconnecting of alternator from 63 KVA to 250 KVA capacity DG set, after Disconnecting from Generaror shifting to civil workshop, taking out burnt out winding from Stator & Rotator, Cleaning thoroughly and rewinding the stator,rotor with suitable guage of super enameled copper conductor similar to that of existing size including necessary insulating material varnishing, heating,replacingbearings in rotor and stator side, reassembling of alternator, bringing back to the site refixing and installation over foundation with proper alignment, testing and commissiong complete all as directed. Note :- cost oftaking up and down from the site to workshop vice versa with vehicle and necessarylabour shall bedeemed to be included in quoted rates.
117S&F in repairs MCCB 250 Amps capacity 4 pole 38 KA breaking capacity complete all as directed. Make: Schnider/Havells/C&S
118Supply, fixing inand test run theFly-wheel Ringof existing model,size suitable for DG set of capacity 63 to 250 KVA including taking down old unserviceble fly wheel ring complete all as directed.
119Supply and fixin repairs Stanguard AutoTransfer switch (ATS) with enclouser of capacity 200 Amp 4 pole with automatic/manual with complete protectionall accessorices complete all as directed.
120Supply, fixing,testing and commissioning Generator set control panel with Engine electron fuel controller for 125 KVA DG Set of alongwith connected items i.e Fuel control governor, ausillary relays, engine harness wiring and alternator harness wiring, CTs, lube oil safety, oil pressure transducer, coolant temp sensor complete including taking down unserviceble generator set panel all as directed. Make : Kirloskar/Cummins (Existing)
121Supply, Fix & test run the DG set after replacing Diesel feeder Pumpof existing model,sizesuitable to DG Set of capacity 125 to 500 KVA including taking down old unserviceable disel feeder pump complete all asdirected.
122M&L for removing old rusted painted from complete DG Set surfaces ofthe DG Set of capacity upto250 KVA complete with one coat of Primer andtwo coats ofspray painting with existing colour paint synthetic enamel type including writing Ser No of DG set complete all as specified and directed.
123Renewal of 3 pole 415 volts 50Hz Power Contractors of the following capacity including Connecting & testing complete all as directed by Engineer-in Charge. MNX 25 Contractor or its Equivalent
124MNX 40Contractor or its Equivalent
125S&F Repair/ replacement of timer 0 to 60 mincomplete all as directed.
126S& F 6 core 6 sqmm copper wire for connection to control panel to motor all as directed
127Comprehensive Annual Maintenance including rectification of any faults of various Fire Alarm Systems installed at DLRL &MLCP atDLRL,area including checking, testing, cleaning of Smoke Detectors, Heat Detectors, Beam Masters, Hooters, Manual Call Points, spirit bulbs etc. by carrying out preventive Maintenance and Corrective Maintenance rectifying defects in existing system and making the entire system trouble free and efficient functioning with all accessories connected to the Fire Alarm systems complete all as directed.
128Note: (i)Spares if any required shall be measured and paid under the relevant items of schedule and cost of labour/Fire fighting Technician/ Engineer, element like Tools/Eqpt, cleaning agents etc are deemed to be included in the quoted rate. (ii)The preventive maintenance schedule shall be as follows:- (a) MONTHLY - Checking of all cards (control card, zone card, fail card, charger card etc) in control panel for their healthly working condition. Testing of all zones by checking smoke detectors at random with smoke testing of Hooters and MCPs. (b) QUARTERLY - cleaning of all smoke detectors, heat detectors, response indicators, hooters, MCPs and Beam mastars and testing of all smoke detectors with smoke and heat detectors with heat. (iii)Service report is to be generated for the above monthly and quarterly maintenance for all the systems andsubmitting to Engr-in- Charge. (iv) Brakedown should be rectified as and when the system brakes down.
129Supply and Installation of the followingconventional type Zone microprocessor based fire alarm control panel suitable to the existing system including dismantling of old un serviceable control panel and rewiring the connections as required complete all as directed.
1302 Zone control panel Adressable Make: Minimax/agni/securits
1314 Zone control panel conventional type Make : Dekars /Agni/Servico
1328 Zone control panel conventional type Make : Dekars /Agni/Servico
133Supply of the following spares required for the efficient functioning of the Conventional Fire Alarm Systems for item Nos.01 & 02 here-in-before.
134Ionisation / Photo Electric (Optical) Smoke Detector Make: Apollo / System Sensor
135Heat Detector. Make: Apollo / System Sensor
136Electronic Hooter. Make : Dekars / Servico/Agni
137Manual call point. Make : Appolo/Servico/Murley
138Response Indicator. Make : Dekars / Servico/Agni
139Transformer 5 Amp, 24 – 0 – 24 Volt.
140Maintenance Free Battery 12 V, 7 AH. Make: EXIDE / AMCO
141Maintenance Free Battery 12 V, 12/18 AH. Make: EXIDE / AMRON
142Supply of the following spares required for the efficient functioning of the Addressable Fire Alarm Systems complete all as directed .
143Addressable Ionisation / Photo Electric (Optical) Smoke Detector Make: Apollo / Cooper /morley-IAS/Honeywell
144Addressable Heat Detector. Make: Apollo / Cooper /morley-IAS/Honeywell
145Addressable dual tone Electronic Hooter. Make: Apollo / Cooper /morley-IAS/Honeywell
146Addressable loop Card. Make: Apollo / Cooper /morley-IAS/Honeywell
147Addressable Mannual pull station. Make: Apollo / Cooper /morley-IAS/Honeywell
148Programming of Loop card any zone (Addressable/conventional).
149Testing and Refilling of Foam type Fire Extinguisher 9 Ltrs. Capacity complete fully charged gunmetal cap heavy inner container with wall mounting brackets etc. confirming to IS: 933.
150Testing and Refilling of Dry Chemical Powder type Fire Extinguisher 5 Kg. Capacity powder and CO2 gas catridge of 120 gms. Capacity confirming to IS: 2171.
151Testing and Refilling of Dry Chemical Powder type Fire Extinguisher 9 Kg. Capacity powder and CO2 gas catridge of 180 gms. Capacity confirming to IS: 2171.
152Testing and Refilling of Carbon – Di – Oxide type Fire Extinguisher 4. 5 Kg. Capacity CO2 gas confirming to IS: 2878
153Taking down old unserviceable hydrant valve and Supply, Installation, Testing and Commissioning of Single Headed Hydrant valve confirming to IS 5290 with ISI mark of size 63 mm dia oblique type with instantaneous hose coupling adaptor etc. with all neceesary fittng materials complete required.
154Taking down old unserviceable hydrant hose pipe and Supply, Installation, Testing and Commissioningof Hydrant hose pipe, 63 mm dia and 2x15 mtrs long RRL type with Gunmetal 63 mm size male coupling at one end andfemale coupling at the other end.It should with stand a burtsting pressure of 450 psi, rot proofed, with ISI mark. Hose shall comply to IS 636
155Taking down old unserviceable branch pipe and Supply, Installation, Testing and Commissioningof short Branch pipe with 63 mm female instanteneous inlet made of gun metal, male threaded outlet, complete with hexagonal basednozzle heavy quality confirming to IS 903 etc. as approved and as directed.
156Taking down old unserviceable hose reel pipe and Supply, Installation, Testing and Commissioning of Fire Hose Reel pipe 20 mm dia. X 30 mtr. Long, high pressure with 5 mm out let GM nozzle with shut off valve(IS: 884 - 1969) includes stop cock and chromium plated nozzle with all neceesary fixing materials complete all as directed.
157S&F in repairs sprinkler bulb Spirit type 60 to 70 degree temperature fusible range suitablefor fire fighting sprinkler system complete all as directed.
158M&L for Scrapping of old existing paint of pipe lines for Fire fighting system of any sizes and applying two coats of enemel paint to match with the existing shade complete all as directed. Note - Rate quoted shall be deemed to include cost of Paint & tools.
159Scrapping of old existing paint of Fire cabinet (inside & outside) for Fire fighting system of any sizes and applying two coats of Red postal colour enemel paint. Note -Rate quoted shall be deemed to be include rates of Paint & tools.
160Repair and servicing of 60 to 100 HP Fire Fighting Pump and motor including all connecting parts by replacing gland, greasing & oiling and rectification of alignment of pump and motor, cleaning the carbon from the electrical connections and commissioning complete all as directed.
161Repair and servicing of 7.5 to 12.5 HP Fire Fighting Pump and motor including all connecting partsby replacing gland, greasing & oiling and rectification of alignment of pump and motor, cleaning the carbon from the electrical connections and commissioning complete all as directed.
162S&F of following parts of Fire fighting system with all necessary electrical connection with lugs of any size and testing commissioing including taking down the same complete all as directed.
163Contactor for fire Panel MNX 70 3Pole Make : L&T/C&S
164Electronic Timers Type ET 100 ML-6, 9-30 Sec, 415V, 50 Hz Make : L&T/C&S
165High Pressure control guage 02-14 Bar, 0-55 PSI , KP-36 Make : Denfoss